Inspection history · 39
19 June 2026
PSC B · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8408335
10 December 2025
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8279712
27 May 2025
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8144740
27 May 2025
CCSSC Examination · PSC A · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8144754
25 September 2024
Deficiency Check · PSC B · CCSSC Examination · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8008939
16 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7901607
21 March 2024
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7886482
7 March 2024
CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7873372
7 August 2023
CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7744501
23 February 2023
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7640918
20 January 2023
CCSSC Examination · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7624350
5 August 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7525450
20 July 2022
PSC B · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7511149
20 January 2022
CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7382828
8 July 2021
CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7249176
7 January 2021
CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7120810
15 July 2020
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7006772
1 July 2020
CCSSC Examination · PSC A
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6984455
9 December 2019
CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6869766
10 August 2017
ISPS II Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6227537
30 July 2015
CCSSC Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5198578
4 June 2014
CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4876779
18 February 2014
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4801341
13 February 2014
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4799770
17 July 2013
PII Safety Exam · CCSSC Examination · MTSA Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4651178
4 March 2013
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4542974
24 January 2013
CCSSC Examination · MTSA Verification · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4521493
3 October 2012
MTSA Verification · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4450435
4 April 2008
NPV Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3177855
17 November 2006
Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2823731
13 March 2006
PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2711656
28 June 2005
MTSA Verification · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2406706
29 June 2004
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2115514
6 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060594
30 April 2004
Uninspected Other
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2056370
8 April 2003
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1811040
24 May 2000
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 47725
25 April 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 647857
5 April 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 182821
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2025
Resolved
Adequate provisions should be made to facilitate cleaning, inspection and maintenance of machinery installations including boilers and other pressure vessels.
PSCOs witnessed a 02 sec droplets of water from the port side generator water cooling pump due to a faulty cap.
CCSSC 2.24.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Received via email images and video evidence replaced cap on the port side generator where no water can be seen coming from the replaced cap. See documents for supporting files.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 September 2024
Resolved
A main source of electrical power of sufficient capacity to supply all electrical services necessary for normal operation and under emergency conditions. The main service generator is incapable of providing enough power for the normal operation of the ship and the use of the emergency fire pump simultaneously. CITE: CCSSC 2.33.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the generator produce enough power for the required functions.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 September 2024
Resolved
A self-contained emergency source of electrical power should be provided. The vessel's secondary main generator is inoperable. CITE: CCSSC 2.34.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the generator start and maintain power.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 September 2024
Resolved
The main fire pump should be capable of delivering water for fire fighting purposes. PSCO was unable to verify if the main fire pump was operational due to the condition of the generators as listed above. CITE: CCSSC 3.3.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Received report from flag testifying to the functionality of the generator. PSCO observed the main fire pump deliver water for fire fighting purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 September 2024
Resolved
Hydrostatic release units should be serviced at intervals not exceeding 12 months. The starboard liferaft's hydrostatic release expired in March of 2024. CITE: CCSSC 4.8
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: Vessel was equipped with a new hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2024
Resolved
AIS must be maintained in effective operating condition, which includes the continual operation of AIS at all times while the vessel is underway. The vessel's AIS is currently inoperable and is incapable of operating continuously while underway.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2024
Resolved 4 October 2024
Resolution: AIS antenna was replaced, restoring the continual operation of the AIS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2024
Resolved
A minimum of two inspections of the outside of the ship's bottom should be carried out during any five year period. Ship's last dry dock was in June of 2019. Ship was issued an extension to their dry dock date which expired on the 15th of August, 2024. CITE: CCSSC 1.10.1.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 November 2024
Resolved 27 May 2025
Resolution: Received dry dock completion report. Completed in Cartagena, Colombia.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 25 September 2024
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan is on the ship. The ship currently does not have a garbage management plan.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 October 2024
Resolved 4 October 2024
Resolution: Vessel was found to have a garbage management plan.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 25 September 2024
Resolved
When garbage us discharged to a reception facility, the record must contain the following information: the estimated amount of each category of garbage discharged, described by volume in cubic meters. The estimated amount of each category of garbage was not recorded.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 September 2024
Resolved 25 September 2024
Resolution: Vessel's master was informed that they will need to record the amount of each category of garbage and will do so moving forward.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 March 2024
Resolved
In every ship there should be provided a sufficient number of approved portable fire extinguishers to the satisfaction of the administration. One fire extinguisher was found to be inoperable.
CCSSC 3/3.91.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 16 April 2024
Resolution: A 20 pound fire extinguisher, type ABC was installed onboard MANCHENIL BAY in comppliance with Class Rules and Fire Safety Control Plan.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 January 2023
Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location. The vessels fire detection alarm panel is not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2023
Resolved 23 February 2023
Resolution: Cleared by facetime call with [name withheld] alarms and newly installed panel.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 January 2023
Resolved
The capacity in which the holder of a certificate is authorized to serve shall be identified in the form of an endorsement. The vessel's master as well as the chief engineer do not have an administration endorsement.
Action required: 10 - Deficiency Rectified
Due 20 January 2023
Resolved 20 January 2023
Resolution: Flag State endorsements issued prior to PSCO departure.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2023
Resolved
Fire extinguishers shall be periodically examined and subjected to such tests as the administration may require. The vessel's CO2 fire extinguisher cylinders are past their annual test date.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2023
Resolved 23 February 2023
Resolution: Accepted Class document and photo evidence of inspected bottles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2022
Resolved
Arrangements for the storage distribution and utilization of the oil fuel should be such as to ensure the safety of the ship and persons on board. Oil tank for main engines in engine room leaking from inspection ports (2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2022
Resolved 3 August 2022
Resolution: Received photos from vessel representative, documenting the repairs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 July 2020
Resolved
The satellite EPIRB and VHF EPIRB shall be capable of floating free if the ship sinks and of being automatically activated when afloat. It was observed that the bracket housing the vessels EPIRB was broken and no longer held the EIPRB in place. The vessel was currently housing the EPIRB within the pilot house.
Cite:CCSS Code CH. 5.3.3.3 Action:16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 15 July 2020
Resolution: Vessel received a new EPIRB bracket and hydrostatic release.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2020
Resolved
After any survey of the ship under 1.10 has been completed, no significant change shall be made in the structural arrangement, machinery, equipment and any other items covered by the survey, without permission of the Administration. The audible indicator for the vessels on board alarm system located on the bridge was inoperable.
Cite:CCSS Code CH 1.11.2 Action:16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 15 July 2020
Resolution: Vessel repaired the alarm with a new part.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 10 August 2017
Resolved
0199- The Caribbean Cargo Safety Certificate shall be drawn up in the models given in the annexes. The certificate on board was missing endorsement pages. Specifically attesting to the endorsement for inspections of outside the ships bottom. CCSSC - Ch 1.14 50AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 9 December 2019
Resolution: Vessel was able to produce the full recently-issued CCSSC with all endorsement pages.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 17 July 2013
Resolved
0120-Load Lines-A periodical survey/inspection within 3 months of each annual anniversary date of the ILLC shall be conducted. Annual inspections are not documented on current/valid ILLC (6903711-2370962-001). Previous ILLC onboard documents annual inspections. Class to correct admin error. 66 ICLL Art. 14
Action required: 705 - Other - as specified
Due 19 January 2014
Resolved 18 February 2014
Resolution: Vessel received valid current International Loadline Certificate.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 January 2013
Resolved
0100 - Documentation - Fire control plans should be kept up to date. Plan indicates an emergency generator for its emergency source of power. Admin to verify and update as appropriate fire control plan and attest to a secondary (emergency) source of power onboard. CCSSC CH3 Part A 3.13
Action required: 705 - Other - as specified
Due 7 February 2013
Resolved 4 March 2013
Resolution: Received, reviewed and accepted Class report from Overseas Marine Certification Services.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 October 2012
Resolved
1581 - The position of rudder should be indicated on bridge. Vessel did not have rudder angle indicating on bridge. CCSSC 2.33.8. Action 50b.
Due 2 November 2012
Resolved 24 January 2013
Resolution: Reviewed and accepted class report from American Bureau Of Shipping that the rudder angle indicator was installed on bridge. CCSSC 2.33.8 and confirmed rudder angle indicator was operational.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 4 April 2008
Resolved
Found overspeeds to be set below manufacturers setting. Classification society ABS is to conduct satisfactory operational testing of the port/starboard main engines and provide the report to Coast Guard for approval prior to operating as a tug vessel in U.S. waters.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 6 April 2008
Resolution: ABS reexamined overspeed shutdown and operationally tested, deemed satisfactory.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 4 April 2008
Resolved
Provide CG 2692 within the required time limit, explaining the cause and corrective actions to ghost overspeed tripping of the main engines prior to operating as a tug vessel in U.S. waters.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 6 April 2008
Resolution: Received CG-2692