Records from 1984 to 1995. Most recent: inspection, 1 August 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 88
1 August 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1183802
15 September 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 868840
15 August 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868479
9 August 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 704006
6 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 533498
20 November 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151630
25 October 1993
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 842045
23 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 684310
23 September 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354871
23 September 1993
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1373922
4 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 50632
16 August 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 843572
10 August 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 212223
4 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 521780
1 May 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357878
15 January 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 491956
15 December 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830294
15 December 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139441
25 November 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11929
10 November 1992
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 963221
20 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243762
8 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253503
24 September 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 938614
3 September 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934470
21 August 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263472
28 July 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 225135
22 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351973
22 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352098
23 June 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 513672
27 May 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 351021
7 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949794
13 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257653
6 April 1992
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258081
22 March 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351052
26 December 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 347872
26 November 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 462937
5 November 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1249644
22 October 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932541
11 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345283
25 April 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 487695
20 April 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229280
16 March 1991
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1228178
16 January 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1237382
8 January 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909346
19 December 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1241702
31 August 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240980
26 August 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1221738
22 August 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 925843
22 August 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1238173
23 July 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211806
17 July 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 527963
16 June 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 918002
8 June 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 904464
7 June 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 515352
7 June 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 903489
13 December 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 334394
13 December 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 457589
6 November 1989
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1323138
4 October 1989
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1341312
25 September 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1307914
22 August 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341792
11 June 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 896514
17 February 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 508740
28 December 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1344086
25 October 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1200398
26 August 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1039572
25 May 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 437493
17 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004099
11 October 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 478693
23 September 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 474756
10 September 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012506
19 May 1987
MARPOL Annex II Examination
Physical examination · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024144
11 May 1987
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1308328
19 March 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 502493
7 October 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1314914
10 September 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 486996
25 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296197
13 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306869
18 July 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307050
13 February 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 529981
24 January 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995662
8 August 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 460644
8 August 1985
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 984608
23 July 1985
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1291165
19 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983801
11 January 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 439861
15 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974734
11 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972692
Fire Fighting
Issued 25 October 1993
Resolved
MAKE PERMANENT REPAIRS TO VENTILATION DOOR IN EMERGENCY GENERATOR ROOM TO MAINTAIN CLASS "A" FIRE BOUNDARY.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Engineering
Issued 25 October 1993
Resolved
RESTENCIL STEAM SMOTHERING SYSTEM AND CUT OFF VALVE.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Deck/Cargo
Issued 25 October 1993
Resolved
MAKE PERMANENT REPAIRS TO HOLE IN AFT PUMPROOM OVERHEAD.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 25 October 1993
Resolved
LOCATION OF INTERNATIONAL SHORE CONNECTION TO BE IDENTIFIED ON FIRE CONTROLPLAN
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Lifesaving
Issued 25 October 1993
Resolved
IMPROPER NUMBER OF LIFEJACKETS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Fire Fighting
Issued 25 October 1993
Resolved
STORE ALL PAINT IN A FIRE PROTECTED SPACE,
Condition: Unknown
Due 25 November 1994
Resolved 22 November 1993
Engineering
Issued 23 September 1993
Resolved
EFFECT REPAIRS TO PORT BOILER SOOT BOX AS NOTED IN PROPOSAL DATED 15 AUGUST1994.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Accommodation/Occupational Safety
Issued 23 September 1993
Resolved
RENEW STORM RAIL ON ALL AFT HOUSE DECKS WHERE RAIL IS MISSING.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Accommodation/Occupational Safety
Issued 23 September 1993
Resolved
RENEW KNIFE EDGE ON STARBOARD SIDE AFT GALLEY DOOR.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
EFFECT REPAIRS TO AFT DECK HOUSE SUPERSTRUCTURE AS NOTED ON REPAIR PROPOSALDATED 15 AUGUST 1994(FIVE DOUBLERS STARBOARD SIDE AND SIX DOUBLERS PORT SIDE).
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
CROP AND RENEW 5'4"X 24' TRIANGULAR SECTION OF DECK PORT SIDE POOP DECK.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Accommodation/Occupational Safety
Issued 23 September 1993
Resolved
REPAIR LADDER AND LANDINGS IN FWD PUMP ROOM.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Engineering
Issued 23 September 1993
Resolved
PATCH HOLES THROUGHOUT INNER STACK.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Deck/Cargo
Issued 23 September 1993
Resolved
REPLACE SMALL STEAM LINE IN WAY OF #3P WING.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Deck/Cargo
Issued 23 September 1993
Resolved
RENEW LOWER MOUNTING BRACKETS TO PORT WINCH IN WAY OF #6C CARGO TANK, AFT WINCH, AND FWD STBD WINCH.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW CATWALK AT CONNECTION WITH THE FWD HOUSE.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW LOWER MOUNT TO CHOCKS (4 EA. 2 PORT, 2 STBD) IN WAY OF #6P CARGO TANK.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Deck/Cargo
Issued 23 September 1993
Resolved
RENEW CARGO TANK STEAM HEAT RETURN LINE FWD END OF AFTER HOUSE WHERE PATCHED.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW DECK AREA BELOW STBD ROLLING CHOCK ON FOCS'L.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Deck/Cargo
Issued 23 September 1993
Resolved
REPAIR HOLE IN CARGO HEADER DRIP PAN CONTANMENT.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
REPAIR HOLE UNDER FWD STBD SIDE WATERTIGHT DOOR AT THE MAIN DECK OF THE FWDHOUSE.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Accommodation/Occupational Safety
Issued 23 September 1993
Resolved
RENEW VENTILATION DUCT TO AFT PUMPROOM STBD SIDE AT 2ND LANDING.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW AS ORIGINAL, PLATING IN WAY OF AFT UPPER DECK PORT & STBD CHOCK & AFTCLOSED CHOCK.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW FWD PUMPROOM ENTANCE AREA BULKHEAD BELOW WATER TIGHT DOOR & AT CONDUIT/STEAM SMOTHERING LINE PENETRATIONS.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Fire Fighting
Issued 23 September 1993
Resolved
RENEW STEAM SMOTHERING LINE TO FWD PUMPROOM AT ENTANCE WHERE HOLED.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW CATWALK AT FOCS'L DECK JUNCTION.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Engineering
Issued 23 September 1993
Resolved
REPAIR HOLE IN INBOARD STBD BOILER CASING.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
REPAIR WASTED STEEL IN WEB FRAMING AND AUX CONDENSER SUPPORT BRACKETS IN WAY OF AUX CONDENSER.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW THEE (3) DOGS TO WATER TIGHT HATCH AT FWD HOLE ON FOCS'L DECK.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Electrical
Issued 23 September 1993
Resolved
RENEW CONDUIT LINE PORTSIDE ALONG CATWALK AS NEEDED.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW CATWALK STANDS & PIPE BRACKETS THROUGHOUT ENTIRE LENGTH OF VESSEL AS NEEDED.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW HINGES TO ALL EXPANSION TRUNK COVERS AS MARKED OR NEEDED.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RE-RING EXPANSION TRUNK TO #6P CARGO TANK, UPPER 4-6 INCHES.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Engineering
Issued 15 December 1992
Resolved
MAKE PERMANENT REPAIRS TO FEED PUMP SUCTION LINE FROM D.C. HEATER (SOFT PATCH) AT FIRST DECK PLATE GRATING BELOW D.C. HEATER, OR IMMEDIATELY IF THEBOILERS ARE SECURED AT ANY TIME DURING THIS EXTENSION PERIOD.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Engineering
Issued 21 August 1992
Resolved
MAKE PERMANENT REPAIRS TO FEED PUMP SUCTION LINE FROM D.C. HEATER (SOFT PATCH) AT FIRST DECK PLATE GRATING BELOW D.C. HEATER. GUAGINGS OF THE D.C. HEATER FEED PUMP SUCTION LINE ARE TO BE TAKEN AND THE REPORT SUBMITTED TO MSO NEW ORLEANS FOR REVIEW.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Deck/Cargo
Issued 21 August 1992
Resolved
REPLACE STEAM PIPING SUPPORTS ALONG CATWALK WHERE NECESSARY.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Lifesaving
Issued 21 August 1992
Resolved
MAKE #1 LIFEBOAT AVAILABLE FOR CG WITNESSED SUPENSION (WEIGHT) TEST.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Construction/Loadline
Issued 21 August 1992
Resolved
REPLACE WASTED PIPE ON STEAM RETURN LINE ON BALLAST PUMP IN PUMPROOM.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Accommodation/Occupational Safety
Issued 21 August 1992
Resolved
RENEW WASTED SEWAGE DRAIN LINE ABOVE MSD UNIT IN ENGINE ROOM.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Fire Fighting
Issued 21 August 1992
Resolved
HYDROSTATICALLY TEST ALL 2 1/2" FIRE HOSES AT A MINIMUM PRESSURE OF 100 PSI
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Engineering
Issued 21 August 1992
Resolved
PROVIDE WATERSIDE AND FIRESIDE INSPECTIONS OF BOTH BOILERS.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Fire Fighting
Issued 21 August 1992
Resolved
RECONNECT OPERATING RODS TO ENGINEROOM SKYLIGHTS.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Engineering
Issued 21 August 1992
Resolved
VEE AND WELD 2' FRACTURE ON AFT OUTBOARD CORNER OF STARBOARD BOILER.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Deck/Cargo
Issued 21 August 1992
Resolved
REPAIR STEAM LEAK ON #3 CARGO PUMP STEAM TURBINE CASING PLUGS AND DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIP ON SAME.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Engineering
Issued 21 August 1992
Resolved
PROVIDE INTERNAL INSPECTION OF THE D.C. HEATER.
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Engineering
Issued 21 August 1992
Resolved
REPAIR SAFETY VALVE ESCAPE PIPING FROM STARBOARD BOILER (HOLED).
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Deck/Cargo
Issued 21 August 1992
Resolved
REPLACE WASTED STEAM PIPING ON MAIN DECK BTWN #8 CENTER AND #9 CENTER CARGOTANK.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Deck/Cargo
Issued 21 August 1992
Resolved
PREPARE THERMAL FLUID HEATERS FOR TESTING OF AUTOMATIC SHUT-DOWNS AND ALARMS.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Lifesaving
Issued 22 October 1991
Resolved
RENEW ALL PFD AND IMMERSION SUITS CHEMICAL LIGHT WITH SOLAS 83 APPROVED LIGHTS.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 22 October 1991
Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL FOUR LIFEBOATS.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Engineering
Issued 8 January 1991
Resolved
WATERWASH FIRESIDES PORT AND STARBOARD BOILERS.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991
Resolved
MAKE AVAILABLE FOR, AND CONDUCT HYDROSTATIC TEST OF MAIN STEAM PIPING.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Unknown
Issued 8 January 1991
Resolved
PRIOR TO CONDUCTING HOT WORK ANYWHERE ON BOARD YOUR VESSEL, YOU MUST FIRST OBTAIN A GAS FREE CERTIFICATE FROM AN NFPA CERTIFIED MARINE CHEMIST AND ENSURE THE CEFRTIFICATE IS MAINTAINED VALID; AND COMPLY WITH ALL PROVISIONS OF THE CERTIFICATE. ISSUED 17 DEC 90.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991
Resolved
REPAIR DAMAGED STEAM PIPING LAGGING IN ENGINEROOM AND INSTALL STEAM BLANKETS AS REQUIRED.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991
Resolved
REPAIR/RENEW REFRACTORY IN WAY OF BURNER CONES, PORT AND STARBOARD BOILERS.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991
Resolved
REPLACE AFTERMOST SUPERHEATER TUBE SUPPORT BRACKET, PORT BOILER
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Unknown
Issued 8 January 1991
Resolved
REPAIR LEAKING GLAND ON INPORT AUXILIARY SANITARY PUMP.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991
Resolved
MAKE AVAILABLE FOR AND CONDUCT INTERNAL EXAM OR HYDROSTATIC TEST OF HP EVAPORATOR._x001C_
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 22 August 1990
Resolved
MAIN CONDENSER OVERBOARD DISCHARGE SPOOL PIECEWRAPPED WITH NONMETALLIC MATERIAL PREVENTING EXAMINATION OF SPOOL PIECE. REMOVE NON METALLIC WRAP AND MAKE SPOOL PIECE AVAILABLE FOR EXAMINATION.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
LAGGING MISSING FROM NUMEROUS STEAM & HIGH TEMPERATURE OIL LINES IN FIRE ROOM. SUITABLY INSULATE ALL PIPING, INCLUDING VALVES, PIPE FIT-TINGS AND FLANGES CONVEYING VAPORS, GASES OR LIQUIDS WHOSE TEMPERATURE EXCEEDS 150 F AS REQUIRED BY 46CFR 56.50-1(K)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
AUTOMATIC CO2 VENT SHUT DOWN FAILED TO OPERATE. PROVE PROPER OPERATION OF CO2 AUTOMATIC VENT SHUTDOWN.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Deck/Cargo
Issued 22 August 1990
Resolved
CONDUCT OPERATING TEST OF FIRED THERMAL FLUID HEATERS IN ACCORDANCE WITH 46CFR 61.30-20.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990
Resolved
FUSES IN ELECTRICAL PANEL BOXES OVERSIZED. PROPERLY SIZE FUSES IN ALL ELECTRICAL PANEL BOXES IN ACCORDANCE WITH PANEL DIRECTORIES.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990
Resolved
STEAM HEATING LINES PENETRATING FORWARD PUMP ROOM FORWARD BULKHEAD HAVE TEMPORARY REPAIR. MAKE PERMANANT PEPAIR TO BULKHEAD IN LIEU OF TEMPORARY REPAIR INWAY OF STEAM LINE PENETRATIONS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
BOLT HEADS SECURING BONNET TO AUXILIARY CONDENSER CROSS OVER VALVE WASTED. RENEW BONNET BOLTS AND NUTS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
MAKE TAILSHAFT AVAILABLE FOR DRAWN CREDIT EXAM.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
MAIN CONDENSER OVERBOARD SPOOL PIECE FLANGE NUTS AND STUDS WASTED. RENEW WASTED STUDS AND NUTS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
MAIN PROPULSION BOILERS MISSING NAME PLATES. PROVIDE METAL NAME PLATES FOR PORT AND STBD MAIN BOILERS AS REQUIRED BY 46CFR 52.01-140(5)(C).
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
STBD BOILER MAIN PROPULSION THROTTLE VALVE MISSING OPEN/SHUT INDICATOR. PROVIDE OPEN SHUT INDICATOR FOR THROTTLE VALVE.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990
Resolved
EFFECT TEMPORARY REPAIR TO AND PROVE WATER TIGHTNESS OF FORWARD PUMP ROOM FORWARD BULKHEAD.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
MAKE PORT AND STBD MAIN BOILERS AVAILABLE FOR FIRE AND WATER SIDE EXAM.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
CONDUCT HYDROSTATIC TEST OF MAIN STEAM PIPING AND PORT AND STBD MAIN BOILERS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
MAKE DC HEATER AND HP EVAPORATOR AVAILABLE FOR HYDROSTATIC TEST OR INTERNALEXAMINATION AS REQUIRED.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Deck/Cargo
Issued 7 June 1990
Resolved
RENEW ALL CARGO TANK FLAME SCREENS AND REPLACE MISSING BOLTS. TO BE COMPLETED PRIOR TO VESSEL'S DEPARTURE FROM PORT OF CORPUS CHRISTI.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Deck/Cargo
Issued 7 June 1990
Resolved
RENEW OR CLEAN AS NEEDED ALL ULLAGE FLAME SCREENS. TO BE COMPLETED PRIOR TO VESSEL'S DEPARTURE FROM PORT OF CORPUS CHRISTI.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Deck/Cargo
Issued 7 June 1990
Resolved
RENEW AS NEEDED ALL GOOSENECK FLAME SCREENS. TO BE COMPLETED PRIOR TO VESSEL'S DEPARTURE FROM PORT OF CORPUS CHRISTI.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Accommodation/Occupational Safety
Issued 7 June 1990
Resolved
MAKE REPAIRS TO THE MSD SYSTEM & PROOF TEST OPERATION IN THE PRESENCE OF A USCG MARINE INSP. IF THE MSD IS NOT FIXED WITHIN 12 HOURS, PORTABLE TOILETSWILL HAVE TO BE ON BOARD THE VESSEL.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Construction/Loadline
Issued 7 June 1990
Resolved
MAKE REPAIRS TO LTHE OILY WATER SEPERATOR. OILY WATER MUST BE PUMPED INTO A DIRTY BALLAST TANK AND THEN PUMPED ASHORE TO AN APPROVED FACILITY.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Engineering
Issued 4 October 1989
Resolved
PROVE PROPER OPERATION OF D.C. HEATER RELIEF VALVE AT NEXT SCHEDULED DRY- DOCK OR NLT 28FEB91.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Fire Fighting
Issued 10 September 1987
Resolved
PROVIDE A COPY OF THE FIXED FOAM SYSTEM FAOM ANALYSIS.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Lifesaving
Issued 23 July 1985
Resolved
HAVE #3 LIFE BOAT WEIGHT TESTED AND RE-ISSUE CORRECTED EQUIPMENT CERT. (SOLAS) TO INDICATE 2ND MOTOR LIFE BOAT.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Unknown
Issued 11 June 1984
Resolved
COMPLETE THE DRYDOCK EXAMINATION PRIOR TO ANY CONTRACT OR CARGO TYPE OPERATION.
Condition: Unknown
Due 11 June 1984
Resolved 11 June 1984
Unknown
Issued 11 June 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE PECOS, DN259357.
Condition: Unknown
Due 11 June 1984
Resolved 11 June 1984