USNS BOWDITCH

USNS BOWDITCH is a 1996 unclassified. The Coast Guard has recorded 86 inspections since 1996, most recently in June 2026, along with 46 deficiencies and 2 operational controls.

Records from 1996 to 2026. Most recent: inspection, 23 June 2026.

Built
1996
Last inspected
23 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9075216 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
424853
Flag
UNITED STATES
—
Maury page id
psix-424853

Inspections, by type

…with no type recorded20
Years with a record 28 calendar years (1996–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it4260 - Regulatory (Subpart C or D), Gross Ton
1278 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 86

23 June 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8411958
15 March 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8327198
7 February 2026 COI Inspection · ACP COI Oversight · Vessel Attendance · Administrative Inspection · Re-Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8307387
13 November 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8269121
23 June 2025 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8165031
20 August 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7985087
9 June 2024 Annual Inspection · ACP Drydock Oversight · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7931406
15 May 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7913048
15 April 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7895253
14 April 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7903012
4 April 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7889701
29 November 2023 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7830975
12 October 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7812890
11 October 2023 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7981802
12 September 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7789929
25 July 2023 ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7751438
14 April 2023 Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7668452
30 March 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7660083
28 February 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7642962
20 September 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7563941
30 August 2022 ACP Annual Oversight · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7546432
26 May 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849362
25 May 2022 Liferaft Servicing
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7458745
15 February 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7669877
11 January 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7378908
10 January 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7382207
26 October 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7347772
22 October 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7347770
8 September 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7313241
1 June 2021 ACP COI Oversight · COI Inspection · Re-Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7195484
22 June 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6987087
15 May 2020 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6953570
11 May 2020 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6951179
2 March 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6918520
16 December 2019 Annual Inspection · COI Inspection · ACP COI Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6870706
11 August 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6780281
18 March 2019 Ballast Water Examination · MTSA/ISPS Verification · Drydock Exam · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6640671
8 January 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6610903
26 February 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6354162
1 February 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6347504
19 December 2017 ISM Oversight · Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6326341
14 November 2017 Liferaft Servicing
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6307056
9 June 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6170223
17 April 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6125917
14 April 2016 Administrative Inspection · ACP Annual Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5854592
2 May 2014 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4848596
23 May 2012 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 4319369
13 January 2011 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 3925777
29 March 2009 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3620267
20 October 2008 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3443385
4 March 2008 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3184298
29 April 2007 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2929629
19 March 2007 ACP Annual Oversight · Security Plan Review - VSP · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2885982
27 April 2006 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2650300
22 October 2005 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2594404
3 October 2005 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 2506358
5 April 2005 ACP COI Oversight · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2322725
15 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293116
19 December 2004 In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1973987
23 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2108047
2 May 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2057611
24 March 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2239837
5 March 2004 Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2018461
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996794
15 September 2003 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1905065
25 March 2003 Re-Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1754904
29 May 2002 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1622323
25 April 2002 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1616428
1 March 2001 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362046
24 January 2001 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 171416
3 August 2000 Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1384526
25 April 2000 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1456822
11 April 2000 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 169535
21 June 1999 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1080706
24 March 1999 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1111674
7 January 1999 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 793334
27 June 1998 COI Inspection
Physical examination · Activities Europe · Activity 1381270
28 July 1997 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1364274
27 July 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 108718
11 July 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1117023
2 July 1997 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1442594
20 March 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1101455
27 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394705
31 January 1997 Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1103395
22 January 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452247
19 July 1996 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1086456

Deficiency record · 46

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2026 Resolved
Every ship shall be provided with fire pumps, fire mains, hydrants and hoses complying as applicable with the requirements of this regulation. During testing of emergency fire pump, a leak was discovered at the flange on the discharge side. Make permanent repairs to satisfaction of ABS prior to departure. 74 SOLAS (1997) II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2026
Resolution: Accepted by ABS as finding 1483.0 and repaired with ABS oversight.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 June 2026 Resolved
A launching appliance shall not depend on any means other than gravity or stored mechanical power which is independent of the ship's power supplies to launch the survival craft or rescue boat it serves in the fully loaded and equipped condition and also in the light condition. During inspection, it was found that the pendant for port and starboard lifeboats had an improperly measured brake release cable would not allow the operator of the lifeboat to gravity deploy the lifeboat. Make repairs to satisfaction of ABS prior to departure. 74 SOLAS (2004) III/34 LSA 6.1.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2026
Resolution: Accepted by ABS as finding 1484.0 and repaired with ABS oversight.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 June 2026 Resolved
An immersion suit…of an appropriate size, shall be provided for every person assigned to crew the rescue boat or assigned to the marine evacuation system. During immersion suit donning drill, 01 crew members were not able to don suits due to improper size. Provide crew with proper suits so that member can don suit in 2 minutes or less. 74 SOLAS (2004) III/7.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 25 June 2026
Resolution: Received video of member able to don issued immersion suit in under two minutes. All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 June 2026 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. During inspection, 04 portable foam containers were found cracked and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 17 June 2026
Resolution: Accepted as ABS finding 1485.0 and replaced with ABS oversight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2026 Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. During inspection, it was found that the T-handle that is required to secure the e-gen fuel tank was missing. Replace t-handle and demonstrate use for fuel shut off to satisfaction of ABS. 74 SOLAS (1997) II-2/15.2.5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 17 June 2026
Resolution: Accepted as finding 1487.0 and T-Handle replaced with ABS oversight
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 June 2026 Resolved
Every lifeboat shall be fitted with a device to secure a painter near its bow. The device shall be such that the lifeboat does not exhibit unsafe or unstable characteristics when being towed by the ship making headway at speeds up to 5 knots in calm water. During inspection, both port and starboard lifeboat painters were found to be deteriorating polypropylene line. Replace with new to satisfaction of ABS. 74 SOLAS (2004) III/34 LSA CODE 4.4.7.7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 17 June 2026
Resolution: Accepted by ABS as finding 1488.0
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2025 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. Fire detection panel has several trouble alarms present. Zone 5 did not alarm when tested. Rectify trouble alarms and test system to ensure proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2025
Resolution: Present Trouble alarms were verified to be corrected and tested by the attending class surveyor. Zone 5, Zone 1, Zone 10 and Zone 18 were all found satisfactory during the class survey.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2024 Resolved
The fire integrity of the division shall be maintained. Identified 02 MCTs that had loose cable penetrations IWO of steering propulsion room STBD forward bulkhead. additionally found through out the vessel Roxtec MCTs blocks from a different manufacturer. Have Roxtec technician certify all MCT installations that have mixed manufacture blocks.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2024 Resolved
The fire integrity of the division shall be maintained. Identified multiple areas in the engineering spaces where the A-60 insulation is missing, damaged or inadequately repaired most notably (2-80-2 overhead, machine shop hatch), asses and restore all A-60 boundaries.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 August 2024 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. 2-80-2 & 2-106-2 A-0 doors/frames are wasted/compromised, FSD 1-66-1 does not secure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 August 2024 Resolved
All life saving appliances shall be in working order and ready for immediate use. STBD Lifeboat topside SOLAS retro reflective tape is weathered/faded and no longer meets minimum coefficient of retro-reflection. Additionally, windows visibility is compromised due to excessive grime and salt.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 August 2024 Resolved
All floor grating around propulsion/steering gear flat is not secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2024
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 8 August 2024 Resolved
Periodic Safety Test Procedures (PSTP) documents approved by the Coast Guard must be retained aboard. Provide USCG MSC or ACS(ABS) PSTP approval letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 16 June 2026
Resolution: ABS Verified PSTP approval letter onboard with Finding #1450.8.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2024 Resolved
Ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Identified clear fire hazard with Excessive exhaust soot caked on gratings, walls, and piping IWO exhaust trunk center fiddley in between 1 & 2 engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2024
Resolution: cleaned to the satisfaction of RO (ABS)
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 9 June 2024 Resolved
Main and auxiliary machinery essential for the propulsion, control and safety of the ship shall provide effective means for its operation and control. Several vital alarms had been modified or disabled. After troubleshooting the outstanding list is as follows: NO3 generator cylinder 9 temp, No2 generator cylinder #8 temp, Azi phase failure STBD/PORT pumps, I/O bus 1&2 circuit failure TLI FO tanks and potable water tanks. repair to OEM and follow Risk Mitigation plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 15 June 2026
Resolution: Cleared during ACP COI Renewal MISLE Activity 8307387.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 August 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and read for immediate use. Vessel's port lifeboat/rescue boat suffered a steering casualty. Make permanent repairs prior to departure. 74 SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2022
Resolved 31 August 2022
Resolution: Vessel made repairs to the Port life boat, operational test all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 August 2022 Resolved
Fire-fighting systems and appliances shall be kept in food working order and readily available for immediate use. Pipe to hurricane siren for fixed clean agent system in engine room is broken and separated from siren. Make permanent repairs prior to departure. 74 SOLAS (20) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2022
Resolved 31 August 2022
Resolution: Permanent repairs were made to pipe.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 August 2022 Resolved
Fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. Vessel's fire detection system is displaying a trouble indication and a ground fault indication. Make permanent repairs prior to departure. 74 SOLAS (20) II-2/14.2.1.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2022
Resolved 1 September 2022
Resolution: CG835 was coded to code 50 and written to be cleared by class. Technician arrived to vessel and made repairs to zones and provided a fitness for service and service report uploaded into activity documents.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 30 August 2022 Resolved
Vessel shall be fitted with oil filtering equipment. Vessel's OWS 15ppm alarm is not operational. Make permanent repairs or prove vessel can store oily water for intended voyage prior to departing each port. MARPOL Annex I/14.1
Action required: 705 - Other - as specified
Due 30 August 2022
Resolved 31 August 2022
Resolution: Vessel proved proper operation of OWS.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 August 2022 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Multiple embarkation and emergency lights were extinguished on port and stbd muster stations. 74 SOLAS (97) III/11.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 August 2022 Resolved
Minimum fire integrity of bulkhead and decks shall be prescribed in tables 44.1. Fire insulation is missing on aft engine room bulkhead. 74 SOLAS (97) II-2/44.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 August 2022 Resolved
Door fitted in bulkhead of machinery spaces category A shall be self closing. Vessel has AC condensate line running through fire door. 74 SOLAS (97) II-2/47.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 August 2022 Resolved
Containers for the storage of fire extinguishing medium shall be designed to the satisfaction of the Administration. Vessel does not have warning signage indicating storage area contains CO2.74 SOLAS (97) II-2/5.1.12
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 August 2022 Resolved
Communication shall be available throughout the service spaces and control stations. Vessel's phone in the forward pump room is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2019 Resolved
Rapid recovery of the rescue boat shall be possible when loaded with its full complement of persons and equipment. The rescue boat is not capable of being recovered rapidly due to the aft fall cable twisting and seizing as the boat is being recovered.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Accepted by ABS, short term SLC issued designating the starboard life boat as the rescue boat until 31APR2020.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2019 Resolved
The construction of all doors and door frames in "A" class divisions, sith the means of securing them when closed, shall provide resistance to fure as well to passage of smoke and flame, as far as proctiable. A class division doors were found to not provide resistnace to fire of passage of smoke due to openings around oatching mechinsm and missing gasket materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 20 December 2019
Resolution: ABS accepted as a condition of calss.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 December 2019 Resolved
Emergency Generating set arrangement to me automatically started shall be equipped with starting. A second source of energy shall be provide for an additional three starts within 30 minutes.
Action required: 10 - Deficiency Rectified
Due 17 December 2019
Resolved 17 December 2019
Resolution: Spare batteries were placed in the generator room as required by regulation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2019 Resolved
The minimum fire integrity of bulkheads and decks shall be as perscribed in tables 44.1 and 44.2. Cable penetration located in way of the stairwell to falley corridor was found to be packed impoperly, adjacent bulkhead also found to be holed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 20 December 2019
Resolution: ABS accepted as outstanding condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2019 Resolved
Electrical installations shall be such that the safety of passengers,crew,and ship free from electrical hazards will be endured. Remove dead end wiring identified in the steering flat and machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 28 January 2020
Resolution: ABS surveryor verified that the cables identified were secured, taged out and wrapped up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2019 Resolved
Provide required high temperature fluid test equipment for periodic safety procedures.
Action required: 705 - Other - as specified
Due 30 June 2020
Resolved 22 June 2020
Resolution: HT test equipment onboard.
Operations/Management › Drills/Instruction › Fire
Issued 2 May 2014 Resolved
Vessel crew performed a subpar fire drill. Issued 01 835 - Vessel crew is required to conduct 05 fire drills in the next week. Drills must, as far as practicable, be conducted as if there were an actual emergency. Master shall send drill log entries to the OCMI.
Due 27 May 2014
Resolved 27 May 2014
Resolution: Received email from Master with attached drill log entries.
Engineering › Generator (propulsion/auxiliary-electric) › Feeder Circuitry
Issued 19 March 2007 Resolved
Found emergency switchboard not transfering load to emergency generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 21 March 2007
Resolution: Fixed switchboard.
Engineering › Steering Gear System › Motor
Issued 19 March 2007 Resolved
Found fractures in the starboard side slewing gear on Z-drive.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 3 July 2007
Resolution: Reviewed Class report attesting to renewal of slewing gear and ring
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 March 2003 Resolved
Properly install bunk lights at hospital space bunks. LEGACY COMPONENT DESC: Bunk Light in Hospital Space Bunks
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 March 2003
Resolution: Left as a verbal requirement.
Engineering › Fuel Oil Service System
Issued 25 March 2003 Resolved
Repair leaks on Emergency Generator fuel oil tank manhole cover. LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Due 25 March 2003
Resolved 25 March 2003
Resolution: Leak was repaired.
Construction/Loadline › Penetrations
Issued 25 March 2003 Resolved
1. Remove petcocks from E/R sounding tubes LEGACY COMPONENT DESC: Sounding tubes.
Condition: Improper Installation
Due 25 March 2003
Resolved 25 March 2003
Resolution: Left as a verbal requirement.
Engineering › Fuel Oil Service System › Filter
Issued 25 March 2003 Resolved
Place metal plugs on all racor filters and remove plastic connectors.
Condition: Improper Installation
Due 25 March 2003
Resolved 25 March 2003
Resolution: Metal plugs are installed.
Fire Fighting › Structural - C Class Divisions › Corridors
Issued 25 March 2003 Resolved
Plug holes in interior class "C" bulkheads
Condition: Improper/Lack of Maintenance
Due 25 March 2003
Resolved 26 March 2003
Resolution: Left as a verbal requirement.
Lifesaving
Issued 28 July 1997 Resolved
Conduct starboard boat drill.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Lifesaving
Issued 28 July 1997 Resolved
Provide 14 life jacket waterlights for exposure suits.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Fire Fighting
Issued 2 July 1997 Resolved
Update vessel fire control plan to reflect bow thruster CO2 installation.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Fire Fighting
Issued 2 July 1997 Resolved
Install instructions/schematic for bow thruster CO2 installation in accordance with 46 CFR 193.15-10(h).
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 22 January 1997 Resolved
15AUG96: EXCESSIVE FORCE REQUIRED TO ACTIVATE LIFEBOAT DAVIT BRAKE RELEASE VIA INSTALLED REMOTE CABLE ABOARD P/S LIFEBOATS.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Lifesaving
Issued 22 January 1997 Resolved
15AUG96: REDESIGN FORWARD LIFEBOAT GRIPES ON P/S BOATS TO PREVENT FOULING ON GRIPE GUIDES AND RELEASING GEAR DURING LAUNCH.
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Unknown
Issued 19 July 1996 Resolved
HAVE LIFE RAFTS SERVICED. TO BE COMPLETED PRIOR TO VESSEL DEPARTING THE PORT OF PASCAGOULA, MS.
Condition: Unknown
Due 15 August 1996
Resolved 23 August 1996
Unknown
Issued 19 July 1996 Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 15 August 1996
Resolved 23 August 1996