13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2026
No resolution recorded
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment, except that the space forward of the collision bulkhead need not be fitted with a bilge suction line when the arrangement of the vessel is such that ordinary leakage may be removed from this compartment by the use of a hand portable bilge pump or other equipment, and such equipment is provided. Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Aft center compartment does not have operational fixed bilge line and suction arrangements. Vessel to install electric bilge pump/alarm unit in aft compartment. Ensure thru hull fittings brought into use have stop/check valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2026
No resolution recorded
Each life jacket carried on board the vessel must be marked in accordance with § 185.604 of this chapter. Approx. 4 lifejackets require new stenciling. Ensure jackets have proper markings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 July 2025
Resolved
Drills not conducted in the last 90 days. Conduct drills and place in log book.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 July 2025
Resolved 8 July 2025
Resolution: Conducted underway drills during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 July 2024
Resolved
(a) The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
(b) Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel.
(c) If the cognizant OCMI determines that there is no suitable mounting surface aboard the vessel, the emergency instructions need not be posted but must be carried aboard the vessel and be available to the crew for familiarization.
Emergency instructions not on board nor posted. Post
instructions tailored to vessel's lifesaving and fire -
fighting arrangement, installations, and operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 13 August 2024
Resolution: Emergency instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 May 2024
Resolved
Keelson stringer found holed/wasted approximately 1.5 inches forward of first transverse frame convergence in most forward part of bow. 18 transverse frame members (09 frame members port side & 09 stbd) meeting bilge well/keel center are holed/wasted with length of wastage approx. 2 inches from bottom. Repair/replace wasted frames by conclusion of next winter (2024-2025) lay up period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 2 May 2025
Resolution: All frame members renewed, (18 transverse and longitudinal stringer fwd).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2023
Resolved
Each lifejacket must be marked in clearly legible block letters with the vessel's name. 02 Adult lifejackets missing vessel's name.
46CFR185.604(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 5 July 2023
Resolution: Labled life jackets
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2023
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections are not recorded in ship's logs.
46CFR176.810
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 June 2023
Resolution: Crew educated on recording inspections of fire equipment.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 July 2022
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Vessel had COD on board that expired on 30JUN2022. Obtain valid COD and have on board.
CITE
46 CFR 67.313(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Obtained vaild COD
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 July 2022
Resolved
The drill entry shall include the following information: General description of the drill scenario and training topics. Vessel logs lacked details as required in the regulations as to the nature of the drills completed. Log drills per regulations.
CITE
46 CFR 185.520(f)
46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Completed drils and logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2022
Resolved
Each life jacket must be marked with Type I retroreflective material. Found 18 life jackets with worn or missing retroreflective tape. Replace retroreflective tape.
CITE
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Replaced retroreflective tape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 July 2022
Resolved
A hatch exposed to the weather must be watertight. Hatch cover for aft compartment had multiple holes. Repair hatch cover.
CITE
46 CFR 179.360(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 6 October 2022
Resolution: Holes in the hatch cover have been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 July 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. Bilge high water level alarm did not work in forward storage compartment. Replace bilge alarm.
CITE
46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Bilge alarm replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 July 2022
Resolved
At each inspection all observed unsafe practices and other hazardous situations must be corrected. Insulation posts within machinery space were not covered. Install covers over insulation posts.
CITE
46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Caps for insulation posts installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 July 2022
Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use. Vessel's magnetic compass did not have a deviation card. Obtain deviation card.
CITE
46 CFR 184.402(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Removed magnetic compass as not required.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 July 2022
Resolved
Each abandon ship drill must, as far as practicable, be conducted as if there were an actual emergency. Vessel was able to recover man overboard during drill but had difficultly in pulling the person aboard. Following drill, discussed that there needs to be an additional system in place, such as a winch/life sling or platform or etc. Create plan for additional system to address concerns with man overboard recovery.
CITE
46 CFR 185.520(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 26 July 2022
Resolution: Created plan for additional system for man overboard recovery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2022
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across the terminals. Battery in engine room did not have a cover to protect terminals, which a temporary repair has been completed prior to completion of inspection. Vessel have plans to change out batteries and box upon completion of MSC review to electrical plans. Permanent solution to be completed following MSC approval and new installation.
CITE
46 CFR 183.05-20(a)
Action required: 705 - Other - as specified
Resolved 6 October 2022
Resolution: Discussed with owner that his battery should be covered, owner agreed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Condemned 02 adult life jackets, which were replaced prior to completion of inspection.
CITE
46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Due 6 July 2022
Resolved 6 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2022
Resolved
Number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Of the 4 child life jackets, 2 were condemned and were replaced prior to completion of inspection.
CITE
46 CFR 180.71(b)
Action required: 10 - Deficiency Rectified
Due 6 July 2022
Resolved 6 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2022
Resolved
Each floating water light must be approved in accordance with § 161.010. Water light battery did not have the installation date marked. Marking was place on light prior to the completion of inspection.
CITE
46 CFR 180.70(d)(1)
Action required: 10 - Deficiency Rectified
Due 6 July 2022
Resolved 6 July 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2022
Resolved
ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER MUST BE WATERTIGHT. THE SUITABILITY OF THE INVERTER INSTALLED ON THE WEATHERDECK CALLED INTO QUESTION. TAG OUT THIS DEVICE UNTIL IT IS MADE WATERTIGHT OR RELOCATED TO A SAFE LOCATION.
46 CFR 183.210
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2022
Resolution: Recieved email photo showing that the inverter has been removed from the vessel. Spoke with owner to convey that the inverter is not to be put in service until agreed upon by OCMI and MSC.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2021
Resolved
Repairs or alterations to the hull, machinery, or
equipment that affect the safety of the vessel must not
be made without the approval of the cognizant OCMI,
except during an emergency. Alterations that affect the
safety of the vessel include, but are not limited to
repair or replacement, other than replacement in kind of
electrical wiring, fuel lines, steering, alterations
affecting stability, etc. Owner installed AC power
inverter, as well as new 8D battery installation without
undergoing review. Submit electrical modifications to
the Marine Safety Center for review and approval.
Cite: 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 28 July 2022
Resolution: MSC has approved electrical modifications. Inverter still not approved by local OCMI and must remain tagged out until OCMI approves installation and marine grade equipment.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 19 July 2021
Resolved
Any solid ballast used to comply with this part must be
installed to the satisfaction of the [name withheld]
ballast in the form of bricks were found in the engine
compartment near the battery on starboard side. No
indication of the presence of this ballast was found on
the stability documents issued to the vessel in 2002.
Furthermore, changes to the vessel tonnage to include
the installation or removal of batteries, and the
installation of a keel cooler at an unknown time.
Stability must be verified.
Cite: 46 CFR 178.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Conducted Stability Test.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 July 2021
Resolved
The weather deck on a well deck vessel must be
watertight.Holes for drainage were drilled into the
deck on the bow, and extensive wastage was found on the
deck near the operating station.Make temporary repairs
in accordance with submitted proposal prior to COI.
Permanent repairs to be made prior to 2022
operating season.
Cite: 46 CFR 178.430 (a)
Action required: 705 - Other - as specified
Resolved 13 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2021
Resolved
An adult life jacket must be provided for each person
carried on board a vessel, in addition, a number of
child size life jackets equal to at least 10%. 05 adult
life jackets, and 04 children's life jackets a need
renewal of reflective material, name label, and/or have
tangled securing devices. Additionally, lifejacket
stowage and marking of such must be IAW 46 CFR 180.78,
or 180.25-10 and must be stowed in the upper part of the
vessel, conveniently located.
Cite: 46 CFR 180.71(a) and (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2021
Resolved
A vessel not required to have a power driven fire pump
must have at least 3 2.5 gallon buckets with an attached
lanyard placed so as to be easily available during an
emergency. The words "FIRE BUCKET" must be stenciled in
a contrasting color on each bucket.
Cite: 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 July 2021
Resolved
Flexible hose runs shall be visible, and easily
accessible. Fuel lines shall be accessible, protected
from mechanical injury, and effectively secured against excessive movement by the use of non ferrous metal
straps. The fuel return line showed beginning
indication of surface cracks and will need to be
replaced by next season. Portion of this flexible hose
in the engine room is covered by insulation. Make
visible, and inspect regularly.
Cite: 46 CFR 182.20-40 (i), & (b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 23 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 July 2021
Resolved
A vessel must carry either a first aid kit approved
under approval series 160.041 or a kit with equivalent
contents and instructions. For equivalent kits, the
contents must be stowed in a suitable watertight
container that is marked "First Aid Kit" and must be
easily visible and readily available to the crew.
Contents within the CG approved kit were incomplete.
Cite: 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 23 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2021
Resolved
A vessel must comply with the applicable requirements
for any radio installations as set forth in 47 CFR 80.
Vessel does not possess a valid FCC station license
Cite: 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 18 October 2021
Resolution: Verified FCC license.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2021
Resolved
The following items must be logged: crew training,
Abandon ship and man overboard drills and training to
include the date and general description of the scenario
and training topics, fire fighting drills and training.
Vessel log is blank, ensure that necessary training is
carried out and logged.
Cite: 46 CFR 185.420,
46 CFR 185.520,
46 CFR 185.524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 23 July 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2021
Resolved
The master of a vessel shall keep a correct, written
count of all passengers that embark on and disembark
from the vessel. Prior to departing on a voyage, the
passenger count must be communicated verbally or in
writing, and available ashore at the vessel's normal
berthing location or with a representative of the
vessel. The passenger count shall be available to the
CG upon request.
Cite: 46 CFR 185.504
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 23 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 July 2021
Resolved
All vessels must have navigation lights that are in
compliance with the navigation rules. Masthead light
screen was white, paint matte black as required.
Cite: 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 23 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 July 2021
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up to date charts, Coast Pilot, and
light list.
Cite: 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 17 August 2021
Resolution: Obtained materials and updated charts and pubs.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 July 2021
Resolved
Update VHF radios with DSC capability - see CG-CVC
policy letter 15-06(CH2).
Cite: Policy Letter
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2021
Resolved 6 July 2022
Resolution: VHF-DSC set-up and have MMSI # within.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 July 2021
Resolved
Wiring where subject to damage shall be protected.
Protect wires from chafing at operating station.
Cite: 46 CFR 183.05-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2021
Resolved 23 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 July 2021
Resolved
While onboard noticed that the mast head light was inproperly installed and not within regulation 33 CFR 83.21(a) Mastheadlight shall show unbroken light over an arc of the horizon of 225 degrees.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2022
Resolution: Recieved picture showing installation meeting requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2021
Resolved
The OCMI may require an inspection prior to the issuance of an amended Certificate of Inspection. Vessel was recently sold to new owner, who is working towards obtaining new Certificate of Inspection. Prior to operations, vessel to undergo USCG Inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2021
Resolution: Conducted COI inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019
Resolved
Replace 22 lifejackets and 04 child
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 23 April 2019
Resolution: Lifejackets were replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 March 2016
Resolved
Ring life buoy to be fitted with type II retro-reflective material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Retroflective tape installed appropriately.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 March 2016
Resolved
Jacket Water discharge line is chafed and worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Hose installed and witnessed under operating pressure. Sat.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 24 March 2016
Resolved
Forward motor mount has become loose over time.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Motor mount tightened and new lock washer installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2016
Resolved
First aid kit requires renewal per 46 CFR Subchapter Q required items list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 15 April 2016
Resolution: Updated satisfactorily.