Records from 1985 to 1991. Most recent: inspection, 4 March 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Accommodation/Occupational Safety
Issued 29 June 1987
Resolved
REMOVE PLASTIC THROUGH HULL FITTING, REPLACE WITH METALLIC AND PROVIDE ONE CHECK VALVE WHERE MISSING.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
RELOCATE ONE RING BUOY FROM LOWER FWD ACCOMMODATION SPACE, TO OPEN DECK IN WAY OF WHEELHOUSE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987
Resolved
MAKE MAIN DECK WATERTIGHT PRESENTLY LEAKING THROUGHOUT VESSEL.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Engineering
Issued 29 June 1987
Resolved
REPLACE ALL NON-REINFORCED ELECTRICAL BILGE PUMP HOSES WITH REINFORCED HOSE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987
Resolved
OPEN BULKHEAD IN ACCOMMODATION SPACE FOR INTERNAL INSPECTION OF FRAMES WHERE INACCESSIBLE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
PROVIDE FOUR ADULT PFDS WHERE TOWN BEYOND REPAIR.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
PROVIDE NEW GRAB LINES ON TWO BUOYANT APPARATUS WHERE WORN.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
PROVIDE 12 HAND DISTRESS SIGNALS, PRESENT DISTRESS SIGNALS EXPIRED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Navigation
Issued 29 June 1987
Resolved
PROVIDE TWO MILE SIDE RUNIING LIGHTS, WHERE ONE MILE LIGHTS STAND.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
RE-STENCIL OR MARK VESSEL'S NAME ON TWO BUOYANT APPARATUS, WHERE FADED OUT.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987
Resolved
REMOVE 10 FASTENERS IN WAY OF TURN OF THE BILGE (5 PORT, 5 STBD) FOR INSPECTION OF SAME.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
ATTACH WEAK LINK TO PAINTER ON BUOYANT APPARTUS AND SECURE SAME TO VESSEL, PRESENTLY DETACHED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Fire Fighting
Issued 29 June 1987
Resolved
PROVIDE ONE B-I PORTABLE FIRE EXTINGUISHER FOR WHEELHOUSE, PRESENT EXTINGUISHER DISCHARGED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987
Resolved
OPEN SURVEY VALVE TO MSD SUPPLY, PRESENTLY NOT OPEN FOR INSPECTION.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 2 June 1986
Resolved
MARK OR STENCIL AMOUNT AND SIZE OF PFD'S ON STOWAGE COMPARTMENT, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986
Resolved
PROVIDE OPERATIONAL TEST OF MDE IN ALL MODES, PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Electrical
Issued 2 June 1986
Resolved
REMOVE NON-CG-APPROVED PORTABLE GASOLINE AUXILIARY GENERATOR FROM VESSEL.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Electrical
Issued 2 June 1986
Resolved
REMOVE ALL WIRE NUTS FROM ELECTRICAL WIRING ON BRIDGE REPLACE WITH SOLDER, FRICTION TAPE AND PLASTIC TAPE.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986
Resolved
REPLACE ALL NON-APPROVED (FLEX) FUEL LINES ON MAIN DIESEL ENGINE, WITH CG APPROVED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Construction/Loadline
Issued 2 June 1986
Resolved
REPLACE NON-APPROVED PLASTIC WATERTIGHT HATCH ON MAIN DECK AFT, WITH CG APPROVED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986
Resolved
REPAIR OR REPLACE 2 ADULT PFD'S, AND 1 CHILD PFD, WHERE TORN OR DETERIORATED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Fire Fighting
Issued 2 June 1986
Resolved
RECHARGE OR RENEW 1-3# DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, WHERE DISCHARGED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986
Resolved
MARK OR STENCIL VESSEL'S CORRECT NAME ON ALL ADULT AND CHILD PFD'S, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986
Resolved
MARK OR STENCIL VESSEL'S NAME AND AMOUNT OF PERSONS ON 2 BUOYANT APPARATUS'WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986
Resolved
MARK OR STENCIL LOCATION OF 2 EMERGENCY FUEL SHUT-OFF'S, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986