MAURY USCG vessel records Sign in
← All vessels

ALDOR

ALDOR is a 1947 commercial fishing vessel. The Coast Guard has recorded 40 inspections since 1985, most recently in September 2001, along with 74 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 17 September 2001.

Built
1947
Last inspected
17 September 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WB8248
Flag
UNITED STATES
—
Maury page id
psix-42361

Inspections, by type

…with no type recorded4
Years with a record 17 calendar years (1985–2001)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

17 September 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1073568
29 May 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1070576
19 April 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1061991
21 September 2000 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1423452
16 September 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 166558
26 June 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373188
9 March 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1381841
29 June 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1097150
6 May 1999 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 796357
12 January 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 789493
1 June 1998 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1128590
30 March 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 787525
10 March 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 786057
10 March 1997 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1431752
13 June 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441081
18 April 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1080380
30 January 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 882307
1 March 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 834738
26 April 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 863361
26 April 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 885741
20 April 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1180894
22 June 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1377015
22 April 1993 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436760
22 April 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1256116
29 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 929889
9 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 926244
23 April 1991 COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 903929
26 October 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1231349
25 September 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 904549
23 August 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 905580
22 May 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240262
11 August 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1036065
27 July 1989 Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1200501
20 June 1989 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1352806
2 August 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1200396
14 July 1988 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 898326
22 October 1987 Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1315780
5 September 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1015503
13 May 1986 Credit Drydock
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 987450
22 July 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1287070

Deficiency record · 74

Lifesaving
Issued 9 March 2000 Resolved
RENEW GRAB LINES AND RE-STENCIL BUOYANT APPARATUS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Navigation
Issued 9 March 2000 Resolved
PROVIDE CURRENT CHARTS AND TIDE TABLES.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Navigation
Issued 9 March 2000 Resolved
RENEW LIGHT ON MAGNETIC COMPASS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
CONDUCT U/W INSPECTION OF GME, STEERING AND HULL. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
CONDUCT U/W DRILLS. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Engineering
Issued 6 May 1999 Resolved
REPLACE HANDLE ON PORT FUEL TANK SHUTOFF VALVE.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Engineering
Issued 6 May 1999 Resolved
PROVIDE SECOND SENSOR FOR VAPOR DETECTOR IN FWD BILGE AREA.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Engineering
Issued 6 May 1999 Resolved
SEAL GAS TANK COMPT AT BILGE AND REMOVE GRATE FROM OPENING.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Construction/Loadline
Issued 1 June 1998 Resolved
PROVIDE VALVE FOR MSD DISCHARGE FITTING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 June 1998
Resolved 7 July 1998
Navigation
Issued 1 June 1998 Resolved
RENEW PACKING IN RUDDER STUFFING TUBE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 June 1998
Resolved 7 July 1998
Construction/Loadline
Issued 1 June 1998 Resolved
ADDRESS ROT IN PLANK END AT PORT QUARTER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 June 1998
Resolved 7 July 1998
Navigation
Issued 10 March 1998 Resolved
REPAIR MASTHEAD LIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998 Resolved
PROVIDE NEW RING BUOY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998 Resolved
PROVIDE 3 ADULT PFDS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Navigation
Issued 10 March 1998 Resolved
PROVIDE OPERABLE HORN.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1998 Resolved
SERVICE ALL FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998 Resolved
CONDUCT SATISFACTORY UNDERWAY DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Engineering
Issued 10 March 1998 Resolved
CONDUCT SATISFACTORY UNDERWAY TESTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Navigation
Issued 10 March 1998 Resolved
PROVIDE CURRENT CHART OF OPERATING AREA.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Unknown
Issued 10 March 1997 Resolved
The owner did not have a log book for the vessel as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Lifesaving
Issued 10 March 1997 Resolved
Some of the retro reflective tape on the B/A was worn and missing._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Accommodation/Occupational Safety
Issued 10 March 1997 Resolved
The bilge of the vessel had excessive trash in it which could interfere with the bilge pump operation._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Lifesaving
Issued 10 March 1997 Resolved
The line on the ring buoy was not made of a buoyant material as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Engineering
Issued 10 March 1997 Resolved
Some of the hose connections on the water cooling system of the main enginedid not have double hose clamps as required._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Unknown
Issued 10 March 1997 Resolved
Owner has not updated his current drug testing program with his consortium._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Lifesaving
Issued 10 March 1997 Resolved
The flares are not in a properly marked container as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 10 March 1997 Resolved
The portable fire extinguishers have not been recently serviced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 10 March 1997 Resolved
The fixed halon system has not been recently serviced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Accommodation/Occupational Safety
Issued 10 March 1997 Resolved
The grab rail on top of the house on the starboard side is wasted and should be repaired/replaced._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Engineering
Issued 10 March 1997 Resolved
One of the two hose clamps around the rubber sleeve on the shaft packing was missing._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 13 June 1996 Resolved
The caulking in the gap were the stem and the planking, starboard side on the bow was missing allowing water to enter the hull._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Engineering
Issued 13 June 1996 Resolved
The exhaust hose to the main engine compartment was improperly located to adequately exchange the air within the compartment._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Engineering
Issued 13 June 1996 Resolved
The flexible hose in the fuel line was connected with only 1 hose clamp at each fitting._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Electrical
Issued 13 June 1996 Resolved
There are several wires that are unsupported and laying in the bilge in various locations._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Construction/Loadline
Issued 13 June 1996 Resolved
Frames 4-7, starboard side, forward compartment are rotted were they attatch to the chine._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Construction/Loadline
Issued 13 June 1996 Resolved
There is a plug in the hull under the toilet that does not have a backing block on it._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Electrical
Issued 13 June 1996 Resolved
There are several dead end wires located throughout the vessel._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Construction/Loadline
Issued 18 April 1996 Resolved
REPAIR/REPLACE PORT SIDE AUTOMATIC BILGE PUMP SWITCH.
Condition: Unknown
Due 24 April 1996
Resolved 1 May 1996
Navigation
Issued 18 April 1996 Resolved
REPLACE STARBOARD SIDELIGHT AS NEW I.A.W. 46CFR183.420
Condition: Unknown
Due 19 April 1996
Resolved 23 April 1996
Construction/Loadline
Issued 22 April 1993 Resolved
Crop and renew plank on starboard side near aft end of cabin.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 22 April 1993 Resolved
Crop and renew planking port side aft to eliminate decay in various planks.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 23 April 1991 Resolved
CONDUCT UNDERWAY TEST
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Navigation
Issued 23 April 1991 Resolved
REPOSITION MASTHEAD LIGHT SO BULB IS COMPLETELY POSITIONED
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Fire Fighting
Issued 23 April 1991 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Construction/Loadline
Issued 23 April 1991 Resolved
FIX/REPLACE ROT IN PLANKS, PORT SIDE, AFT HALF VSL, ABOVE CHINE STRAKE, AS APPROPRIATE
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Engineering
Issued 23 April 1991 Resolved
REFLARE FUEL LINE OFF FROM PORT FUEL TANK
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Engineering
Issued 23 August 1990 Resolved
REPLACE BILGE VENT FAN PRIOR TO 30AUG90
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Navigation
Issued 22 May 1990 Resolved
PLACE COPY OF LIGHT LIST ON VESSEL
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Engineering
Issued 22 May 1990 Resolved
INSTALL ENGINE/BLOWER INTERLOCK ON VESSEL
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Documentation
Issued 22 May 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Unknown
Issued 27 July 1989 Resolved
RENEW FIRST SIDE PLANK STBD BOW
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
RENEW SISTER KEELSON AFT PORT SIDE
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
REMOVE ROT FROM PORT SIDE SHAFT LOG
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
PROVIDE BUTT BLOCK FOR WOODEN PLUG PORT MIDSHIP
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
DOUBLE CLAMP THRU-HULL FITTINGS
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
RENEW SEASUCTION 1-1/4 GATE VALVE
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
RENEW TWO BOTTOM PLANKS PORT BOW
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Unknown
Issued 27 July 1989 Resolved
RENEW ONE BOTTOM PLANK STBD BOW
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 20 June 1989 Resolved
PROVIDE PROPER SIZE WEAK LINK FOR BOUYANT APPARATUS. PROPERLY ATTACH TO VESSEL AND B/A
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Construction/Loadline
Issued 20 June 1989 Resolved
REPLACE SHORT SISTER ON LONGITUDNAL KEELSON, STBD SIDE ALONG ENGINE WITH ONE TWICE AS LONG
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Navigation
Issued 20 June 1989 Resolved
PROVIDE COPY OF INLAND NAVIGATION RULES
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Construction/Loadline
Issued 20 June 1989 Resolved
REPAIR LEAK AT STERN POST. VSL TO BE HAULED 17JUL89
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 14 July 1988 Resolved
PROPERLY BLOCK BATTERY IN BOX LOCATED AFT.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Engineering
Issued 14 July 1988 Resolved
PROVIDE ELECTRICAL GROUND FOR FUEL TANKS. ABOVE REQUIREMENTS ACTUAL COMPLIANCE DATE: 14AUG88
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Lifesaving
Issued 14 July 1988 Resolved
PROVIDE WATERLIGHT FOR RING BOUY. LIMITED TO DAYLIGHT OPERATIONS UNTIL PROVIDED.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Lifesaving
Issued 14 July 1988 Resolved
PROVIDE SIX ADULT PFD'S. PASSENGERS LIMITED TO 15 UNTI PROVIODED.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Electrical
Issued 14 July 1988 Resolved
REMOVE ALL WIRENUTS THROUGHOUT VESSEL AND REPLACE WITH MECHANICAL CRIMP CONNECTIONS.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Electrical
Issued 14 July 1988 Resolved
REMOVE UNUSED ELECTRICAL CABLE BELOW NAV PANEL.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Engineering
Issued 14 July 1988 Resolved
PROVIDE REACH RODS TO ENABLE FUEL SHUT OFF TO BE EASILY ACCESSIBLE.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 22 October 1987 Resolved
PROVIDE THE FOLLOWING CHARTS & PUBLICATIONS: CHART OF OPERATING AREA; LIGHT LIST; NOTICE TO MARINERS; TIDE TABLES; CURRENT TABLES, AND 46CFR 166-199.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Unknown
Issued 22 October 1987 Resolved
RENEW THE AFTERMOST TRANSFERSE FRAME.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Unknown
Issued 22 October 1987 Resolved
RENEW BILGE PUMP DISCHARGE HOSES WITH REINFORCED, OIL RESISTANT HOSE OR FIXED PIPING.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Unknown
Issued 22 October 1987 Resolved
INSTALL MECHANICAL EXHAUST VENTLATION FOR THE BILGES IAW 46CFR 182.15-45. SUBMIT DRAWINGS OF PROPOSED INSTALLATION BEFORE INSTALLING THE UNIT. DRAWINGS SHALL INCLUDE BLOWER LOCATION DUCTING, MATERIALS USED AND WIRING DIAGRAM.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Unknown
Issued 22 October 1987 Resolved
INSTALL COVER ON BATTERY BOX BY ENGINE.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.