← All vessels
STAMATINA P
STAMATINA P is a 1995 freight ship. The Coast Guard has recorded 14 inspections since 1995, most recently in August 2004, along with 14 deficiencies and 2 operational controls.
Records from 1995 to 2004. Most recent: inspection, 19 August 2004.
- Built
- 1995
- Last inspected
- 19 August 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9037018 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HQG4
423589
Flag
MALTA
—
Maury page id
psix-423589
Inspections, by type
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it6006 - Regulatory (Subpart C or D), Net Ton
12220 - Regulatory (Subpart C or D), Gross Ton
12220 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
19 August 2004
PII Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2170613
16 August 2004
PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2168952
10 July 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2127809
16 January 2002
Type not recorded
No type recorded · GROUP PHILADELPHIA · USCG East District (CGD-E) · Activity 1478994
16 January 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1479644
3 September 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 281784
29 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281740
25 March 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 426845
12 February 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412737
31 May 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 391632
21 February 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 387497
1 June 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 444478
23 May 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 378496
12 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 378374
Deficiency record · 14
Navigation
Issued 16 January 2002
Resolved
COAST PILOT NOT CURRENTLY CORRECTED. LEGACY COMPONENT DESC: PUBLICATION
Operations/Management › Drills/Instruction
Issued 16 January 2002
Resolved
UNSATISFACTORY FIRE DRILL. DRILL WAS STOPPED DUE TO TEAMS DRESSING OUT BEFORE ALARM WAS SOUNDED, TEAMS DID NOT KNOW HOW TO DRESS OUT IN FIRE SUITS PROPERLY, FIRE ALARM WAS NOT WORKING SATISFACTORY. LEGACY COMPONENT DESC: Fire
Deck/Cargo › Holds/Tanks
Issued 16 January 2002
Resolved
HINGES FOR #3P-AFT CARGO HATCH COVER SHEARED, CAUSED BY OVER STRESSING DUE TO LACK OF LUBE OIL PRESSURE W/IN THE OPERATING SYSTEM. VSL TO KEEP CARGO HATCH COVER(S) SECURED DURING TRANSIT UNTIL PERMANENT REPAIRS MADE. VSL TO PROVIDE CLASS REPORT FOR PERMANENT REPAIRS TO CLEAR THIS REQUIREMENT. LEGACY COMPONENT DESC: Hatch Cover
Construction/Loadline
Issued 3 September 2000
Resolved
PRIOR TO NEXT U.S. PORT REMOVE EXCESS OIL IN BILGE.
Navigation
Issued 29 August 2000
Resolved
EXCESSIVE LEAKAGE FROM STARBOARD STEERING GEAR RAM SEAL.(SOLAS 74 A, REG II-1/29)
Electrical
Issued 29 August 2000
Resolved
NO. 3 GENERATOR COOLING WATER TANK HOLED & LEAKING. (SOLAS 74 A II-1/41)
Electrical
Issued 29 August 2000
Resolved
NO. 3 GENERATOR FUEL BOOSTER PUMP HAS EXCESSIVE LEAKAGE.(SOLAS 74 A, REG II-2/2).
Unknown
Issued 29 August 2000
Resolved
SLUDGE TANK DRAIN LINE HAS TEMPORARY PATCH. (33CFR156.120).
Navigation
Issued 29 August 2000
Resolved
NO AUDIBLE ALARM ON BRIDGE FOR LOSS OF POWER FOR STEERING GEAR._x001C_ (SOLAS 74 A, REG II-1/29.8.4)
Construction/Loadline
Issued 29 August 2000
Resolved
EXCESSIVE OIL IN BILGE IWO OILY WATER SEPARATOR. (SOLAS 74 A/II-2/2)
Fire Fighting
Issued 31 May 1996
Resolved
Provide 01 nozzle on main deck forward.
Unknown
Issued 31 May 1996
Resolved
Maintain closed valve on MSD (overboard discharge) while in U.S. waters.
Documentation
Issued 31 May 1996
Resolved
Provide extension on Radio Certificate.
Navigation
Issued 12 May 1995
Resolved
MANEUVERING INFORMATION FOR LOADED CONDITION MISSING. (33 CFR 164.35(g))