MAURY USCG vessel records Sign in
← All vessels

SYMPHONY

SYMPHONY is a 1994 freight ship. The Coast Guard has recorded 30 inspections since 1995, most recently in May 2017, along with 8 deficiencies and 4 operational controls.

Records from 1995 to 2017. Most recent: inspection, 3 May 2017.

Built
1994
Last inspected
3 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9113381 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
423042
Flag
PHILIPPINES
—
Maury page id
psix-423042

Inspections, by type

…with no type recorded17
Years with a record 12 calendar years (1995–2017)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15500 - Convention (Subpart B), Gross Ton
7901 - Convention (Subpart B), Net Ton
24166 - Dead Weight, Ton
30579 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

3 May 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6138016
25 July 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3278698
19 July 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3272850
15 July 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3268994
14 July 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3267663
11 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3261243
8 July 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3261190
24 April 2008 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3191144
10 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2905007
23 March 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2893358
21 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2606506
21 February 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2588980
9 February 2006 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2582273
17 March 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756368
29 November 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1711312
18 March 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494582
4 March 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1491029
8 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281801
27 February 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275251
30 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 431269
22 April 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 427595
27 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 417700
28 January 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 191440
28 January 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765999
23 May 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 404036
15 February 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 400482
21 May 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 391229
18 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 386041
30 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 381128
25 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 377789

Deficiency record · 8

Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 15 July 2008 Resolved
MSU Galveston received report of ARPA failure. Vessel placed on Operation Control requiring proper repairs and submission of technician's report and Master attestation prior to departure from the Houston/ Galveston COTP zone.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2008
Resolution: Local OCMI received technician''s report attesting to the repair and proper operation of the vessel''s ARPA. Vessel is released from OP Control.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 14 July 2008 Resolved
Received a report from the vessel requesting a inbound deviation for the ARPA onboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2008
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 11 July 2008 Resolved
Vessel reported an inoperable ARPA Radar.
Due 23 July 2008
Resolved 25 July 2008
Resolution: Received class report from NKK satisfying requirement.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 10 April 2007 Resolved
Vessel failed to report upon arrival into the WHALESOUTH MSR area.
Condition: Unknown
Due 10 April 2007
Resolved 10 April 2007
Resolution: Issued LOW
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 March 2007 Resolved
Approximately 8 '' long soft patch was found on wasted section of the aux engine / generator sea water return line which leads to the overboard discharge. Ensure temporary or permanent repairs are satisfactory.
Action required: 705 - Other - as specified
Due 25 March 2007
Resolved 25 March 2007
Resolution: Recieved class report attesting to repair of soft patch.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 21 March 2006 Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System while transiting into the Port of Brunswick, Ga.
Condition: Unknown
Due 21 March 2006
Resolved 21 March 2006
Resolution: Issued LOW
Engineering › Diesel Engine (auxiliary) › Valve
Issued 9 February 2006 Resolved
Emergency generator fuel tank piping does have shut off valve outside of space, provide means to stop fuel supply to mergence generator from outside the space in accordance with SOLAS Chapter-II/2 Regulation 4.2.2.3.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2006
Resolution: ECEIVED AX AND PHOTOGRAPHS FROM MASTER, A FUEL STOP HAS BEEN INSTALLED.
Construction/Loadline › Markings
Issued 4 March 2002 Resolved
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 18 March 2002
Resolved 18 March 2002
Resolution: Loadline painted white.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.