MAURY USCG vessel records Sign in
← All vessels

EXPLORER

EXPLORER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1995, most recently in May 2026, along with 94 deficiencies.

Records from 1995 to 2026. Most recent: inspection, 26 May 2026.

Built
1995
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

425401
Flag
UNITED STATES
367059320 (licence lapsed)
Maury page id
psix-425401

Inspections, by type

…with no type recorded5
Years with a record 28 calendar years (1995–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE INC · MONTICELLO, AZ, UNITED STATES · built 1995
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC6663MMSI 367059320 · expired · voluntarily equipped · granted 2 August 2005, cancelled 3 October 2015
WCT3496MMSI not assigned · expired · voluntarily equipped · granted 14 July 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

26 May 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8383472
23 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8300738
2 June 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8150163
30 April 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7904191
13 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7865081
9 May 2023 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7684758
11 May 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7448572
3 February 2022 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7386577
27 April 2021 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7179317
25 February 2021 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7145728
10 June 2020 Administrative Inspection · DAPI Audit · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6960919
10 June 2019 Deficiency Check · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6703214
26 February 2019 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6634124
30 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6444325
12 March 2018 DAPI Audit · Internal Structural Exam · Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6368895
17 February 2017 Internal Structural Exam · DAPI Audit · Deficiency Check · Hull Examination · Examination of Repairs · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6087738
4 May 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5868977
1 February 2011 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3937858
17 September 2010 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3858681
4 May 2009 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3467684
9 March 2009 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3434041
2 June 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3245412
28 February 2008 Inclining Experiment
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3158132
12 June 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2959034
30 May 2007 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2946313
15 February 2007 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2872426
23 May 2006 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2656644
14 February 2005 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2297096
10 July 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2128053
4 May 2004 Type not recorded
No type recorded · GROUP CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2059139
19 April 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2047676
12 April 2004 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2047597
9 February 2004 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2005209
2 June 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1808453
31 January 2003 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1738044
29 April 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1611188
4 June 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1399633
8 February 2001 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1418831
28 April 2000 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 817292
16 March 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1413680
27 January 2000 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1376032
27 May 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1369186
10 August 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1131307
8 June 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 792487
30 January 1998 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1441339
2 June 1997 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1109618
13 August 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1090105
16 July 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1089360
20 June 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1079860
9 August 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1189389
30 June 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 876770
12 June 1995 Initial Certification · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1190959

Deficiency record · 94

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Vessel required to be equipped with a suitable steering arrangement. Existing tie bar end links were found worn, requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Electrical conductors shall be protected from the weather. Existing battery conductor(s) outer jacketing is damaged/pre-maturely worn from exposure to UV light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
Conductors are required to be supported with metallic supports spaced not more than 24" apart. Existing metallic supports are corroded/wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2022 Resolved
During a DD/Hull Inspection, all accessible parts of the vessels underwater body shall be made available for inspection. Existing mounting hardware between sponsons & cross deck structure (transverse) were found loose (isolated).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2022
Resolved 3 February 2022
Resolution: Attending Inspector(s) witnessed the crew tighten all mounting hardware.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 February 2022 Resolved
An internal structural examination shall include the examination of all accessible voids. Attending Inspector(s) called out watertight hatch gaskets for (all) voids due to age/deterioration (cracked).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 February 2021 Resolved
An internal structural examination consists of examining the vessels main strength members, including framing, hull plating and voids. Attending Inspector called out fractured weldment IWO starboard void #2 watertight bulkhead (centerline/upper).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 27 April 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 February 2021 Resolved
An internal structural examination consists of examining the vessels main strength members, including framing, hull plating and voids. Attending Inspector called out fractured/wasted transverse transom beam IWO starboard void #4 (upper)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 27 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2021 Resolved
Vessel is required to be equipped with a suitable steering arrangement. Existing steering system has worn components IWO starboard outboard motor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2021
Resolved 27 April 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2020 Resolved
Vessel required to be equipped with emergency lighting. Vessels lighting fixtures IWO main deck canopy (centerline) were missing lens covers and bulbs were extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of protective lens covers for overhead lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
Vessels name required to be marked on ring life buoys. Existing markings on ring life buoy were faded/worn/missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified renewal of markings for ring life buoy.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2020 Resolved
Vessel required to be fitted with emergency lighting. Existing lighting conductors were not installed with proper connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified electrical connections IWO overhead lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020 Resolved
Conductors in power & lighting circuits shall be at least No. 14AWG or larger. Existing conductors for between batteries and bus bar are deteriorated (UV) and require replacement. Temporary installation of split loom is authorized until next scheduled Hull/DD inspection where conductors shall be replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of protective cover for electrical conductors (DC) for batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020 Resolved
Vessels hatches are required to be made watertight. Existing hatch IWO Starboard Void #1 (@ Operators Station) was not capable of being made watertight due to seized handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified repairs/adjustments made to wateright hatch cover/dogging assembly IWO void #1.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2020 Resolved
Attending Inspector(s) shall ensure vessel is fit for route and service intended. Vessels mast assembly missing backing hardware (washers).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified installation of hardware for mast assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
Vessels ring life buoy is required to be fitted with a lifeline wih corrosion resistant clip. Existing clip requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 September 2020
Resolution: Attending Inspector(s) verified renewal of corrosion resistant clip for ring life buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) identified fractured weldment in way of port quarter side shell @ transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way of upper transom plating where upper mounting hardware for outboard motors were installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO transom.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way of port & starboard mounting brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO port/starboard moutning brackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/pitting in way support/mounting brackets for sewage & fresh water tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO MSD/Fresh Water Tank mounting/support brackets.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted deteriorated flexible hose connection between starboard toilet and sewage holding tank (exterior/between pontoons).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of flexible hose between installed toilet and holding tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Attending Inspector(s) noted UV deterioration on port & starboard main engines fuel lines between fuel filter and outboard motor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of flexible fuel hose assemblies between fuel filter(s) and main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted wastage/deterioration of fuel filter elements, port & starboard sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified renewal of fuel filter elements for main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment for ladder assembly (inboard/lower) in way of starboard void #1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 10 June 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #1 ladder assembly.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment in way of bottom longitudinal/fwd bulkhead of port void #2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO port void #2.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 February 2019 Resolved
Attending Inspector(s) noted that the watertight bulkheads in way of port void #2, port void #3 and starboard void #3 were not watertight due to peripheral framing being stitch welded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 9 January 2020
Resolution: Attending Inspector(s) verified corrections made to watertight bulkhead weldments. Witnessed satisfactory air test.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment along vertical stiffener in way of port & starboard voids #3.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #3.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 February 2019 Resolved
Attending Inspector(s) noted fractured weldment in way of transverse box beam in way of starboard void #4 along transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 7 March 2019
Resolution: Attending Inspector(s) verified repairs made IWO starboard void #4.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 April 2018 Resolved
Crop/renew fractured longitudinal frame & transverse frame IWO starboard void #1.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 10 June 2020
Resolution: Attending Inspector verified repairs made to longitudinal framing IWO starboard void #1.
Construction/Loadline › Structures › Superstructure
Issued 20 March 2018 Resolved
Attending Inspector(s) called out fractured weldment IWO port canopy framing IVO port fwd PFD deckbox.
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified repairs made IWO port canopy framing (re-welded).
Construction/Loadline › Hull › Weld
Issued 13 March 2018 Resolved
Grind/re-weld fractured weldments IWO Port Void #1, Starboard Void #1 & Port Void #4 (transom).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2018
Resolution: Attending Inspector(s) verified repairs to fractured weldments IWO Port Voids #1/4 & Starboard Void #1.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 March 2018 Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Navigation › Piloting/Steering › Marine Charts
Issued 12 March 2018 Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 March 2018 Resolved
Vessel did not carry the original Certificate of Documentation on board.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified carriage of original COD on board.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 March 2018 Resolved
Proof of enrollment letter was not current/up to date (list of employees/random pool)
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) reviewed current proof of enrollment letter for maritime consortium.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 March 2018 Resolved
One adult Type I PFD was condemnded due to condition (un-serviceable).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified replacement of one Type I PFD.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 March 2018 Resolved
Type III MSD system not equipped with operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified the posting of operating instructions for installed Type III MSD.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 March 2018 Resolved
Vessel not equipped with required qty of hand flashlights.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 11 April 2018
Resolution: Attending Inspector(s) verified carriage of two (2) flashlights.
Documentation › Markings/Placards › Warning Signs
Issued 12 March 2018 Resolved
Vessels markings for emergency escapes were incomplete/required re-stenciling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified presence of emergency escape markings.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 March 2018 Resolved
Company does not have EAP (policy/training) in place.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified EAP Policy.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 March 2018 Resolved
Vessels crew not properly trained in First Aid/CPR (50% of crew).
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 10 April 2018
Resolution: Attending Inspector(s) verified CPR/First Aid training.
Construction/Loadline › Hull › Hull Plating
Issued 17 February 2017 Resolved
Port sponson holed in way of stem.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified repairs made to port sponson @ stem.
Construction/Loadline › Hull › Transverse Frame
Issued 17 February 2017 Resolved
Transverse stiffener in way of starboard sponson @ transom fractured.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified repairs made in way of starboard aft transverse frame along the transom.
Navigation › Piloting/Steering › Marine Charts
Issued 17 February 2017 Resolved
Provide current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 February 2017 Resolved
Provide current/up to date navigational publications (Coast Pilot [name withheld], etc)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 February 2017 Resolved
Renew worn/deteriorated retro-reflective material on Type I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified repairs to retro-reflective tape/markings on Type I PFD's.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 February 2017 Resolved
Conduct required drills/exercises (man overboard, fire, abandon ship)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector conducted u/w drills/exercises with crew.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 17 February 2017 Resolved
Conduct operational test of steering/propulsion system.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector performed operational testing of the vessels steering/propulsion systems.
Construction/Loadline › Hull › Side Shell
Issued 17 February 2017 Resolved
Remove stainless steel fastener in way of starboard sponson @ transom and reweld.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 22 May 2017
Resolution: Attending Inspector verified repairs made IO starboard sponson @ transom.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 September 2010 Resolved
Move side lights to a position where they can be seen IAW NAVRULES. Stbd light was covered by plastic canvas and could not be seen from the front on the boat. Operator will leave canvas covering off until the lights can be moved.
Action required: 705 - Other - as specified
Resolved 23 September 2010
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 September 2010 Resolved
Provide copy of NAVRULES onboard
Action required: 705 - Other - as specified
Resolved 23 September 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2010 Resolved
Vessel was in operation carrying passengers past the 90 day window on the COI anniversary date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2010
Resolution: Annual inspection conducted. Issued LOW.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 May 2009 Resolved
Provide Bracket for fire extinguisher (stern).
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 May 2009 Resolved
Provide light for magnetic compass.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 May 2009 Resolved
Conduct successful man over board drill.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Operations/Management › Drug and Alcohol Testing › MRO Drug Free Certificates
Issued 4 May 2009 Resolved
Fax Drug Consortium enrollment cards and deck log to office.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 4 May 2009 Resolved
Prove proper operation of engines.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Construction/Loadline › Hull › Hull Plating
Issued 9 March 2009 Resolved
Repair 12 cracked welds.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Cracked welds have been repaired.
Construction/Loadline › Hull › Weld
Issued 9 March 2009 Resolved
Fix crack on weld on inspection hatch in port compartment 3.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Weld on inspection hatch in port copartment 3 has been repaired.
Engineering › Steering Gear System › Linkage
Issued 9 March 2009 Resolved
Replace steering tie rod link.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Steering tie rod link has been replaced.
Engineering › Electric Propulsion System › Wiring
Issued 9 March 2009 Resolved
Provide metal brackets for wiring every 24 inches.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Metal brackets have been provided and properly installed.
Engineering › Fuel Oil Service System › Ventilation
Issued 9 March 2009 Resolved
Properly install fuel tank flame screen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Fuel tank flame screen has been properly installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 15 February 2007 Resolved
Replace worn hose on forward sewage tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2007
Resolution: Installed new hose.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 15 February 2007 Resolved
Properly install vent tubing for sewage holding tanks to prevent overboard discharge.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 1 March 2007
Resolution: rerouted vent tubing to ensure no discharge.
Construction/Loadline › Hull › Weld
Issued 14 February 2005 Resolved
Weld cracked stbd side IVO underside of engine mount. Crack visible by entering most aft compartment thru restroom and looking aft toward engine.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 February 2005
Resolution: Grounded weld and re-welded.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 April 2004 Resolved
Ten (10) adult PFD's and four (4) child PFD's required new reflective tape. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Resolved 12 April 2004
Resolution: Replaced tape
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 April 2004 Resolved
Add additional donning placard at port PFD storage area and at aft PFD storage area.
Action required: 705 - Other - as specified
Resolved 12 April 2004
Resolution: Donning placards mounted
Documentation › Manuals/Policy Documentation
Issued 2 June 2003 Resolved
Provide proper training log and log entries LEGACY COMPONENT DESC: Training Manual (lifesaving)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: deficiency corrected satisfactorily
Navigation › Collision/Grounding Avoidance
Issued 2 June 2003 Resolved
Replace or provide proper side light covers LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: deficiency corrected satisfactorily
Engineering › Fuel Oil Service System
Issued 2 June 2003 Resolved
Properly Label fuel shut off valves LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: deficiency corrected satisfactorily
Fire Fighting › Miscellaneous Items
Issued 2 June 2003 Resolved
Properly label fire buckets
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: deficiency corrected satisfactorily
Construction/Loadline › Hull
Issued 4 February 2003 Resolved
Inboard side of each outboard motor transom cracked where it meets the hull. (Issued deficiency as a worklist item)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2003
Resolved 12 February 2003
Construction/Loadline › Hull
Issued 4 February 2003 Resolved
Replace wasted angle bracket located under the vessel stbd aft just fwd of the MSD tank. (Issued deficiency as a worklist item)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2003
Resolved 12 February 2003
Construction/Loadline › Structures
Issued 4 February 2003 Resolved
Overhead canvas frame coming apart stbd side amidship. Just needs to be slipped back into place. (Issued deficiency as worklist item)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2003
Resolved 14 February 2003
Construction/Loadline
Issued 8 February 2001 Resolved
Gouge and reweld inboard seam on forward port pontoon, as marked, in way ofarea where vsl grounds on beach to offload passengers.
Condition: Unknown
Due 12 March 2001
Resolved 14 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Gouge and reweld inboard seam on forward stbd pontoon, as marked, in way ofarea where vessel grounds to offload passengers.
Condition: Unknown
Due 12 March 2001
Resolved 14 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Make proposal and conduct proper crack repair and/or metal insert on stbd pontoon in way of area where vessel grounds to offload passengers.
Condition: Unknown
Due 12 March 2001
Resolved 14 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Gouge and reweld cracked welds on port side aft deck as marked below railing.
Condition: Unknown
Due 12 March 2001
Resolved 14 March 2001
Electrical
Issued 8 February 2001 Resolved
Replace aft centerline below-deck wire clamps.
Condition: Unknown
Due 12 March 2001
Resolved 14 March 2001
Navigation
Issued 16 March 2000 Resolved
REPLACE LOCKING NUTS ON BOTH OUTBOARD ENGINES ON STERRING RODS.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Electrical
Issued 16 March 2000 Resolved
REPAIR ALL LIGHTS IN PASSAWAY PASSENGER COMPARTMENT, VESSEL RESTRICTED TO DAYLIGHT OPERATIONS ONLY.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Fire Fighting
Issued 27 May 1999 Resolved
REPLACE RUSTED B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 27 May 1999 Resolved
OBTAIN 3 NEW RED HAND FLARES AND 3 NEW ORANGE SMOKE FLARES.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Electrical
Issued 27 May 1999 Resolved
REPLACE BURNED OUT LIGHT BULBS IN MAIN CABIN.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 27 May 1999 Resolved
OBTAIN FIRST AID AND CPR CERTIFICATION FOR AT LEAST 50% OF THE CREW._x001C_
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Documentation
Issued 27 May 1999 Resolved
DESIGNATE, IN WRITING, A SENIOR DECK HAND FOR THE VESSEL.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Engineering
Issued 8 June 1998 Resolved
REPLACE STARBOARD OURBOARD FUEL HOSE NO LATER THAN 08JUL98.
Condition: Unknown
Due 8 June 1998
Resolved 8 June 1998
Documentation
Issued 20 June 1996 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Lifesaving
Issued 20 June 1996 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS WITH USCG INSPECTOR ABOARD.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Engineering
Issued 20 June 1996 Resolved
PROVIDE CHAFE GUARD FOR PORT FUEL HOSE.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Lifesaving
Issued 20 June 1996 Resolved
RELABEL LIFE PRESERVER STORAGE LOCKERS TO ACCURATELY REFLECT ACTUAL STOWAGENUMBERS AND SIZES.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Lifesaving
Issued 20 June 1996 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR THE LIFE RING.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
PROVIDE TWO FLASHLIGHTS FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 30 June 1995 Resolved
MAKE PERMANENT ACCESS INTO FORWARD PORT SPONSON IN ACCORDANCE WITH 46 CFR 176.10-5.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995
Lifesaving
Issued 30 June 1995 Resolved
MAKE STORAGE FOR ADULT/CHILDRENS LIFE PRESERVERS IN ACCORDANCE WITH 46 CFR 185.30-10.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.