← All vessels
GT-115
GT-115 is a 1948 tank barge. The Coast Guard has recorded 15 inspections since 1982, most recently in March 1994, along with 34 deficiencies.
Records from 1982 to 1994. Most recent: inspection, 23 March 1994.
- Built
- 1948
- Last inspected
- 23 March 1994
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
255086
42422
Flag
UNITED STATES
—
Maury page id
psix-42422
Inspections, by type
…with no type recorded4
Years with a record
11 calendar years (1982–1994)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it930 - Regulatory (Subpart C or D), Net Ton
930 - Regulatory (Subpart C or D), Gross Ton
930 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
23 March 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 855741
26 August 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260371
7 April 1992
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 933141
26 November 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260754
3 July 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 948203
10 August 1990
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1227633
7 September 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 890089
7 April 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 494054
4 August 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345728
16 June 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1208609
8 July 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028572
24 November 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331295
5 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291546
30 June 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973537
30 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278236
Deficiency record · 34
Documentation
Issued 3 July 1991
Resolved
PROVIDE OIL TRANSFER PROCEDURES AND ENSURE THEIR CONTENTS ARE IN ACCORDANCEWITH 33 CFR 155.750._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 July 1991
Resolved
LOOSEN AND LUBRICATE DOG BOLTS TO WATERTIGHT HATCH FOR BOW VOID._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 3 July 1991
Resolved
RENEW LIGHT SCREENS AND ENSURE THAT THEY ARE PAINTED FLAT BLACK AND CORRECTLY ALIGNED._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
REPAIR/REPLACE AND PLACE DECK WINCHES IN A SERVICEABLE CONDITION._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
PAINT EXISTING LIGHT STAND FLAT BLACK._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
LOOSEN AND LUBRICATE DOG BOLTS ON #1 PORT BUTTERWORTH HATCH AND ALSO RENEW GASKET TO WATERTIGHT HATCH COVER._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW PACKING TO REACH ROD ASSEMBLY THAT PENETRATED #1 PORT AND STARBOARD CARGO TANK DOMES._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW FLAME SCREEN TO #1 PORT CARGO TANK P/V VALVE._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW FLAME SCREEN TO #2 PORT CARGO TANK P/V VALVE._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW PACKING TO REACH ROD ASSEMBLY THAT PENETRATED #2 STARBOARD CARGO TANKDOME._x001C_ _x001C_ _x001C_
Documentation
Issued 3 July 1991
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 July 1991
Resolved
RENEW MISSING DOG BOLT TO FWD BUTTERWORTH HATCH ON #3 STARBOARD CARGO TANK AND RENEW HATCH COVER RETAINING PIN._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 July 1991
Resolved
RENEW FLAME SCREEN TO P/V VALVE ON PORT SLOP TANK._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
LOOSEN AND LUBRICATE DOG BOLTS ON WATERTIGHT HATCH FOR STARBOARD SLOP TANK.
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW DAMAGED 1" PIPING LOCATED ON TOP OF STARBOARD SLOP TANKS. (PIPING IS USED FOR STRIPPING AND CROSSOVER FROM PORT TO STARBOARD TANK.)
Lifesaving
Issued 3 July 1991
Resolved
INSTALL HANDLE TO VALVE ON THE AFT SIDE OF STARBOARD SLOP TANKS.
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW MOUNTING BOLTS FOR WARNING SIGN._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
RENEW PACKING TO REACH ROD ASSEMBLY THAT PENETRATES #3 P/S CARGO TANK DOMES._x001C_ _x001C_ _x001C_
Engineering
Issued 3 July 1991
Resolved
RENEW FLAME SCREEN TO P/V VALVE ON #3 PORT CARGO TANK._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 3 July 1991
Resolved
REMOVE PET-COCKS FROM FUEL FILTERS LOCATED ON CARGO PUMP ENGINE AND INSTALLPIPE PLUGS._x001C_ _x001C_ _x001C_
Engineering
Issued 3 July 1991
Resolved
INSTALL CG APPROVED FUEL HOSE TO FUEL FILTER FROM DAY TANK FOR CARGO PUMP ENGINE. REMOVED ALL HOSE CLAMPS ON FUEL HOSES AND INSTALL FACTORY TYPE FITTINGS._x001C_ _x001C_
Construction/Loadline
Issued 3 July 1991
Resolved
RENEW DETERIORATED HYDRAULIC SUPPLY HOSE TO HYDRAULIC STARTER ON CARGO PUMPENGINE._x001C_ _x001C_ _x001C_
Electrical
Issued 3 July 1991
Resolved
RENEW GASKETS TO WATERTIGHT HATCH COVERS AND RENEW GASKET RETAINING RING TOTHE FOLLOWING BUTTERWORTH OPENINGS #4P, #3P AND #2P.
Construction/Loadline
Issued 3 July 1991
Resolved
REMOVE DETERIORATED ELECTRICAL CONNECTIONS AND CONDUITS FROM ON BOARD VESSEL.
Construction/Loadline
Issued 3 July 1991
Resolved
CHECK ALL WATERTIGHT HATCH COVER HINGE PINS AND RENEW AS NECESSARY._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 July 1991
Resolved
REPAINT VESSELS NAME AND PROPER HAILING PORT/HOMEPORT SO THEY ARE PLAINLY AND LEGIBLY MARKED UPON THE VESSEL._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 July 1991
Resolved
REPAINT DRAFT MARKS SO THEY ARE PLAINLY AND LEGIBLY MARKED UPON THE VESSEL._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
CLEAN ALL P/V VALVES AND RENEW BROKEN MOUNTING BOLTS TO P/V VALVE INSPECTION COVERS._x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 3 July 1991
Resolved
ENSURE ALL VALVES ONBOARD VESSEL HAVE VALVE HANDLES INSTALLED._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
ENSURE ALL CARGO TANKS ARE MARKED WITH "DANGER - KEEP OUT"._x001C_ _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
PROVIDE EVIDENCE THAT CARGO TRANSFER SYSTEM RELIEF VALVE HAS BEEN TESTED WITHIN THE PAST YEAR._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
ENSURE CARGO HEADER PRESSURE GAUGE IS OPERABLE AND ACCURATE WITHIN 10 PERCENT._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 3 July 1991
Resolved
PROVIDE EVIDENCE OF HYDRO TEST OF CARGO PIPING TO 1.5 TIMES MAXIMUM ALLOWABLE WORKING PRESSURE WITHIN THE PAST YEAR.
Deck/Cargo
Issued 24 November 1986
Resolved
PROVIDE PROOF TO [name withheld], AL THAT THE ANNUAL TEST OF CARGO PIPING, CARGO HOSES AND RELIEF VALVES REQUIRED BY 33CFR156.170 HAVE BEEN CONDUCTED.NOTIFY OCMI @ P.O. BOX 2924, SUITE 1900, FIRST NATIONAL BANK BUILDING, MOBILE, AL, 36652. ATTN: ACMID.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.