RIO RITA

RIO RITA is a 1949 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1985, most recently in June 2025, along with 45 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2013.

Records from 1985 to 2025. Most recent: inspection, 18 June 2025.

Built
1949
Last inspected
18 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4641
Flag
UNITED STATES
367076110, 368421350
Maury page id
psix-42511

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 34 calendar years (1985–2025)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.2 ft × 13.2 ft × 5.1 ft
Registered tonnagegross 13 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAKECRAFT WELDING CO · PORT CLINTON OH · built 1949
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT CLINTON, OH
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 23 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3959MMSI 368421350 · active · compulsorily equipped · granted 28 May 2025, expires 28 May 2035
WDJ4641MMSI 367076110 · active · compulsorily equipped · granted 29 March 2017, expires 29 March 2027
WE7006MMSI 367076110 · cancelled · compulsorily equipped · granted 23 December 2015, cancelled 23 March 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

18 June 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8162653
14 March 2023 Appeal
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7650765
15 February 2023 Appeal
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7640239
16 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7457481
5 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7445322
2 May 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7439866
31 January 2022 Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7388450
19 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7179635
5 May 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6953028
29 April 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6673696
9 April 2018 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6388040
20 April 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6129063
5 January 2017 Internal Structural Exam · Examination of Repairs · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6066433
17 May 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5880283
9 May 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4307087
6 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3444202
21 April 2008 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3188625
18 August 2006 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2752008
2 August 2006 Plan Review "T" Boat
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2733768
20 April 2006 Simplified Stability Test
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2629054
20 March 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2606054
11 April 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2330909
4 October 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2212781
27 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2053864
3 April 2003 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1768348
30 January 2003 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1737607
2 October 2002 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1679306
14 November 2001 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1452874
25 September 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1458930
25 September 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1382041
4 October 1999 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1457703
2 November 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 804417
6 November 1997 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1438656
20 March 1997 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1367956
25 March 1996 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1081476
9 June 1995 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1186100
22 March 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1463164
16 August 1994 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1401910
23 March 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1472895
22 March 1993 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1148108
23 March 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 953657
22 January 1992 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 949112
21 March 1991 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 997150
23 March 1990 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1221528
27 April 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1202884
12 April 1988 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1199082
6 May 1987 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1024219
12 February 1987 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1014468
24 April 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1306857
30 April 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 983461

Deficiency record · 45

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2022 Resolved
EPIRB hydrostatic release expired APR2022. Vessel is limited to operations inside 3 miles from shore until hydrostatic release unit is replaced per manufactures specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 5 May 2022
Resolution: Received photograph of newly purchased/installed EPIRB HRU on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 May 2022 Resolved
Life Float missing (1) Paddle. Vessel to provide proper replacement. Vessel restricted to Life saving capacity of BA
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 16 May 2022
Resolution: TWO PADDLES WERE WITH THE LF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2022 Resolved
Exhaust gases must not leak from the piping or any connections. Make proper repairs to turbo exhaust flange to prevent exhaust gases from entering engine compartment. 46 CFR 182.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 16 May 2022
Resolution: EXHAUST HARDWARE ADJUSTED AND LEAK WAS STOPPED.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 May 2022 Resolved
Retroreflective tape on Life Float and BA found deteriorated. Life Float and BA retroreflective tape needs to be replaced in accordance with Q Spec 160.027 and 160.10.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 16 May 2022
Resolution: RETRO-REFLECTIVE TAPE WAS REPLACED.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 January 2022 No resolution recorded
[name withheld] THE VESSEL APPROVAL FOR A TEMPORARY REPAIR TO HULL PITTING, BY WAY OF COATING THE AFFECTED AREAS WITH BELZONA. THE AFFECTED AREAS ARE TO BE CROPPED/RENEWED AT THE CONCLUSION OF THE 2022 OPERATING SEASON.
Action required: 705 - Other - as specified
Due 31 March 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021 Resolved
Identified 03 life jackets that were damaged/worn beyond service/repair. Operator must provide a life jacket for each person carried on board the vessel. Vessel is authorized to carry 27 total persons on board until new life jackets are placed in service.
Action required: 705 - Other - as specified
Resolved 21 April 2021
Resolution: Company has purchased new Type I PFD's, properly marked and placed on vessel.
Communications › Radio Communications › EPIRB
Issued 17 April 2018 Resolved
Vessel's EPIRB Hydrostatic Release Unit (HRU) had an expiration date of March 2018. Vessel is restricted to no more than three NM from shore until the HRU is replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 19 April 2018
Resolution: Verified vessel has new HRU installed. Vessel is no longer restricted to 3nm from shore.
Construction/Loadline › Hull › Keel Plate
Issued 5 January 2017 Resolved
Submitt repair proposal to renew identified section of keel plating, shaft log, and aft water cooled bearing as discussed during hull examination. Final inspection of repairs will need to be made prior to vessel going back into the water.
Action required: 705 - Other - as specified
Resolved 25 January 2017
Resolution: Repairs have been completed and inspected by [name withheld].
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 May 2016 Resolved
Certificate of documentation(COD) needs a coastwise and fisheries endorsement(s). No other endorsements are required for the vessels operation. Provide a copy of updated COD or application for new endorsements on COD.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 27 June 2016
Resolution: Updated COD as required.
Lifesaving › Buoyant Apparatus › Marking
Issued 9 May 2012 Resolved
Retroreflective tape was worn and required replacement.
Due 15 May 2012
Resolved 15 May 2012
Resolution: New retroreflective tape installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2012 Resolved
FIrst aid kit was incomplete. Aspirin was missing; eyewash was expired.
Due 15 May 2012
Resolved 15 May 2012
Resolution: Aspirin and eyewash renewed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 May 2012 Resolved
Hydraulic steering gear line was chaffing. Install chaffing gear on affected hydraulic lines.
Due 10 June 2012
Resolved 15 May 2012
Resolution: Caffing gear installed.
Stability › Watertight Integrity › Coaming
Issued 6 April 2009 Resolved
Provide coaming 6 inches in height in way of access ladder to forward compartment, starboard side adjacent to operator station. 46 CFR 179.360 (d) (2).
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2009
Resolved 2 June 2009
Construction/Loadline › Hull › Bottom Plating
Issued 18 August 2006 Resolved
Issued CG-835 for the dry-dock 06/07 to U/T entire hull and to remove improper inserts that have been added over the years.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2007
Resolved 2 April 2007
Resolution: Vessels owners replaced the entire hull from the boot top to the keel, with sat results. After un-sat u/t results.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2006 Resolved
Properly secure transducer wire in forward compartment.
Due 21 April 2006
Resolved 18 May 2016
Resolution: Corrected at the time of inspection.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 March 2006 Resolved
Prove proper operation of the magnetic steering compass light.
Due 21 April 2006
Resolved 18 May 2016
Resolution: Corrected at the time of inspection.
Communications › Audible Communications › Horn/Whistle
Issued 20 March 2006 Resolved
Prove proper operation of the whistle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2006
Resolution: Corrected at the time of inspection.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2005 Resolved
Hang wires with metal hangers in mid-section of the vessel and mount so that the entry hatch is not obstructed.
Due 11 May 2005
Resolved 12 April 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2005 Resolved
Hang wires in engine room with metal hangers and remove fastenings/supports from fuel lines on engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 April 2005 Resolved
Repair broken captains chair mount under main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2005
Resolved 12 April 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 11 April 2005 Resolved
Demonstrate operation of sea valve from main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 April 2005 Resolved
Repair second step on boarding ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2005
Engineering › Fuel Oil Service System › Valve
Issued 11 April 2005 Resolved
Install fuel shut off valve at the engine.
Due 11 May 2005
Resolved 12 April 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 April 2005 Resolved
Properly mount magnetic compass to minimize vessel deviation.
Due 11 May 2005
Resolved 12 April 2005
Stability › Watertight Integrity › General
Issued 11 April 2005 Resolved
Plug old captains chair hole in main deck.
Due 11 May 2005
Resolved 12 April 2005
Lifesaving › Lifejacket/PFD (General)
Issued 27 April 2004 Resolved
Properly label child lifejacket stowage area. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 10 June 2004
Resolved 13 May 2004
Engineering › Electric Propulsion System
Issued 27 April 2004 Resolved
Properly cover electrical distribution panel in forward cabin. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 15 February 2005
Resolved 13 May 2004
Engineering › Fuel Oil Service System › Hose
Issued 27 April 2004 Resolved
Replace worn fuel system return line. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 10 June 2004
Resolved 8 September 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 April 2004 Resolved
Install engine exhaust lagging. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Design Flaw
Due 15 February 2005
Resolved 13 May 2004
Engineering › Bilge Water Management System › Valve
Issued 27 April 2004 Resolved
Install valves on bilge pump overboard discharge lines at hull. LEGACY COMPONENT DESC: Valve
Condition: Design Flaw
Due 15 February 2005
Resolved 12 April 2005
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 April 2004 Resolved
Remove worn plastic duct work in engine compartment and replace with non-combustible. LEGACY COMPONENT DESC: Piping (air intake)
Condition: Improper Installation
Due 15 February 2005
Resolved 13 May 2004
Lifesaving › Emergency Outfit
Issued 27 April 2004 Resolved
Replace hydrostatic release on EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2004
Resolved 13 May 2004
Engineering › Steering Gear System › Rudder Stock
Issued 3 April 2003 Resolved
RUDDER POST HAD A LOT OF TORQUE ON IT WHEN WHEEL TURNED HARD PORT OR STBD. POST HAD LOTS OF MOVEMENT AND THERE WAS WELDS THAT HAD FRACTURED IN THE PAST AS A RESULT OF THIS MOVEMENT.
Due 3 April 2003
Resolved 3 April 2003
Resolution: WELDED BRACKET ACROSS TWO VERTICLE SUPPORTS AND THE RUDDER POST.
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 April 2003 Resolved
14 LIFEJACKETS HAD STRAPS ROTTED. ONE JACKET WAS MISSING.
Due 4 April 2003
Resolved 4 April 2003
Resolution: PUT 15 NEW ADULT LIFEJACKETS ON THE VESSEL.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 October 2002 Resolved
TWO ADULT AND TWO CHILDRENS LIFE JACKETS NEEDED REPLACED DUE TO ROTTED STRAPS.
Due 2 October 2002
Resolved 2 October 2002
Resolution: RENEWED ALL BAD JACKETS.
Construction/Loadline › Structures
Issued 2 October 2002 Resolved
MAKE REPAIR PROPOSAL TO FIX HOLE IN FWD BULKHEAD IN VOID SPACE UNDER CAPTAINS CHAIR. SUBMITT PROPOSAL TO THIS OFFICE FOR APPROVAL AND MAKE REPAIRS AS APPROVED. LEGACY COMPONENT DESC: End Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2003
Construction/Loadline › Hull
Issued 2 October 2002 Resolved
FOUND CRACKED WELDS IN AREA AROUND RUDDER POST. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Resolved 30 January 2003
Construction/Loadline › Structures
Issued 2 October 2002 Resolved
Stbd side Fwd bulkhead lower area isw easted adn holed through to the next compartment. This will be addressed over the Winter lay up period. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Unknown
Due 14 March 2003
Resolved 30 January 2003
Resolution: Bulkhead inserted sat.
Lifesaving
Issued 6 November 1997 Resolved
REPAIR/REPLACE BUOYANCY APPARATUS. (APPROX. 10" GASH IN SHELL)
Condition: Unknown
Due 6 December 1997
Resolved 18 March 1998
Fire Fighting
Issued 6 November 1997 Resolved
INSTALL 01, B-II FIRE EXTINGUISHER FOR A TOTAL OF 01, B-I & 02, B-IIs.
Condition: Unknown
Due 6 December 1997
Resolved 18 March 1998
Construction/Loadline
Issued 20 March 1997 Resolved
REWELD AND STRENGTHEN CANOPY WHERE WELDS HAVE CRACKED.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Construction/Loadline
Issued 20 March 1997 Resolved
INSTALL PLATE IN DECK AT FOREPEAK TO MAKE FWD COMPT WATERTIGHT.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Construction/Loadline
Issued 20 March 1997 Resolved
CROP AND RENEW UPPER PORTION OF #1 BLKD AS NECESSARY TO MAKE WATERTIGHT.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Lifesaving
Issued 22 March 1995 Resolved
REPLACE, USING APPROVED MATERIALS AND PROCEEDURES, THE RETRO MATERIAL ON ALL ADULT LIFE JACKETS AS SPECIFIED.
Condition: Unknown
Due 23 March 1995
Resolved 13 April 1995
Engineering
Issued 24 April 1986 Resolved
INSTALL INTERLOCK SWITCH FOR VENTILATION BLOWER.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986

Casualty record · 1

21 August 2013Routine · role: Involved in a Marine Casualty · activity 4697379
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.