MAURY USCG vessel records Sign in
← All vessels

NORTH STAR

NORTH STAR is a 1949 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1985, most recently in April 2021, along with 90 deficiencies — 9 with no resolution recorded —.

Records from 1985 to 2021. Most recent: inspection, 13 April 2021.

Built
1949
Last inspected
13 April 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9016
Flag
UNITED STATES
368058140
Maury page id
psix-42490

Inspections, by type

…with no type recorded2
…past their stated due date2
Years with a record 29 calendar years (1985–2021)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.5 ft × 14.6 ft × 3.6 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ.W. NOLAN & SONS · ERIE, PA, UNITED STATES · built 1949
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portAU GRES, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4728MMSI 368058140 · active · compulsorily equipped · granted 13 September 2018, expires 13 September 2028 · licensed under a name not among this hull’s recorded names (not shown)
WDB9016MMSI 366968110 · expired · compulsorily equipped · granted 30 July 2004, cancelled 4 October 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCJ8611MMSI not assigned · expired · voluntarily equipped · granted 18 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

13 April 2021 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7174474
7 August 2019 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6775933
13 September 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6539743
5 July 2017 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6198600
25 April 2017 Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6136093
21 June 2016 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5915113
25 April 2016 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5862601
23 July 2015 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5194328
21 July 2015 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5194179
6 July 2012 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4367820
6 June 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4335561
20 July 2011 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4089359
14 July 2009 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3529036
28 August 2008 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3311024
2 July 2008 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3076004
15 May 2008 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3214353
15 May 2007 COI Inspection · Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2899891
21 August 2006 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2754695
22 June 2006 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2687940
30 May 2006 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2664287
13 April 2006 Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2626673
26 September 2005 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2501135
8 September 2005 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2487326
30 August 2005 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2474305
29 August 2005 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2478350
5 July 2005 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2415410
29 July 2004 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2157151
13 July 2003 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2742936
13 June 2002 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1655456
3 October 2001 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1462993
24 June 1999 COI Inspection · Inclining Experiment
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1381687
27 May 1998 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1438738
27 May 1998 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1438739
20 June 1996 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1404202
21 June 1994 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1358450
29 July 1993 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 847527
19 June 1993 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 845935
17 May 1993 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 830126
11 May 1993 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1141100
11 May 1993 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1147940
9 December 1992 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1136876
12 June 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1264487
27 June 1990 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 902592
25 June 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1045239
22 August 1988 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1352578
30 June 1988 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1205767
11 August 1987 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1337288
2 July 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 998570
2 July 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1196121
10 June 1986 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1302511
23 October 1985 Credit Drydock · Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 983552

Deficiency record · 90

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2021 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date (05JUL2018). Vessel is overdue for annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2019 No resolution recorded
Obtain correct number of child lifejackets as required by COI. Limited to 04 Child passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 August 2019 No resolution recorded
First aid kit contents must meet requirements of 184.710/160.041
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 August 2019 No resolution recorded
A vessel on a great lakes route must carry 6 red hand flares and 6 orange smoke signals. Flares on board are expired. 46 CFR180.86
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 August 2019 No resolution recorded
The floating waterlight must be attached around the body of the lifefloat by a uv resistant 3/8" lanyard at least 18' in length and 2 4' paddles. 46CFR180.175 (f)(4) and (f)(2)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2019 No resolution recorded
At least one lifebuoy must have a lifeline-buoyant, 60' long, adequate breaking strength, and UV resistant.
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 August 2019 No resolution recorded
Make VHF radio DSC capable.
Action required: 701 - Prior to carriage of passengers/cargo
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 13 September 2018 Resolved
Vessel has no DAPI paperwork available. Cessel shall supply company policy, current crew list, and random testing (if any)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2018
Resolved 1 October 2018
Resolution: Owner provided proof of DAPI enrollment with Michigan Charter Boat Association
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 September 2018 No resolution recorded
Vessel Great Lakes Agreement is expired. Provide new/upddated radio agreement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018 Resolved
Vessel is missing one child lifejacket. Vessel is only authorized to get underway with 05 children under 90lbs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 26 October 2018
Resolution: One child life jacket was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 September 2018 Resolved
Provide/replace battery for LF float light.Limited to day light ops until fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 17 September 2018
Resolution: Battery was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Label fuel shut offs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 17 September 2018
Resolution: CAPT made signs for the fuel shut-offs
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Provide emergency flash lights for the operating station, and machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 1 October 2018
Resolution: Two flash light were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 September 2018 Resolved
Provice EPIRB inspection log.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 1 October 2018
Resolution: Vessel provided inspection log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018 Resolved
Renew Retor Reflective tape on 05 adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 3 October 2018
Resolution: Old life jackets were removed form the vessel. They have what is required.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 September 2018 Resolved
Provide vessel log book
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 1 October 2018
Resolution: Vessel provided log book
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 September 2018 Resolved
Provide lifesaving inspection log
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 1 October 2018
Resolution: Vessel provided log book
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 September 2018 Resolved
Provide new/or updated chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 17 September 2018
Resolution: CAPT replaced chart.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 September 2018 Resolved
Provide Rules of the Road
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 17 September 2018
Resolution: CAPT purchased a new rules of the road for the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 September 2018 Resolved
Provide light list and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 17 September 2018
Resolution: CAPT printed out light list and coast pilot and placed them on the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 September 2018 Resolved
Post Emergency broadcast placard
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 17 September 2018
Resolution: Placard was posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Post Emergency Instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 1 October 2018
Resolution: Vessel posted Emergency instructions.
Documentation › Certificates/Documents › Permit, Other
Issued 5 July 2017 Resolved
Provide marine radio operators permit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 14 September 2018
Resolution: One master updated his permit
Lifesaving › Lifebuoys › Serviceable
Issued 5 July 2017 Resolved
Provide retroflective material to the lifering in four locations equidistant on both sides of the buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 September 2018
Resolution: Reto tape was added to the lifering
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 5 July 2017 No resolution recorded
Provide new connection to isolate sewage gases within the holding tank. The current hose connection to fitting is broken and taped allowing gases to escape within the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Great Lakes Load Line Certificate
Issued 21 June 2016 Resolved
There was no FCC Great Lakes Agreement available.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 6 July 2017
Resolution: Radio inspection sighted and valid until 2018.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 June 2016 Resolved
Retroreflective tape missing/poor condition on two lifejackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 7 August 2019
Resolution: Verified lifejackets on board had adequate retroreflective material.
Lifesaving › Hand Flares › Expired
Issued 21 June 2016 Resolved
Two of six required flares were outdated.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 6 July 2017
Resolution: Flares updated.
Lifesaving › Buoyant Smoke Signals › General
Issued 21 July 2015 Resolved
Provide 6 smoke signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2015
Resolution: Smoke signals provided.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 21 July 2015 Resolved
Renew lifeline around the BA. The current line is heavily sun damaged and friable.
Action required: 705 - Other - as specified
Due 1 August 2015
Resolved 24 July 2015
Resolution: Life line around BA renewed.
Communications › Radio Communications › EPIRB
Issued 21 July 2015 Resolved
Renew hydrostatic release. (expired in 2014)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2015
Resolution: New hydrostatic release installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 21 July 2015 Resolved
Renew raw water hose on port side forward of the main engine. (cracked - leaking)
Action required: 705 - Other - as specified
Due 1 August 2015
Resolved 24 July 2015
Resolution: Hose renewed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 July 2015 Resolved
Hairline fracture within the overboard discharge raw water line. Make permanent repairs to the line.
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 25 April 2016
Resolution: Overboard discharge line and fitting renewed. Weld examined satisfactory.
Communications › Radio Communications › EPIRB
Issued 6 July 2012 Resolved
EPIRB did not have proper proof of registration with NOAA
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2012
Resolution: FCC tech R. Passage (lic#: 002180078) inspected radio installation.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 6 July 2012 Resolved
Vessel did not have annual radio inpsection conducted IAW GLA
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2012
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 6 July 2012 Resolved
Inadequate pressure from the vessel's emergency fire pumping arrangement
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 7 July 2012
Resolution: Provided portable pump until permanent repairs can be made to fixed system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 July 2011 Resolved
Replace screw type wire nuts with crimp type connecting VHF radio to main power.
Due 29 July 2011
Resolved 5 July 2012
Resolution: Verified proper electrical installation using crimp connections.
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 July 2011 Resolved
Provide dedicated power supply to VHF radio.
Due 29 July 2011
Resolved 5 July 2012
Resolution: Verified compliance with ensuring a dedicated power supply for the VHF radio
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 20 July 2011 Resolved
Replace 6-10 person weak link with proper sized for 26 person BA.
Due 29 July 2011
Resolved 5 July 2012
Resolution: Observed vessel replaced said weak link with appropriate 21 or more person weak link.
Lifesaving › Lifebuoys › Stowage
Issued 20 July 2011 Resolved
Fix life line to the body of the Ring Buoy and connect water light with corrosion resistant quick release clip.
Due 29 July 2011
Resolved 1 August 2012
Resolution: Added corrosion resistant clip to line from light and attached life line to ring body
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 July 2011 Resolved
Provide all records for Drug and Alcohol program, training and testing.
Due 29 July 2011
Resolved 5 July 2012
Resolution: Vessel in compliance with Drug and Alcohol program requirements
Lifesaving › Hand Flares › Expired
Issued 2 July 2008 Resolved
Provide up dated flares.
Due 1 August 2008
Resolved 1 August 2008
Resolution: Completed
Construction/Loadline › Hull › Bottom Plating
Issued 2 April 2007 Resolved
Replace sections on the bottom plating due to excessive wastage greater than 25%. This must be completed prior to taking on passangers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2007
Resolved 15 May 2007
Resolution: corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 June 2006 Resolved
Provide a 3-6 ft. uv protected line for the ring buoy light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2006
Resolved 21 August 2006
Resolution: Six foot UV resistant line provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 June 2006 Resolved
The reing buoy needs to have retroreflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2006
Resolved 14 August 2006
Resolution: New retroreflective tape placed on ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 June 2006 Resolved
Provide two childs life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2006
Resolution: Life jackets were added.
Communications › Radio Communications › EPIRB
Issued 8 June 2006 Resolved
Provide 406MHz and install in a float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2006
Resolution: 406MHz installed.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 17 April 2006 Resolved
Install cotter pin on MDE throttle assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Cotter pin has been installed on MDE.
Engineering › Steering Gear System › Rudder
Issued 17 April 2006 Resolved
Make permanent repairs to fracture at top of rudder intersection w/pintal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Permanent repairs have been made to the rudder intersection.
Engineering › Steering Gear System › Rudder Bearing
Issued 17 April 2006 Resolved
Replace cutlass bearings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Cutlass bearing has been replaced.
Engineering › Steering Gear System › Rudder
Issued 17 April 2006 Resolved
Replace prop as orginal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: The prop has been retooled to the satisfaction of the Marine Inspector.
Fire Fighting › Fire Main › Valves
Issued 17 April 2006 Resolved
Replace through hull valve/piping IWO fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: New piping has been installed. Note, piping used is of dissimilar metal. The owner and operator have been made aware of the potential of electrolysis.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 17 April 2006 Resolved
Adjust fixed fire pump to relieve with pulled assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Fire pump has been moved to relieve the strain on the pully assembly.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 17 April 2006 Resolved
Replace/Inspect fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Fire extinguishers have been tested by certified organization.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 April 2006 Resolved
Replace as orginal wet exhaust pipe and flex hose assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Exhaust pipe and flex hose have been replaced .
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 31 August 2005 Resolved
Provide 5 adult life jackets. Limited to only 42 adult passengers.
Due 15 September 2005
Resolved 31 August 2005
Resolution: Life jackets have been provided.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 31 August 2005 Resolved
Provide 3 child life jackets. Limited to one child passenger.
Due 15 September 2005
Resolved 5 September 2005
Resolution: Childs life jackets have been purchased and placed on boat.
Lifesaving › Lifefloat › Painter
Issued 31 August 2005 Resolved
Replace 150 ft. painter.
Due 7 September 2005
Resolved 5 September 2005
Resolution: 150 ft. painter has been replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 August 2005 Resolved
Splice in lifeline to buoy ring.
Due 7 September 2005
Resolved 5 September 2005
Resolution: Line has been spliced into buoy ring line.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 5 July 2005 Resolved
Provide that 50% of crew is CPR qualified.
Due 1 August 2005
Resolved 1 August 2005
Resolution: 50% of crew is CPR qualified.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 July 2005 Resolved
Replace 8 adult and 4 childs life vests.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2005
Resolution: Life jackets have been provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 July 2005 Resolved
Replace retro tape on 7 adult and 2 childs life vests.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: Retro reflective tape has been replaced on 7 adult and 2 childs life vests.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2005 Resolved
Replace first aid kit with approved 46CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: New first aid kit has been provided on board vessel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 July 2005 Resolved
Provide a permanent affixed ladder to access upper deck.
Due 14 July 2005
Resolved 31 August 2005
Resolution: Ladder has been permanently affixed.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 5 July 2005 Resolved
Provide 18' line on floating light on life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: 18'' line has been provided for floating light on life ring.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 July 2005 Resolved
Provide rubber caps for folding chairs on weather deck.
Due 1 August 2005
Resolved 1 August 2005
Resolution: Chairs requiring rubber caps have been removed from the vessel.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 30 June 2005 Resolved
Properly mount sewage tank.
Due 14 July 2005
Resolved 14 September 2005
Resolution: Tank has been properly mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 June 2005 Resolved
Prove wiring for sewage is UL marine/ boat approved.
Due 14 July 2005
Resolved 14 July 2005
Resolution: Wiring is UL approved according to the Owner/ Operator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 June 2005 Resolved
Trace and lable or remove dead-end wires. Cap dead end wires if not being removed.
Due 14 July 2005
Resolved 14 July 2005
Resolution: All dead-end wires have been caped or removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 June 2005 Resolved
Install safety guards around engine belts.
Due 14 July 2005
Resolved 14 July 2005
Resolution: Safety guards have been installed.
Lifesaving › Lifebuoys › Size
Issued 30 June 2005 Resolved
Replace ring buoy with Coast Guard approved ring buoy and stencil it.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2005
Resolution: Ring bouy has been replaced with Coast Guard approved Ring bouy and is stenciled.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 June 2005 Resolved
Service type B-II
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: Type B-II fire extinguisher has been serviced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 June 2005 Resolved
Provide dark or UV protected 60' line for life ring.
Due 14 July 2005
Resolved 17 July 2005
Resolution: 60'' line for life ring has been replaced with new line.
Lifesaving › Lifebuoys › Stowage
Issued 30 June 2005 Resolved
Provide quick release clip for light on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: Quick release clip for light on ring bouy has been replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 June 2005 Resolved
Repair STBD Nav Light.
Due 14 July 2005
Resolved 14 July 2005
Resolution: STBD Nav light replaced with new light bulb.
Engineering › Fuel Oil Service System › Valve
Issued 30 June 2005 Resolved
Mark fuel shut off valve with direction of turn.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2005
Resolution: Fuel shut off has been marked with direction of turn.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 June 2005 Resolved
Replace link with appropriate size link.
Due 1 August 2005
Resolved 31 August 2005
Resolution: Link was found to be appropriate size. No replacement needed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 July 2004 Resolved
Vessel not ready to operate commercially as per 46 CFR Subchapter T regulations. Vessel is not to operate as a commercial vessel until completion of Coast Guard Vessel Inspection.
Due 29 July 2005
Resolved 14 July 2005
Lifesaving › Lifejacket/PFD (General)
Issued 13 June 2002 Resolved
Provide an additional 18 adult lifejackets. Vessel is restricted to a total of 33 persons until this requirement is cleared to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 13 September 2002
Resolved 13 September 2002
Electrical
Issued 21 June 1994 Resolved
Provide permenant lighting for engine space and remove temporary lighting. New fixtures and wiring shall be for marine use.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Fire Fighting
Issued 21 June 1994 Resolved
Provide 2 - BII USCG Marine type II fire extinguishers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1994
Resolved 29 June 1994
Lifesaving
Issued 21 June 1994 Resolved
Provide 3 red hand held distree signals.
Condition: Unknown
Due 23 June 1994
Resolved 29 June 1994
Documentation
Issued 21 June 1994 Resolved
Provide proof of compliance with 46 CFR 16, drug testing for master and crew.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Lifesaving
Issued 21 June 1994 Resolved
Modify center PFD storage for easier storage.
Condition: Unknown
Due 23 June 1994
Resolved 29 June 1994
Lifesaving
Issued 21 June 1994 Resolved
Properly mark childrens PFD storage.
Condition: Unknown
Due 23 June 1994
Resolved 29 June 1994
Electrical
Issued 19 June 1993 Resolved
PROPERLY SPLICE ENGINEROOM WIRING AND INSTALL IN JUNCTION BOX WITH COVER.
Condition: Unknown
Due 19 June 1993
Resolved 19 June 1993
Accommodation/Occupational Safety
Issued 19 June 1993 Resolved
PROVIDE PERMANENT TOILET FACILITIES FOR OPERATION ON SAGINAW BAY. TEMPORARYFACILITY MAY BE INSTALLED UNTIL O AUG 93.
Condition: Unknown
Due 19 June 1993
Resolved 19 June 1993
Documentation
Issued 12 June 1992 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE NEW FCC RADIO CERTIFICATE.
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992
Fire Fighting
Issued 12 June 1992 Resolved
PROVIDE NEW HAND FIRE PUMP OF THE DIAPHRAM TYPE. _x001C_
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992
Lifesaving
Issued 12 June 1992 Resolved
PROVIDE 11 ADULT LIFEJACKETS AND 1 CHILD LIFEJACKET. UNTIL PFD'S ARE ON _x001C_ BOARD, VESSEL IS LIMITED TO 40 TOTAL PERSONS.
Condition: Unknown
Due 12 June 1992
Resolved 12 June 1992

Ownership record