MAURY USCG vessel records Sign in
← All vessels

THE BEACH

THE BEACH is a 1995 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1995, most recently in February 2026, along with 170 deficiencies, 1 operational control and 3 casualty investigations between 2004 and 2008.

Records from 1995 to 2026. Most recent: inspection, 10 February 2026.

Built
1995
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8958
424077
Flag
UNITED STATES
367471370 (licence lapsed)
Maury page id
psix-424077

Inspections, by type

…with no type recorded17
Years with a record 28 calendar years (1995–2026)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.3 ft × 12.5 ft × 6.6 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUSTOM DIVE BOATS INC · DELAND, FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portKEWALO BASIN, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8958MMSI 367471370 · expired · compulsorily equipped · granted 29 June 2016, cancelled 1 August 2026
WDF6168MMSI 367471370 · cancelled · compulsorily equipped · granted 13 November 2010, cancelled 27 June 2016
WCZ9408MMSI not assigned · expired · compulsorily equipped · granted 14 July 2000, cancelled 18 September 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

10 February 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8298985
4 September 2025 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8113059
14 February 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8082805
29 November 2023 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7801975
6 September 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7734218
18 January 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7601348
1 February 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7389297
29 October 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7342219
21 September 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7316606
8 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7137754
4 February 2020 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6902703
26 September 2019 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6821315
19 April 2019 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6665879
3 December 2018 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6585092
16 July 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6481641
18 April 2018 Annual Inspection · Plan Review "T" Boat · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6394403
13 September 2017 Drydock Exam · In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6267529
13 March 2017 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6102756
14 October 2016 Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6024414
5 July 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5932072
6 May 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5915907
17 January 2012 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4226306
10 August 2011 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 4117403
28 February 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4009918
15 February 2011 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3946173
15 October 2010 Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3870623
27 July 2009 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3545438
25 February 2009 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3422639
9 December 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3401101
8 August 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3292775
12 September 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3066888
6 March 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2858845
11 May 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2619789
16 August 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2468124
24 March 2005 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2318718
23 February 2005 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2291045
13 November 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2243232
23 June 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2044983
15 April 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2044996
31 January 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1999871
17 July 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1846266
10 June 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1814057
20 June 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1622204
16 February 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1487143
11 February 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1485571
10 January 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1478901
10 July 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 706637
9 July 2001 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408793
6 July 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 725344
21 June 2001 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 1523506
6 June 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1070611
31 May 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391608
30 May 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1066591
25 May 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 212455
25 May 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 213043
25 May 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454954
16 August 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822364
5 July 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1051948
3 July 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379152
28 June 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417084
7 March 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815608
7 September 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 784255
15 June 1999 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360960
27 May 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 806702
24 July 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 794761
28 May 1998 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411701
16 October 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 776037
26 July 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371926
2 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1109166
10 May 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364254
17 September 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 111061
24 July 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416343
14 June 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357649
20 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 43953
25 March 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1083456
1 January 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 176801
29 September 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1192693
27 May 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357200
12 May 1995 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1173123

Deficiency record · 170

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 February 2026 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Installed (Fwd, Mid, and Aft) bilge pumps did not give any indication of operation from the control station. Repair to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 17 February 2026
Resolution: Bilge alarms repaired to the satisfaction of the marine inspector. Operation of bilge alarms in each space rendered adequate visual alarm(s) at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2026 Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018. 20 life jackets had retro reflective material reapplied that did not cover the entire area life jackets were originally fitted with. Install new retro reflective material to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 24 February 2026
Resolution: O/O replaced retroreflective tape on 20 life jackets as required by the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jackets stowed in forward compartment lacked any indication of stowage location. Conspicuously mark/identify location of life jacket stowage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2026
Resolved 9 March 2026
Resolution: Received photo showing adequate labeling of the location of lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 February 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Wire found disconnected from fog horn at operating station. Secure or remove disconnected wire from fog horn to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 9 March 2026
Resolution: O/O secured stray/loose fog horn electrical installation.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 February 2026 Resolved
Independent fuel tanks must be located and installed as described: all fuel tanks must be electrically bonded to a common ground. Fuel tank bonding wire was disconnected. Secure fuel tank bonding wire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 19 February 2026
Resolution: O/O secured fuel tank ground/bonding wire. See photo titled "fuel tank ground" in deficiency document tab.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 February 2026 Resolved
A vessel must carry a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10). The required 48 doses of analgesic medication was found expired. Replace 48 doses of analgesic medication on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 17 February 2026
Resolution: O/O replaced doses of Aspirin onboard with new 100-count bottle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2026 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI... The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Fire buckets on board were not stenciled as such, and one of the three did not have an attached lanyard. Stencil "FIRE BUCKET" on each bucket, and attach a lanyard to the bucket missing one to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 9 March 2026
Resolution: Fire buckets were appropriately stenciled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 February 2025 Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. FCC Safety Radiotelephony Certificate was expired. 47 CFR 80.901
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2025
Resolved 5 March 2025
Resolution: Owner sent a copy of the new FCC safety cert
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 February 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not posted at the operating station. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2025
Resolved 5 March 2025
Resolution: Owner sent photo of Emergency instructions posted.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. The aft framing of the swim step had a large section of pitting and cracking. Submit repair proposal to the satisfaction of the attending Marine Inspector prior to credit drydock. 46 CFR 177.10-1(a) Old T
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: Aft section cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. There are areas of possible water intrusion into the fiberglass on the hull below the waterline. Clean and remove paint to make ready for re-inspection prior to credit drydock. 46 CFR 177.10-1(a) Old T
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: No water intrusion found. Area repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. There are areas of damage,cracking, and previous repair around the exterior of the hull above the waterline. Clean and remove paint on the identified areas to make ready for re-inspection prior to credit drydock. 46 CFR 177.10-1(a) Old T
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: Areas repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. The transom around the starboard jet has delamination on the interior and exterior of the hull. Repair as original prior to credit drydock. 46 CFR 177.10-1(a) Old T
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: Area repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. Port and starboard midship vent compartments have holes through the bulkhead. Close or seal holes to the satisfaction of the attending Marine Inspector prior to credit drydock. 46 CFR 177.10-1(a) Old T
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: Port side holed glassed over and starboard fitting replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 September 2023 Resolved
Each watertight bulkhead must be watertight. The gasket on the watertight hatch leading to the watertight bow space needs to be replaced. Replace the gasket on the watertight hatch. 46 CFR 179.320(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: Gasket replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2023 Resolved
A vessel must comply with the structural design requirements. Areas of the port side rub rail from the midship boarding area and aft are damaged. Replace in kind. 46 CFR 177.10-1(a) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: Area repaired in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2023 Resolved
Propulsion machinery must be suitable for in type for the propulsion requirements of the hull. The starboard main propulsion engine was not able to be started. Prove proper operation of the starboard main propulsion engine. 46 CFR 182.200
Action required: 10 - Deficiency Rectified
Resolved 18 January 2023
Resolution: Captain started and proved proper operation of the engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2023 Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrical hazards, including fire and electrical shock. Three dead ended wires are present in the helm console. Provide an immediate temporary repair of wire nuts and electrical tape on each wire end. Provide a proper repair by removing the dead end cables or properly terminating them. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 25 January 2023
Resolution: The identified dead-end cables were terminated.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 January 2023 Resolved
A visual indicator must be provided at the operating station to indicated when any automatic bilge pump is operating. The #3 automatic bilge pump visual indicator is inoperable. Prove proper operation of the required visual indicator. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 25 January 2023
Resolution: Automatic bilge pump visual indicator was repaired and operational.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 January 2023 Resolved
A vessel must carry an approved first aid kit or a first aid kit with equivalent contents and instructions. The required eye wash and aspirin was expired. Provide a first aid kit with equivalent contents as one approved under 46 CFR 160.041. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 25 January 2023
Resolution: All expired components of the first aid kit were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 January 2023 Resolved
Equipment and materials not covered by standards in this subchapter may be inspected in accordance with the standards acceptable to the OCMI as good marine practice. The vessel is equipped with an AED as part of the OCMI's requirement for reduced manning during diving operations. The AED pads are expired. The Captain is required to ensure the vessel is properly manned in accordance with the COI until the provisions of WI-31 can be fulfilled. Provide new AED pads.
Action required: 705 - Other - as specified
Due 1 February 2023
Resolved 25 January 2023
Resolution: New AED pads provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 February 2022 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. EPIRB battery was past its expiration date. Vessel restricted to operate only on Lakes, Bays, and Sounds route. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 February 2022
Resolution: Vessel received a new battery for EPIRB AND submitted a ACR test verification report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2022 Resolved
The Certificate of Inspection issued to a vessel describes the vessels minimum manning requirements and any equivalences accepted or authorized by the cognizant OCMI. Vessel does not have an adequate medical oxygen IAW Work Instruction 31. Vessel restricted from having the required deckhands enter the water until provisions of Work Instruction 31 are met. 46 CFR 176.103
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 February 2022
Resolution: Vessel purchased oxygen from Airgas and provided a receipt.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 February 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel requires Certificate of Documentation with updated owner information. 46 CFR 67.313(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2022
Resolved 21 March 2022
Resolution: Received COD from the NVDC submitted picture proof located in documents
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 February 2022 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel shall update Safety Radiotelephony Certificate with current owner. 47 CFR 80.13(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2022
Resolution: Vessel submitted updated FCC certification for radio station authorization
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2021 Resolved
The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Vessel has three electric bilge pumps installed that do not meet UL 1113 requirements. Replace fore peak, tank space, and forward engine room electric bilge pumps and demonstrate operational test to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 9 February 2021
Resolution: Attending MI sighted manufactures UL certification on pumps pacakaging. Owner operationally tested bilge pumps in the presence of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2021 Resolved
All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Install new 15 amp switches and fuses for electric submersible pumps/float switches and a 1 amp fuse for the two high water alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 9 February 2021
Resolution: Owner purchased correct size switches and fuses. MI verified installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2021 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Install protective marine style battery terminal adapter boot covers to the starboard main engine battery positive and negative terminals.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 9 February 2021
Resolution: Owner purchased and installed correct covers. Attending MI sighted covers installed on stbd battery terminals and both MDE's starter solenoid battery cable terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 February 2021 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Install ammeter or remove battery charger. Additionally, properly terminate electrical connections associated with this system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 9 February 2021
Resolution: Owner removed battery charger and attending MI sighted its removal.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2021 Resolved
Covered metal trash containers shall be provided in lounge areas and the spaces shall be maintained to minimize fire and safety hazards and to preserve sanitary conditions. Operator removed plastic trash container found on board. 46 CFR 177.30-7(d)
Action required: 10 - Deficiency Rectified
Due 8 February 2021
Resolved 8 February 2021
Resolution: Owner removed plastic trash container from vessel in the presence of the attending MI.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 February 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels EPIRP installed under canopy, inhibiting float free arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2020
Resolution: EPIRB moved to allow float free arrangement
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2020 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stern light inoperable.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2020
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 February 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2020
Resolution: New radio purchased with internal GPS for DSC operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy is worn and grab line unservicable. Replace life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2020
Resolution: New lifebuoy purchased
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 February 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge alarms not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 February 2020
Resolution: Bilge alarms labled
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 March 2017 Resolved
Replace or repair inoperable audible bilge alarm at the operating station for the center compartment (fuel tank compartment) bilge float switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 21 March 2017
Resolution: Audible bilge alarm at the operating station is working properly.
Navigation › Piloting/Steering › Marine Charts
Issued 13 March 2017 Resolved
Provide current (2017) navigation chart, tide table, coast pilot, and Coast Guard light list for the vessel's operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 21 March 2017
Resolution: New charts and pubs for operating area onboard.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 13 March 2017 Resolved
Seal bulkhead penetrations on the forward bulkhead in the engine room to ensure the engine room space is vapor tight for use of the fire extinguishing agent (FM 200) installed in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 21 March 2017
Resolution: Penetrations in the forward engine room bulkhead confirmed to be vapor tight using previously approved expansion foam.
Stability › Watertight Integrity › Coaming
Issued 8 July 2016 Resolved
Repair coaming for cockpit hatch, and replace hatch gasket. Ensure hatch and coaming are weathertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 October 2016
Resolution: Verified coaming and gasket for cockpit hatch was repaired. All sat
Stability › Watertight Integrity › General
Issued 8 July 2016 Resolved
Replace/Repair gaskets for engine room access hatches. Ensure channel surrounding hatches drains overboard and not into the bilge, and repair any holes that would allow water to drain past the hatches and into the engine room. Both hatches must be watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 October 2016
Resolution: Verified gaskets were replaced for engine room hatches and holes in the channels surrounding hatches were repaired. All sat.
Stability › Watertight Integrity › General
Issued 8 July 2016 Resolved
Submit plans to modify engine room ventilation arrangement. Ventilation must meet requirements of 46CFR 182.465 (a) and (c) thru (h).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 17 October 2016
Resolution: Verified installation of new vents were IAW plans submitted to the office and approved on Aug 24 2016. All sat.
Stability › Watertight Integrity › General
Issued 8 July 2016 Resolved
Ensure ventilation arrangements for other spaces are designed to preserve the watertight integrity of the well deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 October 2016
Resolution: Verified new ventilation arrangements preserve the watertight integrity of the deck and have means for closing off vent openings. All sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 July 2016 Resolved
Remove engine room bilge pump discharge hose from engine room ventilation opening so that fire damper will close properly; relocate bilge pump through-hull fitting below main deck and in the engine room space so that discharge hose doesn't burn through and compromise vapor tight boundary during a fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 October 2016
Resolution: Ensured engine room bilge discharge hose no longer interferes with fire damper closing and that the discharge line is fitted with means to keep the integrity of the vapor tight boundary during a fire.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 January 2012 Resolved
Mount donning placars for both child and adult life jackets
Due 17 February 2012
Resolved 25 January 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 January 2012 Resolved
Provide complete first aid kit IAW 46 CFR 160.041
Due 17 February 2012
Resolved 25 January 2012
Communications › Radio Communications › VHF Radiotelephone
Issued 17 January 2012 Resolved
Provide and mount emergency broadcast placard at operating station IAW 46 CFR 184.506.
Due 17 February 2012
Resolved 25 January 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 January 2012 Resolved
Remove all dead end wiring and electrical installations at operating station.
Due 17 February 2012
Resolved 25 January 2012
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 17 January 2012 Resolved
Provide proof of Consortium Enrollment and covered employees list.
Due 1 February 2012
Resolved 17 January 2012
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 15 February 2011 Resolved
Renew fitting for starboard fuel filter discharge.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 15 February 2011
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2011 Resolved
Properly repair FRP delaminating in front of collision bulkhead.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 13 May 2011
Construction/Loadline › Structures › Deck Plating
Issued 15 February 2011 Resolved
Properly finish repairs on V deck and make available for inspection.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 13 May 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 October 2010 Resolved
Replace expired items in first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 18 October 2010 Resolved
Provide proof of servicing fixed fire system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2010
Fire Fighting › Fire Bucket › Availability
Issued 18 October 2010 Resolved
Provide one additional 2.5 gallon firebucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Lifesaving › Lifebuoys › Serviceable
Issued 18 October 2010 Resolved
Replace ring buoy and 60 ft line with buoyant synthetic dark line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 18 October 2010 Resolved
Provide additional B-II portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 October 2010 Resolved
Renew retro tape on child PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Engineering › Bilge Water Management System › Not Installed
Issued 18 October 2010 Resolved
Prove proper operation and installation of bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 October 2010 Resolved
Renew missing bracket for machinery guard on starboard engine.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Engineering › Fuel Oil Service System › Hose
Issued 18 October 2010 Resolved
Provide double hose clamps on starboard fuel supply line.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Stability › Water on Deck › General
Issued 18 October 2010 Resolved
Renew starboard hatch inner coaming to make watertight.
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 15 December 2010
Engineering › Bilge Water Management System › Not Operational
Issued 18 October 2010 Resolved
Repair and prove proper operation of lazarette bilge pump.
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 15 December 2010
Engineering › Fuel Oil Service System › Hose
Issued 18 October 2010 Resolved
Remove extrra fuel hose not being used.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Documentation › Certificates/Documents › FCC SSL
Issued 18 October 2010 Resolved
Provide FCC ships station license.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 18 October 2010 Resolved
Provide FCC Marine Radio Operator Permit for all Masters.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 October 2010 Resolved
Provide monthly EPIRB test log.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Engineering › Fuel Oil Service System › Pump
Issued 18 October 2010 Resolved
Properly support fuel pump in overhead and fuel lines, repair leak in overhead valves.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Electrical › Electric Supply System (service) › Cable
Issued 18 October 2010 Resolved
Replace all twist on connectors with crimped fittings if not installed in a junction box - (in engine room and accomodation space overhead).
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 18 October 2010 Resolved
Renew cathodic protection and ground wires.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Stability › Water on Deck › General
Issued 18 October 2010 Resolved
Reinstall lock mechanism on engine hatches.
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 15 December 2010
Engineering › Bilge Water Management System › Not Installed
Issued 18 October 2010 Resolved
Provide visual indicator to show operation of all automatic bilge pumps at operating station.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 October 2010 Resolved
Vessel must complete satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2010
Stability › Watertight Integrity › General
Issued 27 July 2009 Resolved
Post COI & Stability letters in area visable to PAX.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Posted COI & Stability letters in area visable to PAX.
Personnel › Training › First Aid/CPR
Issued 27 July 2009 Resolved
Provide copies of CPR cards for 50% of crew & Marine Operator Permit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Provided copies of CPR cards for 50% of crew & Marine Operator Permit.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 27 July 2009 Resolved
STBD F/O Water Separator remove water & identify problem. Make repairs as needed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: STBD F/O Water Separator removed water & identify problem. According to the owner the containers the fuel was delivered in were not tight (allowing water to leak in).
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 27 July 2009 Resolved
STBD Jet Drive bottom flange leaks monitor & conduct repairs at next dry-dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 25 February 2011
Resolution: STBD jet drive bottom flange was repaired and sealed. U/W tested proved no further leakage.
Navigation › Piloting/Steering › Marine Charts
Issued 27 July 2009 Resolved
Update all Nav Charts & Pubs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Updated all Nav Charts & Pubs.
Lifesaving › Hand Flares › Expired
Issued 27 July 2009 Resolved
Provide six red hand flares prior to carrying PAX.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2009
Resolved 28 July 2009
Resolution: Provided six red flares.
Lifesaving › Lifefloat › Serviceable
Issued 27 July 2009 Resolved
Provide proof of strength rating for life float weak-link.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Provided proof of strength rating for life float weak-link.
Lifesaving › Lifefloat › Float Free
Issued 27 July 2009 Resolved
Make life float cover easily removable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 19 November 2009
Resolution: Examined to the satisfaction of attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 July 2009 Resolved
Replace ring buoy & lifefloat light batteries.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Replaced battery.
Lifesaving › Lifebuoys › Serviceable
Issued 27 July 2009 Resolved
Make repairs to ring buoy & lifefloat with approved [name withheld] repair kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Made repairs to ring buoy & lifefloat with approved [name withheld] repair kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 July 2009 Resolved
Reattach wires & lighting in accomadation space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 27 August 2009
Resolution: Reattached wires & lighting in accomadation space.
Engineering › Bilge Water Management System › Pump
Issued 27 July 2009 Resolved
Prove proper operation of bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 19 November 2009
Resolution: Operation of bilge pump proved to the satisfaction of attending marine inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 27 July 2009 Resolved
Prove proper operation of STBD engine prior to caring PAX.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2009
Resolved 28 July 2009
Resolution: Proved proper operation of STBD engine prior to caring PAX.
Construction/Loadline › Hull › Bracket
Issued 25 February 2009 Resolved
Add additional bolt to port side swim step platform.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Provided additional bolt to port side swim step.
Construction/Loadline › Hull › Weld
Issued 25 February 2009 Resolved
Repair weld to port side attachment point of swim platform.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made satisfactory weld repairs to weld on port side attachment point of swim platform.
Construction/Loadline › Structures › Deck Plating
Issued 25 February 2009 Resolved
Grind down and make repairs to aft deck.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made satisfactory FRP repairs to aft deck.
Construction/Loadline › Structures › Deck Plating
Issued 25 February 2009 Resolved
Grind down and repair fiberglass under port and stbd benches.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made proper repairs to port and stbd benches.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 February 2009 Resolved
Remove unused sewage pipe in fuel tank space.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Removed unused sewage pipe.
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 February 2009 Resolved
Fix leak to aft potable water tank.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Replaced cracked pipe which secured the leak.
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2009 Resolved
Repair fiberglass on port side of fuel tank space.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made proper repairs to FRP in fuel tank space.
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2009 Resolved
Grind and repair fiberglass on port side of engine compartment.
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made proper repair to FRP on port side of engine compartment.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 February 2009 Resolved
Make forward bulkhead of engine compartment vent tight (fuel supply and return lines).
Due 27 March 2009
Resolved 11 March 2009
Resolution: Made fwd blhd of engine compartment vent tight.
Construction/Loadline › Hull › Side Shell
Issued 8 August 2008 Resolved
Make repairs to delaminated fiberglass on port side amidships joint between side shell and deck.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Made proper repairs to port side delaminated fiberglass.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 August 2008 Resolved
Provide retro for 6 identified lifejackets.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided retro for 6 identified lifejackets.
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 August 2008 Resolved
Provide new retro for life float.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided new retro for lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 8 August 2008 Resolved
Provide 2 serviceable paddles for lifefloat.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided 2 new paddles for lifefloat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 August 2008 Resolved
Provide current training log.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided current training log.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 August 2008 Resolved
Provide a current lifesaving maintenance log.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Current lifesaving maintenance log is onboard vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 August 2008 Resolved
Remove dead-end wires throughout vessel.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Dead-end wires have been removed throughout the vessel.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 August 2008 Resolved
Provide metal support hangers for electrical wiring spaced every 24 inches.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 26 August 2008
Resolution: Metal supports hangers provided throughout vessel.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 August 2008 Resolved
Provide proof vessel has been fumigated for pest infestation.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Vessel has been fumigated as required.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 8 August 2008 Resolved
Renew anchor chain due to corrosion.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided new anchor chain.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 August 2008 Resolved
Prove proper operation of your fuel compartment bilge pump.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Proved proper operation of the fuel compartment bilge pump.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 8 August 2008 Resolved
Provide proof of EAP training for supervisors and crew, SAP information and post current hotline and EAP information.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Provided proof of crew and supervisor training, SAP info and posted necessary information.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 August 2008 Resolved
Provide proof of enrollment with Consortium.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Vessel rep provided proof of enrollment with Consortium.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 August 2008 Resolved
Provide list of covered employees.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Vessel rep provided list of employees enrolled with the Consortium.
Documentation › Certificates/Documents › FCC SSL
Issued 8 August 2008 Resolved
Provide valid FCC safety radio certificate.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 25 August 2008
Resolution: Received a copy of FCC Safety Radio Certificate fax into the office
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 August 2008 Resolved
Provide a new lanyard for water light on life float. Lanyard should be dark in color or UV resistant and 18ft in length attached around the body of the life float. Life float shall be mounted in a float free arrangement.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 28 August 2008
Resolution: All necessary corrections made to life float, life float connections, and the float light.
Construction/Loadline › Hull › Weld
Issued 8 August 2008 Resolved
Make repairs to welds of aft ladder at the pivot points.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 2 September 2008
Resolution: Made necessary repairs to the welds of the aft ladder at the pivot points.
Lifesaving › Lifebuoys › Serviceable
Issued 12 September 2007 Resolved
Replace worn out ring buoy
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 26 September 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 September 2007 Resolved
Replace inoperable light on lifefloat,.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 26 September 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2007 Resolved
Replace suction hoses for main engine cooling hoses.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 26 September 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 August 2005 Resolved
Provide ground wire for fuel tank fill hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 11 May 2006
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 16 August 2005 Resolved
Provide caps/plugs for fuel filter drains.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2005
Resolved 11 May 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 June 2004 Resolved
Provide current editions of current and tidal tables, navigation charts, and coast pilot for operating area IAW 46 CFR 184.420.
Due 23 July 2004
Resolved 12 July 2004
Engineering › Bilge Water Management System › Eductor
Issued 23 June 2004 Resolved
Provide screen for bilge intake IAW 46 CFR 182.510.
Due 23 July 2004
Resolved 24 July 2004
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 June 2004 Resolved
Provide proof that chemical testing program is in compliance with 46 CFR 16.
Due 23 July 2004
Resolved 12 July 2004
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 June 2004 Resolved
Provide donning placard for child size TYPE I lifejackets IAW 46 CFR 185.516.
Due 23 July 2004
Resolved 12 July 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 23 June 2004 Resolved
Provide means of securing ventilation in engine room IAW 46 CFR 182.465(h).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2004
Resolution: Ventilation pull cables repaired to working condition.
Engineering › Bilge Water Management System › Not Operational
Issued 23 June 2004 Resolved
Prove proper operation of bilge high level audible and visible alarms IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2004
Resolution: New audible and visible alarm system installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2003 Resolved
Install visual indicator for Engine room bilge high water alarm IAW 46CFR182.530. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Due 17 August 2003
Resolved 23 July 2004
Documentation › Certificates/Documents
Issued 20 June 2002 Resolved
Provide FCC Marine Radio Operators Permit in accordance with 46 CFR 184.502. LEGACY COMPONENT DESC: FCC Marine Radio Operators Permit
Condition: Unknown
Due 27 June 2002
Resolved 11 June 2003
Engineering › Sea-water System (primary cooling)
Issued 20 June 2002 Resolved
Replace salt water suction hose between the engine and the sea strainer on the port engine in accordance with 46 CFR 176.800 and J1492. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 27 June 2002
Resolved 11 June 2003
Lifesaving › Buoyant Apparatus
Issued 20 June 2002 Resolved
Replace sea painter on lifefloat in accordance with 46 CFR 180.137. LEGACY COMPONENT DESC: Lifefloat sea painter
Condition: Unknown
Due 27 June 2002
Resolved 11 June 2003
Lifesaving › Lifebuoys
Issued 20 June 2002 Resolved
Replace/repair water light for lifebuoy in accordance with 46 CFR 180.70. Vessel is restricted to day light operation only until light is repaired/replaced. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 27 June 2002
Resolved 11 June 2003
Documentation
Issued 25 May 2001 Resolved
Provide a valid FCC Marine Radio Operator Permit, in accordance with 46 CFR184.502.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Fire Fighting
Issued 25 May 2001 Resolved
Provide written instructions to master for operation of fixed fire fightingsystem in the event of fire.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 25 May 2001 Resolved
Make ready for inspection, the jet drive system. In accordance with 46 CFR 176.404.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Fire Fighting
Issued 25 May 2001 Resolved
Provide manual operation of fixed fire fighting system to conform to manufactures specifications in accordance with 46 CFR 176.810.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Construction/Loadline
Issued 28 June 2000 Resolved
Repair automatic bilge pump in fuel tank compartment in accordance with 46 CFR 176.804(h). Conduct and log hourly rounds for space while carrying passengers for hire.
Condition: Unknown
Due 5 July 2000
Resolved 20 July 2000
Navigation
Issued 28 June 2000 Resolved
Replace steering nozzle top bearing O-rings on starboard side in accordancewith 46 CFR 182.610.
Condition: Unknown
Due 5 July 2000
Resolved 20 July 2000
Engineering
Issued 28 June 2000 Resolved
Repair area of delamination on starboard fiberglass exhaust pipe, forward of muffler, in area of elbow in accordance with 46 CFR 182.425.
Condition: Unknown
Due 14 July 2000
Resolved 20 July 2000
Navigation
Issued 28 June 2000 Resolved
Remove previous (old and dangling) steering cable from the lazarette in accordance with 46 CFR 176.800.
Condition: Unknown
Due 5 July 2000
Resolved 20 July 2000
Fire Fighting
Issued 28 June 2000 Resolved
Provide proper ventilation closures for engine compartment in accordance with 46 CFR 182.465(h).
Condition: Unknown
Due 5 July 2000
Resolved 20 July 2000
Documentation
Issued 28 June 2000 Resolved
Provide current FCC station license and FCC safety certificate in accordance with 46 CFR 184.502.
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Electrical
Issued 28 June 2000 Resolved
Repair/ replace light fixture in fwd compartment in accordance with 46 CFR 183.410 and 176.800.
Condition: Unknown
Due 14 July 2000
Resolved 20 July 2000
Engineering
Issued 15 June 1999 Resolved
Make the emergency fuel shutoff valve accessible without the need of tools.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 15 June 1999 Resolved
Replace the fixed fire fighting system in the engine room.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Navigation
Issued 15 June 1999 Resolved
Renew all navigation running lights.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 15 June 1999 Resolved
Reroute shower heater hoses that pass through the engine room ventilation to allow vent closure in event of fire.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Deck/Cargo
Issued 15 June 1999 Resolved
Provide a suitable anchor line of adequate length for area of operation.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Engineering
Issued 28 May 1998 Resolved
Replace fuel piping w/ metallic piping or approved flexible non-metallic hose w/ factory assembled end fittings. If you use non-mettalic hose, the hose must meet SAE J-1942 and the end fittings must meet SAE J-1475 or you may prove hose fittings can withstand hydro test to 2x operating pressure.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Fire Fighting
Issued 28 May 1998 Resolved
Prove proper servicing of fixed and portable fire extinguishing system.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 10 May 1997 Resolved
Provide and correctly install a 406 Catagory I EPIRB.
Condition: Unknown
Due 8 July 1997
Resolved 10 July 1997
Lifesaving
Issued 14 June 1996 Resolved
Provide life jacket placards in accordance with IFR 46 CFR 185.516.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Label number of persons capacity on life float in at least 1.5-inch lettersin accordance with IFR 46 CFR 185.604.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Provide water light for life float in accordance with 46 CFR 180.15-5(d).
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
Repair holes in bulkhead between fuel tank compartment and machinery spaces.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Documentation
Issued 14 June 1996 Resolved
Provide documentation of crew training in accordance with IFR 46 CFR 185.420.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Provide documentation of abandon ship and man overboard drills and trainingin accordance with IFR 46 CFR 185.520.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Fire Fighting
Issued 14 June 1996 Resolved
Provide documentation of fire fighting drills and training in accordance with IFR 46 CFR 185.524.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Provide documentation of weekly maintenance and inspection for survival craft in accordance with IFR 46 CFR 185.720.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 27 May 1995 Resolved
Tank space deck support stanchion port side adrift. Properly secure stanchion._x001C_
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Fire Fighting
Issued 27 May 1995 Resolved
Coiled spring hose used as vent ducting in diesel machinery space. Provideproper rigid permanent construction fire proof duct IAW 46CFR182.20-45.
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Documentation
Issued 27 May 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 August 1995
Resolved 27 July 1995
Construction/Loadline
Issued 27 May 1995 Resolved
Engine room forward bulkhead drilled, penetrations not watertight.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Engineering
Issued 27 May 1995 Resolved
Fuel hose used in fuel piping system in excessive lengths. Bring fuel piping system into compliance with 1)46 CFR 182.20-40.(a)(2). i.e. (lengthsnot more than 30 inches) or 46 CFR 182.455 and 182.720 of Small Passenger Vessel Inspection and Certification; Proposed Rule, January 13, 1994.
Condition: Unknown
Due 30 August 1995
Resolved 15 September 1995
Construction/Loadline
Issued 27 May 1995 Resolved
Fixed hand bilge pump suction valve manifold not properly labeled. Providepermanent labels for all bilge suction valves to identify the space served.
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Engineering
Issued 27 May 1995 Resolved
Fuel hose penetrates forward engineroom bulkhead. Bring fuel piping systeminto compliance with 182.20-40 i.e. Flexible fuel hose shall not penetratewatertight bulkheads._x001C_
Condition: Unknown
Due 30 August 1995
Resolved 15 September 1995
Construction/Loadline
Issued 27 May 1995 Resolved
PVC bilge piping and other misc. piping systems temporarily secured with plastic tie wraps. Properly secure piping systems.
Condition: Unknown
Due 30 August 1995
Resolved 15 September 1995
Lifesaving
Issued 27 May 1995 Resolved
Post stability letter and certificates. In accordance with 176.01-40,_x001C_
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Fire Fighting
Issued 27 May 1995 Resolved
Demonstrate proper operation of fixed gas extinguishing system and heat detection system until demonstrated vessel must maintain a total of 4 BII extinguishers on board.
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Fire Fighting
Issued 27 May 1995 Resolved
Portable hand fire pump not in compliance with regulation. Provide "hand operated pump at least 5GPM equipped with a suction and discharge hose for use in fighting a fire". IAW 181.10-5
Condition: Unknown
Due 15 June 1995
Resolved 19 July 1995
Documentation
Issued 12 May 1995 Resolved
PROVIDE AN EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-5. PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Documentation
Issued 12 May 1995 Resolved
PROVIDE A VHF RADIO AND FCC DOCUMENTS IN ACCORDANCE WITH 47 CFR 80.901 PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Navigation
Issued 12 May 1995 Resolved
PROVIDE APPROPRIATE CHARTS AND PUBS, IN ACCORDANCE WITH 46 CFR 185.20-35. PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Documentation
Issued 12 May 1995 Resolved
PROVE OPERATING COMPANY COMPLIANCE WITH DRUG TESTING REGULATIONS IN ACCORDANCE WITH 46 CFR 16. PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Documentation
Issued 12 May 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995

Casualty record · 3

31 January 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1999871
13 November 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2243232
9 December 2008Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 3401101
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.