MAURY USCG vessel records Sign in
← All vessels

SEA BREEZE

SEA BREEZE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1995, most recently in August 2025, along with 98 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1995 to 2025. Most recent: inspection, 26 August 2025.

Built
1995
Last inspected
26 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5676
423073
Flag
UNITED STATES
367799670
Maury page id
psix-423073

Inspections, by type

…with no type recorded2
Years with a record 26 calendar years (1995–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 20 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6631MMSI 367799670 · active · compulsorily equipped · granted 14 July 2017, expires 14 July 2027 · licensed under a name not among this hull’s recorded names (not shown)
WDF4789MMSI 367455870 · expired · compulsorily equipped · granted 8 June 2010, cancelled 8 August 2020
WDE5676MMSI 367370140 · expired · compulsorily equipped · granted 25 July 2008, cancelled 29 September 2018
WDC6790MMSI 367061370 · expired · compulsorily equipped · granted 10 August 2005, cancelled 10 October 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCR8266MMSI 366678750 · expired · compulsorily equipped · granted 24 May 1995, cancelled 30 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

26 August 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8218604
27 August 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7981140
20 August 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7981134
15 August 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7767911
23 August 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7554892
26 May 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7455417
19 August 2021 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7277718
21 August 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7032185
13 August 2020 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7023596
29 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6789434
21 September 2018 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6545679
10 October 2017 Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6304722
22 May 2017 DAPI Audit · COI Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6152539
16 July 2015 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5185816
13 June 2012 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4343864
13 July 2011 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4079966
23 February 2010 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3684931
23 February 2010 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3685041
16 July 2009 Annual Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3536388
26 April 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2924565
31 May 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2666460
18 May 2006 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2647473
14 December 2004 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2258976
1 November 2004 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2232973
25 May 2004 Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2064039
26 June 2003 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1842184
9 October 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1686577
1 October 2002 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1682319
18 May 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432509
31 August 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1052648
20 June 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410348
25 June 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1437565
5 October 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423091
20 May 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 791477
12 August 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781615
29 April 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094787
31 May 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191447
14 June 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191453
27 April 1995 Plan Review "T" Boat · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853508

Deficiency record · 98

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2025 Resolved
Electrically bond both independent fuel tanks to a common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 16 September 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 August 2025 Resolved
Provide a visual indicator for the port bilge high level alarm (audible alarm works).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 16 September 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 May 2022 Resolved
Expired hydrostatic on the EPIRB
Action required: 10 - Deficiency Rectified
Resolved 26 May 2022
Resolution: Narrative stated the EPIRB was replaced by the end of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2022 Resolved
Vessel missing required amount of life jackets. Provide additional to meet COI requirements.
Action required: 705 - Other - as specified
Resolved 15 August 2023
Resolution: Cleared def at next Annual Inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 August 2021 Resolved
Provide required Employee Assistance Program and associated training to all crew members, including supervisory training for masters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 16 September 2021
Resolution: EAP training provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 August 2021 Resolved
Provide adequate and up-to-date edition of Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 16 September 2021
Resolution: Coast Pilot 4 downloaded to masters' phones.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 August 2020 Resolved
Provide an adult life jacket for each person carried on board. The vessel’s COI states it can carry a maximum of 51 total people (49 passengers and 2 crew). There are only 43 total adult life jackets on board. Vessel may only carry 41 passengers until an additional 8 adult life jackets are provided. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 August 2020 Resolved
Provide a total of 6 hand red flare distress signals and 6 hand orange smoke distress signals (or their authorized substitute). The vessel had a total of 4 hand red flare distress signals and 0 hand orange smoke distress signals on board. 46 CFR 180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 21 August 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 August 2020 Resolved
Make the starboard side bilge high level visual alarm operational. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2020 Resolved
Provide 1 10-B:C fire extinguisher at the operating station. 46 CFR 181.500
Action required: 10 - Deficiency Rectified
Resolved 21 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2020 Resolved
Batteries must be free from exposure to water splash or spray. Provide an adequate cover strap on the starboard after battery box to prevent the battery from being exposed to water splash or spray. 46 CFR 183.350(b)
Action required: 10 - Deficiency Rectified
Resolved 21 August 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 August 2020 Resolved
Grind back damaged gelcoat/fiberglass on the starboard bow and renew. Prior to credit Hull Exam.
Action required: 705 - Other - as specified
Resolved 30 September 2020
Resolution: Vessel rep provided photos of the damaged area on the starboard bow taken back to good FRP. Inspected final repair
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 August 2020 Resolved
Make watertight the penetrations in the vessel's stern that are used for running the outboard engine controls.
Action required: 10 - Deficiency Rectified
Resolved 30 September 2020
Resolution: Vessel rep repaired on the spot by sealing the penetration with 5200.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 August 2019 Resolved
Provide valid COD for vessel. Previous COD expired on 31JUL2019.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2019
Resolution: Orginal COD onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2019 Resolved
Replace gasoline fuel lines and fuel filters. Fuel lines must be USCG Type A1, A2, B1, or B2. Fuel filters must be constructed of steel and strainer bowls must be highly resistant to mechanical damage or thermal damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2019
Resolution: All fuel hoses replaced with USCG Type A1 hoses.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 August 2019 Resolved
Provide FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2019
Resolution: New FCC radio safety certificate.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 August 2019 Resolved
Log required drills in vessels log book. (EPIRB, MOB, Fire).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Logs recorded on new vessel log book.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2019 Resolved
Replace battery for floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Battery replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 August 2019 Resolved
Provide tide and currents tables for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Pubs onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 August 2019 Resolved
STBD navigation light must be properly mounted. Currently ziptied to railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Fixture properly re-attached.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 August 2019 Resolved
Repair/replace visual indications on bilge high water alarms at operating station (Port and STBD side).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Both alarm indicators replaced and operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2019 Resolved
Provide 03 fire buckets, 01 missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Bucket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2019 Resolved
Ground both Port and STBD fuel tanks to common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Both tanks grounded to battery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2019 Resolved
Secure all battery boxes to vessel to prevent shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: All batteries secured.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 August 2019 Resolved
Wiring for VHF radio is loose and not of a marine grade, replace wiring and ensure proper connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Wiring replaced with boat cable and secured properly to panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2019 Resolved
Each battery terminal shall have a max of 4 connections, 02 battery terminals had 5+ connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Terminals cleaned up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2019 Resolved
Fill cover on STBD tank missing screw, repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2019
Resolution: Screw replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2019 Resolved
Conduct Design Verification Test Procedure (DVTP) for vessels electronic propulsion control system. Test should include analysis of the loss of power to the control system. Provide attending Marine Inspector with manufactures testing procedures. Vessel is equipped with 02 250hp Suzuki Outboards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2019
Resolution: DVTP conducted, operated as intended.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 October 2018 Resolved
Stanchions, seating and canopy legs have heavy corrosion near bases that have resulted in wastage holes. Submit repair proposal to local OCMI prior to conducting repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 15 October 2018 Resolved
Repair securing points on embarkation ladder, aluminum rings are worn past 50%.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2018 Resolved
BOTH INSTALLED ENGINES MUST OPERATE PROPERLY. STARBOARD ENGINE INOP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2018 Resolved
BATTERIES MUST BE FREE OF CORROSION, PROTECTED FROM SHIFTING, COVERED. BATTERIES UNDER CONSOL ARE NOT INSTALLED PROPERLY.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2018 Resolved
PORT SIDE AMIDSHIP BILGE PUMP NON OPERATION. REPAIR/ REPLACE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 October 2018 Resolved
VESSEL MISSING REQUIRED PUBLICATIONS. COAST PILOT, LIGHT LIST, TIDES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2018 Resolved
VESSEL MISSING EMERGENCY INSTRUCTION LIST
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 October 2018 Resolved
VESSEL DID NOT HAVE MAN OVER BOARD AND FIRE DRILL LOG. CREATE LOG.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2018 Resolved
VESSEL MUST CONDUCT UNDERWAY DRILLS AND MANUVERING WITH COAST GUARD INSPECTOR ON BOARD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 September 2018 Resolved
Conduct required annual inspection. Vessel did not undergoing annual inspection with 3 months before or after anniversary date (25MAY2017)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2018
Resolution: Vessel conducted annual inspection.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 9 August 2017 Resolved
Vessel owner has failed to comply with timelines give on CG-835's issued on 25MAY17 and 31JUL17.
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 21 November 2017
Resolution: complied with CG-835s
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 July 2017 Resolved
Provide plans to OCMI to install deck rail courses at 4' intervals or equivalent at stern and bow deck rails.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 21 November 2017
Resolution: Plans supplied and approved. Rail courses installed.
Construction/Loadline › Hull › Side Shell
Issued 31 July 2017 Resolved
Repair USCG marked areas of port hull to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 July 2017
Resolution: Proper repairs made, woven matting laid down and resin applied.
Documentation › Certificates/Documents › FCC SSL
Issued 25 May 2017 Resolved
Provide FCC station license and Operator permit.
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 20 July 2017
Resolution: FCC safety radio certificate provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 May 2017 Resolved
Provide proof of enrollment in drug testing program for all crew members/captains.
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 31 July 2017
Resolution: Proof of enrollment provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 May 2017 Resolved
Provide GPS and MMSI# input for VHF.
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 31 July 2017
Resolution: New VHF with GPS input installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 May 2017 Resolved
Properly mark vessel name on both port and starboard bow.
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 31 July 2017
Resolution: Name of vessel labeled on port/star bow.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 25 May 2017 Resolved
Provide adequate number of PFD's as per COI (49). Vessel has 30 serviceable PFD's, vessel is restricted to carriage of 28 adult passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2017
Resolved 16 November 2017
Resolution: New PFDs onboard
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 July 2015 Resolved
New Owner had not received new COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2015
Resolution: Owner had new COD.
Stability › Incline Test › General
Issued 16 July 2015 Resolved
Vessel had not received stability letter addendum for new AAWP. Required owner to submit for one of the acceptable changes for new stability calcs.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 8 September 2015
Resolution: Owner submited for passenger reduction. Issued stability letter addendum reflectign reduction.
Stability › Incline Test › General
Issued 16 July 2015 Resolved
Owner replaced both outboard engines. Owner must submit documentation of weights for new and old motors to ensure weight change is not greater than 2%.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 8 October 2015
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 July 2015 Resolved
make permanent repairs to ladders into port and starboard hulls.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 28 July 2015
Resolution: Ladders repaired.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 July 2015 Resolved
make port and starboard aft transom conduits for electrical watertight.
Action required: 705 - Other - as specified
Due 28 July 2015
Resolved 28 July 2015
Resolution: provided caulking and made watertight.
Construction/Loadline › Penetrations › Valve Flange
Issued 16 July 2015 Resolved
Replace raw water thru hull valve for toilet
Due 17 August 2015
Resolved 28 August 2015
Resolution: valve replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2015 Resolved
Remove dead end wiring throughout vessel
Due 17 August 2015
Resolved 28 August 2015
Resolution: wires removed.
Engineering › Bilge Water Management System › Pump
Issued 16 July 2015 Resolved
Replace head space sump pump and make watertight
Due 17 August 2015
Resolved 28 July 2015
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2015 Resolved
Make engine mounting bolts port side watertight
Due 17 August 2015
Resolved 28 July 2015
Construction/Loadline › Penetrations › Bottom Plug
Issued 16 July 2015 Resolved
Make head space bulkhead penetrations watertight.
Due 17 August 2015
Resolved 28 July 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 July 2015 Resolved
As an excursion vessel, does not have 4" courses for rails as required at embarkation points. Required vessel to add 2 courses to each embarkation point.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2015
Resolution: Vessel had added extra courses
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 16 July 2015 Resolved
Found that vessel did not have installed high water level alarms as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2015
Resolved 22 September 2015
Resolution: Vessel installed high water alarms
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2015 Resolved
Mast head light was malfunctioning, replace/fix as appropriate, prior to operating at night.
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 8 October 2015
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 July 2015 Resolved
stowage locations did not have number of lifejackets marked as required
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 11 September 2015
Resolution: Stowage locations marked
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 July 2015 Resolved
Company did not have specific drug and alcohol testing program.
Due 8 October 2015
Resolved 8 October 2015
Communications › Radio Communications › EPIRB
Issued 16 July 2015 Resolved
Vessel did not have valid registration for the EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2015
Resolved 11 September 2015
Resolution: Epirb Registered
Communications › Radio Communications › EPIRB
Issued 16 July 2015 Resolved
Vessel did not have valid hydrostatic release for epirb
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2015
Resolved 11 September 2015
Resolution: hydrostatic release installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 July 2015 Resolved
Vessel did not have full COI and stability letter posted as required.
Due 8 October 2015
Resolved 8 October 2015
Documentation › Certificates/Documents › FCC SSL
Issued 16 July 2015 Resolved
Vessel did not have valid ship station license
Due 8 October 2015
Resolved 8 October 2015
Documentation › Certificates/Documents › FCC SSL
Issued 16 July 2015 Resolved
No crew members had a valid marine radio operators permit.
Due 8 October 2015
Resolved 8 October 2015
Documentation › Markings/Placards › Warning Signs
Issued 16 July 2015 Resolved
Vessel did not have complete set of emergency instructions posted.
Due 8 October 2015
Resolved 8 October 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 June 2012 Resolved
Replace wing nuts on batteries with locking type nuts.
Condition: Improper Installation
Due 13 June 2012
Resolved 24 June 2012
Resolution: Master installed proper locking washers amd nuts.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 June 2012 Resolved
Install proper brackets for hand held fire extinguishers.
Condition: Placed in Improper Service
Due 13 July 2012
Resolved 26 June 2012
Resolution: Master installed approved brackets for all fire extinguishers on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 February 2010 Resolved
Valid COI not onboard vessel
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 3 June 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 February 2010 Resolved
Valid COD not onboard vessel
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 3 June 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 February 2010 Resolved
Vessel master unaware of company drug program, no proof of enrollment available
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2010
Resolved 3 June 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 February 2010 Resolved
Fire extinguisher out of service
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2010
Resolved 3 June 2010
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 24 July 2009 Resolved
Vessel operators and crew must provide valid documentation in regards to first aid and CPR training.
Due 24 July 2009
Resolved 25 July 2009
Resolution: Vessel rep and master provided valid first aid and CPR cards.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 July 2009 Resolved
Replace/re-certify portable B-I fire extinguisher onboard vessel.
Due 24 July 2009
Resolved 25 July 2009
Resolution: B-1 fire extinguisher has been replaced with new extinguisher.
Lifesaving › Lifefloat › Painter
Issued 24 July 2009 Resolved
Replace buoyant apparatus w/ painter and lines due to severe deterioration from the environment.
Condition: Damaged By Earlier Event
Due 24 July 2009
Resolved 25 July 2009
Resolution: Both life floats with lines have been replaced to the satisfaction of the Marine Inspector
Documentation › Logs/Records › Logbook (official)
Issued 16 July 2009 Resolved
Vessel needs to provide official log book to document training and implement crew training on fire fighting and life saving.
Condition: Improper/Lack of Maintenance
Due 24 July 2009
Resolved 25 July 2009
Resolution: Vessel has drill log book and procedures in place for crew.
Engineering › Bilge Water Management System › Pump
Issued 16 July 2009 Resolved
Replace secondary bilge pump w/ an operational unit. Remove units onboard that do not operate correctly.
Due 24 July 2009
Resolved 25 July 2009
Resolution: Manual bilge suction tubes have been replace with portable battery operated pump.
Lifesaving › Lifefloat › Paddle
Issued 26 April 2007 Resolved
Label paddles with vessel name.
Due 11 May 2007
Resolved 7 May 2007
Communications › Radio Communications › EPIRB
Issued 26 April 2007 Resolved
Re-located EPIRB to an unobstructed, float-free location.
Due 26 April 2007
Resolved 7 May 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2007 Resolved
Label bilge high level alarms.
Due 11 May 2007
Resolved 7 May 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 April 2007 Resolved
Separate storage of children's and adult lifejackets.
Due 11 May 2007
Resolved 7 May 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 April 2007 Resolved
Provide proof of enrollment in drug/alcohol testing consortium for vessel's crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2007
Resolved 7 May 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 May 2006 Resolved
Provide U.S. Coast Pilot to remain onboard vessel.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 26 May 2006
Engineering › Gasoline Engine (propulsion) › Exhaust Outlet (2 stroke)
Issued 18 May 2006 Resolved
Prove proper operation of outboard engine when power head is reinstalled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2006
Documentation › Logs/Records
Issued 1 October 2002 Resolved
Provide proof that MIS report was submitted to CGHQ for the 2001 calendar year. LEGACY COMPONENT DESC: MIS Form
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 1 October 2002 Resolved
Renew/replace wasted ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Lifesaving › Buoyant Apparatus
Issued 1 October 2002 Resolved
Replace both 18 person Buoyant Apparatus with Life Floats having an aggregate capacity of 50% of the total persons allowed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2002
Resolved 4 October 2002
Resolution: Corrected
Documentation › Safety Management System
Issued 1 October 2002 Resolved
Initiate a training logbook in accordance with 46 CFR 185.420. LEGACY COMPONENT DESC: Potential Emergency Situations ID Procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Navigation › Collision/Grounding Avoidance
Issued 1 October 2002 Resolved
Replace cloudy side light lenses. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Communications › Radio Communications
Issued 1 October 2002 Resolved
Register vessel's EPIRB with NOAA. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2002
Resolved 4 October 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 October 2002 Resolved
Renew retro-reflective tape on PFDs as needed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 1 October 2002 Resolved
Provide properly sized fire extinguisher for existing bracket or provide properly sized bracket for existing fire extinguisher.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 4 October 2002
Resolution: Corrected
Lifesaving
Issued 20 June 2000 Resolved
Replace/repair waterlight for ring buoy & properly configure line.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 20 June 2000 Resolved
Initiate log/record for monthly test of Lifesaving Equipment, including test of EPIRB.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 20 June 2000 Resolved
Replace waterlight mounting brackets for both BA. Replace retro-reflectivetape.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 20 June 2000 Resolved
Service portable fire extinguishers.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Construction/Loadline
Issued 25 June 1999 Resolved
Install bilge high water alarms in accordance with 46 CFR part 182.530.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999

Casualty record · 1

31 May 2006Routine · role: Involved in a Marine Casualty · activity 2666460
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record