Records from 1995 to 2003. Most recent: inspection, 2 September 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
2 September 2003
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1766865
3 February 2003
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1838826
3 September 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1670183
28 August 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1668119
2 August 2002
In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664469
26 June 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1637381
8 April 2002
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1602282
12 October 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074541
5 October 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 177244
29 June 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403431
1 June 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066265
14 April 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 85037
27 February 2001
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459685
10 January 2001
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1057728
21 May 1999
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 799566
2 May 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1391190
15 March 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1404737
27 May 1998
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 791643
12 March 1998
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1471816
12 March 1997
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1392676
13 March 1996
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1082634
25 May 1995
Initial Certification · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 874687
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 22 May 2003
Resolved
Review narrative for outstanding items and issues. This vessel has a deactivated COI and needs to complete an Annual Inspection and Credit Dry Dock Examination.
Due 22 May 2003
Resolved 22 February 2005
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 8 April 2003
Resolved
Provide information requested by MSO Tampa for engine hatch closure. LEGACY COMPONENT DESC: Hatch Closure Device
Condition: Design Flaw
Due 8 April 2003
Resolved 22 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 April 2003
Resolved
Have all extinguishers inspected or prove certification. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 22 May 2003
Engineering › Gasoline Engine (propulsion)
Issued 8 April 2003
Resolved
Repair and prove proper operation of both vapor detection system. LEGACY COMPONENT DESC: Ventilation
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 22 May 2003
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 2003
Resolved
Replace the AFT seal on the FWD shaft housing. LEGACY COMPONENT DESC: Shaft Seal
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 22 February 2005
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 April 2003
Resolved
Complete your annual inspection. LEGACY COMPONENT DESC: Annual Inspection
Due 8 April 2003
Resolved 22 February 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 8 April 2003
Resolved
Label high bilge level alarm system. LEGACY COMPONENT DESC: Label
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 22 February 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 April 2003
Resolved
Provide a copy of operators licenses. LEGACY COMPONENT DESC: Copy of masters licenses
Due 8 April 2003
Resolved 22 February 2005
Electrical › Electric Supply System (service) › Cable
Issued 8 April 2003
Resolved
Remove all dead-ended wires and ensure all wires are properly installed.
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 22 February 2005
Construction/Loadline › Hull
Issued 8 April 2003
Resolved
Properly repair the welded crack in way of the FWD shaft tube housing as discussed. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper Installation
Due 8 April 2003
Resolved 22 May 2003
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 April 2003
Resolved
Provide a copy of passenger orientation as per MSO Tampa Memo No 9-99.
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 22 February 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 April 2003
Resolved
Provide a copy of the maintenance sched as per memo 9-99. LEGACY COMPONENT DESC: Maintenance Schedule
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 22 February 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 April 2003
Resolved
Provide a copy of the operational standards as per Tampa memo 9-99. LEGACY COMPONENT DESC: Operational standards
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 22 February 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 April 2003
Resolved
Provide a copy of the emergency response plan. LEGACY COMPONENT DESC: Emergency Response Plan
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 22 February 2005
Engineering › Shafting/Propeller Arrangements
Issued 26 June 2002
Resolved
Replace shaft bearings.
Condition: Improper/Lack of Maintenance
Due 16 July 2002
Resolved 26 June 2002
Engineering › Gasoline Engine (propulsion)
Issued 26 June 2002
Resolved
Clean carburetor.
Condition: Improper/Lack of Maintenance
Due 26 June 2002
Resolved 26 June 2002
Fire Fighting
Issued 26 June 2002
Resolved
Provide three fire buckets w/markings IAW 46CFR181.610. LEGACY COMPONENT DESC: Fire Buckets
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 28 August 2002
Lifesaving › Hand Flares
Issued 26 June 2002
Resolved
Provide a portable watertight container w/markings for flares IAW 46CFR185.614.
Condition: Improper Installation
Due 15 July 2002
Resolved 28 August 2002
Accommodation/Occupational Safety › Ventilation
Issued 26 June 2002
Resolved
Provide ventilation exhaust blower motors IAW 46CFR182.460(c).
Condition: Improper Installation
Due 26 July 2002
Resolved 28 August 2002
Accommodation/Occupational Safety › Ventilation
Issued 26 June 2002
Resolved
Provide a proper ventilation system IAW 46CFR182.460. (Duct work is not proper)
Condition: Improper Installation
Due 26 July 2002
Resolved 28 August 2002
Engineering
Issued 26 June 2002
Resolved
Provide visual lights for each bilge high level alarm IAW 46CFR182.530. (4 Total) LEGACY COMPONENT DESC: High Bilge Level Alarm System
Condition: Improper Installation
Due 30 September 2002
Resolved 8 April 2003
Pollution Prevention/Response
Issued 8 April 2002
Resolved
Clean bilges of all foreign debris and oil.
Condition: Improper/Lack of Maintenance
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Personnel › Certificates/Documents/Licenses
Issued 8 April 2002
Resolved
Provide list of all employees.
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 8 April 2002
Resolved
Provide copy of all CPR/First Aid card.
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 April 2002
Resolved
Provide copy of all captains license.
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 8 April 2002
Resolved
Post sign for engine room exhaust ventilation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 8 April 2002
Resolved
Provide proof of employees pre-employment testing.
Due 15 April 2002
Resolved 15 April 2002
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 8 April 2002
Resolved
Provide proof of random testing iaw 46 CFR 16.230.
Due 15 April 2002
Resolved 15 April 2002
Operations/Management › Drug and Alcohol Testing
Issued 8 April 2002
Resolved
Provide proof of consurtium MIS submission as per 46 CFR 16.500. LEGACY COMPONENT DESC: MIS Submission
Due 15 April 2002
Resolved 29 May 2002
Resolution: Received copy of MIS.
Construction/Loadline › Hull
Issued 4 April 2002
Resolved
Make proper repair to the hull iwo engine exhaust through hull penetrations. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2002
Electrical › Electrical Distribution System (service)
Issued 4 April 2002
Resolved
Remove all open end wiring through out the entire vessel. LEGACY COMPONENT DESC: Wiring
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Electrical › Electrical Distribution System (service)
Issued 4 April 2002
Resolved
Make all wire connections proper iaw 46 CFR 183.340(g) LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering › Unintentional Flooding
Issued 4 April 2002
Resolved
Re-mount all high bilge alarm on proper brackets and level. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering › Compressed Air System (control)
Issued 4 April 2002
Resolved
Secure air tank for hood closure. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper Installation
Due 8 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 April 2002
Resolved
Mount fixed Co2 bottle off the deck. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering › Gasoline Engine (propulsion)
Issued 4 April 2002
Resolved
Double clamp all flex hoses.
LEGACY COMPONENT DESC: Hose, Cooling System (4 cycle)
Condition: Improper Installation
Due 15 April 2002
Resolved 8 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering › Gasoline Engine (propulsion)
Issued 4 April 2002
Resolved
Replace all non-mettalic flexible hoses in vital system with SAE J-1942. LEGACY COMPONENT DESC: Non-metallic flexible hose
Condition: Unknown
Due 15 April 2002
Resolved 15 April 2002
Resolution: Corrected prior to completion of inspection.
Engineering
Issued 12 October 2001
Resolved
PRIOR TO OPERATING MAKE PERMANENT REPAIRS TO THE ENGINE TO THE SATISFACTIONOF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Fire Fighting
Issued 27 February 2001
Resolved
Provide approval of fixed fire detection system and vapor detection systemsand prove proper operation.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Engineering
Issued 27 February 2001
Resolved
Install a high water temperature alarm.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Fire Fighting
Issued 27 February 2001
Resolved
Post operating instructions for fixed CO2 extinguishing system.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Fire Fighting
Issued 27 February 2001
Resolved
OBTAIN CG APPROVAL FROM THE MARINE SAFETY CENTER FOR INSTALLED CUSTOM CO2 SYSTEM. SECOND PRE-ENGINEERED HALON SYSTEM TO BE RETAINED UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 27 February 2001
Resolved
Permanently marked with a contrasting color the 17" draft mark on the stern
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Documentation
Issued 27 February 2001
Resolved
Provide copy of drug and alcohol program and prove it meets Coast Guard requirements.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 27 February 2001
Resolved
PROVIDE MSO TAMPA A COPY OF OPERATIONS MANUAL FOR VESSEL.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 27 February 2001
Resolved
Provide standard passenger safety orientation cards to assist in safety briefings.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Construction/Loadline
Issued 27 February 2001
Resolved
Either install vent closures to port and starboard vents outboard located aft, or other acceptable arrangements to OCMI.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Fire Fighting
Issued 12 March 1998
Resolved
Provide one B-II portable fire extinguisher.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998
Resolved
Provide a first aid kit.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998
Resolved
Mark adult and child PFD stowage.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998
Resolved
Install 50' line on ring buoy.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998