Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 20
19 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8376235
17 April 2026
Annual Inspection · Periodic Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8350650
23 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8192599
7 January 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8058896
19 April 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7901884
11 April 2023
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7663989
16 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7457471
5 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7445317
2 May 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439869
19 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7179666
5 May 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6953037
10 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6871977
30 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6673603
18 May 2018
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6417695
18 May 2018
Type not recorded
No type recorded · Station Marblehead · USCG Great Lakes District (CGD-GL) · Activity 6418544
18 May 2018
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6441049
9 April 2018
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6388064
20 April 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6129155
15 September 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6001401
17 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5879598
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2026
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Life buoy did not have retro-reflective tape as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 April 2026
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels EPIRB has an expired battery. Vessel is restricted to three miles from shore until EPIRB battery is replaced. Vessel is to ensure if EPIRB is replaced that it is properly registered with NOAA. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 April 2026
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions posted. 46 CFR 185.510(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026
Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel could not provide logs to show monthly tests where being completed. 46 CFR 185.728(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026
Resolved
Fire fighting and Abandon ship/man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. Vessel could not provide logs to show drills where being completed. 46 CFR 185.524(d)
46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 April 2026
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel could not provide logs to show monthly inspections of fire extinguishers where being completed. 46 CFR 176.810(b)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 19 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 April 2024
Resolved
Retro-Reflective Tape worn and in need of replacement on Life float. Replace Retro tape in kind meeting standard (NVIC 1-83).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 27 August 2024
Resolution: Documentation provided showing replaced retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
A VESSEL OF MORE THAN 26-FEET IN LENGTH MUST CARRY A MINIMUM OF ONE LIFE BUOY OF NOT LESS THAN 24-INCHES, APPROVED BY 160.050 OF THIS SUBCHAPTER. THE VESSELS RING BUOY HAD DETERIORATED AND DETATCHED GRAB LINES.
46CFR180.70(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2023
Resolution: Inspected ring buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 28 April 2023
Resolution: Verified Marine radio operator permit
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2023
Resolved
A VESSEL OF AT LEAST 26-FEET IN LENGTH MUST HAVE AN AUDIBLE/VISUAL BILGE HIGH LEVEL ALARM PROVIDED AT THE OPERATING STATION. THE BILGE HIGH LEVEL ALARM WAS INOPERABLE.
46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2023
Resolution: BILGE HIGH LEVEL ALARM UNIT AND FLOAT SWITCH REPLACED AND SATISFACTORILY TESTED.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 April 2023
Resolved
THE OWNER OR MANAGING OPERATOR SHALL MAKE SURE THAT MAINTENANCE IS CARRIED OUT IN ACCORDANCE WITHTHE MANUFACTURER'S INSTRUCTIONS FOR ALL SURVIVAL CRAFT. THE VESSEL'S LIFE FLOAT WAS IN A CONDITION REQUIRING REPAIR OF REPLACEMENT DUE TO DAMAGE INFLICTED BY NATURAL ELEMENTS AND ANIMALS.
46CFR185.702(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 April 2023
Resolution: Verified life float
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 April 2023
Resolved
EACH VESSEL SHALL CARRY ON BOARD A FIRST AID KIT APPROVED IN ACCORDANCE WITH 160.041 OF THIS PART. THE VESSEL HAD A FIRST AID KIT THAT DID NOT MEET THE REQUIREMENTS OF 160.041
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2023
Resolution: Verified first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 April 2023
Resolved
VESSELS ON A GREAT LAKES ROUTE SHALL CARRY SIX HAND RED AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL HAD SIX ORANGE AND THREE RED DISTRESS SIGNALS.
46CFR180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 11 April 2023
Resolution: verified distress signals
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 April 2023
Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLES, AND COAST PILOT WERE NOT UPDATED. *UPDATED LIGHT LIST ADDED TO THE VESSEL PRIOR TO INSPECTION COMPLETION.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2023
Resolution: Verfifed Pubs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2023
Resolved
WIRING JOINTS AND SPLICES SHALL BE MECHANICALLY SECURE AND MADE IN A JUNCTION BOX. MULTIPLE CONNECTIONS/SPLICES WERE MADE, I OUTSIDE OF JUNCTION BOXES AND EXPOSED TO WEATHER/WATER CONDITIONS.
46CFR183.05-50(b)(1)
"OLD T"46CFR183.05-50(b)(1)
"OLD T"
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 April 2023
Resolution: Verified electrical.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 5 May 2022
Resolution: Received photograph of newly purchased/installed HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 May 2022
Resolved
A VESSEL MUST CARRY A FLOATING WATERLIGHT. THE FLOATING WATERLIGHTS ON THE VESSEL WERE NOT OPERATING AS APPROVED, DUE TO THE BATTERIES NEARING THE END OF THEIR SERVICE LIFE. VESSEL RESTRICTED TO DAYTIME OPERATIONS.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2022
Resolution: WATERLIGHT VERIFIED TO BE OPERATIONAL.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 May 2022
Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLES, AND COAST PILOT WERE NOT UPDATED.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: UPDATED PUBS/CHARTS WERE ON BOARD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2019
Resolved
Propeller Shaft bearing (cutlass) worn. Replace prior to the vessel going back into the water from Dry Dock.
Action required: 705 - Other - as specified
Due 6 March 2020
Resolved 20 March 2020
Resolution: Vessel owner replaced shaft bearing
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 December 2019
Resolved
Frame after the engine shaft seal is cracked and has deuteration around the shaft tube connected to the frame. repair / replace
Action required: 705 - Other - as specified
Due 6 March 2020
Resolved 20 March 2020
Resolution: Vessel owner replaced the stell arounf the shaft tube. all repairs inspected; all sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 April 2019
Resolved
Retro Reflective tape needs to be replaced with new tapeas designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2019
Resolved 22 May 2019
Resolution: Vessel owner replaced worn retro reflective tape with new.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 April 2019
Resolved
Life Float floating waterlight is non operational and has water inside the light casing. repair / replace
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 2 May 2019
Resolution: Vessel owner replaced floating light
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 April 2019
Resolved
Vessels charts and publications are not up to date. Vessel required to update charts and publications with the most up to date information for the area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2019
Resolved 22 May 2019
Resolution: vessel owner ordered new charts and sent picture of the reciept and the chart
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 18 May 2018
Resolved
MDE mechanical failure no-start
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2018
Resolved 9 June 2018
Resolution: Vessel's main engine was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 April 2018
Resolved
05 adult PFD's were found unserviceable. Crew replaced with new spares on the spot.
Action required: 10 - Deficiency Rectified
Due 18 April 2018
Resolved 18 April 2018
Resolution: New PFD's were stenciled and placed onboard vessel as required.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 April 2018
Resolved
EPIRB HRU was found to be expired.
Action required: 10 - Deficiency Rectified
Due 18 April 2018
Resolved 18 April 2018
Resolution: New HRU was installed and marked as required.
Communications › Radio Communications › EPIRB
Issued 17 May 2016
Resolved
EPIRB hydrostatic release unit (HRU) does not have it's expiration date marked. Mark expiration 2 years from date of installation IAW 46 CFR 185.740.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 15 September 2016
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 17 May 2016
Resolved
The hose supplying cooling water to the engine shows signs of cracking and deterioration at fwd end of engine. Replace hose IAW 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 15 September 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 May 2016
Resolved
Current Certificate of Documentation (COD) was not available on vessel. Provide current COD for vessel with all applicable endorsements IAW 46 CFR 67.7.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 15 September 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 May 2016
Resolved
The cowling for the machinery space opening (adjacent to the operating station) is loose and deteriorated on the stbd side. Repair cowling as original IAW 46 CFR 177.410.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 15 September 2016