Records from 1995 to 2006. Most recent: operational control imposed, 29 September 2006.
Inspection history · 27
29 September 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2789794
29 September 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2790071
22 May 2006
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2654958
10 January 2006
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2564223
3 January 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2560009
8 December 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2255552
22 November 2004
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2245840
11 March 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1493185
14 November 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 295357
17 June 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290964
19 March 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 288371
16 March 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 288243
24 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 507064
25 September 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 282566
29 November 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274390
29 November 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 435229
15 September 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 432711
17 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426496
28 January 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 425058
8 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 420195
1 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417652
11 July 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 405657
7 February 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 400025
8 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392961
16 April 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 389731
21 February 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 387842
12 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 379281
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 10 January 2006
Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System while transiting into the Port of Brunswick, Ga.
Condition: Unknown
Due 10 January 2006
Resolved 10 January 2006
Resolution: Issued LOW
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 January 2006
Resolved
Fireman outfits are worn beyond repair and must be replaced. Class must clear deficiency.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2006
Resolution: Received proper documentation from vessel satisfying requirement.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 November 2004
Resolved
Around the main electrical distribution panel and all other 440V panels they are missing the approved switchboard matting.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 December 2004
Resolved 7 December 2004
Resolution: Approved switchboard matting has been purchased and placed around electrical panels.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 November 2004
Resolved
The crew has not been maintaining the sewage unit as per the manufacturer's requirements. They are missing a chloriene test kit and tablets. They have not been inspecting the unit daily, weekly, monthly etc. as required.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 December 2004
Resolved 7 December 2004
Resolution: The operator has added the manufacturer''s service requirements to the ships maintenance procedures.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 22 November 2004
Resolved
The bridge letter between the Owner and Charterer is not on board. Reference 33 CFR 138.100.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2004
Resolved 23 November 2004
Resolution: Bridge Letter received.
Operations/Management › Pollution
Issued 11 March 2002
Resolved
Vessel does not have bunkering procedures, which address specifics of tank-to-tank transfers, or transfers to and from the vessel as required by 33 C.F.R. 155.720. LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 11 March 2002
Resolved 12 March 2002
Resolution: Received new bunkering procedures that meet the requirement of 33 C.F.R. 155.720.
Operations/Management › Pollution
Issued 11 March 2002
Resolved
Vessel does not have bunkering procedures that address specifics on this vessel as required in 33 C.F.R. 155.750. LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 11 March 2002
Resolved 12 March 2002
Resolution: Received new bunkering procedures that meet the requirements of 33 C.F.R. 155.750.
Operations/Management › Pollution
Issued 11 March 2002
Resolved
Vessel did not have transfer procedures available for inspection by USCG as required by 33 C.F.R. 155.740. LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 12 March 2002
Resolved 12 March 2002
Resolution: Received new bunkering procedures via fax that meet the requirement.
Operations/Management › Pollution
Issued 11 March 2002
Resolved
Vessel has not tested bunkering line to one and a half times the maximum allowable working pressure within the last year as required by 33 C.F.R. 156.170. LEGACY COMPONENT DESC: Compliance with Transfer Procedures
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 11 March 2002
Resolved 12 March 2002
Resolution: Received pressure test from outside source testing the bunkering line to 6.4 kg.
Operations/Management › Pollution
Issued 11 March 2002
Resolved
Prior to conducting bunkering operations in U.S. waters, vessel is to provide approved bunkering and transfer procedures specific to this vessel and products being transferred. Compliance with items 1-4 of this inspection to USCG. 33 C.F.R. 155.760 LEGACY COMPONENT DESC: Removal Methods/Procedures
Action required: 703 - Prior to bunkering operations
Due 12 March 2002
Resolved 12 March 2002
Resolution: Received new bunkering procedures that meet the requirement.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 14 November 2001
Resolved
UPDATE BUNKER OIL TRANSFER PROCEDURES TO REFLECT TOPPING OFF METHODS IN ACCORDANCE WITH 33 CFR 155.750. CORRECT PRIOR TO NEXT U.S PORT AFTER SAILING FOREIGN
Condition: Unknown
Due 14 December 2001
Resolved 11 March 2002
Resolution: Cleared and reissued deficiency.
Lifesaving
Issued 19 March 2001
Resolved
Install screens on lube oil and fuel oil on deck vents
Condition: Unknown
Due 5 May 2001
Resolved 9 April 2001
Construction/Loadline
Issued 25 September 2000
Resolved
VESSEL'S OILY WATER SEPERATOR CONCENTRATION DETECTOR IS NOT OPERATING PROPERLY.
Condition: Unknown
Due 17 June 2001
Resolved 17 June 2001
Lifesaving
Issued 25 September 2000
Resolved
AUTO LOWERING DEVICES' CABLE IS TOO LONG TO BE LOWERED FROM INSIDE.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Lifesaving
Issued 25 September 2000
Resolved
VESSELS FALL CABLES ARE NOT ADJUSTED PROPERLY.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Fire Fighting
Issued 15 September 1999
Resolved
MAKE THE DOOR FROM THE ENGINE ROOM TO THE MAIN DECK IN THE WAY OF THE LADDER TO STEERING ROOM SELF CLOSING AS ORIGINAL. SOLAS 74 AMD II-2/47
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 28 January 1999
Resolved
UNSERVICABLE BRIDGE WING RING BOUY._x001C_ _x001C_ _x001C_ REPAIR OR REPLACE LIFE RING BOUY AS PER SOLAS 74 AMENDED CH.III REG 31.7
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Documentation
Issued 28 January 1999
Resolved
INCOMPLETE OIL TRANSFER PROCEDURES. NOT INCOMPLIANCE WITH 33 CFR 155.750_x001C_ _x001C_ _x001C_ HAVE PROPER OIL TRANSFER PROCEDURES PRIOR TO BUNKERING IN THE U.S.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Lifesaving
Issued 1 July 1998
Resolved
STARBOARD LIFEBOAT WINCH CONTROL BOX WAS INOPERATIVE, VESSEL HAD TO BE RAISED MANUALLY. VESSEL IS REQUIRED TO REPAIR PRIOR TO 31JUL98.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Documentation
Issued 21 February 1996
Resolved
FIRE CONTROL PLAN IS A BLACK AND WHITE DRAWING THAT DOES NOT SHOW COLOR CODED SOLAS SYMBOLOGY. MSC RESOLUTION A.654(16) OF IMO.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996