Records from 2016 to 2026. Most recent: inspection, 10 April 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 19.0 ft × 7.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBELLE CHASSE MAR TRANSP · BOURG LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
10 April 2026
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314663
10 April 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8109647
28 May 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7903381
31 July 2023
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7739626
11 April 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7655028
19 April 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7415462
19 April 2021
Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7170378
9 September 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7043848
24 September 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6807931
16 July 2018
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6473377
19 September 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6269181
14 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6209150
19 December 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6060191
24 June 2016
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5910360
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2025
Resolved
Valves and controls must be of an approved type and protected from damage or accidental release/activation. A pull cable used to activate the system controls must be enclosed in conduit.
MI observed pull cable conduit detached from bulkhead. Vessel must have third party technician attend vessel to repair and reviewed by MI prior to movement. 46CFR181.410(b)(5).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2025
Resolution: Verified proper repair of pull cable conduit and SOTEC service report.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2025
Resolved
Medical certificates issued to all other mariners will be issued for a maximum period of 5 years.
MI observed one master's medical certificate expired in 2023.
46 CFR 10.301(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2025
Resolution: Vessel master provided photographic proof of valid medical certificate (exp: 14SEP29).
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 April 2022
Resolved
46 CFR 182.20-25(3)(ii): An opening fitted with threaded plug or cap may be used on the bottom of the tank for tank cleaning purposes. MI found a valve threaded at the bottom of the tank. Remove valve and install a plug only at the opening.
Action required: 705 - Other - as specified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Received pictures with the removal of the valve and plug in place.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 April 2022
Resolved
46 CFR 176.302: The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible. MI found the second page of the posted COI to be the temporary copy and not the final draft. Post the second page of the final draft.
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 19 April 2022
Resolution: Vessel Rep found and mounted draft COI on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 April 2022
Resolved
46 CFR 176.25-5(a)(1): Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. MI found a crack in the FWD fuel tank mount on the STBD side. Make repairs to ensure proper tank placement.
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 19 April 2022
Resolution: Vessel rep provided sufficient photo evidence to satisfy repairs made to the frame crack.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 April 2022
Resolved
46 CFR 176.25-25(a): At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be corrected. MI found the cylinder maintenance overdue. Schedule Annual maintenance and provide proof of service.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: Vessel rep provided service report for the conducted Annual maintenance.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 19 April 2021
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Penetrations and openings in watertight bulkheads must-Have means to make them watertight. Marine Inspectors identified 1" round crack in bulkhead where the deck meets the STBD hull, between the Engine Room and Forward compartment. Vessel will return the bulkhead to watertight integrity.
"Old T" 46 CFR 177.13-1 & 46 CFR 171.114(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 19 April 2021
Resolution: Received and reviewed photographic evidence of repairs and satisfactory dye penetrant test for the crack identified in the bulkhead between the Forward Compartment and Engine Room.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 April 2021
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of the vessel. Marine Inspectors identified pinhole hull breach permitting an ingress of water at the vicinity of the STBD rudder post. Vessel operator must return watertight integrity to the steering compartment and provide evidence of sufficient repairs to Marine Inspectors.
"Old T" 46 CFR 177.10-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2021
Resolved 19 April 2021
Resolution: Received, reviewed and accepted photographic evidence of satisfactory repair to the hull breach identified in the steering compartment. Photographs attached to this activity.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 April 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Marine Inspectors identified that fuel tank shutoff valve reach rod had disconnected from the valve. Crew re-connected reach rod to fuel shutoff valve.
"Old T" 46 CFR 182.20-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 April 2021
Resolved 19 April 2021
Resolution: Observed crew re-connecting fuel shutoff valve to reach rod and test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Marine Inspectors identified chaffed and bare wires in vessel engine room. Crew replaced improper wiring in the Engine Room.
"Old T" 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 April 2021
Resolved 19 April 2021
Resolution: Observed vessel crew replacing improper wiring in Engine Room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2018
Resolved
02 lifejackets unserviceable
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 July 2018