MAURY USCG vessel records
← All vessels

SKYLARKER

SKYLARKER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 16 deficiencies and 1 casualty investigation in 2007.

Records from 2007 to 2026. Most recent: inspection, 23 June 2026.

Built
1995
Last inspected
23 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI5289
423246
Flag
UNITED STATES
Maury page id
psix-423246

Documentation record

Registered dimensions (L × B × D)60.0 ft × 19.0 ft × 7.0 ft
Registered tonnagegross 53 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Simplified, Gross Ton
42 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

23 June 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8356745
24 June 2025 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8165343
29 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8123074
14 May 2024 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7909924
10 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7684993
30 March 2023 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7659883
6 December 2022 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7605066
28 July 2022 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7518933
16 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7452396
22 March 2022 Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7414165
4 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7191626
22 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7163263
7 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6957762
23 May 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6691290
29 April 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6672869
8 May 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402478
22 March 2017 DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106572
22 March 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6109840
21 June 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5913967

Deficiency record · 16

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Fire detector in the engine room is not interconnected to the other fire detectors on board the vessel. Repair fire detector to the satisfaction of the attending Marine Inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Fire detector in the engine room was replaced. All fire detectors are interconnected and operated to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
Investigate ground, and clear it to the satisfaction of the Marine Insepctor. 46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: Recieved photo of ground detection showing 0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
Light indicating if the shore tie is connected to the vsl was not working. Repair light. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 16 May 2022
Resolution: Light was replaced and is working
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
Ground detection button was inoperable. Identify problem and make proper repairs to ground detection panel. 46 CFR 176.25-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 16 May 2022
Resolution: Ground detection system was tested and is working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
A breaker was missing from the distribution panel in the engine room. Install a blank. 46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: received photo of blank breaker in distribution panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2022 Resolved
An unauthorized fan was found in the engine room by the port main engine. Remove fan from the engine room. 46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: Fan removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 March 2022 Resolved
The gasket on the forward hatch was corroded and had dry rot. Replace gasket. 46 CFR 171.124(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 16 May 2022
Resolution: New gasket installed on hatch to fwd peak
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 March 2022 Resolved
Expired contents were found in the first-aid kit. Replace expired items in first aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 28 March 2022
Resolution: Recieved photo of new first aid contents
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 May 2021 Resolved
Vessel was missing 01 required fire bucket. Add 2.5 gallon bucket with lanyard and label bucket "fire bucket".
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: Bucket added prior to end of inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2021 Resolved
Galley receptacle did not have ground as shown with circuit tester. When cover was removed, receptacle was wasted. Replace in kind and provide ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 5 May 2021
Resolution: Receptacle was replaced and grounding conductor attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 March 2021 Resolved
Replace through hull under freezer in #2 space and guage pitting under freezer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 24 March 2021
Resolution: Transducer had been welded closed. Localized pits have been cleaned and coated with anti corrosion inhibitor.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2019 Resolved
Provide up to date charts fo the area the vessel operates. - 46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 29 May 2019
Resolution: Master ordered the required chart.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2019 Resolved
Provide non-expired eye wash for the first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 29 May 2019
Resolution: Master sent a photograph of the eyewash.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2019 Resolved
Replace the battery in the floating waterlight attached to the ring life buoy. - 46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 29 May 2019
Resolution: Master provided a photograph of the new waterlight battery.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 March 2017 Resolved
Placarding in vessel cabin shows 53 Adult life jackets, Vessel only has 49. Provide 04 Type I Life Jackets prior to carring 49+ passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 March 2017
Resolution: 04 Type one life jackets were labeled and stowed on board.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 22 March 2017 Resolved
02 life jackets require lights. Provide 02 lights for life jackets prior to carrying 49+ passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 March 2017
Resolution: 02 Life Jackets lights were provived before complete of inspection.

Casualty record · 1

15 September 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3086288
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEARCHER II (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.