Records from 1996 to 2023. Most recent: inspection, 9 March 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
9 March 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648467
2 November 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7343809
29 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7185963
5 October 2020
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071671
6 May 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949162
20 April 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6941409
27 February 2020
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916796
17 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814361
29 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6652151
2 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6394672
24 October 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6294355
7 April 2017
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6119876
29 March 2016
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5842924
10 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5830690
6 October 2015
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5736787
19 May 2014
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4865298
12 May 2014
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4832668
22 February 2010
Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3663114
21 April 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3440868
20 May 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3211662
26 April 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3194050
20 March 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167078
27 February 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3150236
15 November 2007
Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3093263
15 May 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2930865
24 April 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2910377
25 April 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2632856
8 November 2005
Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2524178
18 February 2005
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2295418
9 April 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2041031
12 December 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1959641
14 April 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1770103
7 February 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491213
12 December 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399749
20 March 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060375
23 February 2001
Inclining Experiment · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1370030
24 February 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815955
23 December 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437653
19 October 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 790931
8 March 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195882
10 September 1998
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468475
9 July 1998
Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 796414
20 October 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1111564
23 September 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378168
13 September 1996
Hull Examination · Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1356045
1 August 1996
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1087769
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requriements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which it is engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a) prior to operating / carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2020
Resolved
Bilge pump wiring for fuel tank space incorrectly spliced. All wire splices must be sealed appropriately to deter water intrusion and corrosion. Repair in accordance with NFPA 70.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2020
Resolved 6 May 2020
Resolution: O/O submitted pictures documenting satisfactory repair to these wires with environmentally sealed splices.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2020
Resolved
Port engine raw water intake valve bonding wire broken. All electrical connections must be secure and free of excessive corrosion. Repair bonding wire in accordance with NFPA 70.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2020
Resolved 6 May 2020
Resolution: O/O submitted pictures of the satisfactory repair of the bonding wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2020
Resolved
Aft engine room bilge pump 100% clogged. All bilge suction inlets must be clear of debris. Clean and test bilge suction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2020
Resolved 6 May 2020
Resolution: O/O submitted pictures of a 100% clean engine room bilge and bilge suction strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2020
Resolved
13 adult life jackets found with weathered retro tape. Replace retro tape. Passenger count reduced to 39 until corrected to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2020
Resolved 6 May 2020
Resolution: O/O submitted photographs of replaced retro tape on 13 adult sized life jackets.
Fire Fighting › Fire Hoses › Condition
Issued 3 May 2017
Resolved
Fire hose corroded, multiple holes found.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2017
Resolution: Replaced fire hose with new.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 3 May 2017
Resolved
Provide current local Notice to Mariners.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 15 May 2017
Resolution: Provided updated Local Notice to Mariners.
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 7 April 2017
Resolved
Ground wire missing from port side strut.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 15 May 2017
Resolution: Installed new ground wire.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 April 2016
Resolved
Vessel did not possess means of conducting alcohol testing. Provide approved means to conduct alcohol testing. Vessel is restricted to trips of less than 2 hours until resolved.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified alcohol testing means and not expired.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 April 2016
Resolved
Vessel's DAPI policy was from 2005. Provide current copy of vessel's DAPI policy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified DAPI policy as current.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 April 2016
Resolved
Company's EAP hotline information not posted. Post required EAP hotline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified EAP hotline posted.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 19 April 2016
Resolved
Vessel possessed outdated copy of Inland Navigation Rules. Provide current copy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified Nav Rules as current.
Navigation › Piloting/Steering › Marine Charts
Issued 19 April 2016
Resolved
Vessel's charts were not current and corrected. Provide current/corrected charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified marine charts as current.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2016
Resolved
Lighting fixture in the forward berthing area was inoperable and was missing a protection guard. Remove or replace light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified light as operational and guarded.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 April 2016
Resolved
Stbd berthing area did not have a smoke detector. Provide approved smoke detector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified smoke detector as UL approved and operational.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 April 2016
Resolved
Vessel did not have a DSC enabled VHF radio. Replace radio with DSC enabled set.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified VHF radio has DSC capability.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 April 2016
Resolved
Vessel had 5 adult lifejackets and 5 child life jackets with damaged/worn retro reflective tape. Replace tape as necessary. Vessel limited to 49 total persons until resolved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verfied all PFD's had renewed retroflective tape in affected areas.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 April 2016
Resolved
Life floats retro-reflective tape was faded/damaged in areas. Replace where needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified lifefloat retroflective tape renewed.
Lifesaving › Lifefloat › Lifeline
Issued 19 April 2016
Resolved
Life floats lifelines were dry rotted in spots. Check all lines and replace needed line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified lifefloat lines were renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 April 2016
Resolved
There were no rails or lines across the top of the ladder on the upper deck. Install line or rail across the opening at the top of the ladder.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified line across the top of the ladder.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2016
Resolved
The name of the vessel on the ring buoy on the main deck and upper deck was faded/not on buoy. Retro-reflective tape was also faded in areas. Renew tape and name of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified ring buoy had renewed retroflective tape and vessel name re-stenciled.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2016
Resolved
The port side lighting fixture in the lazarette space was not secured in place and hanging by the wires. The protective guard was also missing. Re attach light and install protective guard/cage over glass.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified light in lazarette space as operational, properly mounted, and guarded.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2016
Resolved
Two lights under the bulwark on deck were missing the protective guard over the glass. Install guard/cage over glass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified guards over glass.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2016
Resolved
Wiring and piping supports were wasted/broken or missing all together in lazarette space, engine room, and under the port side bench in the accommodation space. Properly support all wires and pipes with metal hangers at least every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified all wiring supported every 24 inches.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 19 April 2016
Resolved
A bonding wire in the tank room was not attached and laying in the bilge. Re attach bonding wire as designed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified bonding wire attached.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 19 April 2016
Resolved
Two auto pilot lines were deteriorated in the engine room. Replace lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified auto pilot lines replaced.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 19 April 2016
Resolved
The MSD tank overboard valve was not locked. Lock valve or breaker box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified lock on MSD tank valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2016
Resolved
Dead ended wires were found in engine room and on aft of cabin on main deck. Remove or properly cap and enclose all dead ended wires.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified all dead-ended wires were removed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 April 2016
Resolved
The emergency flashlights at the operating station and access to the engine room had dead batteries. Replace batteries for all portable emergency lights.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 26 May 2016
Resolution: Verified flashlights operational.
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2015
Resolved
Fuel shut-off valve handles were wasted. Replace fuel shut off valve handles IAW 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 18 November 2015
Resolution: Resolved to the satisfaction of the Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 9 November 2015
Resolved
Vertical engine mounts were not properly secured. Secure vertical engine mounts IAW 182.20-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 18 November 2015
Resolution: Resolved to the satisfaction of the Marine Inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 November 2015
Resolved
Electrical fixtures in tank room were loose. Secure electrical fixtures in tank room IAW 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 18 November 2015
Resolution: Resolved to the satisfaction of the Marine Inspector.
Engineering › Bilge Water Management System › Strainer
Issued 12 May 2014
Resolved
Missing strainer for bilge suction in lazarette. Provide suitable strainer having an open area not less than three times the area of the bilge pipe per 46 CFR 182.25-59(b)
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 19 May 2014
Resolution: Strainer was in place and operational in the lazarette. def cleared.
Communications › Alarms/Indicators › Fire Alarm
Issued 12 May 2014
Resolved
Replace batteries for smoke detectors in accomodation spaces as required by 46 CFR 181.450
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 19 May 2014
Resolution: Batteries were replaced in smoke detectors and tested sat. Def Cleared.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2014
Resolved
Floating water light for ring life buoy shall have a lanyard at least 3 ft in length, but no more than 6 ft in length per 46 CFR 180.70 (d)(2)
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 19 May 2014
Resolution: Lanyard was replace with correct size lanyard. Def Cleared.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 22 February 2010
Resolved
Provide temperature/pressure device for hot water heater that meets 46 CFR 182.320.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 March 2010
Resolved 10 March 2010
Resolution: Installed temp/pressure device for hot water heater.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 February 2010
Resolved
Provide means to secure engine room ventilation per 46 CFR 182.465(c)
Action required: 705 - Other - as specified
Due 22 March 2010
Resolved 10 March 2010
Resolution: Provided covers to secure engine room ventilation.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2010
Resolved
Provide properly equipped first-aid kit per 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2010
Resolved 10 March 2010
Resolution: Provided properly equipped first-aid kit.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 April 2009
Resolved
Replace expired batteries for waterlights on lifefloats as per 46 CFR 185.726
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 28 April 2009
Resolution: Batteries replaced.
Lifesaving › Lifefloat › Pendant
Issued 21 April 2009
Resolved
Replace grablines on the starboard lifefloat as per 46 CFR 180.010
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 28 April 2009
Resolution: Grablines replaced.
Lifesaving › Lifefloat › Serviceable
Issued 21 April 2009
Resolved
Repair or replace forward bottom and port lifefloat as per 46 CFR 185.700
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 28 April 2009
Resolution: Area repaired on lifefloat.
Lifesaving › Lifefloat › Painter
Issued 21 April 2009
Resolved
Repair broken welds on sea painter container for lifefloats as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 28 April 2009
Resolution: Welds repaired on container.
Electrical › Electric Supply System (service) › Cable
Issued 27 February 2008
Resolved
Provide cutoff switches for all batteries in engine room as per 46 CFR 183.354.
Due 27 March 2008
Resolved 20 March 2008
Electrical › Electric Generation Source (service) › Generator
Issued 27 February 2008
Resolved
Clean/provide data plate for #1 generator and prove both generators have been derated as per 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 27 March 2008
Resolved 20 March 2008
Engineering › Bilge Water Management System › Interface Detector
Issued 27 February 2008
Resolved
Properly level the bilge high level alarms and bilge pump indicator lights as per 46 CFR 182.530.
Due 27 March 2008
Resolved 20 March 2008
Lifesaving › Lifebuoys › Serviceable
Issued 27 February 2008
Resolved
Replace the grab line for the life ring on the 2nd deck as per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 27 March 2008
Resolved 20 March 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 February 2008
Resolved
Provide up to date current tables as per 46 CFR 184.420.
Due 27 March 2008
Resolved 20 March 2008
Construction/Loadline › Hull › Side Shell
Issued 15 November 2007
Resolved
Repair all blisters on the hull and make ready for inspection as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 20 November 2007
Resolution: Repaired all blisters on the hull and made ready for inspection as per 46 CFR 176.800.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 November 2007
Resolved
Check all hydraulic lines on the steering gear for leaks. Repair leaks as per 46 CFR 182.600.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 20 November 2007
Resolution: Checked all hydraulic lines on the steering gear for leaks. Repaired all leaks as per 46 CFR 182.600.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 November 2007
Resolved
Replace the strut bearings for the aft tail shaft struts port and starboard as per 46 CFR 176.670.
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 21 November 2007
Resolution: Replaced the strut bearings for the aft tail shaft struts port and starboard as per 46 CFR 176.670.
Fire Fighting › Means of Escape › Blocked
Issued 24 April 2007
Resolved
Make the emergency hatch match the escape route as required by 46 CFR 177.500
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: The emergency hatch was turned around to match the escape route.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 24 April 2007
Resolved
Provide a ladder for use with the emergency hatch as required by 46 CFR 177.500
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: A ladder was install at the emergency hatch.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2007
Resolved
Stow the lifefloats so that they do not interfere with the use of the search light as requiredby 46 CFR 176.800
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: Stowage for the life floats were shifted over to the starboard side approximately 4 inches.
Lifesaving › Lifebuoys › Stowage
Issued 24 April 2007
Resolved
properly mount the ring lifebuoy outside the pilot house as required by 46 CFR180.72
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: The ring lifebuoy was properly stowed in a mount design for the ring.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2007
Resolved
Provide a Coast Guard approved first aid kit as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: A new Coast Guard approved first aid kit was provide.
Lifesaving › Lifefloat › Float Free
Issued 24 April 2007
Resolved
Remove sharp edges on the stowage legs on the lifefloats as required by 46 CFR 176.800
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: The sharp edges on the legs for the life floats stowage were sanded down smooth.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 April 2007
Resolved
Properly secure all loose insulation in the overhead of the engine room as required by 46 CFR 176.800
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: The edges of the insulation was taped.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 24 April 2007
Resolved
Make repairs to the excessive leaks on the starboard main engine as required by 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: New head and valve cover gaskets were install.
Fire Fighting › Fire Pumps › Pressure
Issued 24 April 2007
Resolved
Prove operation of the pressure gauge for the fire pump as required by 46 CFR 181.300
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: A new liquid filled gage was installed and tested.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 April 2007
Resolved
Prove operation of emergency lighting as required by 46 CFR 183.4342. The vessel is restricted from carrying overnight trips until this item is cleared.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: Upon loss of power in the berthing compartment the emergency lighting activated.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 24 April 2007
Resolved
Provide a safety line for use during man overboard operations as required by the vessel's emergency instructions.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 15 May 2007
Resolution: A safety harness with a line was provided.
Documentation › Logs/Records › Logbook (official)
Issued 25 April 2006
Resolved
Provide current training log with current entries in accordance with 46 CFR 185.420
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Provided current training log with current entries.
Documentation › Logs/Records › Logbook (official)
Issued 25 April 2006
Resolved
Provide a equipment maintenance record in accordance with 46 CFR 188.702
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Provided a equipment maintenance record.
Documentation › Logs/Records › Logbook (official)
Issued 25 April 2006
Resolved
Provide a bridge log with current and required entries in accordance with 46 CFR 185.702
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Provided a bridge log with current and required entries.
Documentation › Safety Management System › Response Measures Documentation
Issued 25 April 2006
Resolved
Provide a voyage plan in accordance with 46 CFR 185.503
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Provided a voyage plan.
Lifesaving › Lifefloat › Paddle
Issued 25 April 2006
Resolved
Properly attach paddles to the lifefloats with the vessels name and retro reflective tape in accordance with 46 CFR 185.604
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Properly attached paddles to the lifefloats with the vessels name and retro reflective tape.
Lifesaving › Lifefloat › Markings
Issued 25 April 2006
Resolved
Properly mark life floats with vessels name and retro reflective tape in accordance with 46 CFR 185.604
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Properly marked life floats with vessels name and retro reflective tape
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 April 2006
Resolved
Make proper repair to emergency lighting in the forward berthing.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Made proper repairs to emergency lighting in the forward berthing.
Communications › Radio Communications › EPIRB
Issued 25 April 2006
Resolved
Replace hydrostatic release on the EPIRB 46 CFR 185.740
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Replaced hydrostatic release on the EPIRB
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 April 2006
Resolved
Clean lifejacket stowage areas prior to re-stowing the life jackets as req by 46 CFR 180.78
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: cleaned lifejacket stowage area.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 25 April 2006
Resolved
Remove all of the lose gear from the berthing or the overnight count will be taken away.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Removed all lose gear from the berthing.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 April 2006
Resolved
Remove all oil from the bilges in the engine room as req. by 46 CFR 176.830
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Removed all oil from the bilges in the engine room.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2006
Resolved
Provide a first aid kit that is approved under 46 CFR 160.041
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Provided a proper first aid kit.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 April 2006
Resolved
Properly Mark the emergency escape in accordance with 46 CFR 185.606
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Properly Marked the emergency escape.
Engineering › Bilge Water Management System › Piping
Issued 25 April 2006
Resolved
Properly support the bilge piping in the tank compartment.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Properly supported the bilge piping in the tank compartment.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 April 2006
Resolved
Clean all life jackets prior to stowage.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Cleaned all life jackets prior to stowage.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2006
Resolved
Properly support all electrical wiring throughout the engine room and remove the dead end cables in accordance with 183.340.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 1 May 2006
Resolution: Properly support all electrical wiring throughout the engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 8 November 2005
Resolved
Repair area of hull delamination located amidships starboard side bottom FRP plating in accordance with NVIC 8-87 to the satisfaction orf the attending marine inspector.
Due 14 November 2005
Resolved 14 November 2005
Stability › Watertight Integrity › General
Issued 8 November 2005
Resolved
Renew gasket to anchor locker watertight access hatch in accordance with 46 CFR 171.24 to the satisfaction of the attending marine inspector.
Due 14 November 2005
Resolved 14 November 2005
Documentation › Logs/Records › Logbook (official)
Issued 21 February 2005
Resolved
Provide on board vessel lifesaving equipment maintenance records as required by 46 CFR 185.702
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 24 February 2005
Resolution: Lifesaving equipment maintenance record was provided as per 46 CFR 185.702 and found satisfactory.
Documentation › Logs/Records › Logbook (official)
Issued 21 February 2005
Resolved
Provide on board vessel a training log book as required by 46 CFR 185.420
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 24 February 2005
Resolution: Drill was conducted and training logbook was made available for inspection and found satisfactory.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 February 2005
Resolved
Provide proof of enrollment in a drug and alcohol testing program as required by 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Owner provided proof of enrollment to attending marine inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 February 2005
Resolved
Repair and prove operation of visual indicator for amidship bilge pump as required by 46 CFR 182.530 (c) to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Witnessed satisfactory operational test of visual indicator for bilge pump.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2005
Resolved
Provide cover to stern light assembly as per 46 CFR 183.420 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 24 February 2005
Resolution: Cover was provided for stern light.
Fire Fighting › Means of Escape › Blocked
Issued 21 February 2005
Resolved
Provide emergency escape hatch from passenger accommodation area that is operable from both sides as required by 46 CFR 177.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Dogs on hatch were replaced making hatch operable from both sides.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 February 2005
Resolved
Label emergency fuel shutoff as per 46 CFR 185.608 to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Emergency fuel shutoff was labeled and found in compliance with 46 CFR 185.608
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 February 2005
Resolved
Repair or renew remote fuel shutoff for fuel oil tank as required by 46 CFR 182.455 (b)(4) to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Valve was renewed and proven operational .
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 February 2005
Resolved
Renew bands securing non-metallic hose section of the fuel fill pipe as per 46 CFR 182.720 to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Bands were renewed and found in compliance with 46 CFR 182.720.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 21 February 2005
Resolved
Secure mircrowave oven to prevent shifting as per 46 CFR 184.220.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Microwave was removed from vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 February 2005
Resolved
Renew marking of vessel's name on lifebuoy as per 46 CFR 185.604 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Vessel name was remarked clearly and legibly.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 February 2005
Resolved
Provide operable non-corrosive clip to attach waterlight to lifebuoy as required by 46 CFR 180.70(d)(3).
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Owner renewed clip.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 February 2005
Resolved
Renew retroreflective material on lifefloat as per 46 CFR 185.604(h) to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Retroreflective material was renewed on lifefloats.
Lifesaving › Lifefloat › Painter
Issued 21 February 2005
Resolved
Secure lifefloat with painter to vessel as required by 46 CFR 180.137 (d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Painter was secured around lifefloat and attached to vessel via weak link.
Documentation › Certificates/Documents › FCC SSL
Issued 21 February 2005
Resolved
Provide on board vessel an FCC Safety Certificate as required by 46 CFR 184.502 and 47 CFR 80.905
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 8 November 2005
Resolution: Verified valid Safety Radio Certificate onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 21 February 2005
Resolved
Renew retroreflective tape on life buoys as per 46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2005
Resolved 24 February 2005
Resolution: Retroreflective material was renewed and found satisfactory.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 February 2002
Resolved
Repair starboard main diesel engine shutdown device so that engine secures when fixed gas fire extinguishing system is energized. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2002
Resolved 11 February 2002
Resolution: Visited vessel to inspect repairs. Owner replaced engine shutdown solenoid. Witnessed operational test of fixed fire system. All engines shut down when fixed system was tested.
Electrical
Issued 23 February 2001
Resolved
ELECTRICALLY HARD WIRE IN WASH DOWN PUMP IN ENGINE ROOM AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Accommodation/Occupational Safety
Issued 23 February 2001
Resolved
PROVE PROPER OPERATION OF EMERGENCY ESCAPE HATCH FROM MAIN DECK AS REQUIREDBY 46 CFR 177.500
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Engineering
Issued 23 February 2001
Resolved
LABEL EMERGENCY FUEL SHUT OFFS AS REQUIRED BY 46 CFR 185.608
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Electrical
Issued 23 February 2001
Resolved
PROVIDE PROPER ELECTRICAL WIRE INSULATION AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Electrical
Issued 23 February 2001
Resolved
PROPERLY SUPPORT AND INSULATE AMP METER SHUNT BAR IN ENGINE ROOM AS REQUIRED BY 46 CFR 183.340(P)
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Lifesaving
Issued 23 February 2001
Resolved
PROVIDE PROPER STOWAGE MARKINGS FOR LIFE JACKETS AS REQUIRED BY 46 CFR 180.78
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Lifesaving
Issued 23 February 2001
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46 CFR 184.610
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Electrical
Issued 23 February 2001
Resolved
REMOVE DEADENDED CABLE FROM FUEL TANK SPACE AS REQUIRED BY 46 CFR 183.340(P)
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Navigation
Issued 23 February 2001
Resolved
PROVIDE CURRENT CHARTS AND PUBLICATIONS AS RQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Accommodation/Occupational Safety
Issued 23 February 2001
Resolved
PROPERLY MARK UPPER DECK FOR MAXIMUM NUMBER OF PASSENGERS AS REQUIRED BY 46CFR 185.602
Condition: Unknown
Due 20 March 2001
Resolved 22 March 2001
Navigation
Issued 23 September 1997
Resolved
PROVIDE ON BOARD NAUTICAL PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Accommodation/Occupational Safety
Issued 23 September 1997
Resolved
PROVIDE HANDLES ON THE OUTSIDE OF THE FORWARD ESCAPE HATCH TO ENABLE THE HATCH TO BE OPENED FROM THE OUTSIDE. SEE 46 CFR 177.500(h).
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Lifesaving
Issued 23 September 1997
Resolved
RENEW LANYARD FOR LIFEFLOAT WATERLIGHT WITH 18' DARK SYNTHETIC LINE IN ACCORDANCE WITH 46 CFR 184.175(4).
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997