Records from 1995 to 2005. Most recent: inspection, 20 April 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
20 April 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2339609
29 August 2003
Deficiency Check · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1890664
1 July 2003
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1831918
5 November 2001
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1412378
8 February 2000
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815630
25 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1441606
11 January 2000
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1045915
23 December 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1384321
24 June 1999
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 884057
27 October 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1429029
24 September 1998
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 799996
12 March 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1455561
9 January 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1123466
3 November 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 785186
17 June 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 776198
19 November 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 869571
27 October 1995
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 881089
30 May 1995
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1182542
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 April 2005
Resolved
Vessel not allowed to carry passengers until a Certificate of Inspection has been satisfactorily completed.
Due 21 June 2005
Resolved 30 November 2006
Operations/Management › Passenger Operations
Issued 29 August 2003
Resolved
Vessel is not to operate with passengers until all CG-835 items are cleared by the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: All CG-835 cleared.
Documentation › Certificates/Documents
Issued 1 July 2003
Resolved
Provide current Certificate of Documentation upon receipt. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: COD was provided, all sat.
Lifesaving › Lifejacket/PFD (General)
Issued 1 July 2003
Resolved
Provide lifejacket signs on storage box sides. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Lifejacket signs provided.
Lifesaving › Lifebuoys
Issued 1 July 2003
Resolved
Provide a buoyant line for ring lifebuoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Buoyant line provided, all sat.
Lifesaving › Lifebuoys
Issued 1 July 2003
Resolved
Provide retroreflective tape for ring buoy.
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Cleared, all sat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 July 2003
Resolved
Provide a tighter fit for e/r air intake vent cover on port side. LEGACY COMPONENT DESC: Piping (air intake)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Vent cover was refitted, all sat.
Fire Fighting › Miscellaneous Items
Issued 1 July 2003
Resolved
Provide a battery for smoke detector located in forward compartment.
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Operational tested the smoke detector, all sat.
Electrical › Electrical Distribution System (service)
Issued 1 July 2003
Resolved
Provide wire retainers for overhead wires in e/r. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Wire was secure, all sat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 July 2003
Resolved
Affix coolant reservoir container to bulkhead in e/r.
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: Coolant resevoir container secure.
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 July 2003
Resolved
Provide a first aid kit.
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 7 October 2003
Resolution: First aid kit provided.
Unknown
Issued 23 December 1999
Resolved
Replace deteriorated horn air reciever and test system for air tightness not later than 08JAN2000 to the satisfaction of the attending USCG marine inspector.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Documentation
Issued 3 November 1997
Resolved
Provide a valid copy of a FCC radio station license. Until this is provided vessel may not operate more than 1000' from shore._x001C_
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Unknown
Issued 3 November 1997
Resolved
Provide proof of payment of vessel user fee. Vessel currently owes for 96-97 and 97-98. Total amount due is $600.00.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Documentation
Issued 3 November 1997
Resolved
Provide a valid FCC radio safety equipment certificate. Until this requirement is cleared the vessel may not operate more than 1000' from shore._x001C_
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Documentation
Issued 3 November 1997
Resolved
Provide a copy of a valid radio operators license. Until this requirement is satisfied the vessel may not operate more than 1000' from shore.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Lifesaving
Issued 3 November 1997
Resolved
Provide a portable watertight container for the emergency distress flares in accordance with 46CFR185.614.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Unknown
Issued 3 November 1997
Resolved
Provide proof of crew enrollment in a certified drug testing program.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Lifesaving
Issued 3 November 1997
Resolved
Provide new batteries for the emergency flashlight.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Lifesaving
Issued 3 November 1997
Resolved
Conduct man overboard drill in the presence of a marine inspector.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Unknown
Issued 3 November 1997
Resolved
Provide proof of a passenger count being maintained in accordance with 46CFR185.504.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Unknown
Issued 3 November 1997
Resolved
Provide proof of crew training in accordance with 46CFR185.420/520/524.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Documentation
Issued 27 October 1995
Resolved
PROVIDE PROOF OF IMPLIMENTATION OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Construction/Loadline
Issued 30 May 1995
Resolved
Remove test coupon from vessel hull location to be determined by CG inspector and taken to test facility for burnout test. Vessel passengers capacity reduced to 12 until results of test are approved by [name withheld].
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Engineering
Issued 30 May 1995
Resolved
Conduct 5 PSI air test or 11 1/2 standpipe test of vessels fuel tank in present of CG Inspector.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995