MAURY USCG vessel records Sign in
← All vessels

SERENITA

SERENITA is a 1995 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1995, most recently in January 2025, along with 144 deficiencies — 1 with no resolution recorded —.

Records from 1995 to 2025. Most recent: inspection, 28 January 2025.

Built
1995
Last inspected
28 January 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY9364
424022
Flag
UNITED STATES
367389430
Maury page id
psix-424022

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 27 calendar years (1995–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 22.0 ft × 5.0 ft
Registered tonnagegross 76 / net 76
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDOLPHIN PAC SAIPAN INC · SAIPAN, MP, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSAIPAN, MP
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Simplified, Gross Ton
76 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY9364MMSI 367389430 · active · compulsorily equipped · granted 21 February 2019, expires 11 March 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

28 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8071300
16 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7913275
24 February 2023 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7641767
18 January 2023 Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7623484
3 July 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7003637
8 March 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6922644
28 February 2019 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6633842
26 March 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6379232
22 December 2017 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6327787
5 January 2017 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6066103
8 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5799269
3 January 2016 Examination of Repairs · Hull Examination · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5790061
4 November 2015 DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5761795
19 August 2014 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4959178
30 July 2012 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4396293
27 February 2012 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4251534
14 February 2012 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4243868
29 March 2010 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3704449
23 February 2010 Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3688213
14 April 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3454310
19 February 2008 Deficiency Check · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3149451
6 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2882405
13 February 2007 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2868827
15 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2649060
9 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2644331
1 March 2006 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2593672
28 November 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2545695
28 March 2005 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2320758
24 March 2005 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2318160
15 March 2004 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2029383
23 February 2004 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2011150
2 July 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1832585
15 June 2003 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1817511
27 May 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1802109
20 May 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1797160
17 March 2003 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1758099
11 June 2002 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1630221
9 April 2002 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 1620716
9 April 2002 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 1621294
14 February 2002 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1487235
14 March 2001 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1060499
15 February 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1376458
12 January 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361937
7 August 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1053763
28 March 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1047501
1 March 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1393351
1 April 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1126778
2 March 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1360745
8 December 1998 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364988
15 January 1998 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 782376
3 June 1997 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115922
30 May 1997 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115921
23 May 1996 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1090465
13 May 1995 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1080551

Deficiency record · 144

01 - Certificates & Documentation › 011 - Ships Certificates › Liability of carriage of passengers certificate
Issued 28 January 2025 No resolution recorded
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. The SERENITA dry dock due date is January 31, 2025. The vessel is not permitted to conduct commercial passenger operations until a dry dock exam is completed. 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2025 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2024 Resolved
When the cognizant OCMI or the Commanding Officer, Marine Safety Center determines, in accordance with § 178.210, that a vessel must have stability details indicated on its Certificate of Inspection or a stability letter, the owner or operator must submit the information listed in paragraph (b) of this section to include location, type and amount of fixed ballast. When necessary for safe operation, the cognizant OCMI may place specific stability restrictions in a stability letter or on the Certificate of Inspection of a vessel not more than 65 feet (19.8 meters) in length, which, under § 178.310 of this part, complies with the requirements of § 178.320 of this part. The valid stability letter, issued under a simplified stability test, does not list any ballast onboard and restricts the installation of ballast onboard without notifying the [name withheld] identified several hundred pounds of lead ballast stored in storage bins on the bow. The lead ballast was placed onboard without notifying the OCMI. 46 CFR 178
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2024
Resolved 30 May 2024
Resolution: The ballast was removed from the vessel. The vessel is now in compliance with the stability letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. The starboard hull bilge pump was found leaking at the impeller gland when tested. The bilge pump cannot provide suction from each space. 46 CFR 182.25-1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2024
Resolved 30 May 2024
Resolution: The gasket for the pump impeller was replaced and the pump was found to be in good operation when tested by the crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2024 Resolved
On a vessel of at least 26 ft in length, visual and audible alarms must be provided at the operating station to indicate a high water level in each space identified in 182.530. The audible bilge alarm was not operational when tested. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2024
Resolved 30 May 2024
Resolution: All bilge high level alarms were tested. The audible alarm for each of the three spaces in each hull was found to be in good order.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
Fuses must be of the cartridge type only and be listed by UL. Each circuit breaker must be UL 489. Identified a blade 40 amp fuse on the conductor from the battery under the operating. Blade fuses are not cartridge UL listed fuses. Identified two 50 amp anchor breakers on the fire pump/bilge pump conductors located at the stern. Anchor breakers are not UL 489 listed. The breakers and fuses are considered new T installations as they are not original to the vessel construction. 46 CFR 183.380
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
Resolution: The blade fuse and unapproved breakers were replaced with a 30 amp UL listed class RK-5 fuse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
Batteries shall be secured against shifting with motion of the boat. The main engine starting batteries are not secured for movement and can be easily moved by hand inside of the storage compartment. 46 CFR 183.05-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
Resolution: The starting batteries have a metal bar over the top the is affixed to the bottom of the storage compartment and the batteries cannot be moved in any direction.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2024 Resolved
Each life float shall have SOLAS type II retro reflective tape installed. The retro reflective tape on all three life floats was found worn and faded. In some cases it was found peeling off. 46 CFR 160.010
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 14 August 2024
Resolution: The operator installed new SOLAS retro reflective tape on the life rafts.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2024 Resolved
The life float shall be equipped with two paddles. The wood paddles in two life floats were found fractured in not in operational condition. 46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
Resolution: The fractured life float paddles were removed from the vessel and replaced like and in kind.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2023 Resolved
Repair inoperable light in passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 27 February 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 February 2023 Resolved
Install captive chains on starboard aft deck hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 24 February 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 February 2023 Resolved
Show proper operation of PA system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 24 February 2023
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2023 Resolved
Mark starboard fuel tank emergency shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 24 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2020 Resolved
Passenger and crew must be protected from contact energized electrical equipment. Properly remove death end wires located aft of main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2020
Resolved 17 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2020 Resolved
Electrical equipment expose to weather must be watertight. Relocate light switch from deck level port entrance to location that is not expose to weather, water wash down.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2020
Resolved 17 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2020 Resolved
Install missing fixture light cover in main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2020
Resolved 17 July 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2019 Resolved
Wiring shall be to satisfaction of [name withheld] was two electrical wires of different sizes in the port side void spaces that were attached using a splice and electrical tape. These wires are to be attached using proper connectors. Wires leading to the batteries were chaffing in spots and chaffing gear should be used to prevent wear.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Vessel properly connected wires
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2019 Resolved
The life float paddles are required to be lashed to the life float. Lash the paddles to the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Vessel lashed life float paddles
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2019 Resolved
The Life Float painter lines are cracking and falling apart. Replace life float painter lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Vessel replaced painted lines
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 28 February 2019 Resolved
Garbage Management Plan is required for a vessel over 40ft engaged in coastwise service beyond 3 miles. Your vessel is certificated for coastwise trade and is authorized beyond 3 miles. Provide a plan.
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 28 February 2019
Resolution: Company provided a plan
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 February 2019 Resolved
EPIRB to be tested monthly. Log EPIRB test.
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 28 February 2019
Resolution: Vessel logged EPIRB test
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 March 2018 Resolved
Master shall ensure that EPIRB is tested monthly as required by 46 CFR 185.25-20. Provide proof of monthly test performed on EPIRB.
Due 3 April 2018
Resolved 27 March 2018
Navigation › Piloting/Steering › Marine Charts
Issued 26 March 2018 Resolved
Vessel must carry appropriate charts for intended voyage as required by 46 CFR 185.20-35. Provide charts for LCW route.
Due 3 April 2018
Resolved 27 March 2018
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 March 2018 Resolved
Life float must have approved water light as required by 46 CFR 180.15-5. Repair inoperable water light on life float.
Due 3 April 2018
Resolved 27 March 2018
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 26 March 2018 Resolved
All vessel shall be provided with a hand operated portable fire pump having capacity of at least 5 gallons per minutes as required by 46 CFR 181.10-5. Provide hand operating fire pump on board.
Due 3 April 2018
Resolved 27 March 2018
Engineering › Steering Gear System › Interlock
Issued 26 March 2018 Resolved
Vessel shall provide suitable steering apparatus as required by 46 CFR 182.30-1. Repair inoperable steering system to allow system to sync both outboard engine.
Due 3 April 2018
Resolved 27 March 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2018 Resolved
All electrical installations shall be to the satisfaction of the CG as required by 46 CFR 183.01-15. Install missing light covers and repair inoperable lights forward of main cabin
Due 3 April 2018
Resolved 27 March 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2017 Resolved
Found missing light fixture above port forward entrance. Install missing light fixture as required by 46 CFR 183.410.
Due 13 January 2017
Resolved 6 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 January 2017 Resolved
Found 8 new life jackets without vessel name marked. all lifejackets must be marked with vessel name as required by 46 CFR 185.604
Due 5 January 2017
Resolved 6 January 2017
Lifesaving › Lifefloat › Approval
Issued 8 January 2016 Resolved
Submit survival craft replacement proposal to MI for review.
Due 26 February 2016
Resolved 8 January 2016
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 3 January 2016 Resolved
Vessel must carry adequate navigation rules as required by 46 CFR 184.420. No navigation rules on board. Provide Navigation rules book.
Due 10 February 2016
Resolved 6 January 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 January 2016 Resolved
Bilge pump must be suitable for dewatering the compartment as required by 46 CFR 176.840. Found STBD bilge pump with water leaking through the shaft seal. Replace damaged shaft seal.
Due 10 February 2016
Resolved 6 January 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 January 2016 Resolved
Deck railing must withstand a point load of 200 pounds as required by 46 CFR 177.900. Found loose fasteners on hand railing to control station. Repair loose railing
Due 10 February 2016
Resolved 6 January 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 January 2016 Resolved
Hatch exposed to weather deck must be watertight and be attached to captive chains as required by 46 CFR 179.360. Found missing captive chains on the two aft water tight hatches. Install captive chains.
Due 10 February 2016
Resolved 6 January 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 3 January 2016 Resolved
Propulsion machinery must have gauges to indicate engine RPM, temperature and oil pressure as required by 46 CFR 182.410. STBD propulsion engine has inoperable parameter gauges. Repair gauges in accordance with engine manufacture instructions.
Due 10 February 2016
Resolved 6 January 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 3 January 2016 Resolved
VHF must have DSC capability as required by 47 CFR 80.905 and MSIB 15-15. Upgrade vessel VHF .
Due 10 February 2016
Resolved 6 January 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 July 2012 Resolved
On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. The spacing below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Properly install in the spacing below the rail; bulwarks, chain link fencing, wire mesh, or any equivalent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2012
Resolved 30 August 2012
Resolution: Install mesh over hand rails.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 February 2012 Resolved
Post life jacket donning instructions.
Due 12 March 2012
Resolved 1 March 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2012 Resolved
Repair (03) light fixtures in passengers space.
Due 12 March 2012
Resolved 1 March 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 February 2012 Resolved
Provide (02) batteries with full charge. Found (02) on board batteries with low voltages.
Due 12 March 2012
Resolved 1 March 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 February 2012 Resolved
Found first aid kits with expired aspirin and missing eye wash solution. Update first aid kits.
Due 12 March 2012
Resolved 1 March 2012
Fire Fighting › Fire Pumps › Pumpshaft
Issued 27 February 2012 Resolved
Found deteriorated shaft couplings on both port and STBD fire/bilge pumps. Replace shaft couplings.
Due 12 March 2012
Resolved 1 March 2012
Engineering › Fuel Oil Service System › Tank
Issued 27 February 2012 Resolved
Replace damaged securing straps on port and STBD fuel tanks.
Due 12 March 2012
Resolved 1 March 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 February 2012 Resolved
Provide current CG light list.
Due 12 March 2012
Resolved 2 March 2012
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 February 2012 Resolved
Provide a copy of navigation rules on board.
Due 12 March 2012
Resolved 2 March 2012
Navigation › Piloting/Steering › Marine Charts
Issued 27 February 2012 Resolved
Provide update charts on board.
Due 12 March 2012
Resolved 2 March 2012
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 February 2012 Resolved
Provide current coast pilot on board.
Due 12 March 2012
Resolved 2 March 2012
Lifesaving › Lifefloat › Paddle
Issued 27 February 2012 Resolved
Replace damaged paddle for life float.
Due 12 March 2012
Resolved 2 March 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 February 2012 Resolved
Provide a proof of services completed on (04) B-II and (01 A-I.
Due 12 March 2012
Resolved 2 March 2012
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 February 2012 Resolved
Label valves on both port and STBD bilge manifolds.
Due 12 March 2012
Resolved 1 March 2012
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 February 2012 Resolved
Install missing valves handle on STBD bilge manifold.
Due 12 March 2012
Resolved 1 March 2012
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 27 February 2012 Resolved
Replace deteriorated anchor line.
Due 12 March 2012
Resolved 2 March 2012
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Found major wood decay in a way of STBD hull FWD of collision bulkhead. Submit plan for repair.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Found major wood decay in a way of STBD hull # 2 & 3 transverse frame. Submit plans for repairs.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Found major wood decay in a way of port hull space FWD of collision space. Submit plans for repairs.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Found major wood decay in a way of port hull # 1 transverse frame. Submit plans for repairs.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 14 February 2012 Resolved
Found major wood decay in a way of #2 & #8 deck transverse beam. Submit plans for repairs.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2012 Resolved
Found major wood decay in a way of AFTbulkhead behind bar. Submit plans for repairs.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 14 February 2012 Resolved
Prepare sewage tank area for inspection.
Due 17 February 2012
Resolved 21 February 2012
Construction/Loadline › Hull › Side Shell
Issued 14 February 2012 Resolved
Found 6 inches long crack in a way of port transom FWD of port outboard. Ground crack area to good lanimate and repair as original.
Action required: 705 - Other - as specified
Resolved 24 February 2012
Construction/Loadline › Hull › Transverse Frame
Issued 23 February 2010 Resolved
Found #4 & #5 deck beams infested with termites. Replace deck beams.
Due 9 March 2010
Resolved 5 March 2010
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2010 Resolved
Found hull crack on forward starboard hull inboard bow. Repair cracked hull.
Due 9 March 2010
Resolved 5 March 2010
Construction/Loadline › Structures › Superstructure
Issued 23 February 2010 Resolved
Found cracked window glass forward starboard window. Replace cracked on window glass.
Due 9 March 2010
Resolved 5 March 2010
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2010 Resolved
Found hull crack on port transom. Repair hull crack.
Due 9 March 2010
Resolved 28 February 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 February 2010 Resolved
Found loose deck railing on forward port Hull. Secure port railing.
Due 9 March 2010
Resolved 28 February 2010
Engineering › Fuel Oil Service System › Vent Pipe
Issued 14 April 2009 Resolved
Install 30x30 mesh screen on portside fuel vent.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 21 April 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 April 2009 Resolved
Renew life line on ring buoy.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 21 April 2009
Lifesaving › Lifefloat › Lifeline
Issued 14 April 2009 Resolved
Renew life line all life floats where deteriorating.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 29 March 2010
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 April 2009 Resolved
Renew retroreflective tape on all life floats.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 29 March 2010
Lifesaving › Lifefloat › Float-free Link
Issued 14 April 2009 Resolved
Prove proper breaking strength of weak link on life floats. Vessel is restricted to 3nm until corrected.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 29 March 2010
Communications › Radio Communications › EPIRB
Issued 14 April 2009 Resolved
Prove proper operation or expiry date on EPIRB's auto release mechanism. Vessel is restricted to 3nm until corrected.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 29 April 2009
Construction/Loadline › Hull › Side Shell
Issued 19 February 2008 Resolved
Crop and renew an approximate two (2) foot x eight (8) inch delaminating section of fiberglass two (2) feet forward of amidship on outboard side of port hull.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Repairs completed satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 19 February 2008 Resolved
Crop and renew an approximate six (6) inch x six (6) inch cracked section of fiberglass three (3) feet forward of amid ship on the outboard side of the port hull.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Repairs completed satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 19 February 2008 Resolved
Crop and renew an approximate three (3) foot by x ten (10) inch section of fiberglass in starboard hull second bay from bow overhead where delaminating has occurred.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Repairs completed satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 19 February 2008 Resolved
Crop and renew an approximate four (4) foot x ten (10) inch section of outboard side shell fiberglass in starboard hull second bay.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Repairs completed satisfactory.
Construction/Loadline › Hull › Transverse Frame
Issued 19 February 2008 Resolved
Make permanent repairs to fractured swash bulkhead in port hull third bulkhead from stern.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Another piece of marine plywood was married to existing, repairs completed satisfactory.
Construction/Loadline › Structures › Superstructure
Issued 19 February 2008 Resolved
Crop and renew rotten forward bulkhead starboard side main deck under windows, an approximate six (6) foot x four (4) foot section of plywood and fiberglass.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 February 2008
Resolution: Repairs completed satisfactory.
Construction/Loadline › Hull › Stiffener
Issued 19 February 2008 Resolved
Add three (3) additional deck stiffeners for top deck.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 25 February 2008
Resolution: Three additional stanchions added.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 February 2008 Resolved
Replaced cracked waterlight on starboard lifefloat.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 9 June 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 February 2008 Resolved
Repair or replace waterlight on aft lifefloat that has water in lens.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 9 June 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 February 2008 Resolved
Replace buoyant line on aft lifebuoy.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 9 June 2008
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2007 Resolved
Found charts not corrected with local notice to mariners. Prove all charts on board are corrected.
Due 13 March 2007
Resolved 6 March 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 February 2007 Resolved
Found vessel missing tidal current tables. Prove tidal current tables or calculation method is on board vessel.
Due 13 March 2007
Resolved 6 March 2007
Lifesaving › Hand Flares › Quantity
Issued 13 February 2007 Resolved
Found vessel missing two red hand flares. Prove all required signaling devices are on board vessel.
Due 13 March 2007
Resolved 6 March 2007
Lifesaving › Lifefloat › Float-free Link
Issued 13 February 2007 Resolved
Found all lifefloats not attached to the vessel with a weak link. Prove all lifefloats are attached to vessel via weak link.
Due 13 March 2007
Resolved 6 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2007 Resolved
Found multiple dead end wires in way of pilot station. Remove all dead end wires or end and lable in a junction box.
Due 13 March 2007
Resolved 6 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 13 February 2007 Resolved
Found lighting fixtures in storage room and the restroom without safety guards. Prove all lighting fixtures have suitable safety guards.
Due 13 March 2007
Resolved 6 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 13 February 2007 Resolved
Found three lighting fixtures on the main deck not properly operating. Prove proper operation of all lighting.
Due 13 March 2007
Resolved 27 June 2007
Construction/Loadline › Hull › Hull Plating
Issued 1 March 2006 Resolved
Issued 19 minor hull and ISE repairs to vessel. See Serenita Worklist in activity for specifics.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2006
Resolved 30 March 2006
Operations/Management › Drills/Instruction › Fire
Issued 1 March 2006 Resolved
Found crew was not logging Steering test, emergency drills, monthly fire and man over board drill in bridge log. Logged Steering test, emergency drills, monthly fire and man over board drill in bridge log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 9 May 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 March 2006 Resolved
Found vessel missing up to date chart and missing tidal current tables. Prove vessel has up to date charts and tidal current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 15 May 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 March 2006 Resolved
Found vessel missing required EPIRB. Prove vessel has approved EPIRB prior to operating beyond 3 mile from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 March 2006 Resolved
Found vessels lifebuoy retro reflective material worn. Repair or replace retro reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2006 Resolved
Found lifebuoy self igniting light without proper stenciling. Stencil vessel name to self igniting light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 March 2006 Resolved
Found forward light fixtures missing safety guards. Install safety guards on all exposed light bulbs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 March 2006 Resolved
Found vessel master unable to see man overboard recovery operations. Prove the vessels master can recover a man overboard.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Lifesaving › Buoyant Apparatus › Serviceable
Issued 24 March 2005 Resolved
Buoyant Apparatus - Provide 4 paddles, 1 water light, and repair water light brackets prior to operating 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2005
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 24 March 2005 Resolved
Replace Hydrostatic Release Unit expired 6/2004, prior to operating beyong three miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2006
Communications › Audible Communications › Horn/Whistle
Issued 24 March 2005 Resolved
Repair horn prior to operation of vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2005
Resolution: Completed.
Fire Fighting › Fire Bucket › Availability
Issued 24 March 2005 Resolved
Place 3 fire buckets min 2 1/2 gallons with lanyard, labelled "Fire Bucket".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2005
Resolution: Completed.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 March 2005 Resolved
Place Emergency Broadcast Placard at VHF radio installation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2005
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 March 2005 Resolved
Repair Port Mid and Aft Bulge Alarm Visual Alarms
Condition: Improper/Lack of Maintenance
Due 24 April 2005
Resolved 28 March 2005
Resolution: Completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 March 2005 Resolved
Place two flashlights onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2005
Resolution: Completed.
Documentation › Certificates/Documents
Issued 17 March 2003 Resolved
Master without FCC marine operators permit in non-adherence with 47 CFR 80.
Due 17 April 2003
Resolved 23 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 March 2003 Resolved
Vessel's deckhands unfamiliar with Employee Assistance Plan (EAP) mandated under 46 CFR 16. Company shall provide information to employees regarding the EAP.
Due 31 March 2003
Resolved 20 May 2003
Lifesaving
Issued 17 March 2003 Resolved
Stowage of lifefloats, designed to "float-free" should the vessel sink or capsize, was improper and in non-adherence with 46 CFR 180 in that they were tied to the vessel. The lifefloats shall remain untied at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2003
Documentation › Certificates/Documents
Issued 17 March 2003 Resolved
Monthly test of EPIRB not documented in non-adherence with 46 CFR 185.
Due 17 March 2003
Resolved 20 May 2003
Communications
Issued 17 March 2003 Resolved
Emergency broadcasting placard not posted at the radio in non-adherence with 46 CFR 184.
Due 31 March 2003
Resolved 20 May 2003
Navigation
Issued 17 March 2003 Resolved
Chart and navigation publication not corrected to date in non-adherence with 46 CFR 184.
Due 24 March 2003
Resolved 2 July 2003
Fire Fighting
Issued 17 March 2003 Resolved
Portable fire extinguishers not annually serviced in non-adherence with 46 CFR 181 and NFPA 10.
Due 17 April 2003
Resolved 17 March 2003
Electrical
Issued 17 March 2003 Resolved
Dead-ended wiring in the electrical panel box in non-adherence with 46 CFR 183.
Due 31 March 2003
Resolved 27 May 2003
Electrical
Issued 17 March 2003 Resolved
Electrical panel box used to stow materials, e.g. two light bulbs, creating increased risk of shock hazard in non-adherence with 46 CFR 183.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2003
Operations/Management
Issued 17 March 2003 Resolved
Vessel without extra fuses for VHF radio, creating increased risk of inability to communicate during an emergency situation. Vessel shall maintain at least one extra fuse of appropriate capacity for the VHF radio.
Due 24 March 2003
Resolved 27 May 2003
Electrical
Issued 17 March 2003 Resolved
At operating station there are temporary wiring connections in non-adherence with 46 CFR 183. The temporary wiring connections shall be replace with permanent connections.
Due 31 March 2003
Resolved 20 May 2003
Personnel
Issued 17 March 2003 Resolved
Crew unable to perform duties required of them in non-adherence with NVIC 1-91.
Due 31 March 2003
Resolved 20 May 2003
Electrical
Issued 17 March 2003 Resolved
Port side aft main cabin light fixture w/ safety cover replaced w/one w/o safety cover in non-adherence w/ previous CG approval under 46 CFR 175-176. UL approved fixture or fixture w/other recognized approval shall be installed. Light must have safety cover & have same electrical load as original
Due 31 March 2003
Resolved 2 July 2003
Electrical
Issued 11 June 2002 Resolved
Starboard engine bonding wire parted due to corrosion in non-adherence with 46 CFR 183.370 and 183.200. Required to be corrected during current drydocking.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Construction/Loadline › Hull
Issued 11 June 2002 Resolved
Port hanger beam delaminated in non-adherence with 46 CFR 177.100. Required to be corrected during present drydocking. LEGACY COMPONENT DESC: Hanger Beam
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Engineering › Bilge Water Management System
Issued 11 June 2002 Resolved
Mid stbd and aft port bilge high level alarm not operable in non-adherence with 46 CFR 182.530. LEGACY COMPONENT DESC: High level alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Construction/Loadline › Structures
Issued 11 June 2002 Resolved
Mast light mounting bracket deteriorated. Repair/replacement required prior to completion of drydock. LEGACY COMPONENT DESC: Mast light mounting bracket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Construction/Loadline › Structures
Issued 11 June 2002 Resolved
Stern light bracket deteriorated. Repair/replacement required prior to completion of drydock. LEGACY COMPONENT DESC: Stern light bracket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Electrical › Electrical Distribution System (service)
Issued 11 June 2002 Resolved
Deadended wiring located in way of wheel house creating increased potential for electrical shock hazard. Must be removed not later than the completion of the drydock. LEGACY COMPONENT DESC: Deadended wiring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Construction/Loadline › Structures
Issued 11 June 2002 Resolved
5th step from bottom on stairway to upper deck deteriorated. Repair/replacement required by completion of drydock. LEGACY COMPONENT DESC: Stairway to upper deck
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Electrical › Lighting (service)
Issued 11 June 2002 Resolved
Port and stbd aft overhead light covers loose. Repair/replacement required not later than 05 Aug 02. Until satisfactory repairs affected light circuits shall be de-energized and particular care given to the safety of passengers embarking/debarking at night. LEGACY COMPONENT DESC: Water-tight cover
Condition: Improper/Lack of Maintenance
Due 5 August 2002
Resolved 20 May 2003
Construction/Loadline › Structures
Issued 11 June 2002 Resolved
Port and stbd tank supprt brackets rotted. Repair/replacement required by completion of drydock. LEGACY COMPONENT DESC: Tank support bracket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Construction/Loadline › Hull
Issued 11 June 2002 Resolved
Port aft transverse frame fractured. Repair/replacement required prior to completion of drydock. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2002
Unknown
Issued 15 February 2001 Resolved
Provide documentation of 60 minute supervisory training for all licensed captains in the company.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Unknown
Issued 15 February 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Lifesaving
Issued 15 February 2001 Resolved
Attach lanyards to the life float oars and affix to each life float.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Construction/Loadline
Issued 15 February 2001 Resolved
Provide a portable bilge pump for the vessel.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Lifesaving
Issued 15 February 2001 Resolved
Affix lanyards to the life float waterlights and attach to each life float.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Engineering
Issued 15 February 2001 Resolved
Install a 30x30 mesh flame screen on the stbd fuel tank vent line.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Construction/Loadline
Issued 1 March 2000 Resolved
Install retaining devices on the watertight hatch covers for the port and stbd aft compartments.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Lifesaving
Issued 1 March 2000 Resolved
Log quarterly man-overboard and firefighting drills.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Construction/Loadline
Issued 1 March 2000 Resolved
Install mesh strainer covers on the port and stbd aft compartment bilge suction lines.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Accommodation/Occupational Safety
Issued 1 March 2000 Resolved
Install 30x30 wire mesh flame screen on the sewage tank vent discharge.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Construction/Loadline
Issued 1 March 2000 Resolved
Make permanent repairs to the forward most lightening hole(transverse frame) in the stbd aft compartment.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Construction/Loadline
Issued 1 March 2000 Resolved
Label all high level bilge alarms.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Construction/Loadline
Issued 1 March 2000 Resolved
Make watertight the fwd bulkhead in the stbd aft compartment.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Lifesaving
Issued 2 March 1999 Resolved
PROVIDE WATERTIGHT CONTAINER WITH PROPER MARKINGS FOR DISTRESS SIGNALS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 2 March 1999 Resolved
PROVIDE AND POST VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 2 March 1999 Resolved
LOG MAN OVERBOARD AND FIREFIGHTING DRILLS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
UPDATE FIRST AID KIT TO INCLUDE ALL ITEMS LISTED IN 121.710/184.710.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Navigation
Issued 2 March 1999 Resolved
PLACE ON BOARD ADEQUATE CHARTS AND PUBLICATIONS AS PER 46 CFR 184.420.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 2 March 1999 Resolved
CLEARLY MARK FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.