BABY DOLL VIII

BABY DOLL VIII is a 1944 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 1985, most recently in November 1991, along with 34 deficiencies.

Records from 1985 to 1991. Most recent: inspection, 5 November 1991.

Built
1944
Last inspected
5 November 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WR9005
Flag
UNITED STATES
—
Maury page id
psix-42357

Inspections, by type

…with no type recorded7
Years with a record 5 calendar years (1985–1991)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
93 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

5 November 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 939450
26 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1347512
24 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1039368
20 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1345884
20 August 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1346160
12 August 1988 Excursion Permit
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1039776
27 April 1988 COI Inspection · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1042097
12 July 1987 Excursion Permit
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1028896
29 June 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1317405
6 April 1987 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1021018
31 October 1986 Credit Drydock
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1008532
28 April 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 993588
14 January 1986 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1300859
25 April 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1286537

Deficiency record · 34

Construction/Loadline
Issued 20 August 1988 Resolved
DRYDOCK VESSEL FOR HULL REPAIRS NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 1 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
MAKE PERMANENT REPAIR TO LEAK IN WAY OF LEAKING SCREW HOLE, STARBOARD SIDE OF KEEL, UNDER ICE CHEST.
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 20 August 1988 Resolved
REPLACE 1.5" FIRE HOSE AT FORWARD FIRE STATION NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 August 1988 Resolved
DRYSTORES: LOCATE AND REPAIR FUEL LEAK.
Condition: Unknown
Due 16 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 20 August 1988 Resolved
DRYSTORES: REPAIR LEAK FROM SHOWER VALVE.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 20 August 1988 Resolved
REMOVE UNSAFE ELECTRICAL LIGHTS IN FUEL COMPARTMENT.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 August 1988 Resolved
IDENTIFY AND REPAIR FUEL LEAK IN FUEL COMPARTMENT.
Condition: Unknown
Due 16 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 August 1988 Resolved
REPAIR LEAKS IN WAY OF BOTH STERN TUBES IN ENGINE ROOM.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 20 August 1988 Resolved
PROVE OPERATION OF FIXED BILGE SYSTEM.
Condition: Unknown
Due 16 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
PROVIDE PROPER VENTILATION FOR MACHINERY SPACE, WITH AT LEAST ONE DUCT EXTENDING TO BOTTOM OF SPACE.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
FOREPEAK: REPAIR LADDER ADRIFT(TO ACCESS SPACE).
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
PREPARE FOREPEAK FOR INTERNAL EXAMINATION (REMOVE ROPE, FLOORBOARDS, AND MISCELLANEOUS ITEMS).
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
LOCATE LEAK IN BOTTOM, PORT SIDE, AT BILGE CHINE, 5TH FRAME FROM LEFT AFT, IN SECOND COMPARTMENT AND MAKE WATERTIGHT REPAIRS.
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
REPAIR OR RENEW WASTED REACH ROD ON BILGE VALVE IN FOREPEAK AND PROVE OPERATION.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 August 1988 Resolved
INSTALL PROPER METAL STRAINERS ON BILGE SYSTEM NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
MAKE THE COLLISION BULKHEAD WATERTIGHT IN WAY OF PORT SKIN APROXIMATELY 6 FEET FROM KEEL NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
INVESTIGATE POSSIBLE LEAKS AT FRAMES 4 AND 6, FROM AFT, ON EITHER SIDE OF LEAK IN ITEM 3(SECOND COMPARTMENT).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
MAKE PERMANENT REPAIRS TO BOWED AND LOOSENED FRAME, #10 FROM AFT, PORT SIDE(SECOND COMPARTMENT)
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
FRAMES 5 - 9, FROM FORWARD, STARBOARD SIDE, IMPROPERLY REPAIRED, ALL CRACKED THROUGH, MIDWAY BETWEEN KEEL AND CHINE(SECOND COMPARTMENT).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
FRAME 9 ROTTEN IN WAY OF KEEL(SECOND COMPARTMENT).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
HEAVY LEAK, FRAME 6, FROM FORWARD, STARBOARD SIDE, AT CHINE TIMBER. LOCATE LEAK AND MAKE WATEERTIGHT REPAIR(SECOND COMPARTMENT).
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
REPAIRS REQUIRED ON 3" X 8" LONGITUDINAL, WITH DEEP DRY ROT, IN WAY FORWARDBULKHEAD, PORT SIDE OF KEEL(SECOND COMPARTMENT).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
DRY STORES: REPAIR DRY ROT ATOP FORWARD FLOOR UNDER FORWARD BULKHEAD IN WAY OF KEEL.
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
LOCATE AND REPAIR LEAK, STARBOARD SIDE, FRAME 3 FROM AFT, IN WAY OF CHINE TIMBER(FUEL COMPARTMENT).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
PREPARE BUCKLED BULKHEAD, FORWARD, FOR EXAMINATION, BY REMOVING DELAMINATED PLYWOOD, IMMEDIATELY ABOVE FLOOR(FUEL COMPARTMENT).
Condition: Unknown
Due 16 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
REPAIR 8" X 8" HOLE IN FORWARD BULKHEAD, STARBOARD, BETWEEN KEEL AND FIRST LONGITUDINAL(ENGINE ROOM).
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
PREPARE ENGINE ROOM FOR BOTTOM EXAMINATION.
Condition: Unknown
Due 7 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
LOCATE AND REPAIR LEAK, STARBOARD SIDE OF BOTTOM BETWEEN KEEL AND FIRST LONGITUDINAL, BETWEEN FRAMES 5 AND 6 FROM AFT, IN WAY OF 9" X 9" PATCH REPAIR(AFTER STEERING).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 August 1988 Resolved
LOCATE AND REPAIR TWO (2) LEAKS BOTTOM OF STARBOARD SIDE AT 2ND ND 3RD LONGITUDINALS, FRAMES AND 4 AND 5 FROM AFT, UNDER 2" X 4" BILGE CHINE (AFTER STEERING).
Condition: Unknown
Due 30 April 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 April 1988 Resolved
REPAIR BROKEN AND MISSING (1 EACH) UNDER DECK ATTACHMENTS FOR UNDER DECK LONGS IN #2 COMPARTMENT AND REPLACE 18" OF ROTTED DECK PLANKING. "
Condition: Unknown
Due 30 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 April 1988 Resolved
SAND UNDER DECK BEAMS IN ENGINE ROOM IN AREA OF FIRRING AND TREAT WITH WOODPRESEVATIVE SOLUTION.
Condition: Unknown
Due 30 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 April 1988 Resolved
REPAIR INOPERATIVE REACH ROD AT COLLISION BULKHEAD.
Condition: Unknown
Due 30 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 April 1987 Resolved
PROVIDE ADDITIONAL LIFE JACKETS TO ACCOMODATE 105 PERSONS ON BOARD. UNTIL LIFE JACKETS ARE INSPECTED AND STAMPED, VESSEL IS LIMITED TO 99 ADULTS ON BOARD. COMPLETE TO THE SATISFACTION OF THE COGNIZANT [name withheld] 6 MAY 1987.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Engineering
Issued 28 April 1986 Resolved
MOUNT AIR COMPRESSER STORAGE TANK AND OPEN FOR INTERNAL INSPECTION.
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.