BIO LAB

BIO LAB is a 1947 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1985, most recently in April 2026, along with 46 deficiencies and 2 casualty investigations between 2012 and 2015.

Records from 1985 to 2026. Most recent: inspection, 15 April 2026.

Built
1947
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYN4822
Flag
UNITED STATES
367007650
Maury page id
psix-42370

Inspections, by type

…with no type recorded3
Years with a record 38 calendar years (1985–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.3 ft × 11.9 ft × 5.1 ft
Registered tonnagegross 19 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVERMILION ENGINEERING CO · VERMILION, OH, UNITED STATES · built 1947
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPUT IN BAY, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6086MMSI 367007650 · active · compulsorily equipped · granted 18 September 2025, expires 18 September 2035
WYN4822MMSI 367007650 · expired · compulsorily equipped · granted 9 January 2015, cancelled 24 May 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

15 April 2026 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8349861
16 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8187463
7 November 2024 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8034114
1 November 2023 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7824693
21 October 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7581576
3 November 2021 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7377046
22 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7082483
14 November 2019 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6856203
4 March 2019 Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6635966
2 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6574708
29 November 2017 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6314612
1 November 2017 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6298237
25 October 2016 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6030946
17 September 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5218625
21 August 2014 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4931250
10 July 2012 In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4380421
19 June 2012 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4348728
18 June 2012 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4355945
2 December 2009 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3641500
11 May 2009 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3472523
4 June 2008 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3226278
4 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2951355
9 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2852949
8 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2674164
6 June 2006 Simplified Stability Test · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2621214
3 June 2005 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2378073
10 November 2004 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2233175
23 June 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2108577
2 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2085004
13 June 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1815722
17 May 2002 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1621999
12 July 2001 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1068616
11 June 2001 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1457944
15 December 1999 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1393297
17 May 1999 Damage Survey · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1436198
22 May 1998 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 791829
23 May 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1400582
24 May 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1084743
22 May 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1417780
11 April 1995 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1357225
27 May 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1019281
25 May 1993 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1142367
21 May 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 952077
28 May 1991 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1225642
21 May 1990 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1216696
2 February 1990 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 915401
25 May 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1339871
23 May 1988 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1352191
21 May 1987 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1025358
28 May 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 986289
30 May 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1295362
8 January 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1286192

Deficiency record · 46

Construction/Loadline › Hull › Bottom Plating
Issued 28 February 2018 Resolved
Conduct ultrasonic (UT) gauging of vessels hull to determine the extent of pitting found during hull exam. Conduct a minimum of 03 belts, 1 forward, 1 amidships, and 1 aft. Make repairs as required based on the gauging report.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 23 May 2019
Resolution: Entire hull plate has been renewed.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2018 Resolved
Make permanent repairs to all wasted sections of rub rail and wasted sideshell plating in way of rubrail.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 23 May 2019
Resolution: Hull plate has been renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 June 2009 Resolved
The vessel rail height is approximately 30 inches. O/O shall install proper rails of a height of no less than 36 inches in accordance with 46 CFR 177.35-1, and with rail courses, or bulwarks with spacing not to exceed 12 inches.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 April 2010
Resolution: Operator extended the deck rail stanchions and added chain to meet required railing height.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 June 2009 Resolved
Vessel shall install suitable warning device for engine exhaust cooling in accordance with 46 CFR 182.425 (b)(5) in a point after the heat exchanger.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 5 April 2010
Resolution: Vessel has installed a high temp temperature sensor on exhaust and installed an audible and visual alarm at the operating station.
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 4 June 2007 Resolved
Replace tie straps with rigid chain or cable life lines.
Condition: Improper Installation
Due 6 July 2007
Resolved 4 June 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 4 June 2007 Resolved
Replace both short sections of radiator hose.
Condition: Improper/Lack of Maintenance
Due 6 July 2007
Resolved 4 June 2008
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 6 June 2006 Resolved
Ensure each B/A has a float light attached. Currently there are two B/A's and only one light.
Condition: Improper Installation
Due 6 July 2006
Resolved 8 June 2006
Resolution: Float light attached to both BA''s.
Stability › Watertight Integrity › Coaming
Issued 6 June 2006 Resolved
Ensure engineroom hatch is weather tight.
Condition: Unknown
Due 6 July 2006
Resolved 8 June 2006
Resolution: Engineroom hatch seal made weathertight.
Stability › Watertight Integrity › General
Issued 6 June 2006 Resolved
Permanently repair small deck fracture IWO the port anchor windless
Condition: Unknown
Due 1 January 2007
Resolved 7 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 June 2005 Resolved
Prior to carrying passengers, replace retro on all adult pfd's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 16 June 2005
Engineering › Steering Gear System › Linkage
Issued 3 June 2005 Resolved
Prior to 09 June 05, install an upper & lower steering cable guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 16 June 2005
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 3 June 2005 Resolved
Repair generator raw water leak at the top of the muffler prior to operating the gen set.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 16 June 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 June 2005 Resolved
Replace mde "checked" raw water hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 16 June 2005
Engineering › Bilge Water Management System › Pump
Issued 3 June 2005 Resolved
Prove proper operation of the installed hand bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 16 June 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 3 June 2005 Resolved
Insure B/A'S are bright orange in color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 16 June 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 June 2005 Resolved
Ensure that the adult pfd's & child pfd's are seperated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 16 June 2005
Lifesaving › Lifebuoys › Serviceable
Issued 3 June 2005 Resolved
Replace vessel life ring prior to 01 Jan 06
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 16 June 2005
Engineering › Steering Gear System › Rudder
Issued 10 November 2004 Resolved
Rudder needs to be removed and have the bottom bushing replaced, bushing failed due to the locking collar on the top of the rudder is missing it's locking bolt. This has resulted in a loose rudder assmy.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 10 November 2004 Resolved
Cutlas bearing has cracked in a few places.
Condition: Improper/Lack of Maintenance
Due 1 April 2005
Resolved 6 April 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 November 2004 Resolved
Gen set exhaust through hull is missing a overboard valve due to the location of the valve which is approx less than 6" above the water line.
Condition: Design Flaw
Due 1 April 2005
Resolved 6 April 2005
Engineering › Bilge Water Management System › Pump
Issued 10 November 2004 Resolved
Bilge pump discharge hose is kinked and in need of replacement, reccommended that a 90 deg elbow is placed in to fix the bend on the hose due to location.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Engineering › Bilge Water Management System › Not Installed
Issued 10 November 2004 Resolved
PTO is missing a shield over the belts, this a major safety hazard. Boat needs to install a gaurd.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 10 November 2004 Resolved
Fuel gauge wire needs to be properly hung with steel hangors.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Stability › Watertight Integrity › General
Issued 10 November 2004 Resolved
Clad welding needs to be added to damaged area under the water line below 1st bit up forward stbd side.
Condition: Damaged By Earlier Event
Due 1 April 2005
Resolved 6 April 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 November 2004 Resolved
Junction box in engine room missing cover on the box, needs to be installed.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Engineering › Bilge Water Management System › Hose
Issued 10 November 2004 Resolved
Discharge hose off of pump is cracked and needs to be replaced, itt jabsco bilge/firepump.
Condition: Damaged By Earlier Event
Due 1 April 2005
Resolved 6 April 2005
Construction/Loadline › Hull › Weld
Issued 10 November 2004 Resolved
Deck plating on main deck has seperated from the frame supports on the stbd side main deck.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Construction/Loadline › Penetrations › Weld
Issued 10 November 2004 Resolved
Engine hatch has approx 7" of missing combing, and has a broken hatch hinge.
Condition: Improper Installation
Due 1 April 2005
Resolved 6 April 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 10 November 2004 Resolved
Forward extinguisher in the pilot house has a gauge reading in the dischagre side, needs to have it serviced.
Condition: Improper/Lack of Maintenance
Due 1 April 2005
Resolved 6 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 10 November 2004 Resolved
Transducer has a cracked base which could lead to water entry, needs to be relaced, fwd stbd transducer.
Condition: Damaged By Earlier Event
Due 1 April 2005
Resolved 6 April 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 June 2004 Resolved
Install fuel shut off valve as close to fuel tank as possible. Valve must be accessible from deck for emergency shut off.
Due 2 July 2004
Resolved 23 June 2004
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 June 2004 Resolved
Install fuel shut off valve as close to engine as possible.
Due 2 July 2004
Resolved 23 June 2004
Lifesaving › Buoyant Apparatus
Issued 2 June 2004 Resolved
Locate data plate and find CG approval number for BA.
Due 7 June 2004
Resolved 2 June 2004
Resolution: Someone had put fiberglass over data plate and then painted it. Rep cut covering away to expose plate and found CG approval number.
Documentation › Certificates/Documents
Issued 13 June 2003 Resolved
PROVIDE COPY OF VALID CERTIFICATE OF DOCUMENTATION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 13 July 2003
Resolved 13 July 2003
Resolution: Copy of Certificate of Documentation was faxed to this office.
Communications › Radio Communications
Issued 13 June 2003 Resolved
VESSEL LIMITED TO THE WATERS OF PUT-IN-BAY BETWEEN THE OHIO STATE RESEARCH DOCK AND GIBRALTAR ISLAND UNTIL THE EPIRB BATTERY IS RENEWED BY AN APPROVED FACILITY. LEGACY COMPONENT DESC: EPIRB
Due 20 June 2003
Resolved 16 June 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 June 2003 Resolved
ENSURE CONTENTS OF FIRST AID KIT COMPLY WITH 46 CFR 160.041. LEGACY COMPONENT DESC: Medicine Chest
Due 13 July 2003
Resolved 13 July 2003
Resolution: New first aid kit was purchased and a copy of the receipt was fax to this office.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2003 Resolved
STERN LIGHT INOPERATIVE.
Due 13 June 2003
Resolved 13 June 2003
Resolution: CHANGED BULB
Navigation
Issued 11 June 2001 Resolved
Ensure steering cable does not rub on deck frame.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: MISLE 5.0 transition error
Construction/Loadline
Issued 11 June 2001 Resolved
Permanently affix bilge pump to satisfaction of CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: MISLE 5.0 transition error
Construction/Loadline
Issued 11 June 2001 Resolved
Prove proper operation of high water bilge indicator light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: MISLE 5.0 transition error
Electrical
Issued 17 May 1999 Resolved
PERMANENTLY WIRE IGNITION CABLE THROUGH INSTALLED CONDUIT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: MISLE 5.0 transition error
Navigation
Issued 17 May 1999 Resolved
DOUBLE CLAMP ALL SIX STEERING CABLE CONNECTION POINTS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: MISLE 5.0 transition error
Engineering
Issued 11 April 1995 Resolved
MAKE EXHAUST PIPING AVAILABLE FOR INSPECTION AFTER RENEWAL IS COMPLETED.
Condition: Unknown
Due 30 April 1995
Resolved 7 July 1995
Construction/Loadline
Issued 11 April 1995 Resolved
INSERT, @6", STBD SIDE PLATING IN WAY OF THE BILGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 30 April 1995
Resolved 7 July 1995
Construction/Loadline
Issued 11 April 1995 Resolved
DOUBLE CLAMP ALL SEA WATER/BILGE FLEXIBLE HOSE CONNECTIONS.
Condition: Unknown
Due 30 April 1995
Resolved 7 July 1995
Navigation
Issued 11 April 1995 Resolved
CROP AND RENEW WASTED AFT RUDDER POST SUPPORT BRACKET.
Condition: Unknown
Due 30 April 1995
Resolved 7 July 1995

Casualty record · 2

18 June 2012Routine · role: Involved in a Marine Casualty · activity 4355945
2 June 2015Routine · role: Involved in a Marine Casualty · activity 5142043
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.