Records from 1996 to 2024. Most recent: inspection, 30 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation
Issued 13 November 1997
Resolved
Submit a workplan showing owner's plan for compliance with CCSSC._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 1997
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Documentation
Issued 13 November 1997
Resolved
Submit evidence from flag government or authorized class society that vessel's design meets a recognized class society standard, CCSSC 2.1.1._x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 1997
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Documentation
Issued 13 November 1997
Resolved
Obtain a valid Caribbean Cargo Ship Safety Code Certificate, CCSSC 1.12.1._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 1998
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Construction/Loadline
Issued 9 October 1997
Resolved
Provide means on main deck to remove bilge slops from bilge. _x001C_ Also directed to complete this requirement prior to returning to U.S. Port or NLT 15OCT97.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 9 October 1997
Resolved
Replace forward most port and stbd wooden knees at hul/deck joint in cargo hold prior to 1JAN98. No deck cargo to be loaded higher that 24 inches above main deck above cargo hold. (to preclude cars, 55 gal drum pallets, and other extra heavy deck cargoes.)
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 1998
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Fire Fighting
Issued 19 June 1997
Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP AND EMERG FIRE PUMP.
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997
Resolved
PROPERLY REMOVE ALL LOOSE WIRING AND TERMINATE ALL DEAD END WIRING IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Fire Fighting
Issued 19 June 1997
Resolved
PROVIDE SERVICE CERTIFICATE FOR ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 19 June 1997
Resolved
SERVICE CO2 SYSTEM ENGINE ROOM OR REMOVE SYSTEM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Fire Fighting
Issued 19 June 1997
Resolved
PROVIDE FIXED FIRE HOSE AND CONNECTION IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997
Resolved
PROVIDE SHEILD/COVER FOR OPEN ELECTRICAL SWITCHBOARD
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Construction/Loadline
Issued 19 June 1997
Resolved
PROVIDE STANDARD DISCHARGE OUTLET MAIN DECK FOR BILGE SLOPS PUMPING
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997
Resolved
PROVIDE MEDICAL CERT ON ALL CREW MEMBERS W/IN LAST 2 YRS
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997
Resolved
PROVIDE LIFESAVING SIGNALS PLACARD
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997
Resolved
REPLACE PVC FUEL VENTS WITH STEEL VENT PIPES.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997
Resolved
REMOVE OLD PFD'S IN FORCASTLE AND DESTROY. APPROVED 4 SERVICABLE PFD'S ONLY
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Documentation
Issued 19 June 1997
Resolved
PROVIDE STABILITY BOOK FOR VSL.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997
Resolved
PROVIDE SAFE MANNING CERT, OR PROVIDE REQ'D 2 LICENCED MATES.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Accommodation/Occupational Safety
Issued 19 June 1997
Resolved
PROVIDE GARBAGE BOOK & WASTE MGT PLAN
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997
Resolved
PROVIDE LIFERAFT SERVICING CERTIFICATE
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997
Resolved
PROVIDE PROOF OF FUEL CAPACITY (MAY NEED TRANSFER PROCEDURES)
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997
Resolved
PROVIDE PROOF OF DRYDOCK WITH LAST FIVE YEARS.
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN ENGINE.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Construction/Loadline
Issued 19 June 1997
Resolved
REPLACE WOODEN STRUCTURAL KNEE MEMBER PORT SIDE CARGO HOLD
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 7 July 1996
Resolved
Conduct sally test if cargo exceeds 4 ft or vehicles are carried on deck.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 7 July 1996
Resolved
Install sewage tank vent to terminate with gooseneck on weather deck.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Documentation
Issued 7 July 1996
Resolved
Provide 1996 nautical publications.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Unknown
Issued 7 July 1996
Resolved
VESSEL ISSUED 2 PAGE WORKLIST TO BE COMPLETED FOR AEF CREDIT.
Condition: Unknown
Due 18 July 1996
Resolved 16 July 1996
Fire Fighting
Issued 7 July 1996
Resolved
Provide new fire hose to stbd fire station. (fire hose is provided on port side)
Condition: Unknown
Due 16 July 1996
Resolved 23 July 1996