← All vessels
MARY C.
MARY C. is a 1944 tank barge. The Coast Guard has recorded 11 inspections since 1984, most recently in January 2002, along with 14 deficiencies — 1 with no resolution recorded —.
Records from 1984 to 2002. Most recent: inspection, 9 January 2002.
- Built
- 1944
- Last inspected
- 9 January 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
255611
WB5718
42450
Flag
UNITED STATES
—
Maury page id
psix-42450
Inspections, by type
…with no type recorded6
…past their stated due date1
Years with a record
6 calendar years (1984–2002)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it1076 - Regulatory (Subpart C or D), Net Ton
1076 - Regulatory (Subpart C or D), Gross Ton
1076 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
9 January 2002
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1476905
19 September 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1251430
10 March 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1011495
23 January 1987
Drydock Extension
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1314676
4 August 1986
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998436
30 July 1985
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 985554
10 June 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1292126
11 April 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1290394
11 March 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1285792
15 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 977746
23 August 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 439986
Deficiency record · 14
Electrical
Issued 4 August 1986
Resolved
OPERATIONALLY TEST BARGE SERVICE GENERATORS OVERSPEED & LOW LUBE OIL CUTOUTS PRIOR TO TRANSFERRING CARGO OR OPERATING MACHINERY.
Deck/Cargo
Issued 4 August 1986
Resolved
OPEN ALL P-V VALVES FOR INSPECTION PRIOR TO TRANSFERRING CARGO OR OPERATINGMACHINERY.
Deck/Cargo
Issued 4 August 1986
Resolved
OPEN ALL ULLAGES FOR INSPECTION OF FLAME SCREENS PRIOR TO TRANSFERRING CARGO OR OPERATING MACHINERY.
Fire Fighting
Issued 4 August 1986
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AS NECESSARY TO INCLUDE WEIGHTING, REFILLING OR HYDROSTATIC TESTING.
Accommodation/Occupational Safety
Issued 4 August 1986
Resolved
REPLACE ACCESS LADDERS IN FWD COFFERDAM.
Construction/Loadline
Issued 4 August 1986
Resolved
REPAIR/REPLACE WATERTIGHT HATCHES TO FWD COFFERDAM.
Construction/Loadline
Issued 4 August 1986
Resolved
GUAGE BULKHEADS BETWEEN CARGO TANKS 1 P/S & FWD COFFERDAM; CARGO TANKS 8 P/S & AFT COFFERDAM.
Engineering
Issued 4 August 1986
No resolution recorded
OPEN UP FOR INSPECTION OR HYDROSTATICALLY TEST 2 AIR RECEIVERS.
Deck/Cargo
Issued 4 August 1986
Resolved
HYDROSTATICALLY TEST CARGO LINES & PORTABLE HOSE TO 225 PSI PRIOR TO TRANSFERRING CARGO OR OPERATING MACHINERY.
Deck/Cargo
Issued 4 August 1986
Resolved
OPERATIONALLY TEST CARGO PUMP EMERGENCY SHUTDOWN PRIOR TO TRANSFERRING CARGO OR OPERATING MACHINERY.
Deck/Cargo
Issued 4 August 1986
Resolved
OPERATIONALLY TEST THERMAL FLUID HEATER SAFETY SHUTDOWNS PRIOR TO TRANSFERRING CARGO OR OPERATING MACHINERY.
Unknown
Issued 10 June 1985
Resolved
Unknown Component - Unknown Cause/Condition
Construction/Loadline
Issued 11 April 1985
Resolved
MAKE # 7 PORT CARGO TANK AVAILABLE FOR INTERNAL EXAM NOT LATER THAN 16APR85
Deck/Cargo
Issued 15 January 1985
Resolved
MAKE PERMANENT REPAIRS TO #1 PORT CARGO TANK ULLAGE PIPE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.