MAURY USCG vessel records Sign in
← All vessels

MAIDEN VOYAGE

MAIDEN VOYAGE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1995, most recently in May 2012, along with 23 deficiencies.

Records from 1995 to 2012. Most recent: inspection, 24 May 2012.

Built
1995
Last inspected
24 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCR4917
423556
Flag
UNITED STATES
—
Maury page id
psix-423556

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (1995–2012)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it8 - Simplified, Net Ton
8 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

24 May 2012 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4315007
29 April 2009 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 3467912
9 December 2008 Administrative Inspection · Simplified Stability Test · Hull Examination
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3376737
20 October 2008 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 3348121
29 July 2008 Re-Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3290992
11 June 2007 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2972822
22 May 2006 Deficiency Check · COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2652287
4 April 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2321628
19 August 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2170769
29 March 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2033494
8 March 2004 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2020555
4 April 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1768310
3 March 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1754950
3 April 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1606608
20 August 2001 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1070739
13 April 2001 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417245
9 April 2001 COI Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445793
2 August 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1053407
23 March 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1395389
8 November 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 801483
3 May 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1365196
12 November 1998 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1467086
29 May 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 792192
11 May 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1460193
5 May 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1096093
17 March 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1458389
9 August 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1086565
26 July 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1087274
13 June 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 877267
28 December 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875898
10 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1182815
1 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1189277
26 April 1995 Hull Examination · Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1171154

Deficiency record · 23

Construction/Loadline › Hull › Hull Plating
Issued 29 April 2009 Resolved
Numerous cracked welds noted in narrative.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 17 May 2010
Resolution: All cracks were welded
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 April 2009 Resolved
Markings need renewed on life rings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 17 May 2010
Resolution: Markings were renewed on life Rings
Documentation › Certificates/Documents › Stability Letter
Issued 22 May 2006 Resolved
Post stability letter per 46 CFR 176.306
Due 22 June 2006
Resolved 27 May 2006
Resolution: Stability Letter posted
Navigation › Piloting/Steering › Marine Charts
Issued 22 May 2006 Resolved
Provide river charts on board per 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Updated river charts provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 May 2006 Resolved
Replace one adult lifejacket
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Lifejacket replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2006 Resolved
Provide 60 foot lifeline for ring bouy per 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Lifeline provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2006 Resolved
Demonstrate proper operation of waterlight per 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Conducted satisfactory demonstration of waterlight.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2006 Resolved
Connect waterlight to the ring bouy with a 3-6 foot line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Waterlight connected with the proper line.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 May 2006 Resolved
Provide 2 flashlights near the operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 27 May 2006
Resolution: Flashlights provided.
Operations/Management › Passenger Operations
Issued 10 March 2003 Resolved
Provide MSO Hampton Roads with an update to your approved orientation booklet showing emergency cellular numbers for use by passengers. This requirement must be completed prior to the carriage of passengers with a single operator.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 7 April 2003
Lifesaving
Issued 9 April 2001 Resolved
ASPIRIN IN FIRST AID KIT EXPIRED.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 9 April 2001 Resolved
FIRST AID KIT NOT PROPERLY MOUNTED.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 9 April 2001 Resolved
LIFEJACKETS AND LIFERINGS NOT PROPERLY STENCILED WITH VESSEL NAME.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 3 May 1999 Resolved
REPLACE RETRO TAPE AS NECESSARY ON ALL LIFEJACKETS AS REQUIRED BY 46 CFR 185.604 TO SATISIFY THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Navigation
Issued 3 May 1999 Resolved
WIRE COMPASS LIGHT FOR PROPER OPERATION.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Lifesaving
Issued 11 May 1998 Resolved
PROVIDE C. G. APPROVED FIRST AID KIT.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Construction/Loadline
Issued 26 July 1996 Resolved
GOUGE AND REWELD FRACTURE IN THE WELD, STARBOARD, AFT. TRANSOM, IN WAY OF THE ENGINE MOUNT.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Documentation
Issued 13 June 1996 Resolved
OBTAIN FCC OPERATOR'S PERMITS FOR EACH OF THE MASTERS.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 13 June 1996 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR THE LIFERING.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Documentation
Issued 13 June 1996 Resolved
OBTAIN FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Electrical
Issued 13 June 1996 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Unknown
Issued 13 June 1996 Resolved
POST VESSEL NAME AND HOMEPORT ON STERN AND NAME ON BOTH BOWS.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Engineering
Issued 10 November 1995 Resolved
Replace 12 gallon plastic fuel tanks with approved 6 gallon tanks per discussion with CG inspector. Plastic tanks greater that 6 gallons prohibited by CID policy letter dated 02AOR93.
Condition: Unknown
Due 10 November 1995
Resolved 10 November 1995

Ownership record