MAURY USCG vessel records Sign in
← All vessels

ALLEGRO DOUBLE

ALLEGRO DOUBLE is a 1983 tank ship. The Coast Guard has recorded 29 inspections since 1995, most recently in February 2007, along with 23 deficiencies and 5 operational controls.

Records from 1995 to 2007. Most recent: operational control imposed, 5 February 2007.

Built
1983
Last inspected
5 February 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8138683 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
423292
Flag
RUSSIA
—
Maury page id
psix-423292

Inspections, by type

…with no type recorded23
Years with a record 8 calendar years (1995–2007)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it37916 - Convention (Subpart B), Gross Ton
37916 - Regulatory (Subpart C or D), Gross Ton
21237 - Convention (Subpart B), Net Ton
21237 - Regulatory (Subpart C or D), Net Ton
67980 - Dead Weight, Ton
84480 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

5 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2867432
11 July 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2709813
2 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2668272
30 May 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2664540
9 May 2006 PII Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2644935
9 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2645098
8 March 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2598798
27 January 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2574346
5 December 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2546654
7 November 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2529931
24 October 2005 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2520668
23 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2520420
11 February 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2004717
27 January 2004 Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1993565
31 October 1998 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388641
30 May 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 469267
22 March 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 414122
2 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412493
10 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411613
7 December 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 446139
3 September 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 407387
3 September 1997 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1121446
8 May 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 403114
20 May 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 391164
28 April 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 470894
23 January 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 387137
8 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69304
21 June 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 52036
1 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 378230

Deficiency record · 23

Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 October 2005 Resolved
Repair emergency lighting IWO Engine Control Room (Light fixture above electrical panel). To Satisfaction of vsls class society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 October 2005 Resolved
Repair broken support upper brackets IWO #2 steam turbine piping. To Satisfaction of vsls class society.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 October 2005 Resolved
Repair missing lagging IWO #2 steam turbine piping. To Satisfaction of vsls class society.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Electrical › Electric Generation Source (service) › Generator
Issued 24 October 2005 Resolved
Repair excessive leakage IWO generator fresh cooling pump shaft packing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 October 2005 Resolved
Repair broken handrails IWO engine room (02 spots). To Satisfaction of vsls class society.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Fire Fighting › Fire Patrol › Call Points
Issued 24 October 2005 Resolved
Repalce/repair inop cargo pumproom fixed smoke detector. To Satisfaction of vsls class society.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Accommodation/Occupational Safety › Ventilation › General
Issued 24 October 2005 Resolved
Obtain correct combustible gas indicator span gas, as required by manufacture. To Satisfaction of vsls class society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 24 October 2005 Resolved
Repair missing structural fire protection IWO cargo pump room ceiling. To Satisfaction of vsls class society.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Deck/Cargo › Cargo Heating › General
Issued 24 October 2005 Resolved
Repair broken/leaking soft patched cargo heating condesate piping on main deck.To Satisfaction of vsls class society.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 October 2005 Resolved
Remove combustables behind cargo/ballast control panel in cargo control room. To Satisfaction of vsls class society.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 October 2005 Resolved
Provide tech report concerning false reading indciators for vsl fixed ballast tank combustable gas indicatoring unit, (false readings 0.2 to 0.6 in various tanks at any given time). To Satisfaction of vsls class society or fax report of correction to USCG.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: recived class report
Lifesaving › Launching Appliances
Issued 27 January 2004 Resolved
Davit arms moved toward stowed position as the lifeboat was being lowered causing the lifeboat to slam into davit. Make permanent and proper repairs to the STBD lifeboat davit to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Davit
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2004
Lifesaving › Lifeboat
Issued 27 January 2004 Resolved
STBD Lifeboat sustained damage while lowering due to lifeboat davit problem. Make permanent and proper repairs to the STBD lifeboat to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2004
Lifesaving › Launching Appliances
Issued 27 January 2004 Resolved
Due to the failed operation of the STBD Lifeboat Davit, the vessel will also prove the Port Lifeboat Davit is fully functional by lowering the Port Life Boat. LEGACY COMPONENT DESC: Davit
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2004
Deck/Cargo
Issued 10 January 1998 Resolved
Explosion in a water slop tank, 8 center, lead to structural concerns and aloss of pump room structural/ventilation integrity.
Condition: Unknown
Due 2 February 1998
Resolved 2 April 1998
Construction/Loadline
Issued 3 September 1997 Resolved
MAKE PERMANENT REPAIRS TO FORWARD FOC'SLE DECK HATCH COVER HOLES(2)_x001C_ ILLC 66 ANNEX 1/18
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Construction/Loadline
Issued 3 September 1997 Resolved
MAKE PERMANENT REPAIRS TO NO. 2 BALLAST TANK ACCESS HATCH (MISSING DOG)_x001C_ ILLC 66 ANNEX 1/12
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Fire Fighting
Issued 3 September 1997 Resolved
PROVIDE DOCUMENTATION OF ANNUAL SERVICING OF ALL FIRE EXTINGUISHING SYSTEMSSOLAS 74 (AMENDED) REG II-2/7(e)
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Construction/Loadline
Issued 20 May 1996 Resolved
NUMBER THREE (3) BALLAST TANK NEEDS TO BE VENTILATED AND MADE READY FOR COAST GUARD INSPECTION IN NEXT U.S. PORT. NVI POLICY 6-91.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Documentation
Issued 20 May 1996 Resolved
LETTER FROM CLASSIFICATION SOCIETY THAT VESSEL COMPLYS WITH DOUBLE HULL STANDARDS IS MISSING. 33 CFR 157.10d.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Deck/Cargo
Issued 20 May 1996 Resolved
PROVIDE EVIDENCE FOR VAPOR CONTROL SYSTEM CERTIFICATION. 33 CFR 155.750 (d).
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Deck/Cargo
Issued 23 January 1996 Resolved
PROVE CARGO TANKS ARE INERTED TO LESS THAN 8% OXYGEN.
Condition: Unknown
Due 23 January 1996
Resolved 24 January 1996
Deck/Cargo
Issued 23 January 1996 Resolved
DEMONSTRATE OPERATION OF AT LEAST TWO PORTABLE O2 METERS._x001C_ _x001C_ _x001C_ SOLAS 74 II-2/62.M
Condition: Unknown
Due 23 January 1996
Resolved 24 January 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.