MAURY USCG vessel records Sign in
← All vessels

SANTA MARIA

SANTA MARIA is a 1963 freight ship. The Coast Guard has recorded 5 inspections since 1996, most recently in January 2024, along with 30 deficiencies and 3 operational controls.

Records from 1996 to 2024. Most recent: inspection, 30 January 2024.

Built
1963
Last inspected
30 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

424745
Flag
BELIZE
—
Maury page id
psix-424745

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (1996–2024)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it145 - Regulatory (Subpart C or D), Gross Ton
91 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

30 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7857849
13 November 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 409626
9 October 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 407244
19 June 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 405176
7 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 393004

Deficiency record · 30

Documentation
Issued 13 November 1997 Resolved
Submit a workplan showing owner's plan for compliance with CCSSC._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 1997
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Documentation
Issued 13 November 1997 Resolved
Submit evidence from flag government or authorized class society that vessel's design meets a recognized class society standard, CCSSC 2.1.1._x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 1997
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Documentation
Issued 13 November 1997 Resolved
Obtain a valid Caribbean Cargo Ship Safety Code Certificate, CCSSC 1.12.1._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 1998
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Construction/Loadline
Issued 9 October 1997 Resolved
Provide means on main deck to remove bilge slops from bilge. _x001C_ Also directed to complete this requirement prior to returning to U.S. Port or NLT 15OCT97.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 9 October 1997 Resolved
Replace forward most port and stbd wooden knees at hul/deck joint in cargo hold prior to 1JAN98. No deck cargo to be loaded higher that 24 inches above main deck above cargo hold. (to preclude cars, 55 gal drum pallets, and other extra heavy deck cargoes.)
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 1998
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1997.
Fire Fighting
Issued 19 June 1997 Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP AND EMERG FIRE PUMP.
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997 Resolved
PROPERLY REMOVE ALL LOOSE WIRING AND TERMINATE ALL DEAD END WIRING IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Fire Fighting
Issued 19 June 1997 Resolved
PROVIDE SERVICE CERTIFICATE FOR ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 19 June 1997 Resolved
SERVICE CO2 SYSTEM ENGINE ROOM OR REMOVE SYSTEM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Fire Fighting
Issued 19 June 1997 Resolved
PROVIDE FIXED FIRE HOSE AND CONNECTION IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Electrical
Issued 19 June 1997 Resolved
PROVIDE SHEILD/COVER FOR OPEN ELECTRICAL SWITCHBOARD
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Construction/Loadline
Issued 19 June 1997 Resolved
PROVIDE STANDARD DISCHARGE OUTLET MAIN DECK FOR BILGE SLOPS PUMPING
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997 Resolved
PROVIDE MEDICAL CERT ON ALL CREW MEMBERS W/IN LAST 2 YRS
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997 Resolved
PROVIDE LIFESAVING SIGNALS PLACARD
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997 Resolved
REPLACE PVC FUEL VENTS WITH STEEL VENT PIPES.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997 Resolved
REMOVE OLD PFD'S IN FORCASTLE AND DESTROY. APPROVED 4 SERVICABLE PFD'S ONLY
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Documentation
Issued 19 June 1997 Resolved
PROVIDE STABILITY BOOK FOR VSL.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997 Resolved
PROVIDE SAFE MANNING CERT, OR PROVIDE REQ'D 2 LICENCED MATES.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Accommodation/Occupational Safety
Issued 19 June 1997 Resolved
PROVIDE GARBAGE BOOK & WASTE MGT PLAN
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Lifesaving
Issued 19 June 1997 Resolved
PROVIDE LIFERAFT SERVICING CERTIFICATE
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997 Resolved
PROVIDE PROOF OF FUEL CAPACITY (MAY NEED TRANSFER PROCEDURES)
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 19 June 1997 Resolved
PROVIDE PROOF OF DRYDOCK WITH LAST FIVE YEARS.
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Engineering
Issued 19 June 1997 Resolved
DEMONSTRATE PROPER OPERATION OF MAIN ENGINE.
Condition: Unknown
Due 19 June 1997
Resolved 4 July 1997
Construction/Loadline
Issued 19 June 1997 Resolved
REPLACE WOODEN STRUCTURAL KNEE MEMBER PORT SIDE CARGO HOLD
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 7 July 1996 Resolved
Conduct sally test if cargo exceeds 4 ft or vehicles are carried on deck.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 7 July 1996 Resolved
Install sewage tank vent to terminate with gooseneck on weather deck.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Documentation
Issued 7 July 1996 Resolved
Provide 1996 nautical publications.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Unknown
Issued 7 July 1996 Resolved
VESSEL ISSUED 2 PAGE WORKLIST TO BE COMPLETED FOR AEF CREDIT.
Condition: Unknown
Due 18 July 1996
Resolved 16 July 1996
Fire Fighting
Issued 7 July 1996 Resolved
Provide new fire hose to stbd fire station. (fire hose is provided on port side)
Condition: Unknown
Due 16 July 1996
Resolved 23 July 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.