OJIBWAY is a 1946 freight ship. The Coast Guard has recorded 57 inspections since 1985, most recently in October 2025, along with 55 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 15 October 2025.

Built
1946
Last inspected
15 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8797
Flag
UNITED STATES
367302870
Maury page id
psix-42279

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1985–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)60.6 ft × 22.1 ft × 7.2 ft
Registered tonnagegross 53 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ASHTABULA, OH, UNITED STATES · built 1946
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAULT SAINTE MARIE, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 April 2026 · expires 30 April 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD8797MMSI 367302870 · active · compulsorily equipped · granted 26 April 2017, expires 14 July 2027
WTQ3260MMSI not assigned · expired · voluntarily equipped · granted 31 January 1997, cancelled 16 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 57

15 October 2025 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8241240
19 May 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8186489
12 November 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036600
31 October 2023 Administrative Inspection · Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7817892
27 October 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7584452
2 November 2021 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341810
6 October 2020 Internal Structural Exam · Deficiency Check · COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7079726
30 January 2020 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899598
15 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6841961
13 February 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6625307
6 November 2018 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6591015
19 January 2018 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6340579
21 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6271719
6 September 2017 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261247
3 August 2017 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6233466
7 March 2017 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261549
4 October 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6017478
12 September 2016 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000935
4 November 2015 COI Inspection · Drydock Exam · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5759213
26 July 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4391314
10 May 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4317315
15 January 2010 Internal Structural Exam · Administrative Inspection · Hull Examination · Drydock Extension
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3671415
18 June 2008 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3340256
2 July 2007 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2989724
1 July 2006 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2715564
4 April 2006 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2616450
18 November 2004 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2243765
4 November 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2234774
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978071
15 April 2003 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1774127
29 May 2002 Annual Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1622538
5 April 2001 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1466767
9 May 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1393428
5 October 1999 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1430762
9 April 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1441483
14 April 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1122750
11 July 1997 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1114892
30 April 1997 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1101505
10 April 1997 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1100001
9 April 1996 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1079115
16 May 1995 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 924157
14 April 1995 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 840151
22 November 1994 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1171506
14 October 1994 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1183632
5 April 1994 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 855850
22 March 1994 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 855995
19 March 1993 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 840033
15 April 1992 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 958150
19 March 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 904387
24 March 1990 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1222315
20 March 1990 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 902485
5 October 1989 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1021469
16 March 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 895517
23 March 1988 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 991084
27 March 1987 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1023071
26 March 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1303449
21 May 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 986005

Deficiency record · 55

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 October 2022 Resolved
Found a small fuel leak on the genset. Determine the source and take corrective action to stop the leak to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 9 November 2022
Resolution: New gasket installed, ops check sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 October 2020 Resolved
Complete permanent repairs to wastage of main deck and associated structures and bulwarks as called out during October 2020 hull exam/internal structural exam. Particular attention and repairs to the effected areas including: main deck hull plating in way of false transverse wall, accommodation space main deck plating along both bulwarks and bulwarks wastage, steering compartment access hull plating wastage, steering quadrant, steering compartment wasted structures, forward section of fantail (both port & stbd sides) hull plating and bulwarks wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2021
Resolved 16 March 2021
Resolution: All repairs completed, NDT witnessed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2018 Resolved
Install masthead light and stern light in compliance with Navigation Rules 21 and 23, to be completed to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 13 February 2019
Resolution: witnessed masthead & stern lights properly installed and operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 September 2017 Resolved
Properly mount E/R portable fire ext.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 21 September 2017
Resolution: Mounted.
Engineering › Bilge Water Management System › Strainer
Issued 6 September 2017 Resolved
Install bilge suction strainer on forward E/R bilge suction line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: installed
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 September 2017 Resolved
Replace outdated Nav Rules
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 September 2017 Resolved
Replace nonreflective (deteriorated) retro reflective tape on PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 21 September 2017
Resolution: replaced
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 September 2016 Resolved
2 child size PFDs not properly marked with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 September 2016
Resolution: corrected on the spot.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 September 2016 Resolved
Demonstrate low lube oil pressure and overspeed shutdowns on generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 October 2016
Resolution: Witnessed proper operation of LLO shutdowns. Neither generator is equipped with overspeed shutdowns per owners/operators manuals.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 November 2015 Resolved
Replace wingnut connections on all battery terminals with standard nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 12 November 2015
Resolution: Witnessed satisfactory installation.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 10 November 2015 Resolved
Paint bottom of exposed fire extinguisher on main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 12 November 2015
Resolution: Witnessed satisfactory maintenance.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 10 November 2015 Resolved
Demonstrate low lube oil pressure and overspeed shutdowns on generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 4 October 2016
Resolution: Witnessed proper operation of LLO shutdowns. Neither generator is equipped with overspeed shutdowns per owners/operators manuals.
Electrical › Electric Supply System (service) › Cable
Issued 4 November 2015 Resolved
Make connections on sender wires to gages in pilot house of premanent crimp type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 12 November 2015
Resolution: Witnessed satisfactory installation.
Construction/Loadline › Hull › Side Shell
Issued 10 March 2010 Resolved
inset found in port side shell of forepeak, 4th frame bay from stem, approx. 2 feet from deck. to be cropped and renewed at DDX
Action required: 705 - Other - as specified
Resolved 12 March 2010
Resolution: will address at DDX
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 10 March 2010 Resolved
Iron used as ballast in port ballast tank has broken through containment basket and is resting on the interior bottom plate. Crew is to repair the ballast containment/secure ballast prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Corrected
Construction/Loadline › Hull › Bottom Plating
Issued 15 January 2010 Resolved
Vessel failed to have vessel inspected and examined in dry-dock according to COI on November 30, 2009. Vessel requested extension that was subsequently denied. Vessel appealing denial.
Action required: 705 - Other - as specified
Resolved 21 March 2010
Resolution: Completed credit DDX and ISE
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 July 2007 Resolved
junction box above mde needs cover.
Due 18 August 2007
Resolved 15 August 2007
Resolution: junction box cover needed
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 2 July 2007 Resolved
Renew FCC radio certificate
Due 18 August 2007
Resolved 15 August 2007
Resolution: FCC Certificate sighted.
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 July 2007 Resolved
Make collision bulkhead watertight by removing or capping off unused ballast piping.
Due 18 August 2007
Resolved 15 August 2007
Resolution: Ballast piping capped off.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 July 2006 Resolved
Correct hailing port on Certificate of Documentation upon next renewal.
Condition: Unknown
Due 31 May 2007
Resolved 31 May 2007
Electrical › Electric Generation Source (service) › Generator
Issued 4 April 2006 Resolved
REPAIR LEAKING INTERCOOLER PUMP ON THE #1 GENERATOR
Due 4 May 2006
Resolved 2 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 4 April 2006 Resolved
STARTER SOLENOID LOOSE FROM MOUNTING BRACKET
Due 4 May 2006
Resolved 4 April 2006
Resolution: REPLACED MOUNTING BOLT. SECURE
Engineering › Steering Gear System › Linkage
Issued 4 April 2006 Resolved
INSTALL RUDDER STOPS ON PORT SIDE OF QUADRANT.
Due 5 May 2006
Resolved 28 April 2006
Resolution: Installed rudder stops.
Operations/Management › Cargo Transfer/Lightering › Persons in Charge Conference
Issued 4 April 2006 Resolved
CURRENT ABS CERTIFICATION NEEDED FOR THE LOAD HANDLING EQUIPMENT (CRANE).
Due 5 May 2006
Resolved 4 April 2006
Resolution: Inspection no longer required by Coast Guard Regulation. Now mandated by OSHA.
Engineering › Diesel Engine (propulsion-reduction gear) › Crosshead Assembly
Issued 4 April 2006 Resolved
REMOVE LOOSE UNUSED WIRING FROM PORTSIDE OF MDE.
Due 4 May 2006
Resolved 4 April 2006
Resolution: REMOVED WIRING.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 4 April 2006 Resolved
INSTALL RUBBER MAT (ELECTRICAL SAFETY) IN FRONT OF SWITCHBOARD
Due 4 May 2006
Resolved 4 April 2006
Resolution: INSTALLED MAT
Fire Fighting › Fire Pumps › Gland Sealing
Issued 4 April 2006 Resolved
REPLACE OR REBUILD PUMP AND SEALS.
Due 4 May 2006
Resolved 4 April 2006
Resolution: Replaced firepump with operational pump, installed pressure gauge on pump.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 4 April 2006 Resolved
REPLACE OR REPAIR PFD THAT HAS RIPPED STRAP.
Due 4 May 2006
Resolved 4 April 2006
Resolution: REPLACED PFD
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 15 April 2003 Resolved
Replace batteries in the Lifejacket Lights.
Condition: Unknown
Due 15 May 2003
Resolved 15 April 2003
Resolution: Batteries replaced during inspection.
Lifesaving › Lifebuoys
Issued 29 May 2002 Resolved
REPAIR LIFERING LOCATED ON STBD SIDE PILOT HOUSE, MARK WITH VESSEL NAME
Condition: Unknown
Due 29 May 2002
Resolved 29 May 2002
Lifesaving › Lifebuoys
Issued 29 May 2002 Resolved
REPLACE LIFERING LINE FOR LIFERING LOCATED ON MAIN DECK FORWARD.
Condition: Unknown
Due 29 May 2002
Resolved 29 May 2002
Lifesaving
Issued 5 April 2001 Resolved
IMPROPER LANYARD, NO COR-RES CLIP, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Engineering
Issued 5 April 2001 Resolved
METALLIC FLEXIBLE PIPING FOR EXHAUST SYSTEMS ON BOTH S/S GENERATORS EXPOSED, PERSONNEL HAZARD, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Electrical
Issued 5 April 2001 Resolved
GROUND DETECTION LAMPS EXTINGUISHED IN MAIN SWITCHBOARD, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 5 April 2001 Resolved
ITEMS EXPIRED AND MISSING FROM FIRST AID KIT, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 9 May 2000 Resolved
EXTRA LIFE BUOY BADLY DETERIORATED, CONDEMNED & REMOVED FROM SERVICE.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 9 May 2000 Resolved
LIFERAFT INSTRUCTIONS MISSING, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 9 May 2000 Resolved
PFD DONNING INSTRUCTIONS MISSING, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Engineering
Issued 9 April 1999 Resolved
LABEL FUEL OIL SHUT OFF VALVES IN DIRECTION OF CLOSURE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 9 April 1999
Resolved 9 April 1999
Fire Fighting
Issued 9 April 1999 Resolved
ONE 15# CO2 CYLINDER OVERDUE FOR HYDROSTATIC TESTING, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 9 April 1999
Resolved 13 April 1999
Lifesaving
Issued 9 April 1999 Resolved
IMPROPERLY STOWED DECK GEAR AND POLLUTION RESPONSE MATERIALS OBSTRUCTING ACCESS OR VISIBILITY OF FIRE HOSE STATION AND FUEL OIL SHUT OFF VALVE, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Navigation
Issued 9 April 1999 Resolved
NAVIGATION RULES OUTDATED, CORRECTED ON SPOT.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Lifesaving
Issued 9 April 1999 Resolved
7 OF 24 PFD LIGHTS INOPRABLE, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Lifesaving
Issued 9 April 1999 Resolved
CHILD SIZE LIFE PRESERVERS INCORRECTLY STOWED; MIXED WITH ADULT SIZE AND STOWAGE BOX NOT LABELED PROPERLY. CORRECTED DURING INSPECTION.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Lifesaving
Issued 9 April 1999 Resolved
PERMANENTLY INSTALL MOUNTING BRACKET FOR FLOAT LIGHT ON LIFE BUOY BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 9 April 1999
Resolved 9 April 1999
Lifesaving
Issued 9 April 1999 Resolved
PROVIDE BUOYANT LINES ON LIFE FLOATS IN REPLACEMENT OF EXISTING NYLON, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 9 April 1999
Resolved 9 April 1999
Documentation
Issued 10 April 1997 Resolved
Permanently affix official number to integral part of the vessel.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Electrical
Issued 10 April 1997 Resolved
Repair corroded/holed battery box in engine room.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Lifesaving
Issued 10 April 1997 Resolved
Mark three(03) adult, three(03) child size PFDs and Fire ax with vessel name.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Lifesaving
Issued 14 April 1995 Resolved
Provide lifeline on 2nd bridge deck ring buoy.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Documentation
Issued 14 April 1995 Resolved
Post or stencil garbage placard as described in 33 CFR 151.59(e)(2).
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Electrical
Issued 14 April 1995 Resolved
Repair ammeter for #2 ship service generator.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Engineering
Issued 14 October 1994 Resolved
Install steel piping system between overboard discharge line and sea chestsin way of current flexible hose installation, or disconnect system.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 22 March 1994 Resolved
MISSING BILGE SUCTION STRAINERS IN ENGINE ROOM AND TWO COMPARTMENTS AFT OF ENGINE ROOM (3 TOTAL).
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Electrical
Issued 23 March 1988 Resolved
PROVIDE ADEQUATE GUARDS TO NEWLY INSTALLED PORT GENERATOR.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.