Records from 2016 to 2017. Most recent: inspection, 10 January 2017.
Inspection history · 4
10 January 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6068975
6 January 2017
Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6056694
21 December 2016
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6061120
16 December 2016
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6058921
Lifesaving › Lifeboat › Propulsion Starting System
Issued 6 January 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2017
Resolved 11 January 2017
Resolution: Vessel had repaired the electric coil for the starter.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 January 2017
Resolved
0725-Fixed Fire Extinguishing Installation-Suitable provisions shall be made to prevent inadvertent admission of the medium to any space. The CO2 storage room had safety pins missing on three cylinder manual control heads and one loose charge hose connection. 74 SOLAS (97) II-2/5.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2017
Resolved 11 January 2017
Resolution: Safety pins were placed on the manual control heads on the three cylinders, and tightened the loose charge hose.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 6 January 2017
Resolved
1410-Propulsion main engine-The condition of the ship and its equipment shall be maintained to conform w the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The main diesel engine #6 cylinder jacket water seal is actively leaking. 74 SOLAS (97) I/11.a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2017
Resolved 11 January 2017
Resolution: The vesssel replaced the seal ring on the #6 cylinder and leak ceased.
Electrical › Electric Generation Source (service) › Generator
Issued 6 January 2017
Resolved
1430-Auxiliary engine-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #2 generator has improper repair on jacket water cooling line utilizing a hose clamp and rubber patch. 74 SOLAS (97) I/11.a
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 January 2017
Resolved 11 January 2017
Resolution: The vessel had cut the part of pipe leaking, and replaced with a new portion and welded on.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 January 2017
Resolved
1720-Control of discharge of oil-Oil filtering equipment reffered shall be of design approved by the Administraion and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. A certificate of calibration for the oil content meter was not onboard and the meter lacked a tamper seal. MARPOL I/14.6
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 January 2017
Resolved 16 February 2017
Resolution: Class society provided certificate of calibration for oil content meter.