MAURY USCG vessel records Sign in
← All vessels

ANNIE BERMAN *

ANNIE BERMAN * is a 1913 tank barge. The Coast Guard has recorded 12 inspections since 1985, most recently in September 1991, along with 7 deficiencies.

Records from 1985 to 1991. Most recent: inspection, 5 September 1991.

Built
1913
Last inspected
5 September 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-42375

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (1985–1991)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it385 - Regulatory (Subpart C or D), Net Ton
385 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

5 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948146
8 February 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223470
21 April 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341417
21 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344941
12 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312604
21 September 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1316319
11 September 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006705
11 September 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006709
15 January 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007013
13 January 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005463
7 January 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300356
17 January 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978465

Deficiency record · 7

Electrical
Issued 13 January 1987 Resolved
TEST THE LOW LUBE OIL ALARM ON THE SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Engineering
Issued 13 January 1987 Resolved
INSULATE STEAM PIPE AND HEAT EXCHANGER FOR WATER TANK WASH SYSTEM.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Fire Fighting
Issued 13 January 1987 Resolved
REPLACE VALVE IN FUEL LINE FOR FIXED FIRE PUMP.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Electrical
Issued 13 January 1987 Resolved
REMOVE DEAD ENDED CABLE FORWARD BULKHEAD, CENTER OF BOILER ROOM.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Construction/Loadline
Issued 13 January 1987 Resolved
HOSE TEST DECK PLATE REPAIRS TO FORWARD END STARBOARD SIDE OF DECK HOUSE.
Condition: Unknown
Due 13 January 1987
Resolved 13 January 1987
Construction/Loadline
Issued 17 January 1985 Resolved
PROVIDE HAILING PORT MARKING ON VESSEL'S STERN IN ACCORDANCE WITH TITLE 46 CFR 67.15-3.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Construction/Loadline
Issued 17 January 1985 Resolved
STRAIGHTEN OR RENEW #3 STARBOARD CARGO TANK HATCH SUCH THAT HATCH SEAL, WHEN DOGGED, IS VAPOR TIGHT.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985

Ownership record