MAURY USCG vessel records
← All vessels

OJIBWAY

OJIBWAY is a 1946 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in October 2025, along with 9 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 15 October 2025.

Built
1946
Last inspected
15 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD8797
Flag
UNITED STATES
Maury page id
psix-42279

Documentation record

Registered dimensions (L × B × D)60.6 ft × 22.1 ft × 7.2 ft
Registered tonnagegross 53 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderASHTABULA, OH, UNITED STATES · built 1946
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAULT SAINTE MARIE, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 April 2026 · expires 30 April 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

15 October 2025 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8241240
19 May 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8186489
12 November 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036600
31 October 2023 Administrative Inspection · Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7817892
27 October 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7584452
2 November 2021 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341810
6 October 2020 Internal Structural Exam · Deficiency Check · COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7079726
30 January 2020 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899598
15 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6841961
13 February 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6625307
6 November 2018 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6591015
19 January 2018 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6340579
21 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6271719
6 September 2017 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261247
3 August 2017 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6233466
7 March 2017 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261549
4 October 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6017478
12 September 2016 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000935

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 October 2022 Resolved
Found a small fuel leak on the genset. Determine the source and take corrective action to stop the leak to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 9 November 2022
Resolution: New gasket installed, ops check sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 October 2020 Resolved
Complete permanent repairs to wastage of main deck and associated structures and bulwarks as called out during October 2020 hull exam/internal structural exam. Particular attention and repairs to the effected areas including: main deck hull plating in way of false transverse wall, accommodation space main deck plating along both bulwarks and bulwarks wastage, steering compartment access hull plating wastage, steering quadrant, steering compartment wasted structures, forward section of fantail (both port & stbd sides) hull plating and bulwarks wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2021
Resolved 16 March 2021
Resolution: All repairs completed, NDT witnessed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2018 Resolved
Install masthead light and stern light in compliance with Navigation Rules 21 and 23, to be completed to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 13 February 2019
Resolution: witnessed masthead & stern lights properly installed and operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 September 2017 Resolved
Properly mount E/R portable fire ext.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 21 September 2017
Resolution: Mounted.
Engineering › Bilge Water Management System › Strainer
Issued 6 September 2017 Resolved
Install bilge suction strainer on forward E/R bilge suction line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: installed
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 September 2017 Resolved
Replace outdated Nav Rules
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 September 2017 Resolved
Replace nonreflective (deteriorated) retro reflective tape on PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 September 2016 Resolved
2 child size PFDs not properly marked with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 September 2016
Resolution: corrected on the spot.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 September 2016 Resolved
Demonstrate low lube oil pressure and overspeed shutdowns on generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 October 2016
Resolution: Witnessed proper operation of LLO shutdowns. Neither generator is equipped with overspeed shutdowns per owners/operators manuals.

Ownership record