MAURY USCG vessel records Sign in
← All vessels

WOODEN NICKEL

WOODEN NICKEL is a 1949 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1986, most recently in October 2010, along with 113 deficiencies.

Records from 1986 to 2010. Most recent: inspection, 29 October 2010.

Built
1949
Last inspected
29 October 2010
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9165
Flag
UNITED STATES
366851550, 367307780 (licence lapsed)
Maury page id
psix-42551

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (1986–2010)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.5 ft × 12.4 ft × 4.5 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRONZA N PARKS · WINGATE, MD, UNITED STATES · built 1949
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHESAPEAKE BEACH, MD
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9165MMSI 367307780 · expired · compulsorily equipped · granted 10 August 2007, cancelled 14 October 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDA8183MMSI 366851550 · expired · compulsorily equipped · granted 9 May 2002, cancelled 14 July 2012 · licensed under a name not among this hull’s recorded names (not shown)
WCX3175MMSI not assigned · expired · compulsorily equipped · granted 18 March 1997, cancelled 20 May 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 49

29 October 2010 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3882685
28 October 2008 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3353550
28 February 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3155409
22 September 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2786228
9 March 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602604
23 February 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2296728
22 September 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2199975
6 November 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1942411
14 August 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1661229
22 July 2002 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1650085
1 April 2002 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1599517
19 February 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1486102
6 September 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454993
18 May 2001 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1387100
20 April 2001 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1063008
6 March 2001 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455965
24 February 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 816668
24 February 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1440262
27 January 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 814082
12 August 1999 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1468086
30 November 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 806519
19 December 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448992
19 September 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1112346
29 August 1997 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402513
12 March 1997 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1390480
15 August 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416357
30 November 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1377642
19 September 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1183380
6 September 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412852
9 November 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 61757
1 September 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173210
27 April 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178242
9 September 1993 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 853344
11 August 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 847131
24 July 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1013535
2 April 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1403532
13 August 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1456048
14 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1228622
12 March 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 911472
6 February 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 899694
1 August 1990 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 930063
28 March 1990 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1237750
26 February 1990 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1221160
23 May 1989 Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 895680
2 August 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1346544
19 April 1988 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1040105
6 August 1987 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1020700
24 April 1987 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1027086
9 June 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 993403

Deficiency record · 113

Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 29 October 2010 Resolved
01 Bilge Alarm light inoperable, repair/replace as new
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2010
Resolution: Tested the bilge alarm indicator, indicator light in good order.
Lifesaving › Lifebuoys › Immediately Available
Issued 29 October 2010 Resolved
Ring Lifebuoy wasted, replace as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2010
Resolution: Ring Lifebuoy replaced as new.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 October 2008 Resolved
Provide current copy of COD and COI onboard vessel.
Due 31 January 2009
Resolved 30 January 2009
Resolution: Owner provided originals of documents.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 October 2008 Resolved
Provide current copies of CG Light List and Coast Pilot 3 onboard vessel.
Due 31 January 2009
Resolved 2 February 2009
Resolution: Owner purchased new copies and placed in service.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 October 2008 Resolved
Provide repairs to wiring harness for Fireboy bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Resolution: Tested auto shut-down of Fireboy system, sat.
Documentation › Certificates/Documents › FCC SSL
Issued 28 October 2008 Resolved
Renew FCC SSL.
Due 31 January 2009
Resolved 30 January 2009
Resolution: FCC SSL renewed.
Documentation › Certificates/Documents › FCC SSL
Issued 28 October 2008 Resolved
Renew FCC Safety Certificate.
Due 31 January 2009
Resolved 30 January 2009
Resolution: FCC certificate renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 October 2008 Resolved
Provide repairs to Stern light and show proper operation to attending MI.
Due 31 January 2009
Resolved 30 January 2009
Resolution: Stern light repaired and operating correctly.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2008 Resolved
Replace plank at starboard stern area to the satisfaction of the OCMI.
Due 1 April 2008
Resolved 31 March 2008
Resolution: Replaced plank IAW with Wood NVIC guidance.
Construction/Loadline › Hull › Transverse Frame
Issued 28 February 2008 Resolved
Provide plan proposal for repairs to the rotted area of transverse frame in steering compartment.
Due 1 April 2008
Resolved 31 March 2008
Resolution: Owner provided repairs to the transverse frame in steering compartment IAW Wood NVIC Guidance.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 September 2006 Resolved
Provide operational waterlight for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Resolution: Provided operational waterlight. Verified by marine insepector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 March 2006 Resolved
Wire spiced using wire nuts in bilge space of main cabin. Provide an approved splice.
Due 24 March 2006
Resolved 23 May 2006
Resolution: remved wire nuts for approved means.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 March 2006 Resolved
Provide an operational second emergency portable light.
Due 24 March 2006
Resolved 23 May 2006
Resolution: Provided second flashlight.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 March 2006 Resolved
Replace reflective tape on four type I PFD identified by inspector.
Due 24 March 2006
Resolved 9 March 2006
Resolution: Replace worn reflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 March 2006 Resolved
One type I adult PFD was wasted and not serviceable. Replace the one PFD prior to carriage of 22nd person.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2006
Resolution: Replaaced adual life jacket.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 March 2006 Resolved
Provide proof of hydrostatic testing of portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2006
Resolution: Serviced fire extinguisher.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 March 2006 Resolved
Starboard Bilge Pump visual alarm is extinguished and needs to be replaced.
Due 24 March 2006
Resolved 23 May 2006
Resolution: Replaced light for bilge pump.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 March 2006 Resolved
Provide written proposal for repairs addressing wood root areas on transom outboard frame on port side and aft main deck framing support on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2006
Resolution: Made repairs to vessel. verified and approved by CG Marine Inspector.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 9 March 2006 Resolved
Failed to make vessel available for annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Resolution: Conducted annual examination.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2005 Resolved
Remove the worn rub rail and check the wood underneath.
Due 23 March 2005
Resolved 23 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2005 Resolved
Address soft spots on the surface of marked planks.
Due 23 March 2005
Resolved 23 March 2005
Construction/Loadline › Hull › Keel
Issued 23 February 2005 Resolved
Address joint in skeg that is separating with age.
Due 23 March 2005
Resolved 23 March 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 23 February 2005 Resolved
Remove the old name of vessel and add the new name.
Due 23 March 2005
Resolved 1 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 November 2003 Resolved
Replace reflective tape on 3 lifejackets, vsl not to carry more than 19 adults until complete.
Due 6 December 2003
Resolved 6 November 2003
Construction/Loadline › Penetrations
Issued 6 November 2003 Resolved
Tighten stuffing box on rudder post. LEGACY COMPONENT DESC: Stuffing Box
Due 6 December 2003
Resolved 14 November 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 August 2002 Resolved
Provide proof of current servicing of all fire fighting equipement (fixed and portable).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2002
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 August 2002 Resolved
Label life ring buoy with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2002
Lifesaving › Buoyant Apparatus
Issued 14 August 2002 Resolved
Rerun sea painter for life floats such that payout line won't get tangled. LEGACY COMPONENT DESC: Sea Painter
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 August 2002 Resolved
Replace reflective tape on 2 adult life jackets. Vsl not to carry more than 20 adult passengers until complete.
Due 14 September 2002
Resolved 30 August 2002
Engineering › Fuel Oil Service System
Issued 14 August 2002 Resolved
Provide fuel lines that meet the J1942 standard. LEGACY COMPONENT DESC: Piping
Due 14 September 2002
Resolved 22 November 2002
Communications › Radio Communications
Issued 14 August 2002 Resolved
PROVIDE CURRENT FCC SAFETY CERTIFICATE. LEGACY COMPONENT DESC: FCC SAFETY CERTIFICATE
Due 14 September 2002
Resolved 13 September 2002
Navigation › Piloting/Steering
Issued 14 August 2002 Resolved
Tighten rudder stuffing box. LEGACY COMPONENT DESC: Rudder Stuffing Box
Due 14 September 2002
Resolved 19 November 2002
Communications › Radio Communications › VHF Radiotelephone
Issued 14 August 2002 Resolved
Repair problem with VHF radion prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2002
Construction/Loadline › Structures › Superstructure
Issued 19 February 2002 Resolved
Addres Cabin Overhead frame which is rotted on the end.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 21 February 2002
Construction/Loadline › Structures › Deck Plating
Issued 19 February 2002 Resolved
Repair soft spot on deck, portside and outboard of aft canopy support.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 21 February 2002
Construction/Loadline › Structures › Superstructure
Issued 19 February 2002 Resolved
Address soft wood around portside port light.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 28 February 2002
Construction/Loadline › Structures › Superstructure
Issued 19 February 2002 Resolved
Address areas of rot on port and starboard aft section of canopy.
Condition: Improper/Lack of Maintenance
Due 19 March 2002
Resolved 28 February 2002
Construction/Loadline › Penetrations
Issued 19 February 2002 Resolved
Check & Test chine bolts for wastage and strength. LEGACY COMPONENT DESC: Fasteners
Due 19 March 2002
Resolved 21 February 2002
Lifesaving
Issued 6 September 2001 Resolved
REPLACE REFLECTIVE TAPE ON 10 ADULT AND 3 CHILD LIFE JACKETS.
Condition: Unknown
Due 12 September 2001
Resolved 6 December 2001
Documentation
Issued 6 September 2001 Resolved
PROVIDE PROOF THAT BOTH MASTERS OF VESSEL ARE CURRENTLY ENROLED IN A DRUG PROGRAM.
Condition: Unknown
Due 12 September 2001
Resolved 6 December 2001
Lifesaving
Issued 6 September 2001 Resolved
PROVIDE 3 ORANGE FLARES.
Condition: Unknown
Due 12 September 2001
Resolved 6 December 2001
Accommodation/Occupational Safety
Issued 6 September 2001 Resolved
REPAIR STARBOARD HANDRAIL ON TOP OF CANOPY.
Condition: Unknown
Due 30 November 2001
Resolved 6 December 2001
Construction/Loadline
Issued 6 September 2001 Resolved
ADDRESS AREAS OF SEEPAGE IN BILGES AT NEXT DRY DOCK.
Condition: Unknown
Due 28 February 2002
Resolved 6 September 2001
Lifesaving
Issued 6 September 2001 Resolved
LABLE LOCATIONS OF FLARES AND 1ST AID KIT.
Condition: Unknown
Due 5 October 2001
Resolved 6 December 2001
Lifesaving
Issued 6 September 2001 Resolved
LABLE LIFE FLOAT AND PADDLES W/ VESSEL NAME. LABLE LIFE FLOAT W/ NO. OF PASSENGERS ALLOWED.
Condition: Unknown
Due 5 October 2001
Resolved 6 December 2001
Lifesaving
Issued 6 September 2001 Resolved
PROVIDE TAG FOR WEAK LINK & RECONFIGURE ATTACHMENT OF BUOYANT APPARATUS & LIFE FLOAT TO SEA PAINTER.
Condition: Unknown
Due 5 October 2001
Resolved 6 December 2001
Engineering
Issued 6 September 2001 Resolved
REPACK/TIGHTEN RUDDER STUFFING BOX.
Condition: Unknown
Due 5 October 2001
Resolved 6 December 2001
Lifesaving
Issued 6 September 2001 Resolved
CHANGE NAME ON STERN TO THE NAME OF THE VESSEL ON ITS DOCUMENTATION.
Condition: Unknown
Due 5 October 2001
Resolved 19 February 2002
Documentation
Issued 18 May 2001 Resolved
THE VESSEL IS RESTRICTED FROM CARRYING PASSENERS FOR HIRE UNTIL PROPER AND CURRENT VESSEL DOCUMENTATION IS PROVEN.
Condition: Unknown
Due 18 July 2001
Resolved 22 June 2001
Construction/Loadline
Issued 12 August 1999 Resolved
Provide hand bilge pump.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 12 August 1999 Resolved
Repair leak in bottom planking, port side at the 2nd sister keel outboard from the keelson at the forward end of the engine.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 12 August 1999 Resolved
Adjust rudder post and shaft packing.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Fire Fighting
Issued 12 August 1999 Resolved
Provide replacement bottle for fixed firefighting system.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Lifesaving
Issued 12 August 1999 Resolved
Provide means for seperating child/adult PFDs.
Condition: Unknown
Due 23 August 1999
Resolved 24 August 1999
Lifesaving
Issued 12 August 1999 Resolved
Replace retro-reflective tape on 1 adult and 3 child PFDs. Vessel is limited to 21 total persons and no children until item is completed.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Navigation
Issued 12 August 1999 Resolved
Provide tide table for area of operation.
Condition: Unknown
Due 23 August 1999
Resolved 24 August 1999
Lifesaving
Issued 12 August 1999 Resolved
Trim deteriorated line from both ends of painter for B/A.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 12 August 1999 Resolved
Provide 3-6 line for waterlight attachment to ring buoy.
Condition: Unknown
Due 23 August 1999
Resolved 24 August 1999
Engineering
Issued 19 December 1997 Resolved
REPLACE FLEXIBLE HOSE WITH COPPER PIPING. FLEX HOSE DOES NOT MEET SAE STANDARD.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Electrical
Issued 19 December 1997 Resolved
REMOVE EXCESS WIRING FROM COCKPIT.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
INSTALL HIGH WATER BILGE ALARM.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
PROPERLY WIRE ENGINE ROOM BILGE PUMP.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Construction/Loadline
Issued 19 December 1997 Resolved
REPAIR SHEATHING IN WAY OF THE SHAFT LOG.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 29 August 1997 Resolved
Provide 1 adult lifejacket. Until lifejacket is onboard total persons allowed is 21.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 29 August 1997 Resolved
Provide updated copies of of the following: Rules of the road, Subchapter "T", and charts.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Navigation
Issued 29 August 1997 Resolved
Tighten rudder packing.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Lifesaving
Issued 15 August 1996 Resolved
BA had small cracks that needed to be repaired.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Engineering
Issued 15 August 1996 Resolved
Fuel line missing fuel shutoff valve at engine.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Lifesaving
Issued 15 August 1996 Resolved
5 adult and 1 child PFD's had small cracks that needed to be repaired. Limited the number of passengers until repairs completed.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Navigation
Issued 15 August 1996 Resolved
Vessel had outdated copies of 46 CFR sub-chapter "T" and Rules of the Road.Publications have been ordered from Government printing office.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Electrical
Issued 6 September 1995 Resolved
ELECTRICAL PANEL CONTAINS SEVERAL DEAD END WIRES.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Lifesaving
Issued 6 September 1995 Resolved
LIFE LINE ON BUOYANT APPARATUS TOO TIGHT. CORRECT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 September 1995
Resolved 12 September 1995
Lifesaving
Issued 6 September 1995 Resolved
REFLECTIVE TAPE ON BUOYANT APPARATUS IMPROPERLY AFFIXED. CORRECT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 September 1995
Resolved 12 September 1995
Lifesaving
Issued 6 September 1995 Resolved
LINE ATTACHING WATERLIGHTS TO BUOYANT APPARATUS AND RING BUOY WERE NOT LONGENOUGH. CORRECT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 September 1995
Resolved 12 September 1995
Electrical
Issued 6 September 1995 Resolved
SPLICED AREAS OF WIRES NEED WIRE CONNECTORS.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Electrical
Issued 6 September 1995 Resolved
WING NUTS WERE USED TO ATTACH BATTERY CABLES TO BATTERY.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Engineering
Issued 6 September 1995 Resolved
FUEL RETURN LINE WORN AND IN NEED OF REPLACEMENT.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Engineering
Issued 6 September 1995 Resolved
EXHAUST HOSE WORN AND IN NEED OF REPLACEMENT.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Navigation
Issued 6 September 1995 Resolved
COMPASS LIGHT NOT WORKING.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Fire Fighting
Issued 6 September 1995 Resolved
TWO FIRE EXTINGUISHERS MISSING SEALS ON SAFETY PINS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Electrical
Issued 6 September 1995 Resolved
VESSEL HAD NO WIRE GROUNDING FUEL TANK TO A COMMON GROUND.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Lifesaving
Issued 6 September 1995 Resolved
WEAK LINK ON BUOYANT APPARATUS DESIGNED FOR 11-20 PERSONS, NOT 7 PERSONS ASB/A IS DESIGNED FOR.
Condition: Unknown
Due 6 September 1995
Resolved 12 September 1995
Engineering
Issued 11 August 1993 Resolved
VESSEL MUST HAVE FUEL RETURN HOSE ON MAIN ENGINE REPLACED.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Documentation
Issued 11 August 1993 Resolved
OWNER MUST OBTAIN COPY OFF FCC SAFETY CERTIFICATE AND PLACE ON BOARD VESSEL.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Construction/Loadline
Issued 2 April 1992 Resolved
Replace approx 6 ft. of sister keel inboard on starboard side forward of the engine.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Construction/Loadline
Issued 2 April 1992 Resolved
Replace 07 Planks portside bottom as indicated by inspector.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Engineering
Issued 2 April 1992 Resolved
Renew Cutlass Bearing.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 2 April 1992 Resolved
Replace approx 6 ft. of outboard sister keel on port side aft section.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Construction/Loadline
Issued 2 April 1992 Resolved
Replace 02 planks portside topside aft as indicated by the inspector.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 2 April 1992 Resolved
Replace 01 plank starboard side bottom as indicated by the inspector.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 2 April 1992 Resolved
Replace stern post in kind. This requirement may be satisfied by sending a copy of the yard bill to this office.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 13 August 1991 Resolved
Provide current Light List.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Documentation
Issued 13 August 1991 Resolved
Provide current Documentation sticker.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Lifesaving
Issued 13 August 1991 Resolved
Provide float free link for buoyant apparatus.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Fire Fighting
Issued 13 August 1991 Resolved
Remount and provide proper marine brackets for B-II fire extinguishers
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Construction/Loadline
Issued 13 August 1991 Resolved
Crop and renew approx 3' of sister keel on starboard side in way of batterybox.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Engineering
Issued 13 August 1991 Resolved
Provide double hose clamps for engine exhaust.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Construction/Loadline
Issued 1 August 1990 Resolved
RENEW ROTTED WOOD IN BOW AREA FORWARD OF CABIN TRUNK_x001C_ REQUIREMENTS 1-6 ACTUAL COMPLIANCE DATE: 1SEP90
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Lifesaving
Issued 1 August 1990 Resolved
ENSURE BOUYANT APPARATUS IS ORANGE IN COLOR
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Lifesaving
Issued 1 August 1990 Resolved
PROVIDE 5 ADULT PFD'S. PASSENGERS LIMITED TO 15 UNTIL PFD'S ON BOARD
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Engineering
Issued 1 August 1990 Resolved
INSTALL HEAT DEFLECTOR ON RACOR FUEL FILTERS
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Documentation
Issued 1 August 1990 Resolved
PROVIDE TO MSO BALTO A LTR STATING THAT DRUG TESTING PROGRAM HAS BEEN_x001C_ STARTED PRIOR TO 21DEC90
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Lifesaving
Issued 1 August 1990 Resolved
MARK STOWAGE OF PFD'S
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Fire Fighting
Issued 1 August 1990 Resolved
DEMONSTRATE OPERATION OF HAND BILGE/FIRE PUMP
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Electrical
Issued 2 August 1988 Resolved
PROPERLY FASTEN BATTERY CABLES TO THE TERMINALS.
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Lifesaving
Issued 2 August 1988 Resolved
PROVIDE 10 ADULT PFD'S
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Navigation
Issued 2 August 1988 Resolved
PROVIDE CHARTS (LESS THAN 3 YRS OLD); A COPY OF SUBCHAPTER "T" & COAST PILOT.
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Unknown
Issued 2 August 1988 Resolved
REPAIR LEAK IN WAY OF STERN STBD SIDE.
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Construction/Loadline
Issued 24 April 1987 Resolved
PROPERLY SECURE FOUR DECK HATCHES (INCLUDING ENGINE BOX) WITH SECURING DEVICE AND CAPTIVE CHAIN. HATCHES WHICH ARE PERMANENTLY SECURED DO NOT REQUIRE CHAINS.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Engineering
Issued 24 April 1987 Resolved
RENEW HEATER HOSE TO VENT LINE FOR DIESEL TANK. REPLACED VENT LINE SHALL BE APPROVED FOR FUEL SERVICE.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 24 April 1987 Resolved
MAKE CABIN WATER TIGHT IN WAY OF HEAD ON STARBOARD SIDE.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Electrical
Issued 24 April 1987 Resolved
PROPERLY WIRE LIGHT FIXTURE IN HEAD. USE OF CRIMP CONNECTOR (PRESSURE WIRECONNECTOR) IS ACCEPTABLE.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 24 April 1987 Resolved
PROVIDE MANUFACTURER SPECIFICATION TO PROVE THAT INSULONE HEATER HOSE USED IN TWO BILGE PUMPS IS RESISTENT TO PETROLEUM.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.