07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 September 2025
Resolved
Fuel shut-offs need to be appropriately labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 28 October 2025
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025
Resolved
An oil line for the transmission was called out for suspected chafing. Remove the flexible hose and make available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 28 October 2025
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 September 2025
Resolved
Pin hole sighted in the fwd portion, stbd side just forward of collision bulkhead on main deck. Make temp repiars as agreed upon and make available for close inspection during winter lay-up.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 25 March 2026
Resolution: repaired, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2025
Resolved
Heavy scale and pitting was found below the fuel tank. Make available for inspection during winter layup.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 25 March 2026
Resolution: repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2025
Resolved
Found numerous oil leaks on the Main Diesel Engine which were saturating the main creating a fire hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 July 2025
Resolved
Found an excessive amount of oily slop in the vessel's engine room. High enough where the Master admitted to disabling the vessel's high water alarm panel to dismiss the nuisance alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 July 2025
Resolved
Found the rudder packing to be actively leaking water into the lazarette with approximately 75 gallons of water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 21 July 2025
Resolved
Found the sewage tank had overflowed into the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 July 2025
Resolved
Found the 110v light fixture in the forepeak mount broken and light dangling from the cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2025
Resolved
Found diesel fuel leaking from an improperly capped off fuel hose for an out of service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2025
Resolved 22 July 2025
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 August 2024
Resolved
PA system inop. Correct and demonstrate proper operation. Safety briefs must be given verbally until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 17 September 2024
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Clear head
Issued 29 August 2024
Resolved
Head inop due to holding lid deformation. Repair/replace holding tank lid; lock out head until repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 17 September 2024
Resolution: lid replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2023
No resolution recorded
Bow thruster has multiple errors including generator side of genset inoperative, thruster electronic management system malfunctioning and pilothouse controller broken, needs to be replaced. Bow thruster must be locked out/tagged out, must not be used until repairs have been completed & satisfactory operation witnessed by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 28 September 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
Engineroom battery boxes and lids must be properly secured.
Electrical safety covers must be provided for electrical connections. Some missing including cover over battery charger terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2023
Resolved 9 May 2024
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2023
Resolved
28 adult PFDs that were deteriorated were replaced with new PFDs.
Action required: 10 - Deficiency Rectified
Due 28 August 2023
Resolved 28 August 2023
Resolution: corrected prior to my departure.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 July 2023
Resolved
2nd deck concessionaire compartment has wastage on deck - make available for close inspection and C/R as called for.
Maindeck & bulwarks wastage suspected on portside outboard of now removed temp head - make available for close inspection and C/R as called for.
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 9 May 2024
Resolution: repairs completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022
Resolved
Label for Child PFD's on the main deck had fallen off the storage container.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022
Resolved
Found crew work vests stowed in with passenger PFD's.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022
Resolved
Vessel has a HAZMAT endorsement but does not have onboard an overhead water sprinkler system installed in the hold where class 3 flammable liquids are stored. Submit plans for install to local OCMI for approval.
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 28 August 2023
Resolution: resolved, carriage of hazmat removed from COI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2022
Resolved
Vessel has two functioning emergency fuel shut offs but crew is unsure about which systems each shut off secures fuel to. Trace system and appropriately label fuel shut offs for the systems they secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2022
Resolved
Main deck life ring has DOT retro tape vs. SOLAS.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 September 2022
Resolved
Found an electric space heater duct taped to a table being used on the bridge. If heat is needed at the operating station, submit plans to this office for a more permanent solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected, heater removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022
Resolved
Bracket for main deck fire extinguisher is missing the bottom rubber strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2022
Resolved
Found one strobe light for life float with diminished capacity. Found the batteries hadn't been changed since 2020. Change out all batteries in float lights aboard this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 29 September 2022
Resolved
Found vessel using electronic chart plotter as it's primary means of navigation. Found electronic charts and software from 2015. Update charts and software to latest version.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022
Resolved
Label for Child PFD's on the main deck had fallen off the storage container.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2022
Resolved
Found crew work vests stowed in with passenger PFD's.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022
Resolved
Vessel has a HAZMAT endorsement but does not have onboard an overhead water sprinkler system installed in the hold where HAZMAT is stored. Submit plans for install to local OCMI for approval.
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 28 August 2023
Resolution: resolved. carriage of hazmat removed COI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2022
Resolved
Vessel has two functioning emergency fuel shut offs but crew is unsure about which systems each shut off secures fuel to. Trace system and appropriately label fuel shut offs for the systems they secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2022
Resolved
Main deck life ring has DOT retro tape vs. SOLAS.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 28 August 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 29 September 2022
Resolved
Found an electric space heater duct taped to a table being used on the bridge. If heat is needed at the operating station, submit plans to this office for a more permanent solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected. heater removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022
Resolved
Bracket for main deck fire extinguisher is missing the bottom rubber strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2022
Resolved
Found one strobe light for life float with diminished capacity. Found the batteries hadn't been changed since 2020. Change out all batteries in float lights aboard this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 28 August 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 29 September 2022
Resolved
Found vessel using electronic chart plotter as it's primary means of navigation. Found electronic charts and software from 2015. Update charts and software to latest version.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 30 August 2021
Resolved
Vessel's primary means of navigation is the electronic charting system. Electronic charts have not been updated since 2015. Update electronic charts in operating area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 28 August 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2021
Resolved
vessel temporarily lost main propulsion system. Prove proper operation of the main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2021
Resolved 27 May 2021
Resolution: Company found fuel return line clogged and possible fuel vent blockage which caused vacuum in fuel tank which starved the MDE. Repaired and underway sea trials completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2020
Resolved
Maindeck Life Ring needs replaced. Horses chewed through the grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2020
Resolved
Electric outlet in the lazarette needs to be resecured to the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 1 October 2020
Resolved
Escape hatch from the engine room must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 2 November 2020
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 October 2020
Resolved
Old water inlet from engine room to sewage space needs to be plugged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 26 October 2020
Resolution: Corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 October 2020
Resolved
When Class 1 materials are being loaded, handled, or unloaded on a vessel, the vessel must exhibit the following signals:
(a) By day, flag “B” (Bravo) of the international code of signals; and
(b) By night, an all-round fixed red light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 23 August 2021
Resolution: Light & flag installed, installation & ops check approved/completed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 October 2020
Resolved
Lifefloats are being stowed in tiers of two without spacers. Found lifefloats stuck together. Replace spacers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 2 November 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2018
Resolved
Collision bulkhead must be watertight. Collision bulkhead is not watertight near the keel. Temporary repairs to be completed to consist of epoxy patch no later than 31 August 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 29 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 August 2018
Resolved
Further to item 1, permanent repairs to collision bulkhead shall be carried out prior to operating in 2019 and before 15 May 2019, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 2 November 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 August 2018
Resolved
Hatches exposed to the weather must be watertight. The engine room emergency escape hatch is not watertight. Hatch must be made watertight before 3 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2018
Resolved
All cable must be installed in such a manner to avoid chaffing. Chaffing gear is required on electric cable to refrigeration unit before 26 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 2 May 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2018
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cable without supports shall be corrected before 26 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 2 May 2019
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 August 2018
Resolved
A weathertight door must be provided for each opening located in a deck house. The door to the engine room is not weathertight. Door must be made weathertight before 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 August 2018
Resolved
After loading and prior to departure, master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Master is unable to determine if bilges are dry, as per stability letter. Must provide means to check bilges by 26 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 14 November 2018
Resolution: Provided means to check spaces containing steering machinery and sewage tanks.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 27 August 2018
Resolved
Seats used to determine the number of passengers permitted must be secured to the deck, bulkhead, or bulwark. Seating on upper deck is missing bolts in the deck and must be secured by 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: seats properly secured.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 August 2018
Resolved
Vessel must carry adequate and up to date light list. Light list onboard is not up to date. Light list must be updated before 3 September 2018 to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 17 January 2019
Resolution: updated.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 August 2018
Resolved
Bilge suction lines must have check valve or stop-check valve. Bilge suction lines are missing check valves; check valves must be installed by 26 September 2018, to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 17 January 2019
Resolution: corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 22 September 2017
Resolved
Several wastage of hull bottom plating and related interneal framing and bulkheads, mostly from interior arising from inadequate internal coatings and long-term exposure to standing water. See narrative for extensive details. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2018
Resolved 28 May 2018
Resolution: See narrative.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 May 2017
Resolved
Properly mark E/R emergency exit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Marked.
Lifesaving › Lifefloat › Float Free
Issued 19 May 2017
Resolved
Install spacers between floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 May 2017
Resolved
Replace inop light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Replaced battery.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2017
Resolved
Remove or bolt down all permanent seating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Bolted down all seating.
Navigation › Piloting/Steering › Marine Charts
Issued 19 May 2017
Resolved
Update.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 1 June 2017
Resolution: Updated.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 May 2017
Resolved
Replace cracked window pilothouse stbd side and cracked porthole main deck forward port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 15 June 2017
Resolution: Windows replaced.
Lifesaving › Lifefloat › Painter
Issued 26 April 2016
Resolved
Make individual attaching lines from life float to sea painter of sufficient length to launch individually prior to operating.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 26 April 2016
Resolution: Installed lines of appropriate length.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 April 2016
Resolved
Three child size life jackets are not serviceable. Limited to 130 passengers until replacement/repairs are on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 27 April 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 26 April 2016
Resolved
Replace hand operated petcock on primary fuel filter with mechanical type cocks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Electrical › Electric Generation Source (service) › Generator
Issued 26 April 2016
Resolved
Complete full load test on starboard generator prior to use.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 30 May 2016