BUCCANEER

BUCCANEER is a 1925 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1984, most recently in September 2001, along with 42 deficiencies.

Records from 1984 to 2001. Most recent: inspection, 19 September 2001.

Built
1925
Last inspected
19 September 2001
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WH8550
Flag
UNITED STATES
—
Maury page id
psix-42452

Inspections, by type

…with no type recorded9
Years with a record 18 calendar years (1984–2001)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)93.6 ft × 23.0 ft × 10.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEFOE SHIPBLDG CO · BAY CITY, MI, UNITED STATES · built 1925
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 8 February 2005 · expires 28 February 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY6691MMSI not assigned · expired · compulsorily equipped · granted 1 September 1998, cancelled 1 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUMMER OF GEORGE Passenger (Inspected) · MISLE 45448 · 7 April 1997 · activity 16324T13521B Freight Barge · MISLE 425723 · 7 April 1997 · activity 16324

Inspection history · 36

19 September 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418970
1 April 2001 Drydock Extension
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1067135
19 August 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468593
26 June 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1050640
4 May 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1051026
19 May 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 795622
6 May 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1127241
2 March 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1381496
27 August 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 802512
20 July 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1473081
4 June 1997 Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1375074
7 April 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 16324
22 July 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1084553
21 May 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1353939
16 April 1996 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1383246
1 June 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1396316
27 July 1994 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1173767
2 June 1994 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1428349
2 June 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 845255
5 June 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 949870
7 June 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 935091
1 May 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 903131
9 April 1991 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 904954
16 July 1990 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 907091
7 June 1990 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1218787
27 June 1989 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1205850
9 June 1989 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1038571
18 April 1989 Drydock Extension
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1217994
9 June 1988 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 891143
14 July 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1326805
11 June 1987 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1006700
11 August 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1306247
11 June 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 994295
4 March 1986 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 991479
13 June 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 982309
11 December 1984 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1285334

Deficiency record · 42

System not recorded
Issued 19 September 2001 Resolved
Complete reinspection to the satisfaction of the attending Marine Inspector
Condition: Unknown
Due 14 September 2002
Resolved 23 January 2004
Construction/Loadline
Issued 19 September 2001 Resolved
Submit repair proposal and repair to the satisfaction of the attending marine inspector the following: (a). Forward rotted deck and underlay surrounding forward windlass (b). Forward hatch and coaming (sprung)
Condition: Unknown
Due 19 September 2002
Resolved 23 January 2004
Fire Fighting
Issued 2 March 1999 Resolved
Lable CO2 alarm bells inside the machinery space in accordance with 46 CFR 185.612 prior to carrying passengers for hire.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
Relocate the ventilation blower shutdown switch to a point outside the machinery space and in close proximity to the carbon dioxide remote pull station prior to carrying passengers for hire.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
Label the remote pull station and ventilation blower shutdown in clearly visible and legible letters prior to carrying passengers for hire.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
Provide instructions for the activation of the fixed fire extinguishing system in way of the remoted pull station and ventilation blower shutdown prior to carrying passengers for hire. Instructions shall be as required by46 CFR 185.612.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 2 March 1999 Resolved
Provde instruction for the operation of the local manual release of the fixed fire extinguishing system prior to carrying passengers for hire.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 20 July 1998 Resolved
REPLACE RETO REFLECTIVE TAPE ON BOTH LIFERINGS.
Condition: Unknown
Due 22 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 20 July 1998 Resolved
REPLACE 50FT LENGTH OF FIRE HOSE WHICH MEETS UL19/NFPA1962 STANDARD.
Condition: Unknown
Due 22 July 1998
Resolved 28 July 1998
Navigation
Issued 20 July 1998 Resolved
provide current updated charts and publications for operating area.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 20 July 1998 Resolved
Provide 8" bell as required for vessel.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Documentation
Issued 20 July 1998 Resolved
PROVIDE FCC GREAT LAKES AGREEMENT.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 4 June 1997 Resolved
Repair, or remove from vessel, inoperative LORAN receiver.
Condition: Unknown
Due 20 June 1997
Resolved 26 June 1997
Construction/Loadline
Issued 4 June 1997 Resolved
Prove proper operation of watertight door indicator light in pilothouse.
Condition: Unknown
Due 20 June 1997
Resolved 26 June 1997
Lifesaving
Issued 22 July 1996 Resolved
Remove excess oil from engine room bilges.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Provide one universal size exposure/immersion suit for crewmember to conduct in-water entry man overboard rescue.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Construction/Loadline
Issued 22 July 1996 Resolved
Properly install and secure all engine room deck plates.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Navigation
Issued 21 May 1996 Resolved
Tighten steering cables within tolerable standards to satisfaction of Marine Inspector and clean and greese all pulleys.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 21 May 1996 Resolved
Properly mount PRT MDE oil filter ._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 21 May 1996 Resolved
Provide the following repairs to forward (yellow) electric generator: a. seal exhaust leaks, b. repair leaking block/water jacket, & c. install pulley guards.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 21 May 1996 Resolved
Provide following aft generator repairs: a. replace & prevent further chafting of water cooling lines & b. provide pulley guards._x001C_
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996 Resolved
Remove all dead end wires used formerly with MSD & Radar in and around crewquarters entryway.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996 Resolved
Raise mounting for portable fire extinguisher to ER entryway.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996 Resolved
Afix retro reflective material for all (4) buoyant apparatus and all (3) ringbouys.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 2 June 1994 Resolved
Replace lagging on exhaust line on #2 Generator.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Lifesaving
Issued 2 June 1994 Resolved
Replace all float-free links on buoyant apparatus.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 5 June 1992 Resolved
PROVE PROPER OPERATION OF AFT SSG.
Condition: Unknown
Due 5 June 1992
Resolved 5 June 1992
Fire Fighting
Issued 5 June 1992 Resolved
PROVIDE A SCALE TO WEIGH THE FIXED CO2 CYLINDERS, OR HAVE THE SYSTEM PROFESSIONALLY SERVICED.
Condition: Unknown
Due 5 June 1992
Resolved 5 June 1992
Lifesaving
Issued 5 June 1992 Resolved
PROVIDE 1 EACH CHILD TYPE I PFD.
Condition: Unknown
Due 5 June 1992
Resolved 5 June 1992
Fire Fighting
Issued 9 June 1989 Resolved
MISSING PROTECTIVE GUARDS ON MOTORS FOR BILGE PUMP AND AIR COMPRESSOR.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 9 June 1989 Resolved
INSTALL AN ALARM SYSTEM FOR WATERTIGHT DOOR LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
ALL DEAD END ELECTRICAL WIRES NEED TO BE REMOVED.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 9 June 1989 Resolved
6-MAN LIFEFLOAT NEEDS TWO PADDLES, FLOATLITE, AND A PAINTER INSTALLED.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Engineering
Issued 9 June 1989 Resolved
TWO PRESSURE VESSELS IN ENGINE ROOM SHOULD BE MADE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Fire Fighting
Issued 9 June 1989 Resolved
GAUGE ON FIRE MAIN SYSTEM DOES NOT OPERATE PROPERLY TO ASCERTAIN AVAILABLE PRESSURE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 9 June 1989 Resolved
EMERGENCY ESCAPE HATCH FROM CREW'S BERTHING SHOULD BE STENCILED AS REQUIRED.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 9 June 1989 Resolved
ALL STORAGE AREAS FOR LIFE PRESERVERS NEEDS 1 INCH LETTERING AND NUMBERS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Deck/Cargo
Issued 11 June 1987 Resolved
PROVE OPERATION OF ANCHOR WINDLASS IN FREE FALL MODE, PORT AND STARBOARD.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Documentation
Issued 11 June 1987 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH THE GREAT LAKES TELEPHONY AGREEMENT.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1986 Resolved
REPLACE OR REPAIR 53 ADULT AND 03 CHILDRENS LIFEJACKETS. VSL LIMITED TO NUMBER OF SERVICABLE LIFEJACKETS ON BOARD, PFDS TO BE REPLACED OR REPAIRED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Navigation
Issued 11 June 1986 Resolved
TEST AIR RECEIVER RELIEF VALVE AND PROVIDE A CERTIFICATION OF RESULTS, TO BE COMPLETED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Fire Fighting
Issued 11 June 1986 Resolved
INSTALL A NEW POWER DRIVEN FIRE PUMP TO COMPLY WITH 46CFR 181-10.1 PRIOR TOTHE COMPLIANCE DATE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.