Records from 2016 to 2025. Most recent: inspection, 24 October 2025.
Inspection history · 23
24 October 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8258221
24 February 2025
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8083589
22 October 2024
In-Service Inspection · Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8021138
5 August 2024
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7974723
28 March 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7883639
7 March 2024
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7873973
4 March 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7873963
9 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7676359
6 February 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7627241
25 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7396813
7 February 2022
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7389280
6 May 2021
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7191245
31 March 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7166364
4 March 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7142646
8 January 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7119579
4 March 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6918790
23 April 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6661328
31 January 2019
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6616398
30 August 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6531711
25 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6388224
21 March 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6102213
8 February 2017
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6082631
19 February 2016
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5817931
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2024
Resolved
Individual power pumps used for separate spaces are to b
e controlled from a central control point and must have
a light or other visual means at the control point to
indicate operation. Bow electrical bilge pump was not functioning. Troubleshoot and repair bow electrical bilg
pump and provide test results to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2024
Resolved 8 April 2024
Resolution: Overboard check valve was blocked. O/O replaced electrical bilge pump and cleaned check valve. Test SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 March 2024
Resolved
To qualify for a medical certificate, a mariner must provide evidence of meeting the medical and physical standards in this section on a CG–719–K or CG–719–K/E, as appropriate. The Coast Guard retains final authority for determining whether a mariner is medically and physically qualified. Columns 2 through 5 of Table 1 to paragraph (a) of this section provide the specific exam, test, or demonstrations required to obtain the corresponding credential listed in column 1. Further clarifications of the requirements contained in the table are found throughout this subpart. Vessel Master medical certificate expired in 2020. Provide a valid med
-ical certificate to attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2024
Resolved 5 August 2024
Resolution: Vessel captain provided valid medical certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 March 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel's burn preperations and analgesic medications were expired. Vessel replaced on site. Deficiency code issued 10c.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 30 March 2024
Resolution: Expired first aid burn preperations and analgesic medications replaced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 May 2023
Resolved
Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. The bilge level alarm in the lazarette was not functioning. Repair and demonstrate functioning bilge level alarm.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2023
Resolution: Vessel found loose wire behind alarm panel and repaired it.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. Vessel did not have current Coast Pilot or Light List on board. Provide current publications.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 22 May 2023
Resolution: Vessel provided new electronic publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) . Letters and numbers must be at least 2 inches high. Symbols must be at least 4 inches square. Markings were missing from life jacket storage locations. Provide proper markings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 13 June 2023
Resolution: Vessel marked life jacket locations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. The block connecting the vertical and horizontal frames on the sixth frame from the forward end of the lazarette compartment was found split in way of both inboard fastenening through bolts. Provide repair proposal to attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 19 June 2023
Resolution: Vessel provided proposal to monitor frame and engage shipwright during next year's haul out period.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2023
Resolved
The Rules concerning shapes shall be complied with by day. Vessel was not provided with day shapes. Provide day shapes appropriate to vessel operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 13 June 2023
Resolution: Vessel provided day shapes.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2022
Resolved
A grease extraction hood required by 46 CFR 181.400 must meet UL 710 (incorporated by reference, see 46 CFR 175.600) or other standard specified by the Commandant. (b) A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A (both incorporated by reference, see 46 CFR 175.600), or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Provide plans for and install grease extration hood meeting UL 710 and associated NFPA 17 or 17A compliant fixed fire system prior to 04MAR2023. While operating prior to completion of installation, comply with G-MSE-4 Policy Letter PFM 1-99.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 March 2023
Resolved 28 February 2023
Resolution: Amended COI to reflect reduced passenger count.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2021
Resolved
Bilge high level alarm audible signal not operable. Demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: Vessel replaced audible alarm the same day.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 March 2021
Resolved
Distribution panel in engine room missing blank. Provide blank.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 16 March 2021
Resolution: Vessel installed a plastic blank.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021
Resolved
Re-stencil lifejacket locations in galley.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 16 March 2021
Resolution: Vessel re-stenciled lifejacket storage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2021
Resolved
Forepeak bilge valve not of the screw down type. Provide proper valve type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 6 May 2021
Resolution: Vessel isntalled screw down type valve.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 March 2021
Resolved
Drills, EPIRB tests and fire extinguisher checks not logged. Provide proper logs.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 16 March 2021
Resolution: Vessel logged drills that were conducted during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2020
Resolved
Remove power strip and perment extension cord from pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2020
Resolution: Vessel removed power strip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2020
Resolved
Replace ring buoy water light line with poly line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2020
Resolution: Vessle replaced ring buoy and line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2020
Resolved
Remove combustible rubbish containers from accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2020
Resolution: Vessel provided metal rubbish cans.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 March 2020
Resolved
Log abandon ship, fire extinguisher checks and epirb checks.
Action required: 10 - Deficiency Rectified
Resolved 4 March 2020
Resolution: Vessel conducted and logged drills during inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 April 2019
Resolved
Provide logs of fire drills, man overboard drills and EPIRB testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 17 May 2019
Resolution: Vessel provided logs showing completion of drills and tests.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 April 2019
Resolved
Provide VHF DSC radio with current MMSI programmed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 17 May 2019
Resolution: Vessel provided radio programmed with current MMSI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 April 2019
Resolved
Provide current navigational publications to include light list, coast pilot, tides and currents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 17 May 2019
Resolution: Vessel provided navigational publications.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 April 2019
Resolved
Proivide complete and current first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 17 May 2019
Resolution: Vessel provided first aid kit.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2018
Resolved
Update first aid kit.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 April 2018
Resolution: First aid kit updated.
Lifesaving › Lifebuoys › Serviceable
Issued 25 April 2018
Resolved
Renew retro tape on ling ring.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 April 2018
Resolution: Retro tape renewed.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 25 April 2018
Resolved
Place emergency broadcast placard on bridge.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 April 2018
Resolution: Placard installed.
Documentation › Logs/Records › Logbook (official)
Issued 25 April 2018
Resolved
Update drill log book.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 April 2018
Resolution: Drill book updated.
Lifesaving › Hand Flares › Quantity
Issued 21 March 2017
Resolved
Provide (02) red and (04) orange distress signals.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 March 2017
Resolved
Provide means of locking overboard discharge valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Construction/Loadline › Hull › Keel
Issued 8 February 2017
Resolved
Replace worm shoe on skeg.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 13 February 2017
Construction/Loadline › Hull › Side Shell
Issued 8 February 2017
Resolved
Scrape & treat decayed planking forward of fuel tank, stbd side of E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 24 February 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 February 2017
Resolved
Replace securing arms on forepeak hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 24 February 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 February 2016
Resolved
Prior to operating with passengers, prove proper operation of port fuel emergency shut-off.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2016
Resolved 29 February 2016
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 25 February 2016
Resolved
Install ladder to provide safe access to pilot house roof
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 30 March 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 February 2016
Resolved
Replace wire rope clip on stbd fuel shut-off pull cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 30 March 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 February 2016
Resolved
Provide pre-employment test result for deckhand.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 4 March 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 February 2016
Resolved
Raise anchor light above IBA & radome.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 30 March 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 February 2016
Resolved
Provide f/f servicing report for CO2 system (bottle weight, switch test).
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 29 February 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 February 2016
Resolved
Complete an inspection for COI renewal. Vessel may not operate with passengers until satisfactory completion of a COI renewal inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2016
Resolved 29 February 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 February 2016
Resolved
Provide current chem testing program crew list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 4 March 2016