Records from 1985 to 1999. Most recent: inspection, 5 August 1999.
Inspection history · 19
5 August 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 32509
17 May 1998
Uninspected Other
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 804144
29 July 1996
Uninspected Other
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1089617
27 April 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1268056
14 May 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 904644
18 April 1991
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 904827
25 February 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1230868
3 January 1991
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 927131
8 May 1990
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1236561
11 September 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1031273
20 July 1989
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1038409
23 May 1989
COI Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1198061
1 June 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1339662
1 May 1987
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1023229
12 December 1986
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1004515
1 July 1986
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1301922
20 June 1986
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 995448
14 June 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 983153
28 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1290897
Lifesaving
Issued 8 May 1990
Resolved
PROVIDE 13 ADDITIONAL LIFE JACKETS
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Documentation
Issued 8 May 1990
Resolved
SUBMIT A LTR TO THE CG STATING THAT YOUR DRUG TESTING PROGRAM HAS BEEN STARTED BY 21DEC90
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Documentation
Issued 8 May 1990
Resolved
PROVIDE FCC STATION LICENSE ON BOARD VSL
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Documentation
Issued 8 May 1990
Resolved
PROVIDE FCC OPERATOR'S LICENSE ON BOARD VESSEL ACTUAL COMPLIANCE DATE: 8JUN90
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Electrical
Issued 8 May 1990
Resolved
PROVIDE ER SWITCH FOR BATTERY
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 23 May 1989
Resolved
REPLACE WASTED FASTENERS IN STERN
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Construction/Loadline
Issued 23 May 1989
Resolved
REPLACE WASTED THROUGH BOLT IN KEEL JUST FORWARD OF RUDDER POST
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Construction/Loadline
Issued 23 May 1989
Resolved
REPAIR AND SISTER BILGE STRINGER ON PORT SIDE OF ENGINE (APPROX 4')
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Construction/Loadline
Issued 23 May 1989
Resolved
CONDUCT UNDERWAY EXAM ACTUAL COMPLIANCE DATE FOR ABOVE REQUIREMENTS: 26JUL89
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Unknown
Issued 20 June 1986
Resolved
PROVIDE DOUBLE HOSE CLAMPS IN WAY OF ALL MAIN PROPULSION MACHINERY RAW WATER INTAKE, EXHAUST AND COOLING SYSTEMS HOSE COUPLINGS.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Unknown
Issued 20 June 1986
Resolved
PROVIDE PERMANENT LABELING FOR EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Construction/Loadline
Issued 28 May 1985
Resolved
DURING CREDIT DRYDOCK EXAM ON 24-28MAY85, ONE BAD BOARD ON PORT SIDE FWD HALFWAY UP THE HULL WAS FOUND AND REPLACED SATISFACTORILY. REPORT MADE IN ACCORDANCE WITH ALDIST 091/85-COMDTNOTE 19711.
Condition: Unknown
Due 28 May 1985
Resolved 28 May 1985