MAURY USCG vessel records
← All vessels

EXPLORER

EXPLORER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 48 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
1995
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

425401
Flag
UNITED STATES
Maury page id
psix-425401

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE INC · MONTICELLO, AZ, UNITED STATES · built 1995
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

26 May 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8383472
23 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8300738
2 June 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8150163
30 April 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7904191
13 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7865081
9 May 2023 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7684758
11 May 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7448572
3 February 2022 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7386577
27 April 2021 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7179317
25 February 2021 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7145728
10 June 2020 Administrative Inspection · DAPI Audit · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6960919
10 June 2019 Deficiency Check · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6703214
26 February 2019 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6634124
30 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6444325
12 March 2018 DAPI Audit · Internal Structural Exam · Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6368895
17 February 2017 Internal Structural Exam · DAPI Audit · Deficiency Check · Hull Examination · Examination of Repairs · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6087738
4 May 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5868977

Deficiency record · 48

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Vessel required to be equipped with a suitable steering arrangement. Existing tie bar end links were found worn, requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Electrical conductors shall be protected from the weather. Existing battery conductor(s) outer jacketing is damaged/pre-maturely worn from exposure to UV light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Conductors are required to be supported with metallic supports spaced not more than 24" apart. Existing metallic supports are corroded/wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2022 Resolved
During a DD/Hull Inspection, all accessible parts of the vessels underwater body shall be made available for inspection. Existing mounting hardware between sponsons & cross deck structure (transverse) were found loose (isolated).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2022
Resolved 3 February 2022
Resolution: Attending Inspector(s) witnessed the crew tighten all mounting hardware.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 February 2022 Resolved
An internal structural examination shall include the examination of all accessible voids. Attending Inspector(s) called out watertight hatch gaskets for (all) voids due to age/deterioration (cracked).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 February 2021 Resolved
An internal structural examination consists of examining the vessels main strength members, including framing, hull plating and voids. Attending Inspector called out fractured weldment IWO starboard void #2 watertight bulkhead (centerline/upper).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 27 April 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 February 2021 Resolved
An internal structural examination consists of examining the vessels main strength members, including framing, hull plating and voids. Attending Inspector called out fractured/wasted transverse transom beam IWO starboard void #4 (upper)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 27 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2021 Resolved
Vessel is required to be equipped with a suitable steering arrangement. Existing steering system has worn components IWO starboard outboard motor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 27 April 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2020 Resolved
Vessel required to be equipped with emergency lighting. Vessels lighting fixtures IWO main deck canopy (centerline) were missing lens covers and bulbs were extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of protective lens covers for overhead lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
Vessels name required to be marked on ring life buoys. Existing markings on ring life buoy were faded/worn/missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified renewal of markings for ring life buoy.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2020 Resolved
Vessel required to be fitted with emergency lighting. Existing lighting conductors were not installed with proper connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified electrical connections IWO overhead lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020 Resolved
Conductors in power & lighting circuits shall be at least No. 14AWG or larger. Existing conductors for between batteries and bus bar are deteriorated (UV) and require replacement. Temporary installation of split loom is authorized until next scheduled Hull/DD inspection where conductors shall be replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of protective cover for electrical conductors (DC) for batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020 Resolved
Vessels hatches are required to be made watertight. Existing hatch IWO Starboard Void #1 (@ Operators Station) was not capable of being made watertight due to seized handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified repairs/adjustments made to wateright hatch cover/dogging assembly IWO void #1.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2020 Resolved
Attending Inspector(s) shall ensure vessel is fit for route and service intended. Vessels mast assembly missing backing hardware (washers).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of hardware for mast assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
Vessels ring life buoy is required to be fitted with a lifeline wih corrosion resistant clip. Existing clip requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified renewal of corrosion resistant clip for ring life buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) identified fractured weldment in way of port quarter side shell @ transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way of upper transom plating where upper mounting hardware for outboard motors were installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO transom.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way of port & starboard mounting brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO port/starboard moutning brackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way support/mounting brackets for sewage & fresh water tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO MSD/Fresh Water Tank mounting/support brackets.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted deteriorated flexible hose connection between starboard toilet and sewage holding tank (exterior/between pontoons).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of flexible hose between installed toilet and holding tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Attending Inspector(s) noted UV deterioration on port & starboard main engines fuel lines between fuel filter and outboard motor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of flexible fuel hose assemblies between fuel filter(s) and main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/deterioration of fuel filter elements, port & starboard sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of fuel filter elements for main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment for ladder assembly (inboard/lower) in way of starboard void #1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #1 ladder assembly.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment in way of bottom longitudinal/fwd bulkhead of port void #2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO port void #2.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted that the watertight bulkheads in way of port void #2, port void #3 and starboard void #3 were not watertight due to peripheral framing being stitch welded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified corrections made to watertight bulkhead weldments. Witnessed satisfactory air test.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment along vertical stiffener in way of port & starboard voids #3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #3.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment in way of transverse box beam in way of starboard void #4 along transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #4.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 April 2018 Resolved
Crop/renew fractured longitudinal frame & transverse frame IWO starboard void #1.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 10 June 2020
Resolution: Attending Inspector verified repairs made to longitudinal framing IWO starboard void #1.
Construction/Loadline › Structures › Superstructure
Issued 20 March 2018 Resolved
Attending Inspector(s) called out fractured weldment IWO port canopy framing IVO port fwd PFD deckbox.
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified repairs made IWO port canopy framing (re-welded).
Construction/Loadline › Hull › Weld
Issued 13 March 2018 Resolved
Grind/re-weld fractured weldments IWO Port Void #1, Starboard Void #1 & Port Void #4 (transom).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2018
Resolution: Attending Inspector(s) verified repairs to fractured weldments IWO Port Voids #1/4 & Starboard Void #1.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 March 2018 Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Navigation › Piloting/Steering › Marine Charts
Issued 12 March 2018 Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 March 2018 Resolved
Vessel did not carry the original Certificate of Documentation on board.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of original COD on board.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 March 2018 Resolved
Proof of enrollment letter was not current/up to date (list of employees/random pool)
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) reviewed current proof of enrollment letter for maritime consortium.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 March 2018 Resolved
One adult Type I PFD was condemnded due to condition (un-serviceable).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified replacement of one Type I PFD.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 March 2018 Resolved
Type III MSD system not equipped with operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified the posting of operating instructions for installed Type III MSD.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 March 2018 Resolved
Vessel not equipped with required qty of hand flashlights.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 11 April 2018
Resolution: Attending Inspector(s) verified carriage of two (2) flashlights.
Documentation › Markings/Placards › Warning Signs
Issued 12 March 2018 Resolved
Vessels markings for emergency escapes were incomplete/required re-stenciling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified presence of emergency escape markings.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 March 2018 Resolved
Company does not have EAP (policy/training) in place.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified EAP Policy.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 March 2018 Resolved
Vessels crew not properly trained in First Aid/CPR (50% of crew).
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified CPR/First Aid training.
Construction/Loadline › Hull › Hull Plating
Issued 17 February 2017 Resolved
Port sponson holed in way of stem.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified repairs made to port sponson @ stem.
Construction/Loadline › Hull › Transverse Frame
Issued 17 February 2017 Resolved
Transverse stiffener in way of starboard sponson @ transom fractured.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified repairs made in way of starboard aft transverse frame along the transom.
Navigation › Piloting/Steering › Marine Charts
Issued 17 February 2017 Resolved
Provide current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 February 2017 Resolved
Provide current/up to date navigational publications (Coast Pilot [name withheld], etc)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 February 2017 Resolved
Renew worn/deteriorated retro-reflective material on Type I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified repairs to retro-reflective tape/markings on Type I PFD's.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 February 2017 Resolved
Conduct required drills/exercises (man overboard, fire, abandon ship)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector conducted u/w drills/exercises with crew.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 17 February 2017 Resolved
Conduct operational test of steering/propulsion system.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector performed operational testing of the vessels steering/propulsion systems.
Construction/Loadline › Hull › Side Shell
Issued 17 February 2017 Resolved
Remove stainless steel fastener in way of starboard sponson @ transom and reweld.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified repairs made IO starboard sponson @ transom.

Ownership record