MAURY USCG vessel records Sign in
← All vessels

WEST SHORE

WEST SHORE is a 1947 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1985, most recently in March 2026, along with 123 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2026. Most recent: inspection, 2 March 2026.

Built
1947
Last inspected
2 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4252
Flag
UNITED STATES
367534580
Maury page id
psix-42321

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 29 calendar years (1985–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 30.0 ft × 7.3 ft
Registered tonnagegross 94 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING & DRY DOCK CO · STURGEON BAY, WI, UNITED STATES · built 1947
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
120 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4252MMSI 367534580 · active · compulsorily equipped · granted 9 June 2022, expires 12 June 2032
WCZ5929MMSI not assigned · expired · compulsorily equipped · granted 14 December 1999, cancelled 13 February 2010
WYP5043MMSI not assigned · expired · compulsorily equipped · granted 24 March 1995, cancelled 23 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 48

2 March 2026 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8332237
24 September 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8240566
21 July 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8193557
29 May 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8146946
9 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999064
29 August 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8004914
9 May 2024 Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913369
30 March 2023 Examination of Repairs · Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7741344
29 September 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7572702
30 August 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7300080
23 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296088
27 May 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7208068
2 November 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7088248
26 October 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7084763
1 October 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7069155
24 April 2019 COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6669579
14 November 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6580593
27 August 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6525310
22 September 2017 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6293005
19 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167484
26 April 2016 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5863809
20 January 2016 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5831546
11 June 2012 Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4451604
7 June 2012 Plan Review "T" Boat · Initial Certification · Deadweight Survey · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4419086
10 October 2001 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1461446
10 July 2001 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1068808
22 September 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408603
28 September 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1424818
22 December 1998 COI Inspection · Deadweight Survey
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1471364
18 September 1997 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1400645
24 April 1997 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1092627
17 April 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1081579
3 April 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1355205
25 May 1994 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1019718
2 May 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1434115
12 May 1993 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1144659
15 May 1992 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 959034
21 April 1992 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1270302
2 April 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1257904
3 May 1991 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 913813
1 May 1990 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1213865
6 April 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1209749
20 April 1988 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1035256
4 April 1988 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 891224
30 October 1987 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1024541
7 April 1987 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1328560
10 April 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1307741
17 April 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 981023

Deficiency record · 123

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 September 2025 Resolved
Fuel shut-offs need to be appropriately labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 28 October 2025
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025 Resolved
An oil line for the transmission was called out for suspected chafing. Remove the flexible hose and make available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 28 October 2025
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 September 2025 Resolved
Pin hole sighted in the fwd portion, stbd side just forward of collision bulkhead on main deck. Make temp repiars as agreed upon and make available for close inspection during winter lay-up.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 25 March 2026
Resolution: repaired, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2025 Resolved
Heavy scale and pitting was found below the fuel tank. Make available for inspection during winter layup.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 25 March 2026
Resolution: repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2025 Resolved
Found numerous oil leaks on the Main Diesel Engine which were saturating the main creating a fire hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 July 2025 Resolved
Found an excessive amount of oily slop in the vessel's engine room. High enough where the Master admitted to disabling the vessel's high water alarm panel to dismiss the nuisance alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 July 2025 Resolved
Found the rudder packing to be actively leaking water into the lazarette with approximately 75 gallons of water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 21 July 2025 Resolved
Found the sewage tank had overflowed into the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 July 2025 Resolved
Found the 110v light fixture in the forepeak mount broken and light dangling from the cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2025 Resolved
Found diesel fuel leaking from an improperly capped off fuel hose for an out of service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 August 2024 Resolved
PA system inop. Correct and demonstrate proper operation. Safety briefs must be given verbally until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 17 September 2024
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Clear head
Issued 29 August 2024 Resolved
Head inop due to holding lid deformation. Repair/replace holding tank lid; lock out head until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 17 September 2024
Resolution: lid replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2023 No resolution recorded
Bow thruster has multiple errors including generator side of genset inoperative, thruster electronic management system malfunctioning and pilothouse controller broken, needs to be replaced. Bow thruster must be locked out/tagged out, must not be used until repairs have been completed & satisfactory operation witnessed by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 28 September 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023 Resolved
Engineroom battery boxes and lids must be properly secured. Electrical safety covers must be provided for electrical connections. Some missing including cover over battery charger terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2023
Resolved 9 May 2024
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2023 Resolved
28 adult PFDs that were deteriorated were replaced with new PFDs.
Action required: 10 - Deficiency Rectified
Due 28 August 2023
Resolved 28 August 2023
Resolution: corrected prior to my departure.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 July 2023 Resolved
2nd deck concessionaire compartment has wastage on deck - make available for close inspection and C/R as called for. Maindeck & bulwarks wastage suspected on portside outboard of now removed temp head - make available for close inspection and C/R as called for.
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 9 May 2024
Resolution: repairs completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022 Resolved
Label for Child PFD's on the main deck had fallen off the storage container.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022 Resolved
Found crew work vests stowed in with passenger PFD's.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
Vessel has a HAZMAT endorsement but does not have onboard an overhead water sprinkler system installed in the hold where class 3 flammable liquids are stored. Submit plans for install to local OCMI for approval.
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 28 August 2023
Resolution: resolved, carriage of hazmat removed from COI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2022 Resolved
Vessel has two functioning emergency fuel shut offs but crew is unsure about which systems each shut off secures fuel to. Trace system and appropriately label fuel shut offs for the systems they secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2022 Resolved
Main deck life ring has DOT retro tape vs. SOLAS.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 September 2022 Resolved
Found an electric space heater duct taped to a table being used on the bridge. If heat is needed at the operating station, submit plans to this office for a more permanent solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected, heater removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
Bracket for main deck fire extinguisher is missing the bottom rubber strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2022 Resolved
Found one strobe light for life float with diminished capacity. Found the batteries hadn't been changed since 2020. Change out all batteries in float lights aboard this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 29 September 2022 Resolved
Found vessel using electronic chart plotter as it's primary means of navigation. Found electronic charts and software from 2015. Update charts and software to latest version.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022 Resolved
Label for Child PFD's on the main deck had fallen off the storage container.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022 Resolved
Found crew work vests stowed in with passenger PFD's.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
Vessel has a HAZMAT endorsement but does not have onboard an overhead water sprinkler system installed in the hold where HAZMAT is stored. Submit plans for install to local OCMI for approval.
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 28 August 2023
Resolution: resolved. carriage of hazmat removed COI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2022 Resolved
Vessel has two functioning emergency fuel shut offs but crew is unsure about which systems each shut off secures fuel to. Trace system and appropriately label fuel shut offs for the systems they secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2022 Resolved
Main deck life ring has DOT retro tape vs. SOLAS.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 28 August 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 September 2022 Resolved
Found an electric space heater duct taped to a table being used on the bridge. If heat is needed at the operating station, submit plans to this office for a more permanent solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected. heater removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
Bracket for main deck fire extinguisher is missing the bottom rubber strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2022 Resolved
Found one strobe light for life float with diminished capacity. Found the batteries hadn't been changed since 2020. Change out all batteries in float lights aboard this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 29 September 2022 Resolved
Found vessel using electronic chart plotter as it's primary means of navigation. Found electronic charts and software from 2015. Update charts and software to latest version.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 30 August 2021 Resolved
Vessel's primary means of navigation is the electronic charting system. Electronic charts have not been updated since 2015. Update electronic charts in operating area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 28 August 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2021 Resolved
vessel temporarily lost main propulsion system. Prove proper operation of the main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2021
Resolved 27 May 2021
Resolution: Company found fuel return line clogged and possible fuel vent blockage which caused vacuum in fuel tank which starved the MDE. Repaired and underway sea trials completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2020 Resolved
Maindeck Life Ring needs replaced. Horses chewed through the grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2020 Resolved
Electric outlet in the lazarette needs to be resecured to the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 1 October 2020 Resolved
Escape hatch from the engine room must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 2 November 2020
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 October 2020 Resolved
Old water inlet from engine room to sewage space needs to be plugged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 October 2020 Resolved
When Class 1 materials are being loaded, handled, or unloaded on a vessel, the vessel must exhibit the following signals: (a) By day, flag “B” (Bravo) of the international code of signals; and (b) By night, an all-round fixed red light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 23 August 2021
Resolution: Light & flag installed, installation & ops check approved/completed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 October 2020 Resolved
Lifefloats are being stowed in tiers of two without spacers. Found lifefloats stuck together. Replace spacers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 2 November 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2018 Resolved
Collision bulkhead must be watertight. Collision bulkhead is not watertight near the keel. Temporary repairs to be completed to consist of epoxy patch no later than 31 August 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 29 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2018 Resolved
Further to item 1, permanent repairs to collision bulkhead shall be carried out prior to operating in 2019 and before 15 May 2019, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 2 November 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 August 2018 Resolved
Hatches exposed to the weather must be watertight. The engine room emergency escape hatch is not watertight. Hatch must be made watertight before 3 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2018 Resolved
All cable must be installed in such a manner to avoid chaffing. Chaffing gear is required on electric cable to refrigeration unit before 26 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 2 May 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2018 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cable without supports shall be corrected before 26 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 2 May 2019
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 August 2018 Resolved
A weathertight door must be provided for each opening located in a deck house. The door to the engine room is not weathertight. Door must be made weathertight before 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 August 2018 Resolved
After loading and prior to departure, master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Master is unable to determine if bilges are dry, as per stability letter. Must provide means to check bilges by 26 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 14 November 2018
Resolution: Provided means to check spaces containing steering machinery and sewage tanks.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 27 August 2018 Resolved
Seats used to determine the number of passengers permitted must be secured to the deck, bulkhead, or bulwark. Seating on upper deck is missing bolts in the deck and must be secured by 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: seats properly secured.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 August 2018 Resolved
Vessel must carry adequate and up to date light list. Light list onboard is not up to date. Light list must be updated before 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: updated.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 August 2018 Resolved
Bilge suction lines must have check valve or stop-check valve. Bilge suction lines are missing check valves; check valves must be installed by 26 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 17 January 2019
Resolution: corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 22 September 2017 Resolved
Several wastage of hull bottom plating and related interneal framing and bulkheads, mostly from interior arising from inadequate internal coatings and long-term exposure to standing water. See narrative for extensive details. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2018
Resolved 28 May 2018
Resolution: See narrative.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 May 2017 Resolved
Properly mark E/R emergency exit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Marked.
Lifesaving › Lifefloat › Float Free
Issued 19 May 2017 Resolved
Install spacers between floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 May 2017 Resolved
Replace inop light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Replaced battery.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2017 Resolved
Remove or bolt down all permanent seating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Bolted down all seating.
Navigation › Piloting/Steering › Marine Charts
Issued 19 May 2017 Resolved
Update.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Updated.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 May 2017 Resolved
Replace cracked window pilothouse stbd side and cracked porthole main deck forward port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 15 June 2017
Resolution: Windows replaced.
Lifesaving › Lifefloat › Painter
Issued 26 April 2016 Resolved
Make individual attaching lines from life float to sea painter of sufficient length to launch individually prior to operating.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 26 April 2016
Resolution: Installed lines of appropriate length.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 April 2016 Resolved
Three child size life jackets are not serviceable. Limited to 130 passengers until replacement/repairs are on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 27 April 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 26 April 2016 Resolved
Replace hand operated petcock on primary fuel filter with mechanical type cocks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Electrical › Electric Generation Source (service) › Generator
Issued 26 April 2016 Resolved
Complete full load test on starboard generator prior to use.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 30 May 2016
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2012 Resolved
Hull plating severely wasted to less than 20" remaining of .25" original thickness, for 12-30" strip along both side of keel bar beneath fuel oil tank in 1st void space. This was cropped and inserted as per narrative in this activity.
Condition: Improper/Lack of Maintenance
Due 24 September 2012
Resolved 24 September 2012
Resolution: Corrected during this credit drydocking
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 August 2012 Resolved
In 1st void space, aft bulkhead and internal framing severely wasted. Aft 5 frames and aft bulkhead cropped and inserted to original. Corrected during this credit drydocking.
Condition: Improper/Lack of Maintenance
Due 24 September 2012
Resolved 24 September 2012
Resolution: Corrected during this credit drydocking.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 22 August 2012 Resolved
Stern tube severely wasted for entire length, replaced in kind with Schedule 80 grade A-53 piping during credit drydocking.
Condition: Improper/Lack of Maintenance
Due 24 September 2012
Resolved 24 September 2012
Resolution: Corrected during credit drydocking.
Construction/Loadline › Hull › Transverse Frame
Issued 10 October 2001 Resolved
Clean oil and debris from engine room bilge prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Construction/Loadline › Penetrations › Valve Flange
Issued 10 October 2001 Resolved
Replace the bilge suction line in the # 4 compartment prior to the compliance date.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 October 2001 Resolved
Replace broken windows (6) in pilot house with tempered glass prior to the compliance date.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 10 October 2001 Resolved
Conducted a credit re-inspection prior to any passenger or cargo operations.
Condition: Unknown
Due 15 March 2002
Resolved 15 March 2002
Engineering
Issued 10 October 2001 Resolved
Repair or replace propulsion shaft prior to completion of the hull exam andprior to the compliance date.
Condition: Unknown
Due 20 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 10 October 2001 Resolved
Repair wasted hull plate and blisters as marked prior to the completion of the hull exam.
Condition: Unknown
Due 20 October 2001
Resolved 31 October 2001
Engineering › Fuel Oil Service System › Valve
Issued 10 July 2001 Resolved
INSTALL REMOTELY OPERATED SHUT-OFF VALVES IN BOTH FUEL OIL SUPPLY LINES IN THE ENGINEROOM AND AS CLOSE AS PRACTICABLE TO THE BULKHEAD AS TO COMPLY WITH THE THE INTENT OF 46 CFR 182.455(B)(4), TO BE COMPLETED BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 August 2001
Resolved 18 August 2001
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 July 2001 Resolved
COMPLETE ANNUAL SERVICING AND INSPECTION OF PORTABLE AND SEMI-PORTABLE FIREEXTINGUISHERS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Construction/Loadline › Structures › Deck Plating
Issued 10 July 2001 Resolved
FOREPEAK BILGE MUST BE PROVIDED WITH A MEANS OF DEWATERING, EITHER WITH FIXED PIPING OR A PORTABLE PUMP AS PER 46 CFR 182.510(A), BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 July 2001 Resolved
BILGE PIPING PENETRATION IN COLLISION BULKHEAD IS WASTED THROUGH AND MUST BE EITHER REPLACED AS PER 46 CFR 182.510 OR BE ELIMINATED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. THIS MUST BE COMPLETED PRIOR TO OPERATING AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 10 July 2001 Resolved
CLEAN AWAY RUST, SCALE AND SEDIMENT FROM SEWAGE TANK IN WAY OF WASTED AREASAND PREPARE IT FOR FURTHER INSPECTION BY THE ATTENDING MARINE INSPECTOR. INSPECTION MAY REQUIRE THICKNESS GAGING IN WAY OF WASTAGE. THIS MUST BE COMPLETED BEFORE THE COMPLAINCE DATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 July 2001 Resolved
PRIOR TO OPERATING, INSTALL APPROVED FLOAT LIGHT AND LANYARD ON RING LIFE BUOY AS PER 46 CFR 180.70, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Documentation › Markings/Placards › Official Number (US)
Issued 10 July 2001 Resolved
REMOVE OUTDATED STABILITY LETTER FROM VESSEL AND PROPERLY POST VALID STABILITY LETTER IN PILOTHOUSE AS PER 46 CFR 176.306, BEFORE THE COMPLIANCEDATE.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Lifesaving
Issued 22 September 2000 Resolved
Test EPIRB every 30 days and log in bridge log as required by 46 CFR 185.728.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Lifesaving › Work Vest › General
Issued 22 September 2000 Resolved
Conducted a fire and man-overboard drill to the satisfaction of an attending marine inspector prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Lifesaving › Buoyant Apparatus › Lifeline
Issued 22 September 2000 Resolved
Stow buoynat apparatus pendants as per 46 CFR 160.010.4 prior to the compliance date.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Documentation
Issued 28 September 1999 Resolved
COI AND STABILITY LETTER NOT POSTED PROPERLY, CORRECTED DURING INSPECTION
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Engineering
Issued 28 September 1999 Resolved
FUEL SUPPLY HOSE DETERIORATED AND FITTING LEAK ON PORT S/S GENERATOR, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 28 September 1999 Resolved
PRIOR TO GETTING UNDERWAY, INSTALL AND PROPERLY REGISTER A CATEGORY 1, 406 MHZ EPIRB AS PER 46 CFR 180.64, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1999
Resolved 28 September 1999
Construction/Loadline
Issued 28 September 1999 Resolved
INSTALL AND PROVE OPERATION OF BILGE HIGH LEVEL ALARMS AS PER 46 CFR 182.530 BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1999
Resolved 28 September 1999
Lifesaving
Issued 28 September 1999 Resolved
PROVIDE CURRENT AND PROPERLY OUTFITTED FIRST AID KIT AS PER 46 CFR 184.710 BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1999
Resolved 28 September 1999
Lifesaving
Issued 22 December 1998 Resolved
LANYARDS AND GRAB-LINES EXCESSIVELY DETERIORATED ON BUOYANT APPARATUS, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Accommodation/Occupational Safety
Issued 22 December 1998 Resolved
INSTALL INSULATION LAGGING ON EXPOSED ENGINE EXHAUST PIPING ON CAR DECK, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Accommodation/Occupational Safety
Issued 22 December 1998 Resolved
CLEAN AND DEMONSTRATE PROPER OPERATION OF INSTALLED TOILETS, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Construction/Loadline
Issued 22 December 1998 Resolved
REMOVE OILY WASTE AND DEBRIS FROM ENGINEROOM BILGE, COMPLETED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
PROVIDE MACHINERY GUARD IN WAY OF FRESH WATER PUMP DRIVE COUPLING, CORRECTED DURING INSPECTION._x001C_
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
FLOAT LIGHT INOPERABLE ON BUOYANT APPARATUS, BATTERY RENEWED, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
RENEW DISTRESS SIGNALS, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
RENEW FLOAT LIGHT AND LANYARD FOR RING BUOY, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
RENEW WEAK LINK ON BUOYANT APPARATUS, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
REMOVE ALL CORK LIFE PRESERVERS FROM SERVICE (1 ADULT SIZE AND 5 CHILD SIZE) CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Navigation
Issued 22 December 1998 Resolved
PROVIDE CURRENT EDITION OF 46 CFR SUBCHAPTER T AND NAVIGATION RULES, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Documentation
Issued 22 December 1998 Resolved
PROVIDE STABILITY LETTER AND POST SAME IN WHEELHOUSE.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Engineering
Issued 22 December 1998 Resolved
MAIN ENGINE TACHOMETER INOPERABLE IN WHEELHOUSE, TO BE CORRECTED PRIOR TO OPERATING VESSEL AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Lifesaving
Issued 22 December 1998 Resolved
STOW CHILD SIZE LIFE REPSERVERS SEPARATELY FROM ADULT SIZE, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Documentation
Issued 22 December 1998 Resolved
DEMONSTRATE COMPLIANCE WITH DRUG TESTING REGULATIONS, COMPLETED DURING INSPECTOIN.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Engineering
Issued 18 September 1997 Resolved
Make repairs to exhaust leak on "Witty" diesel generator/fire pump/bilge pump combination.
Condition: Unknown
Due 1 October 1997
Resolved 17 October 1997
Engineering
Issued 24 April 1997 Resolved
MDE EXHAUST IN THE VEHICLE DECK AREA WASTED AND HOLED.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 24 April 1997 Resolved
CUTLASS BEARING RETAINER PLATE STUD SHEARED OFF. DRILL OUT REMAINING STUD AND RENEW SAME AS ORIGINAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 24 April 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Navigation
Issued 24 April 1997 Resolved
GOUGE AND WELD THE ERRODED WELDMENTS LOCATED ON THE STBD. SIDE OF THE RUDDER. REMOVE RUDDER DRAIN PLUGS AND DRAIN ACCUMULATED WATER.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 24 April 1997 Resolved
O/B VALVE LOCATED IN THE STBD. S/S GEN EXHAUST LINE FOUND TO HAVE A BROKEN STEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 3 April 1995 Resolved
REPLACE WORN STBD FUEL VENT SCREEN.
Condition: Unknown
Due 3 May 1995
Resolved 30 April 1995
Documentation
Issued 3 April 1995 Resolved
PROVIDE NEW VERSION OF OIL DISCHARGE PLACARD AND PROVIDE GARBAGE PLACARD AND WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 30 April 1995
Resolved 30 April 1995
Lifesaving
Issued 3 April 1995 Resolved
REPLACE OR CLEAN MISSING/DIRTY RETROREFLECTIVE TAPE ON PFD'S.
Condition: Unknown
Due 3 April 1995
Resolved 30 April 1995
Navigation
Issued 3 April 1995 Resolved
PROVIDE UP-TO-DATE/CORRECTED CHART OF AREA OF OPERATION, RULES OF THE ROAD,COAST PILOT, LIGHT LIST AND LOCAL NOTICE TO MARINERS. ONE COPY EACH OF CP,LL AND LNTM MAY BE PROVIDED AND STOWED AT COMPANY OFFICE, SO LONG AS NEEDEDINFORMATION IS MADE AVAILABLE TO EACH VESSEL AND ITS CREW.
Condition: Unknown
Due 30 April 1995
Resolved 30 April 1995
Lifesaving
Issued 2 May 1994 Resolved
No more than 241 passengers shall be carried until 3 additional lifejacketsare provided.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Lifesaving
Issued 2 April 1992 Resolved
complete underway drills.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Fire Fighting
Issued 4 April 1988 Resolved
SERVICE ALL PORTABLE,SEMI-PORTABLE AND FIXED FIRE EXTINGUISHERS IAW 46CFR 176.25-25.
Condition: Unknown
Due 4 April 1988
Resolved 4 April 1988
Fire Fighting
Issued 7 April 1987 Resolved
REPLACE BELT GUARD ON FIRE PUMP.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Deck/Cargo
Issued 7 April 1987 Resolved
CLEAN OUT BILGE IN ENGINEROOM.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Construction/Loadline
Issued 7 April 1987 Resolved
RADIUS TRANSVERSE FRAME MANHOLE IN #2 VOID.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Fire Fighting
Issued 7 April 1987 Resolved
CLEAN HOLES IN SPRINKLER SYSTEM PIPING ON CAR DECK.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 7 April 1987 Resolved
INSTALL BELT GUARD ON ISUZU GENERATOR.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Fire Fighting
Issued 10 April 1986 Resolved
HYDROSTATICALLY TEST ALL CO2 FIRE EXTINGUISHER BOTTLES.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 10 April 1986 Resolved
SOLDER ALL BATTERY TERMINAL CONNECTIONS.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Engineering
Issued 10 April 1986 Resolved
MARK EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986

Ownership record