MAURY USCG vessel records Sign in
← All vessels

LOOKOUT

LOOKOUT is a 1995 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1995, most recently in May 2026, along with 59 deficiencies.

Records from 1995 to 2026. Most recent: inspection, 5 May 2026.

Built
1995
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCR6593
423138
Flag
UNITED STATES
368471990
Maury page id
psix-423138

Inspections, by type

…with no type recorded3
Years with a record 27 calendar years (1995–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 29.0 ft × 6.0 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENE MARINE, INC · YARMOUTH, ME, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portBEAUFORT, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9530MMSI 368471990 · active · compulsorily equipped · granted 5 May 2026, expires 5 May 2036
WDI7026MMSI 367724630 · expired · compulsorily equipped · granted 31 March 2016, cancelled 6 June 2026
WCR6593MMSI 367022070 · expired · compulsorily equipped · granted 3 March 2005, cancelled 18 July 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

5 May 2026 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8349943
5 August 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8202891
23 April 2025 Administrative Inspection · Deadweight Survey · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8117181
11 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8091571
29 July 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7956664
26 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7701931
15 March 2023 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7650864
15 July 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7507462
20 April 2021 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7175944
3 August 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7001013
10 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6937925
4 June 2019 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6703797
6 May 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6678741
18 April 2019 Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656390
20 August 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6517505
10 November 2017 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6319769
28 August 2017 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6243960
29 March 2017 Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6096111
12 May 2016 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5875378
26 August 2014 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4959908
18 March 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3435658
10 June 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3227362
7 June 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2944974
29 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2908891
30 May 2006 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2664135
13 June 2005 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2389347
6 April 2005 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2327554
10 June 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2094406
23 September 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1982191
2 July 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1833225
1 October 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1688391
3 June 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1625659
9 October 2001 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1376763
4 June 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1382264
11 October 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418778
13 June 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462108
8 May 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386812
21 July 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 160323
6 May 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445473
30 April 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445474
8 July 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 712043
6 July 1998 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1128778
29 May 1998 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1126281
27 April 1998 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 791075
28 August 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1120389
28 July 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 781002
4 April 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424447
4 May 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404159
4 May 1996 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424446
1 November 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1188840
22 August 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1189410
23 June 1995 Initial Certification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 880446

Deficiency record · 59

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 March 2023 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspections of the hull structure including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Make port and stbd voids forward of the collision bulkhead ready for examination.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 20 March 2023
Resolution: Port and Stbd void accessed via inspection ports on the main deck; all sat
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 March 2023 Resolved
A vessel must be provided with a main steering gear that is: (1) Of adequate strength. Both port and starboard showed cracking and possible deterioration. Make proper repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2023
Resolution: Repairs on port and starboard rudder completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 March 2023 Resolved
At each subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspections of the hull structure including the following: (1) Inspection of all accessible parts of the exterior. Presence of cracking on forward port and starboard underneath cover boards. Make available for further examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2023
Resolution: Cover boards accessed via accessed ports and found all satisfactory with no apparent rot.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Make proper repairs to stbd aft hull IVO rudder gudgeon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 April 2023
Resolution: Proper repairs in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Make repairs to stbd transom scoop as identified by USCG.
Action required: 705 - Other - as specified
Resolved 3 April 2023
Resolution: Made repairs to stbd transom scoop to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Make repairs to port transom scoop as identified by USCG.
Action required: 705 - Other - as specified
Resolved 3 April 2023
Resolution: Made repairs to port transom scoop to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service intended. Unstep mast with associated attachments and make available for inspection; intervals specified in enclosure (1) to NVIC 02-16.
Action required: 705 - Other - as specified
Resolved 5 May 2023
Resolution: Credit for Mast unstep to conduct full CG inspection was given this day.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 August 2022 Resolved
Repairs to the equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] were made to the sheared tapered pin on the mast step plate. Submit repair plan for approval from the CG. Make effective repairs to include non-destructive test to the attending Marine Inspector. Conduct underway operational test under sail. 701-Vessel operations under power permitted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 August 2022
Resolution: Original weld on the plate was ground out and prepped with bevel. Pin was pressed in the plate and beveled to take weld root. Pin and plate was weld and ground down flush. Dye penentrant test conducted; all sat. Underway operational test; sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The 03 portable fire extinguishers were not properly stowed in the approved bracket. Provide brackets for all fire extinguishers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Brackets installed for all portable fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2022 Resolved
Each stowage container for life jackets must not be capable of being locked. Remove closure latch from STBD passenger compartment hatch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Closure latches were removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Provide proper donning placards for both adult and child sized life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Life jacket donning placards posted for both type onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Provide three 2.5 gallon fire buckets or modify existing fire buckets to capacity 2.5 gallons
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Fire buckets were modified to carry 2.5 gallons.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2022 Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable;. Provide additional clamps on flexible fuel hoses IVO of fuel tanks.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Additional clamps installed on fuel lines.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 August 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible;. Current chart on board is outdated or corrections made. Provide updated charts for operating areas.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Updtaed charts are onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove dead ended live wire from port-side battery switch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Dead ended wire was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Remove small splice on wire on portside battery switch and attach the wire directly with proper connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: The splice was removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2022 Resolved
The regulations in this part provide a means to minimize the use of intoxicants by merchant marine personnel and to promote a drug free and safe work environment. Properly implement current drug/alcohol policy on board the vessel; crew members knowledge of designated employee representative, crew-members awareness of Employee Assistance information, and hot line numbers posted in a commons space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 15 August 2022
Resolution: Drug and alcohol policy properly placed onboard the vessel. Evidence of supervisor training provided. Crewmembers aware of 800 number for EAP program.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 August 2022 Resolved
A vessel must comply with the applicable requirements for any radio as set forth in 47 CFR 80. Current on board VHF radio is not properly integrated with GPS coordinates or MMSI. In addition conduct proper radio check IAW MSIB 20-20.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 15 August 2022
Resolution: MMSI installed the VHF radio. GPS is now communicating with VHF radio with coordinates position. Conducted proper radio check.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 August 2022 Resolved
The design of standing rigging on a sailing vessel must be suitable for the intended service. Properly verify that the check stays are installed IAW the rigging plan or provide a third party rigging surveyor for evaluation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 8 September 2022
Resolution: All reccomendations on stated on the rigging inspection were completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2022 Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation. The approved sail plan from 16Jun95 must be maintained onboard in a suitable location at all times.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 8 September 2022
Resolution: The approved sail plan from 16Jun95 is now onboard the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021 Resolved
First aid kit missing items. Provide ammonia inhalants.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 12 May 2021
Resolution: Provided ammonia inhalants
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021 Resolved
Electrical terminals and wires underneath pilothouse are corroded. Properly clean and make ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 12 May 2021
Resolution: Terminal were cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021 Resolved
Tighten wires and hardware on portside battery selector switch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2021
Resolved 10 May 2021
Resolution: Hardware were properly tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021 Resolved
Install retro-reflective material on life ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 12 May 2021
Resolution: Retro-reflective material on the life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021 Resolved
Properly secure lifeline around the body of the life ring buoy
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 12 May 2021
Resolution: Life line secured around the body of the ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021 Resolved
Install corrosion resistant clip on the water light line and secure around the body of the ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 12 May 2021
Resolution: Corrosion resistant clip was installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 August 2020 Resolved
Provide lifejacket donning placard onboard
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 19 August 2020
Resolution: The vessel owner installed new lifejacket donning placard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 August 2020 Resolved
Provide marine charts for the vessel's operating area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 19 August 2020
Resolution: Vessel owner provided new marine chart.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 June 2019 Resolved
The vessel has rot in seating and modification to existing structure ivo maindeck and hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 11 August 2020
Resolution: Starboard rotted seating was repaired in kind using Mohagany plywood overlaid with FRP.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 6 May 2019 Resolved
Vessel did not have a valid Radio Station Lic onboard during this inspection.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 10 May 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2019 Resolved
The vessels fire-fighting servicing was not conducted for this year.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2019
Resolved 10 May 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 May 2019 Resolved
The vessel bilge system audible alarm was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 10 May 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2019 Resolved
The forward combo light lens was damaged. Additionally, none would energize. No night time operations and or retify within 30 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 May 2019
Resolved 10 May 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2019 Resolved
Determine the extent of rot and make proper repairs to vessel seating on main deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2019
Resolved 17 October 2019
Resolution: This is captured on another inspection activity 6703797 still outstanding with a 12/31/2019 due date.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 August 2018 Resolved
Vessel EPIRB battery was expired 04/2018 without servicing.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 August 2018
Resolved 4 September 2018
Resolution: Owner purchased new Cat I Epirb and registered with NOAA, satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2018 Resolved
Lifejacket clip was identified as inoperative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2018
Resolved 4 September 2018
Resolution: O/O replaced damaged life jackets inkind.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 August 2018 Resolved
Vessel is missing posted instructions for life-jackets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2018
Resolved 4 September 2018
Resolution: O/O placed instructions onboard for life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 27 August 2018 Resolved
Emergency instructions are missing at the helm.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2018
Resolved 4 September 2018
Resolution: O/O installed emergency instructions ivo helm.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 August 2018 Resolved
COI not posted onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2018
Resolved 4 September 2018
Resolution: O/O installed COI onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2018 Resolved
Missing a fire bucket.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2018
Resolved 4 September 2018
Resolution: O/O installed and properly labeled missing fire bucket.
Sail Rigging › Mast Step › Base
Issued 26 August 2014 Resolved
Tha Mast step pin was backed out to the cotter pin and there was no washer/spacer between the mast step pin and the cootter pin.
Condition: Improper Installation
Due 26 September 2014
Resolved 4 September 2014
Fire Fighting › Fire Bucket › Quantity
Issued 26 August 2014 Resolved
One 2.5 gallon fire bucket with lanyard was missing.
Due 26 August 2014
Resolved 4 September 2014
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 26 August 2014 Resolved
The stern light on the vessel was broken. Replace fixture and remount new stern light.
Condition: Damaged By Earlier Event
Due 26 September 2014
Resolved 15 September 2014
Resolution: New LED stern light installed
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 29 March 2007 Resolved
Replace vent caps on portable fuel tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 18 June 2007
Resolution: Owner installed new vent caps for fuel tanks
Construction/Loadline
Issued 8 May 2000 Resolved
MAKE FIBERGLASS REPAIRS INWAY OF PORT AND STARBOARD RUDDERS WHERE WEARING ON THE HULL.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
MARK EMERGENCY ESCAPE HATCHES ON PORT AND STARBOARD SIDE.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Engineering
Issued 8 May 2000 Resolved
MAKE GASOLINE FUEL STOWAGE COMPATMENTS OPEN TO THE ATMOSPHERE OR INSTALL FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Construction/Loadline
Issued 8 May 2000 Resolved
MAKE FIBERGLASS REPAIRS INWAY OF CENTERBOARDS PORT AND STARBOARD SIDE.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Documentation
Issued 6 July 1998 Resolved
A VIOLATION OF 46 CFR 176.100 IN THAT THE VESSEL'S CERTIFICATE OF INSPECTION EXPIRED ON 23 JUNE 1998 AND THE VESSEL HAS OPERATED SINCE THAT DATE WITH MORE THAN SIX (06) PASSANGERS.
Condition: Unknown
Due 7 July 1998
Resolved 8 July 1998
Construction/Loadline
Issued 6 July 1998 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS AS REQUIRED BY 46 CFR 182.530.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Lifesaving
Issued 28 July 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE/INSTALL 406 MHZ EPIRB TO THE SATISFACTION OF AN ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Documentation
Issued 28 July 1997 Resolved
PROVIDE PROOF OF ENROLLMENT IN CURRENT DRUG TESTING PROGRAM NO LATER THAN 04 AUGUST 1997.
Condition: Unknown
Due 28 July 1997
Resolved 28 July 1997
Lifesaving
Issued 28 July 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE RING BUOY FOR SUPPLEMENTAL PRIMARY L/S.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Documentation
Issued 28 July 1997 Resolved
PRIOR TO OPERATING MORE THAN 1000 FT FROM SHORE, PROVIDE PROOF OF VALID RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Lifesaving
Issued 28 July 1997 Resolved
PROVIDE REPLACEMENT WEAK-LINK FOR TWENTY (20) PERSON B/A NO LATER THAN 04 AUGUST 1997.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Lifesaving
Issued 28 July 1997 Resolved
STENCIL BUOYANT APPARATUS WITH TOTAL PERSONS (CAPACITY) NO LATER THAN 28 AUGUST 1997.
Condition: Unknown
Due 28 July 1997
Resolved 28 July 1997
Lifesaving
Issued 28 July 1997 Resolved
PROVIDE RETRO-REFLECTIVE MATERIAL ON ALL RING BUOYS NO LATER THAN 28 AUGUST1997.
Condition: Unknown
Due 28 July 1997
Resolved 28 July 1997
Accommodation/Occupational Safety
Issued 23 June 1995 Resolved
MARK EMERGENCY ESCAPES AS PER 46 CFR 185.30-15.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Accommodation/Occupational Safety
Issued 23 June 1995 Resolved
PROVIDE PLACARD THAT READS " NO PASSENGERS BEYOND THIS POINT " FOR THE AFT GATE AREA ON EACH HULL.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.