PROWLER II is a 1947 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 1985, most recently in March 1991, along with 25 deficiencies.

Records from 1985 to 1991. Most recent: inspection, 4 March 1991.

Built
1947
Last inspected
4 March 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WB5894
Flag
UNITED STATES
—
Maury page id
psix-42377

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (1985–1991)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

4 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242890
20 July 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023093
29 June 1987 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321694
13 November 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323822
2 June 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988339
11 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288749
6 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288847

Deficiency record · 25

Accommodation/Occupational Safety
Issued 29 June 1987 Resolved
REMOVE PLASTIC THROUGH HULL FITTING, REPLACE WITH METALLIC AND PROVIDE ONE CHECK VALVE WHERE MISSING.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
RELOCATE ONE RING BUOY FROM LOWER FWD ACCOMMODATION SPACE, TO OPEN DECK IN WAY OF WHEELHOUSE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987 Resolved
MAKE MAIN DECK WATERTIGHT PRESENTLY LEAKING THROUGHOUT VESSEL.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Engineering
Issued 29 June 1987 Resolved
REPLACE ALL NON-REINFORCED ELECTRICAL BILGE PUMP HOSES WITH REINFORCED HOSE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987 Resolved
OPEN BULKHEAD IN ACCOMMODATION SPACE FOR INTERNAL INSPECTION OF FRAMES WHERE INACCESSIBLE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
PROVIDE FOUR ADULT PFDS WHERE TOWN BEYOND REPAIR.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
PROVIDE NEW GRAB LINES ON TWO BUOYANT APPARATUS WHERE WORN.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
PROVIDE 12 HAND DISTRESS SIGNALS, PRESENT DISTRESS SIGNALS EXPIRED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Navigation
Issued 29 June 1987 Resolved
PROVIDE TWO MILE SIDE RUNIING LIGHTS, WHERE ONE MILE LIGHTS STAND.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
RE-STENCIL OR MARK VESSEL'S NAME ON TWO BUOYANT APPARATUS, WHERE FADED OUT.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987 Resolved
REMOVE 10 FASTENERS IN WAY OF TURN OF THE BILGE (5 PORT, 5 STBD) FOR INSPECTION OF SAME.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987 Resolved
ATTACH WEAK LINK TO PAINTER ON BUOYANT APPARTUS AND SECURE SAME TO VESSEL, PRESENTLY DETACHED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Fire Fighting
Issued 29 June 1987 Resolved
PROVIDE ONE B-I PORTABLE FIRE EXTINGUISHER FOR WHEELHOUSE, PRESENT EXTINGUISHER DISCHARGED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 29 June 1987 Resolved
OPEN SURVEY VALVE TO MSD SUPPLY, PRESENTLY NOT OPEN FOR INSPECTION.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 2 June 1986 Resolved
MARK OR STENCIL AMOUNT AND SIZE OF PFD'S ON STOWAGE COMPARTMENT, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986 Resolved
PROVIDE OPERATIONAL TEST OF MDE IN ALL MODES, PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Electrical
Issued 2 June 1986 Resolved
REMOVE NON-CG-APPROVED PORTABLE GASOLINE AUXILIARY GENERATOR FROM VESSEL.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Electrical
Issued 2 June 1986 Resolved
REMOVE ALL WIRE NUTS FROM ELECTRICAL WIRING ON BRIDGE REPLACE WITH SOLDER, FRICTION TAPE AND PLASTIC TAPE.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986 Resolved
REPLACE ALL NON-APPROVED (FLEX) FUEL LINES ON MAIN DIESEL ENGINE, WITH CG APPROVED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Construction/Loadline
Issued 2 June 1986 Resolved
REPLACE NON-APPROVED PLASTIC WATERTIGHT HATCH ON MAIN DECK AFT, WITH CG APPROVED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986 Resolved
REPAIR OR REPLACE 2 ADULT PFD'S, AND 1 CHILD PFD, WHERE TORN OR DETERIORATED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Fire Fighting
Issued 2 June 1986 Resolved
RECHARGE OR RENEW 1-3# DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, WHERE DISCHARGED.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986 Resolved
MARK OR STENCIL VESSEL'S CORRECT NAME ON ALL ADULT AND CHILD PFD'S, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986 Resolved
MARK OR STENCIL VESSEL'S NAME AND AMOUNT OF PERSONS ON 2 BUOYANT APPARATUS'WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Engineering
Issued 2 June 1986 Resolved
MARK OR STENCIL LOCATION OF 2 EMERGENCY FUEL SHUT-OFF'S, WHERE MISSING.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.