Documentation record
Registered dimensions (L × B × D)60.6 ft × 22.1 ft × 7.2 ft
Registered tonnagegross 53 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderASHTABULA, OH, UNITED STATES · built 1946
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAULT SAINTE MARIE, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 April 2026 · expires 30 April 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
15 October 2025
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8241240
19 May 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8186489
12 November 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036600
31 October 2023
Administrative Inspection · Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7817892
27 October 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7584452
2 November 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341810
6 October 2020
Internal Structural Exam · Deficiency Check · COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7079726
30 January 2020
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899598
15 October 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6841961
13 February 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6625307
6 November 2018
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6591015
19 January 2018
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6340579
21 September 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6271719
6 September 2017
Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261247
3 August 2017
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6233466
7 March 2017
Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261549
4 October 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6017478
12 September 2016
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000935
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 October 2022
Resolved
Found a small fuel leak on the genset. Determine the source and take corrective action to stop the leak to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 9 November 2022
Resolution: New gasket installed, ops check sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 October 2020
Resolved
Complete permanent repairs to wastage of main deck and associated structures and bulwarks as called out during October 2020 hull exam/internal structural exam.
Particular attention and repairs to the effected areas including: main deck hull plating in way of false transverse wall, accommodation space main deck plating along both bulwarks and bulwarks wastage, steering compartment access hull plating wastage, steering quadrant, steering compartment wasted structures, forward section of fantail (both port & stbd sides) hull plating and bulwarks wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2021
Resolved 16 March 2021
Resolution: All repairs completed, NDT witnessed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2018
Resolved
Install masthead light and stern light in compliance with Navigation Rules 21 and 23, to be completed to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 13 February 2019
Resolution: witnessed masthead & stern lights properly installed and operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 September 2017
Resolved
Properly mount E/R portable fire ext.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 21 September 2017
Resolution: Mounted.
Engineering › Bilge Water Management System › Strainer
Issued 6 September 2017
Resolved
Install bilge suction strainer on forward E/R bilge suction line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: installed
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 September 2017
Resolved
Replace outdated Nav Rules
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 September 2017
Resolved
Replace nonreflective (deteriorated) retro reflective tape on PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 September 2016
Resolved
2 child size PFDs not properly marked with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 September 2016
Resolution: corrected on the spot.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 September 2016
Resolved
Demonstrate low lube oil pressure and overspeed shutdowns on generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 October 2016
Resolution: Witnessed proper operation of LLO shutdowns. Neither generator is equipped with overspeed shutdowns per owners/operators manuals.