Records from 1985 to 2003. Most recent: inspection, 25 June 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 68
25 June 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1819709
21 November 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1708923
12 December 2001
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474415
30 November 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384938
23 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076060
29 May 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1066606
12 April 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060608
10 January 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376455
25 February 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 816557
23 February 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395366
3 December 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811580
29 November 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 815129
10 February 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1129485
9 December 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809261
20 November 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805249
11 February 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 775275
22 January 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1114910
11 December 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378232
19 May 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1097229
4 February 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1416436
19 December 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1356013
3 October 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146805
13 September 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148216
11 September 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952743
30 July 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1080022
6 February 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189912
28 November 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883221
19 July 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 877642
14 July 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874242
26 April 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172102
19 April 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166420
13 March 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867026
12 October 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870327
21 April 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1169057
15 November 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137638
31 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 230779
27 September 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842460
24 August 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157702
17 August 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153196
2 July 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155906
24 June 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843780
3 March 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839902
30 September 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954978
12 June 1992
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268240
1 May 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259162
12 March 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957940
5 March 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1314874
20 August 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942679
10 June 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1226194
18 April 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228462
31 January 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907727
19 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1211117
14 March 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905036
3 November 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040290
1 May 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1206163
14 March 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 893614
18 January 1989
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 889873
6 July 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207395
13 May 1988
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1351117
4 May 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1037842
13 May 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1332951
24 March 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324882
9 February 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319774
26 February 1986
Credit Drydock · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1293606
12 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978175
9 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288662
9 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982361
4 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1293654
Construction/Loadline
Issued 30 November 2001
Resolved
Conduct sea trial with Coast Guard Marine Inspector prior to taking passengers for hire.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2001
Resolved 12 December 2001
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 November 2001
Resolved
Conduct sea trial after refloating vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2001
Resolved 12 December 2001
Resolution: Satisfactory sea trial conducted.
Lifesaving
Issued 12 April 2001
Resolved
OFFICE ISSUED CG-835 FOR VESSEL TO NOT CARRY MORE THAN 62 PERSONS WITH ITS CURRENT LIFE FLOAT CAPACITY. VESSEL COI STATES 76 TOTAL PERSONS. OWNER HAS ADDITIONAL LIFEFLOAT ON ORDER AND IS NOT SURE IT WILL ARRIVE BY 11MAR01 DEADLINE.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 10 January 2001
Resolved
CONDUCT U/W DRILLS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Lifesaving
Issued 23 February 2000
Resolved
REPLACE LIFE RING AND ATTACHED LINE.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 23 February 2000
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB. VESSEL IS LIMITED TO ROUTES NOT FURTHER THAN THREE MILES FROM SHORE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Fire Fighting
Issued 23 February 2000
Resolved
MOVE B-II FIRE EXTINGUISHER LOCATED IN THE ENGINE ROOM TO A POINT JUST OUTSIDE THE ENGINE ROOM IAW TABLE 181.500.
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Lifesaving
Issued 29 November 1999
Resolved
CONDUCT UNDERWAY TEST TO ENSURE WATERTIGHT INTERGTITY.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Construction/Loadline
Issued 20 November 1998
Resolved
Conduct boatride with Coast Guard marine inspector prior to taking passengers.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Documentation
Issued 22 January 1998
Resolved
PROVIDE TRAINING LOG
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Electrical
Issued 11 December 1997
Resolved
Remove household type wiring from inport lighting system and replace with approved marine wiring.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Lifesaving
Issued 4 February 1997
Resolved
PROVIDE LIFEJACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Construction/Loadline
Issued 4 February 1997
Resolved
REPAIR ROTTED WOOD ON DECKHOUSE TOP IN WAY OF SKYLIGHT.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Navigation
Issued 6 February 1996
Resolved
PROVE PROPER OPERATION OF PORT SIDELIGHT, VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 6 February 1996
Resolved
PERMANENTLY INSTALL LIGHTING FOR FOREPEAK.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 6 February 1996
Resolved
CONDUCT AN UNDERWAY OPERATIONAL TEST AND MAN OVERBOARD DRILL.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Construction/Loadline
Issued 6 February 1996
Resolved
IN THE LAZARETTE, REMOVE MOLD GROWTH AND TREAT WOOD AT TRANSOM UNDER DECK BEAM AND SECOND FRAME FROM STARBOARD SIDE.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Engineering
Issued 6 February 1996
Resolved
INSTALL A METALLIC FLAME INPINGEMENT BOWL TO BOTTOM OF FUEL OIL FILTER.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Documentation
Issued 28 November 1995
Resolved
PERFORM NEW STABILITY TEST DUE TO THE ADDITION OF A NEW BAIT TANK. ANY TIME BAIT TANK IS USED, PASSENGER ALLOWANCE TO BE REDUCED BY 15 UNTIL ITEM COMPLETED.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Construction/Loadline
Issued 28 November 1995
Resolved
AFTER RE-FLOATING AND PRIOR TO CARRYING PASSENGERS, PROVIDE A STATEMENT ATTESTING TO THE WATERTIGHT AND STRUCTURAL INTEGRITY OF THE VESSEL.
Condition: Unknown
Due 27 December 1995
Resolved 31 January 1996
Engineering
Issued 28 November 1995
Resolved
PROVIDE A PHOTOGRAPH OF NEW SHAFT INSTALLED AND A COPY OF SALES RECEIPT.
Condition: Unknown
Due 27 December 1995
Resolved 31 January 1996
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
PROVIDE MARKING OR PLACARD FOR MSD OVERBOARD VALVE TO NOT OPEN WITHIN 3 MI OF SHORE OR IN US WATERS.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Fire Fighting
Issued 13 March 1995
Resolved
MARK FIRE STATION, STBD SIDE, MIDSHIPS.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Engineering
Issued 13 March 1995
Resolved
CONDUCT UNDER WAY TEST AND MAN OVERBOARD DRILL-ELECTRONICS, NAV LIGHTS, & EMERGENCY STEERING HAVE BEEN INSPECTED SAT.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 13 March 1995
Resolved
PROCURE JIM BUOY REPAIR KIT AND PATCH CRACKS ON BUOYANT APPARATUS ON STBD SIDE.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 13 March 1995
Resolved
PROCURE 2 CHILD PFD AND REMARK LOCKERS FOR BOTH ADULT AND CHILDREN LIFEJACKETS TO REFLECT PROPER NUMBER. VESSEL IS LIMITED TO 5 CHILD PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Construction/Loadline
Issued 13 March 1995
Resolved
TREAT & SEAL THE FOLLOWING: 1. FROM BOW, FRAME NO. 8, STBD SIDE IN WAY OF BILGE, ATTEMPT TO REPAIR SMALL CRACK WHICH HAS NOT PROPOGATED THROUGH ENTIRE FRAME. 2. FROM FORWARD ENGINE ROOM BULKHEAD, NO. 6 FLOOR TIMBER, STBD SIDE. SLIGHT ROT.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Engineering
Issued 24 August 1993
Resolved
PERMANENTLY ATTACH AND MARK HANDLE FOR SALT WATER INTAKE VALVE IN ENGINE ROOM.
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Accommodation/Occupational Safety
Issued 24 August 1993
Resolved
DISABLE INTAKE FOR SALTWATER BAIT TANK.
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Construction/Loadline
Issued 2 July 1993
Resolved
SEAL/CAULK ANY/ALL SEAMS WHICH ARE NOT WATERTIGHT IN MAIN DECK OF IN WAY OFLAZARETTE.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Construction/Loadline
Issued 2 July 1993
Resolved
CLEAN AND TREAT ROT IN 3 FRAMES STBD SIDE AFT IN 2ND COMP. FROM STERN.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Construction/Loadline
Issued 2 July 1993
Resolved
CROP AND RENEW UNDER DECK STRONG BACK IN FOREPEAK.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Construction/Loadline
Issued 2 July 1993
Resolved
CLEAN AND TREAT FURRING IN FWD STBD CORNER OF E.R. AT BHD AND OVERHEAD.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Fire Fighting
Issued 24 June 1993
Resolved
SUBMIT COPY OF SERVICING REPORT FOR THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Navigation
Issued 24 June 1993
Resolved
PROVIDE UP TO DATE FCC STATION LICENSE.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Documentation
Issued 12 March 1992
Resolved
PROVIDE PROOF OF THE COMPANIES DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Deck/Cargo
Issued 12 March 1992
Resolved
PROVIDE ANCHOR BALL.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Accommodation/Occupational Safety
Issued 12 March 1992
Resolved
PROVIDE A SIX INCH HIGH COAMING FOR THE AFTER DOOR, LEADING INTO THE PASSENGERS LOUNGE, IAW 46 CFR 171.124, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Fire Fighting
Issued 12 March 1992
Resolved
PROVIDE A B-II RATED FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Engineering
Issued 12 March 1992
Resolved
REMOVE THE IMPROPER FUEL LINE FEED FOR THE MAIN ENGINE AND INSTALL A FUEL LINE WHICH COMPLIES WITH 46 CFR 182.20-40, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Construction/Loadline
Issued 5 March 1992
Resolved
VESSEL MUST CONDUCT NEW STABILITY TEST AS THEY HAVE ADDED A BAIT TANK. UNTIL THIS IS ACCOMPLISHED AT ANY TIME THE TANK IS USED PASSENGER AMOUNT MUST BE REDUCED BY 15._x001C_ _x001C_
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Documentation
Issued 18 April 1991
Resolved
PROVIDE DOCUMENTATION SHOWING IMPLEMENTATION OF A DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Documentation
Issued 18 April 1991
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 18 April 1991
Resolved
REPLACE FLOAT FREE LINK FOR BOUYANT APPARATUS.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Engineering
Issued 18 April 1991
Resolved
FIT ALL BILGE SUCTIONS WITH DEBRIS SCREENS.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 14 March 1990
Resolved
PROCURE I ADULT AND 1 CHILD SIZE LIFE PRESERVER. VESSEL IS RESTRICTED TO 61TOTAL PERSONS AND NO MORE THAN 6 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Electrical
Issued 14 March 1990
Resolved
PROVIDE PACKING GLAND FOR THE ELECTRICAL OUTLET IN THE END OF THE BENCH ON THE STARBOARD SIDE IN THE MAIN CABIN.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Engineering
Issued 14 March 1990
Resolved
PROVIDE PROTECTIVE INTERNAL COVERS FOR THE REMOTE FUEL SHUT DOWN HANDLES.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990
Resolved
CLEAN AND TREAT FURRING IN THE ENGINEROOM OVERHEAD ON THE STARBOARD SIDE FROM THE FORWARD TO THE AFT BULKHEADS, AND ABOVE THE TANK ON THE PORT SIDE.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990
Resolved
CLEAN AND TREAT FURRING IN THE OVERHEAD AT THE AFTER BULKHEAD ON THE C/L OF THE AFT COMPARTMENT.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990
Resolved
CLEAN OUT ROTTED DECK BEAM IN AFT COMPARTMENT ON THE STARBOARD SIDE AT THE AFT BULKHEAD MIDWAY BETWEEN THE SKIN OF THE VESSEL AND THE CENTERLINE.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990
Resolved
CLEAN AND TREAT FURRING IN THE OVERHEAD OF THE STEERING COMPARTMENT.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Lifesaving
Issued 14 March 1989
Resolved
PROVIDE 12 ADDITIONAL ADULT PFD'S TO BRING TOTAL ONBOARD TO 63.VSL LIMITED TO 51 TOTAL PERSONS UNTIL CORRECTED.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Deck/Cargo
Issued 14 March 1989
Resolved
REPLACE PVC ENGINE ROOM BILGE SUCTION PIPING WITH METAL PIPING.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989
Resolved
MOUNT FIRE HOSE AT THE FIRE STATION.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Lifesaving
Issued 14 March 1989
Resolved
STENCIL CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Construction/Loadline
Issued 14 March 1989
Resolved
SCRAPE FURRING AND TREAT WITH PENETRATING EPOXY THE DECK BEAMS AND DECK PLANKING IN THE ENGINE ROOM OVERHEAD (MAIN DECK).
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Accommodation/Occupational Safety
Issued 14 March 1989
Resolved
PROVIDE LOCKFOR MSD OVERBOARD VALVE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989
Resolved
REPLACE PVC AND RUBBER PIPING IN FIREMAIN WITH METAL PIPING.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Construction/Loadline
Issued 13 May 1988
Resolved
MAKE FWD BKHD OF E/R WATERTIGHT.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Construction/Loadline
Issued 13 May 1988
Resolved
PROVIDE KEEPER CHAINS FOR ALL WEATHERDECK HATCHES.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988
Resolved
SERVICE FIXED FF CO2 BOTTLES.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 13 May 1988
Resolved
PROVIDE 9 ADULT PFD'S TO BRING TOTAL ONBOARD TO 63. VSL RESTRICTED TO 54 TOTAL PERSONS UNTIL COOORRECTED.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 9 February 1987
Resolved
REPLACE PENNANT LINES ON BUOYANT APPARATUS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Construction/Loadline
Issued 4 April 1985
Resolved
MAKE ALL DECK HATCHES WEATHER TIGHT AND ATTACH HATCHES TO COAMINGS WITH EITHER A KEEPER CHAIN OR HINGES.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Documentation
Issued 4 April 1985
Resolved
CONDUCT A STABILITY TEST.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985