MAURY USCG vessel records
← All vessels

MANCHENIL BAY

Built
1969
Last inspected
19 June 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 19 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7943952
HO4392
422940
Flag
PANAMA
Maury page id
psix-422940

Documentation record

Tonnage as PSIX records it265 - Convention (Subpart B), Gross Ton
79 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 39 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SALISBURY Tank Barge · MISLE 43495 · 24 May 2000 · activity 47725

Inspection history · 39

19 June 2026 PSC B · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8408335
10 December 2025 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8279712
27 May 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8144740
27 May 2025 CCSSC Examination · PSC A · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8144754
25 September 2024 Deficiency Check · PSC B · CCSSC Examination · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8008939
16 April 2024 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7901607
21 March 2024 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7886482
7 March 2024 CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7873372
7 August 2023 CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7744501
23 February 2023 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7640918
20 January 2023 CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7624350
5 August 2022 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7525450
20 July 2022 PSC B · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7511149
20 January 2022 CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7382828
8 July 2021 CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7249176
7 January 2021 CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7120810
15 July 2020 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7006772
1 July 2020 CCSSC Examination · PSC A
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6984455
9 December 2019 CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6869766
10 August 2017 ISPS II Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6227537
30 July 2015 CCSSC Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5198578
4 June 2014 CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4876779
18 February 2014 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4801341
13 February 2014 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4799770
17 July 2013 PII Safety Exam · CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4651178
4 March 2013 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4542974
24 January 2013 CCSSC Examination · MTSA Verification · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4521493
3 October 2012 MTSA Verification · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4450435
4 April 2008 NPV Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3177855
17 November 2006 Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2823731
13 March 2006 PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2711656
28 June 2005 MTSA Verification · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2406706
29 June 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2115514
6 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060594
30 April 2004 Uninspected Other
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2056370
8 April 2003 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1811040
24 May 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 47725
25 April 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 647857
5 April 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 182821

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2025 Resolved
Adequate provisions should be made to facilitate cleaning, inspection and maintenance of machinery installations including boilers and other pressure vessels. PSCOs witnessed a 02 sec droplets of water from the port side generator water cooling pump due to a faulty cap. CCSSC 2.24.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Received via email images and video evidence replaced cap on the port side generator where no water can be seen coming from the replaced cap. See documents for supporting files.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 September 2024 Resolved
A main source of electrical power of sufficient capacity to supply all electrical services necessary for normal operation and under emergency conditions. The main service generator is incapable of providing enough power for the normal operation of the ship and the use of the emergency fire pump simultaneously. CITE: CCSSC 2.33.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the generator produce enough power for the required functions.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 September 2024 Resolved
A self-contained emergency source of electrical power should be provided. The vessel's secondary main generator is inoperable. CITE: CCSSC 2.34.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the generator start and maintain power.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 September 2024 Resolved
The main fire pump should be capable of delivering water for fire fighting purposes. PSCO was unable to verify if the main fire pump was operational due to the condition of the generators as listed above. CITE: CCSSC 3.3.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the main fire pump deliver water for fire fighting purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 September 2024 Resolved
Hydrostatic release units should be serviced at intervals not exceeding 12 months. The starboard liferaft's hydrostatic release expired in March of 2024. CITE: CCSSC 4.8
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Vessel was equipped with a new hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2024 Resolved
AIS must be maintained in effective operating condition, which includes the continual operation of AIS at all times while the vessel is underway. The vessel's AIS is currently inoperable and is incapable of operating continuously while underway.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: AIS antenna was replaced, restoring the continual operation of the AIS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2024 Resolved
A minimum of two inspections of the outside of the ship's bottom should be carried out during any five year period. Ship's last dry dock was in June of 2019. Ship was issued an extension to their dry dock date which expired on the 15th of August, 2024. CITE: CCSSC 1.10.1.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 November 2024
Resolved 27 May 2025
Resolution: Received dry dock completion report. Completed in Cartagena, Colombia.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 25 September 2024 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan is on the ship. The ship currently does not have a garbage management plan.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 October 2024
Resolved 4 October 2024
Resolution: Vessel was found to have a garbage management plan.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 25 September 2024 Resolved
When garbage us discharged to a reception facility, the record must contain the following information: the estimated amount of each category of garbage discharged, described by volume in cubic meters. The estimated amount of each category of garbage was not recorded.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 September 2024
Resolved 25 September 2024
Resolution: Vessel's master was informed that they will need to record the amount of each category of garbage and will do so moving forward.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 March 2024 Resolved
In every ship there should be provided a sufficient number of approved portable fire extinguishers to the satisfaction of the administration. One fire extinguisher was found to be inoperable. CCSSC 3/3.91.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 16 April 2024
Resolution: A 20 pound fire extinguisher, type ABC was installed onboard MANCHENIL BAY in comppliance with Class Rules and Fire Safety Control Plan.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 January 2023 Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location. The vessels fire detection alarm panel is not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2023
Resolved 23 February 2023
Resolution: Cleared by facetime call with [name withheld] alarms and newly installed panel.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 January 2023 Resolved
The capacity in which the holder of a certificate is authorized to serve shall be identified in the form of an endorsement. The vessel's master as well as the chief engineer do not have an administration endorsement.
Action required: 10 - Deficiency Rectified
Due 20 January 2023
Resolved 20 January 2023
Resolution: Flag State endorsements issued prior to PSCO departure.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2023 Resolved
Fire extinguishers shall be periodically examined and subjected to such tests as the administration may require. The vessel's CO2 fire extinguisher cylinders are past their annual test date.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2023
Resolved 23 February 2023
Resolution: Accepted Class document and photo evidence of inspected bottles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2022 Resolved
Arrangements for the storage distribution and utilization of the oil fuel should be such as to ensure the safety of the ship and persons on board. Oil tank for main engines in engine room leaking from inspection ports (2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2022
Resolved 3 August 2022
Resolution: Received photos from vessel representative, documenting the repairs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 July 2020 Resolved
The satellite EPIRB and VHF EPIRB shall be capable of floating free if the ship sinks and of being automatically activated when afloat. It was observed that the bracket housing the vessels EPIRB was broken and no longer held the EIPRB in place. The vessel was currently housing the EPIRB within the pilot house. Cite:CCSS Code CH. 5.3.3.3 Action:16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 15 July 2020
Resolution: Vessel received a new EPIRB bracket and hydrostatic release.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2020 Resolved
After any survey of the ship under 1.10 has been completed, no significant change shall be made in the structural arrangement, machinery, equipment and any other items covered by the survey, without permission of the Administration. The audible indicator for the vessels on board alarm system located on the bridge was inoperable. Cite:CCSS Code CH 1.11.2 Action:16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 15 July 2020
Resolution: Vessel repaired the alarm with a new part.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 10 August 2017 Resolved
0199- The Caribbean Cargo Safety Certificate shall be drawn up in the models given in the annexes. The certificate on board was missing endorsement pages. Specifically attesting to the endorsement for inspections of outside the ships bottom. CCSSC - Ch 1.14 50AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 9 December 2019
Resolution: Vessel was able to produce the full recently-issued CCSSC with all endorsement pages.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 17 July 2013 Resolved
0120-Load Lines-A periodical survey/inspection within 3 months of each annual anniversary date of the ILLC shall be conducted. Annual inspections are not documented on current/valid ILLC (6903711-2370962-001). Previous ILLC onboard documents annual inspections. Class to correct admin error. 66 ICLL Art. 14
Action required: 705 - Other - as specified
Due 19 January 2014
Resolved 18 February 2014
Resolution: Vessel received valid current International Loadline Certificate.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 January 2013 Resolved
0100 - Documentation - Fire control plans should be kept up to date. Plan indicates an emergency generator for its emergency source of power. Admin to verify and update as appropriate fire control plan and attest to a secondary (emergency) source of power onboard. CCSSC CH3 Part A 3.13
Action required: 705 - Other - as specified
Due 7 February 2013
Resolved 4 March 2013
Resolution: Received, reviewed and accepted Class report from Overseas Marine Certification Services.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 October 2012 Resolved
1581 - The position of rudder should be indicated on bridge. Vessel did not have rudder angle indicating on bridge. CCSSC 2.33.8. Action 50b.
Due 2 November 2012
Resolved 24 January 2013
Resolution: Reviewed and accepted class report from American Bureau Of Shipping that the rudder angle indicator was installed on bridge. CCSSC 2.33.8 and confirmed rudder angle indicator was operational.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 4 April 2008 Resolved
Found overspeeds to be set below manufacturers setting. Classification society ABS is to conduct satisfactory operational testing of the port/starboard main engines and provide the report to Coast Guard for approval prior to operating as a tug vessel in U.S. waters.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 6 April 2008
Resolution: ABS reexamined overspeed shutdown and operationally tested, deemed satisfactory.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 4 April 2008 Resolved
Provide CG 2692 within the required time limit, explaining the cause and corrective actions to ghost overspeed tripping of the main engines prior to operating as a tug vessel in U.S. waters.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 6 April 2008
Resolution: Received CG-2692

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.