MAURY USCG vessel records Sign in
← All vessels

SWAN

SWAN is a 1994 freight ship. The Coast Guard has recorded 13 inspections since 1995, most recently in December 2003, along with 6 deficiencies and 2 operational controls.

Records from 1995 to 2003. Most recent: inspection, 9 December 2003.

Built
1994
Last inspected
9 December 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9100126 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
422970
Flag
NETHERLANDS
—
Maury page id
psix-422970

Inspections, by type

…with no type recorded9
Years with a record 8 calendar years (1995–2003)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2839 - Regulatory (Subpart C or D), Gross Ton
1609 - Regulatory (Subpart C or D), Net Ton
4303 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

9 December 2003 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2086826
8 June 2003 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1812311
8 January 2003 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1727742
21 October 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1693236
16 September 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1676338
24 May 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1623405
16 April 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 12723
16 April 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 288973
27 March 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 276112
9 March 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 426197
9 September 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 407621
10 August 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 394033
13 April 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 377162

Deficiency record · 6

Lifesaving › Line-Throwing Appliances
Issued 21 October 2002 Resolved
Line throwing device is expired as of August 2002. LEGACY COMPONENT DESC: Projectiles
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 June 2003
Resolution: Went O/B to check all line throwing devices. All 4 found in good order, expiration date 2005.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 May 2002 Resolved
Provide tech report attesting to the proper operation of the gyro compass.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2002
Resolution: Received tech report attesting to the proper operation of the gyro compass.
Construction/Loadline
Issued 16 April 2001 Resolved
Outter oil shaft seal appears to be leaking (sheen in water). Class to address problem and ship to submit proposal for repairs to USCG Activities Baltimore @ [phone withheld]. (Chief Engineer added approximatly 5 liters during voyage)
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Construction/Loadline
Issued 27 March 2000 Resolved
Affect permanent repairs to the 10" main deck fracture, located in way of #1 cargo hold fwd stbd side, to the satisfaction of class and attending Coast Guard Marine Inspector.
Condition: Unknown
Due 29 March 2000
Resolved 30 March 2000
Lifesaving
Issued 27 March 2000 Resolved
Vessel's class society surveyor to attest to the serviceability of the rescue and liferaft davit system falls, which appear not to be in compliance with SOLAS 74 III/19.4.
Condition: Unknown
Due 29 March 2000
Resolved 30 March 2000
Construction/Loadline
Issued 10 August 1996 Resolved
DECK LINE MARK SAME COLOR AS HULL. REMARK DECK LINE IN CONTRASTING COLOR TOHULL, PORT AND STARBOARD SIDES, IN ACCORDANCE WITH INTERNATIONAL CONVENTION OF LOADLINES, 1966, PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996

Ownership record