Records from 1984 to 2012. Most recent: inspection, 10 June 2012.
Inspection history · 149
10 June 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4339202
26 July 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3279693
23 July 2008
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3277149
13 September 2007
Administrative Inspection
Administrative · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3056905
10 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3054341
9 May 2007
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2925751
7 February 2007
Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2868657
12 September 2006
MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2777099
12 September 2006
MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2784649
7 August 2006
Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2701681
28 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2668470
28 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2668496
28 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2668515
28 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2668619
9 May 2006
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2612149
13 March 2006
Periodic Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2601278
23 September 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2499638
23 September 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2499643
16 September 2005
Periodic Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2493851
5 August 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452733
5 August 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452736
5 August 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452742
5 August 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452749
22 July 2005
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2436046
22 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2450376
22 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2450380
17 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2433097
17 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2433102
14 July 2005
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2426835
12 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2424150
12 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2424162
8 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2424128
8 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2424143
16 June 2005
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2426868
12 May 2005
COI Inspection
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2363267
22 March 2005
Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2316632
1 February 2005
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2287832
28 January 2005
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2289217
21 December 2004
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2262631
11 November 2004
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2239806
9 November 2004
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2239695
16 September 2004
Annual Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2196815
21 June 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2105629
11 June 2004
Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2095503
3 June 2004
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2086641
13 May 2004
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2065424
12 February 2004
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2005656
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977598
7 November 2003
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1943585
4 August 2003
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1863917
4 August 2003
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1874125
27 May 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1802977
5 May 2003
COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1787204
19 March 2003
Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1759528
14 March 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1757424
6 February 2003
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1740670
14 November 2002
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1763183
7 October 2002
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1686634
9 May 2002
COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1614658
13 November 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420617
4 October 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1074724
10 August 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1449497
10 May 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1060446
10 May 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1426569
2 August 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 821697
13 July 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 820301
12 July 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1051797
29 March 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 816777
10 March 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1462060
29 October 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1130034
8 October 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1438913
6 October 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 114986
1 August 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 125604
7 April 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415268
3 March 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 793676
3 March 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1381502
18 September 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799684
19 August 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799376
7 April 1998
Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 774370
20 March 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 659509
19 March 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 170160
3 March 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1108554
14 January 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 778084
15 September 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 777140
10 March 1997
Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1102065
1 October 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 833820
20 June 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088325
1 April 1996
Deficiency Check · COI Inspection · Plan Review "T" Boat
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1080968
29 February 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1435730
15 March 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 868534
15 December 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 853330
14 October 1994
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1177137
8 July 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 187647
27 April 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 858372
18 March 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 855996
14 March 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403747
7 October 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1419166
22 June 1993
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 845296
24 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1362774
18 May 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1167651
7 April 1993
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1149689
23 November 1992
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1136942
2 November 1992
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 935461
15 July 1992
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1248409
20 May 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950621
1 April 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 37984
24 July 1991
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1244949
21 March 1991
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 928695
14 March 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 910002
14 March 1991
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 912492
1 May 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227139
5 April 1990
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1217941
13 March 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 913864
24 August 1989
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1338137
12 May 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1207868
10 May 1989
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1340160
19 April 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1194087
19 April 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1350303
13 April 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1039790
6 January 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 888617
12 October 1988
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1197061
13 August 1988
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1035849
30 July 1988
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1038017
13 June 1988
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1207157
29 March 1988
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990294
29 January 1988
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1323977
5 November 1987
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1020605
29 October 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1016013
29 October 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1016015
29 October 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1018843
14 July 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1019480
24 June 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1315743
15 April 1987
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1003575
2 February 1987
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317241
14 January 1987
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1314584
7 January 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1006295
6 January 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1313585
25 September 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311933
6 August 1986
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1018052
26 February 1986
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1297636
4 February 1986
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1292632
9 August 1985
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1298824
11 June 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 982488
18 April 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1289447
29 March 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1287881
1 March 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 977905
29 January 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1285128
8 November 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1286863
15 October 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 974511
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 12 July 2007
Resolved
Prove proper operation of reverse power relays for SSDGs
Due 31 July 2007
Resolved 19 July 2007
Resolution: Reverse power relays operational.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Replace extinguished emergency and deck lighting throughout vessel.
Due 31 July 2007
Resolved 19 July 2007
Resolution: Lighting replaced.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 July 2007
Resolved
Replace or remove PVC piping that penetrates CO2 room bulkhead w/ metallic piping and flange.
Due 31 July 2007
Resolved 19 July 2007
Resolution: PVC pipe replace w/ metallic pipe.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 July 2007
Resolved
Remove or replace PVC piping penetrating E/R bulkheads.
Due 31 July 2007
Resolved 19 July 2007
Resolution: PVC pipe replaced w/ metallic piping.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 12 July 2007
Resolved
Prove proper operation of the EOT from both pilot houses.
Due 31 July 2007
Resolved 19 July 2007
Resolution: EOT repaired
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 12 July 2007
Resolved
Provide four portable fire extinguishers.
Due 31 July 2007
Resolved 19 July 2007
Resolution: Four portables placed onboard.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 July 2007
Resolved
Repair seal to fire pump.
Due 31 July 2007
Resolved 19 July 2007
Resolution: Fire pump repaired and tested.
Construction/Loadline › Structures › Manhole
Issued 12 July 2007
Resolved
Install hatch keepers to manholes on freight deck.
Due 31 July 2007
Resolved 19 July 2007
Resolution: Keeper chains installed.
Construction/Loadline › Structures › Manhole
Issued 12 July 2007
Resolved
Replace gaskets to marked man holes.
Due 31 July 2007
Resolved 19 July 2007
Resolution: Gaskets replaced.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 July 2007
Resolved
Repair or remove cracked pipe at bottom of ladder to CO2 room.
Due 31 July 2007
Resolved 19 July 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 July 2007
Resolved
Make permanent repairs to fire screen doors 4 and 7 and on the 03 deck.
Due 31 July 2007
Resolved 12 July 2007
Resolution: Fire screen doors repaired.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 July 2007
Resolved
Replace flame screens to fuel tank vent pipes.
Due 31 July 2007
Resolved 19 July 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 July 2007
Resolved
Provide servicing certificate for inflatable liferafts prior to carrying of passengers.
Due 31 December 2007
Resolved 15 November 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 July 2007
Resolved
Conduct drills (security, fire, man overboard recovery) prior to carrying passengers.
Due 31 December 2007
Resolved 13 September 2007
Engineering › Steering Gear System › Linkage
Issued 9 May 2006
Resolved
Prior to commercial operations, install safety lock wires or other suitable mechanical arrangements to prevent steering ram anchor pinlock bolts from backing out.
Due 9 June 2006
Resolved 24 May 2006
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 9 May 2006
Resolved
Provide servicing certificates for all IBAs, prior to carriage of passengers.
Due 9 May 2006
Resolved 9 May 2006
Construction/Loadline › Structures › Door
Issued 9 May 2006
Resolved
Renew missing wx tight gasket on bow and stern loading doors prior to carriage of passengers.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 9 May 2006
Resolved
Adjust sprinkler head at starboard stern (zone 3) to point in downward direction.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Fire Main › Condition
Issued 9 May 2006
Resolved
Provide repair proposal of ruptured fire main, and repair to satisfaction of OCMI prior to carriage of passengers.
Due 9 June 2006
Resolved 24 May 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 May 2006
Resolved
Replace missing placard on PFD stowage box midship forward boat deck.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 May 2006
Resolved
Fill bolt-hole penetrations on inboard mezzanine decks.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 May 2006
Resolved
Fill electrical wire run in deck of snack bar pantry with fire stop.
Due 9 June 2006
Resolved 24 May 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 May 2006
Resolved
Renew or repair all junction box & circuit breakers doors on mezzanine decks.
Due 9 June 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 May 2006
Resolved
Remove extension cords, work lights, and temp services from bilges of both steering gear compartments prior to conclusion of overhaul period.
Due 9 June 2006
Resolved 24 May 2006
Engineering › Steering Gear System › Ram Seal
Issued 9 May 2006
Resolved
Prior to commercial operations, permanently repair leaking steering ram of aft ram bow steering gear unit.
Due 9 June 2006
Resolved 24 May 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 9 May 2006
Resolved
Permanently repair or replace the #2 generator voltmeter.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Means of Escape › Doorways
Issued 9 May 2006
Resolved
Repair or renew escape hatch from aux. machinery space prior to commercial operations.
Due 9 June 2006
Resolved 24 May 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 9 May 2006
Resolved
Prior to conclusion of yard period, install a mechanical locking arrangement on MSD RAW sewage overboard valve to prevent inadvertent operation of valve while within 3 NM of nearest shoreline.
Due 9 June 2006
Resolved 24 May 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 May 2006
Resolved
Demonstrate satisfactory performance of emergency fire and MOB drills to USCG.
Due 19 May 2006
Resolved 31 May 2006
Resolution: Satisfactorily completed this date
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 29 March 2006
Resolved
Ships Service main breakers mis-labeled for 800 amp service rather than actual 600 amp service. Re-lable same for proper rating.
Due 9 June 2006
Resolved 24 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 March 2006
Resolved
Servicing certificate missing for all fire fighting equipment aboard.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 March 2006
Resolved
Chief Engineer was unable to demonstrate satisfactory manual testing of the emergency generator due to apparent unfamiliarity of the system. Required a written set of operating instructions to be posted at the operating station for the emergency generator engine controls and emergency switchboard.
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 22 March 2006
Resolution: Noted as corrected this date.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 May 2005
Resolved
Conduct u/w fire and man ovbd drills.
Due 12 June 2005
Resolved 16 June 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 May 2005
Resolved
100 person IBA was still at servicing facility and not on board. Vessel total person count limited to no greater than 710.
Due 12 June 2005
Resolved 16 June 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 May 2005
Resolved
Install red "E" on all lunch counter lights. (12 total). Lights are apart of emergency lighting and not labeled.
Due 12 June 2005
Resolved 16 June 2005
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 12 May 2005
Resolved
Replace paddle in rescue boat.
Due 12 June 2005
Resolved 16 June 2005
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 12 May 2005
Resolved
Post life jacket donning placards on forward and aft bulkheads on top deck.
Due 12 June 2005
Resolved 16 June 2005
Lifesaving › Launching Appliances › Winch
Issued 21 December 2004
Resolved
Make permanent repairs to inoperative electric winch motor.
Condition: Unknown
Due 23 December 2004
Resolved 21 December 2004
Resolution: Blown fuse found in winch controll box and replaced. Winch operationally tested sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 16 September 2004
Resolved
Noted broken door to electrical distibution pannel on starboard side mezzanine deck.
Condition: Improper/Lack of Maintenance
Due 16 September 2004
Resolved 16 September 2004
Documentation › Markings/Placards › Warning Signs
Issued 16 September 2004
Resolved
Noted several general alarm bells missing identification labels (IVO captain state room and crew lounge).
Due 16 September 2004
Resolved 16 September 2004
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 11 June 2004
Resolved
1. Provide training manual in accordance with 46 CFR 199.180, with emphasis on procedures for launching and recovering rescue boats.
Due 31 January 2005
Resolved 16 June 2005
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 11 June 2004
Resolved
2. Submit muster list format for OCMI approval in accordance with 46 CFR 199.217
Due 31 January 2005
Resolved 16 June 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 May 2004
Resolved
Conduct all underway drills prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2004
Resolved 19 May 2004
Resolution: Drills completed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 May 2004
Resolved
"E" light iwo of FSD #7 inop.
Due 17 June 2004
Resolved 19 May 2004
Resolution: Replaced light.
Construction/Loadline › Hull › Hull Plating
Issued 13 May 2004
Resolved
Make permanent repairs to holes in escape trunks on the uppermost deck.
Due 17 June 2004
Resolved 19 May 2004
Resolution: Repairs complete.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 12 February 2004
Resolved
REPLACE ALL CREW LIFE JACKETS AS NECESSARY DUE TO TEARS.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 3 June 2004
Resolution: CREW JACKETS REPLACED.
Fire Fighting › Fire Pumps › Pressure
Issued 4 August 2003
Resolved
MAKE #2 FIRE PUMP OPERATIONAL.
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 4 August 2003
Resolution: FIRE PUMP REPAIRED AND TESTED SAT.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 4 August 2003
Resolved
REPLACE OUTBOARD ENGINE DUE TO CAPSIZING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2003
Resolved 4 August 2003
Resolution: OUTBOARD REPLACED AND TESTED SAT.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 August 2003
Resolved
CONDUCT MAN OVERBOARD DRILL TO TEST EQUIPMENT FOLLOWING CAPSIZING OF RESCUE BOAT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2003
Resolved 4 August 2003
Resolution: EQUIPMENT TESTED SAT.
Operations/Management › Drills/Instruction
Issued 5 May 2003
Resolved
CONDUCT UNDERWAY MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 6 June 2003
Resolved 27 May 2003
Resolution: DRILLS COMPLETED SAT.
Personnel › Manning/Qualifications
Issued 5 May 2003
Resolved
PROVIDE COPIES OF THE SHIPS LOGS, COMPLETE PAY RECORDS AND REQUESTS TO EXCHANGE TRIP/WATCHES, FOR ALL PERSONNEL ASSIGNED TO THE VESSEL FOR THE WEEK OF 05-11 APRIL 03. RECORDS TO BE DELIVERED TO THE SIO, MSO PROVIDENCE, R.I. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 27 May 2003
Resolution: RECORDS PROVIDED.
Stability › Watertight Integrity
Issued 19 March 2003
Resolved
Renew/repair Scuttle on Car deck. Non-anchor end. LEGACY COMPONENT DESC: Scuttle
Due 12 May 2003
Resolved 6 May 2003
Resolution: SCUTTLE REPAIRED.
Fire Fighting › Combustible Materials
Issued 19 March 2003
Resolved
Remove excess flamable stores from Steering room and properly store remainder.
Condition: Improper/Lack of Maintenance
Due 12 May 2003
Resolved 6 May 2003
Resolution: STORES REMOVED AND STOWED PROPERLY.
Accommodation/Occupational Safety › Occupational Safety
Issued 19 March 2003
Resolved
Repair Ladder Bracket in in Steering Room. LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 12 May 2003
Resolved 6 May 2003
Resolution: LADDER BRACKET REPAIRED.
Fire Fighting › Ventilation Systems
Issued 19 March 2003
Resolved
Prove proper operation of all Mushroom Vents on overhead of Upper Crews Qtrs and Snack Bar and properly label. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Due 12 May 2003
Resolved 6 May 2003
Resolution: VENTS REPAIRED AND MARKED.
Fire Fighting › Ventilation Systems
Issued 19 March 2003
Resolved
Prove proper operation and chalk test E/R Skylight. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Due 12 May 2003
Resolved 6 May 2003
Resolution: E/R SKYLIGHT REPAIRED AND TESTED SAT.
Fire Fighting › Structural Fire Protection - General
Issued 19 March 2003
Resolved
Seal all Penetrations that lead directly to the car deck under both pilot houses. LEGACY COMPONENT DESC: Superstructure Construction
Condition: Placed in Improper Service
Due 12 May 2003
Resolved 6 May 2003
Resolution: PENETRATIONS WELDED SHUT.
Communications › Internal Communications System
Issued 19 March 2003
Resolved
Repair PA Spkr in Bow.
Condition: Unknown
Due 12 May 2003
Resolved 6 May 2003
Resolution: SPEAKER REPAIRED.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 19 March 2003
Resolved
Repair window in [name withheld].
Condition: Placed in Improper Service
Due 12 May 2003
Resolved 6 May 2003
Resolution: WINDOW REPLACED.
Personnel › Manning/Qualifications
Issued 6 February 2003
Resolved
PROVIDE A COPY OF THE SHIP'S LOGS AND COMPLETE PAY RECORDS FOR ALL REQUIRED PERSONNEL ASSIGNED TO THE VESSEL FOR THE WEEK OF 13-20 JAN 03. RECORDS TO BE DELIVERED TO THE SENIOR INVESTIGATING OFFICE, MSO PROVIDENCE. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 21 February 2003
Resolved 14 March 2003
Resolution: LOGS AND RECORDS DELIVERED TO MSO PROVIDENCE.
Construction/Loadline
Issued 10 May 2001
Resolved
REBUILD MAIN BILGE PUMP/MOVER AND TEST TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Navigation
Issued 10 May 2001
Resolved
Comms for emergency steering station inadequate, comms not readily available for the steering station in the engine room.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Deck/Cargo
Issued 10 May 2001
Resolved
Provide Inclinometer for #1 end pilot house.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Engineering
Issued 10 May 2001
Resolved
RENEW BOILER PLATE TO REFLECT NEW MAX PRESSURE REQUIREMENTS FOR HYDROTESTING. BOILER CAN BE OPERATED DURING INTERIM PERIOD.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 10 May 2001
Resolved
Fire Screen Doors (7 & 8) remove manual hold backs. Doors (1,4,5,6) did not properly close when activated.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Lifesaving
Issued 29 March 2000
Resolved
Inflatable Bouyant App. #2 is removed for temp use on another vessel. Total persons allowed to be carried is limited to 696 until replacement is installed.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 10 March 2000
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, CONDUCT A WEIGHT AND OPERATIONAL TEST OF THE RESCUE BOAT DAVIT WINCH ASSEMBLY IAW 46CFR199.153.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000
Resolved
SUBMIT ELECTRICAL DRAWINGS FOR THE INSTALLATION OF THE NEW AC WINCH IAW 46 CFR 199.153(K). INSTALLATION AND WIRING WERE DONE AT RISK.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000
Resolved
SUBMIT ELECTRICAL PLANS FOR THE DC TO AC ELECTRICAL MODIFICATIONS. ALL EXISTING WORK AND ELECTRICAL MODIFICATION WERE DONE AT RISK.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Construction/Loadline
Issued 7 April 1999
Resolved
Druning the hull out in Febuary 2000 have all thin plate in the hull and side shell replaced as per your survey done and letter from May 13, 1999.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Lifesaving
Issued 7 April 1998
Resolved
CONDUCT FIRE AND BOAT DRILS IN THE PRESENCE OF AN COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 May 1998
Resolved 29 May 1998
Construction/Loadline
Issued 3 March 1998
Resolved
MAKE REMOTE BILGE SUCTION REACH ROD OPERABLE TO FORWARD RUDDER COMPT.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
REWELD ALONG FORWARDMOST FRAME OF FORE/AFT PEAK VOIDS.
Condition: Unknown
Due 1 April 1998
Resolved 27 May 1998
Construction/Loadline
Issued 3 March 1998
Resolved
REMOVE ANGLE IRON CAP PREVIOUSLY USED FOR OLD CABLE STEERING SYSTEM FROM FORWARD PEAK VOID ATHWARTSHIP FRAME TO FACILITATE FUTURE INSPECTIONS OF THEGENERAL AREA.
Condition: Unknown
Due 1 April 1998
Resolved 27 May 1998
Construction/Loadline
Issued 3 March 1998
Resolved
CROP/RENEW WEB FRAME IN AFT PEAK VOID.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
DURING NEXT SCHEDULED CREDIT DRYDOCK, REMOVE ALL SOLID LEAD BALLAST FROM BILGE AREAS THROUGHOUT VESSEL TO ALLOW COMPREHENSIVE EXAM OF AREAS AFFECTED.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Engineering
Issued 10 March 1997
Resolved
PROVIDE INSULATION FOR AUX STEAM LINE IN CO2 STORAGE SPACE STBD SIDE.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 10 March 1997
Resolved
PROVIDE 18 CHILD AND 50 ADULT PFD AS REQUIRED BY COI.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Fire Fighting
Issued 10 March 1997
Resolved
PROVIDE EXPLOSION PROOF FLASHLIGHTS FOR FIREMANS OUTFITS.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Engineering
Issued 10 March 1997
Resolved
PROVIDE INSULATION FOR STEAM LINES IN AUX ENG SPACE FWD BULKHEAD.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Electrical
Issued 10 March 1997
Resolved
SECURE ELECTRICAL WIRES IN FWD STEERING SPACE.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 10 March 1997
Resolved
PROVIDE REQUIRED DISTRESS FLARES.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Fire Fighting
Issued 10 March 1997
Resolved
REPLACE HOSE ON HOSE REEL ON SEMI-PORTABLE FF SYSTEM IN E/R.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Engineering
Issued 10 March 1997
Resolved
PROVIDE INSULATION FOR HEATING STEAM LINE ON FREIGHT DECK AMIDSHIPS STBD SIDE.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Fire Fighting
Issued 10 March 1997
Resolved
CLEAN STBD QTR AFT SPRINKLER NOZZLES.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Fire Fighting
Issued 10 March 1997
Resolved
REPLACE TWO 100LB EMPTY CO2 CYLINDERS FOR FF SYSTEM.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Deck/Cargo
Issued 1 October 1996
Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 1 October 1996
Resolved 1 October 1996
Engineering
Issued 1 October 1996
Resolved
FREE UP EMERGENCY BOILER FUEL AND MAIN ENGINE FUEL VALVES.
Condition: Unknown
Due 1 October 1996
Resolved 1 October 1996
Navigation
Issued 1 October 1996
Resolved
RUDDER PACKING AT WOODS HOLE END LEAKS EXCESSIVELY.
Condition: Unknown
Due 1 October 1996
Resolved 1 October 1996
Accommodation/Occupational Safety
Issued 20 June 1996
Resolved
FREEUP VENT DAMPERS, PORT AND STARBOARD MUSHROOM VENTS-WEATHER DECK.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Navigation
Issued 20 June 1996
Resolved
REPLACE SELECTOR KNOB-CREW QUARTERS SOUND POWERED PHONE.
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Fire Fighting
Issued 1 April 1996
Resolved
INSTALL RELIEF VALVES AND VENT VALVES IN DISTRIBUTION MANIFOLD FOR NEW FIXED CO2 SYSTEM.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 1 April 1996
Resolved
REPAIR DOOR LATCH HARDWARE FOR FIRE SCREEN DOORS AND ADJUST CLOSING MECHANISM.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 1 April 1996
Resolved
CLEAN-OUT PLUGGED SPRINKLER HEADS FOR CAR DECK SPRIKLER SYSTEM.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Navigation
Issued 1 April 1996
Resolved
REPAIR/REPLACE LEAKING STEERING GEAR RAM, AFT END.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 1 April 1996
Resolved
PROVIDE SEA PAINTER CLEATS AT LIFERAFT CRADLES.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 1 April 1996
Resolved
REPAIR 2 NON-OPERATIONAL GENERAL ALARMS, BY PURSURS STATE ROOM AND IN GALLEY AND REPLACE MISSING PLACARDS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Navigation
Issued 1 April 1996
Resolved
FWD LOUDSPEAKER PARTIALLY BLOCKS FWD RANGE LIGHT, REMOVE/RELOCATE SPEAKER.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 1 April 1996
Resolved
SERVICE HYDRO RELEASES AS INDICATED BY INSPECTOR_x001C_
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 1 April 1996
Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Electrical
Issued 1 April 1996
Resolved
REPLACE MISSING "E" LABELS FOR EMERGENCY LIGHTS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 29 February 1996
Resolved
CROP/RENEW AS ORIGINAL HULL PLATING LOCATED IN THE "C" STRAKE ON THE STBD SIDE DIRECTLY BELOW THE BOILER.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Construction/Loadline
Issued 15 March 1995
Resolved
RENEW/REPAIR PORT AND STARBOARD CAR DECK SIDE PORT DOORS AND PORT LINE HANDLING DOORS.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Construction/Loadline
Issued 15 March 1995
Resolved
RECONDITION FORE AND AFT LOADING DOORS.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Accommodation/Occupational Safety
Issued 15 March 1995
Resolved
FREE UP VENT CLOSURES IN WEATHER DECK MUSHROOM VENTS.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Navigation
Issued 15 March 1995
Resolved
REPLACE RANGE LIGHT LENSES.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Fire Fighting
Issued 15 March 1995
Resolved
FREE-UP VALVE AT FIRE STATION NO. 9.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Navigation
Issued 15 March 1995
Resolved
REPAIR INDICATOR LIGHTS ON PILOT HOUSE(BOTH ENDS) PROPULSION THROTTLE PANELS TO SHOW PROPER INDICATION.
Condition: Unknown
Due 15 March 1995
Resolved 21 March 1995
Lifesaving
Issued 15 March 1995
Resolved
REPLACE 18 ADULT AND 5 CHILD PFD'S.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 15 March 1995
Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 25 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 15 March 1995
Resolved
CONDUCT TEST OF CAR DEC SPRINKLER SYSTEM.
Condition: Unknown
Due 25 March 1995
Resolved 28 March 1995
Lifesaving
Issued 14 March 1994
Resolved
MAKE EMBARKATION LADDER OF PORT SIDE W/H END FIT PROPERLY TO HANDRAILS.
Condition: Unknown
Due 31 March 1994
Resolved 27 April 1994
Electrical
Issued 14 March 1994
Resolved
PROVIDE APPROVED PLANS FOR GRAY WATER PUMP RETROFIT FROM DC TO AC SYSTEM.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Lifesaving
Issued 14 March 1994
Resolved
CONDUCT FIRE AND BOAT DRILLS IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1994
Resolved 23 March 1994
Electrical
Issued 14 March 1994
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM FAN REMOTE STOP.
Condition: Unknown
Due 31 March 1994
Resolved 23 March 1994
Documentation
Issued 14 March 1994
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 31 March 1994
Resolved 27 April 1994
Electrical
Issued 14 March 1994
Resolved
PROPERLY LABEL CIRCUIT BREAKERS FOR PANELS IN AUX. MACHINERY SPACE, W/H END.
Condition: Unknown
Due 31 March 1994
Resolved 23 March 1994
Navigation
Issued 14 March 1994
Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 31 March 1994
Resolved 27 April 1994
Electrical
Issued 14 March 1994
Resolved
INSTALL GLOBES FOR LIGHTS IN CONCESSION STAND STOREROOM AND CREW QTRS.
Condition: Unknown
Due 31 March 1994
Resolved 27 April 1994
Lifesaving
Issued 24 May 1993
Resolved
CONDUCT UNDERWAY DRILLS IN PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 24 May 1993
Resolved
COVER TWO OPEN JUNCTION BOXES ABOVE THE MAIN SWITCHBOARD.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 20 May 1992
Resolved
PROVE PROPER OPERATION OF AUDIBLE AND VISUAL ALARM FOR VINEYARD HAVEN END MAIN DIESEL ENGINE.
Condition: Unknown
Due 20 July 1992
Resolved 23 September 1992
Electrical
Issued 20 May 1992
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR AUDIBLE ALARMS AND OVER SPEEDSHUTDOWN.
Condition: Unknown
Due 20 July 1992
Resolved 23 September 1992
Lifesaving
Issued 20 May 1992
Resolved
CONDUCT FIRE AND BOAT DRILLS IN PRESENCE OF A C.G.INSPECTOR.
Condition: Unknown
Due 20 July 1992
Resolved 23 September 1992
Documentation
Issued 20 May 1992
Resolved
PROVIDE APPROVED STABILITY DATA FOR MODIFICATIONS TO PROPULSION.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 14 March 1991
Resolved
CONDUCT SATISFACTORY FIRE AND BOAT DRILL._x001C_
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Engineering
Issued 14 March 1991
Resolved
PROVE PROPER OPERATION OF REMOTE STOP FOR LUBE OIL CENTRIFUGE.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Navigation
Issued 14 March 1991
Resolved
MAKE PERMANENT REPAIRS TO RUDDER ANGLE INDICATOR REPEATER ROD AT VINEYARD_x001C_ HAVEN END.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 19 April 1989
Resolved
PROVIDE DC AMMETER, DC VOLT METER, AND GROUND DETECTION LIGHT FOR DC SWITCHBOARD AND INSTALL
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Accommodation/Occupational Safety
Issued 19 April 1989
Resolved
REPAIR OR REPLACE #1 SANITARY PUMP
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 19 April 1989
Resolved
PROVIDE AND INSTALL FLASHING REDLIGHT FOR GENERAL ALARM IN ENGINEROOM
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Construction/Loadline
Issued 19 April 1989
Resolved
INSTALL APPROVED A-60 STRUCTURAL FIRE PROTECTION UNDER NEW EMERGENCY GENERATOR ROOM IN ACCORDANCE WITH 46 CFR 72.05-10(C).
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989
Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN NEW EMERGENCY GENERATOR ROOM. SIX B-II PORTABLE EXTINGUISHERS SHALL BE KEPT IN THE IMMEDIATE VICINITY OF THIS SPACE UNTIL THE FIXED SYSTEM IS OPERTIONAL AND APPROVED.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989
Resolved
REPAIR OR REPLACE KW METER IN MAIN SWITCHBOARD FOR THE #1 GENERATOR.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989
Resolved
REVISE FIRE CONTROL PLAN AND PROVIDE COPIES POSTED IN GALLEY, CREW'S QUARTERS, BOTH WHEELHOUSES, AND ENGINE ROOM CONTROL BOOTH.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Navigation
Issued 19 April 1989
Resolved
PROVIDE STEERING SYSTEM ALARMS IN ACCORDANCE WITH 46 CFR 77.03, 77.05, 111.93 AND 113.43.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Unknown
Issued 13 August 1988
Resolved
PROOVE PROPER OPERATION OF #2 END STEERING FLAT REMOTE BILGE SUCTION REACH ROD.
Condition: Unknown
Due 13 August 1988
Resolved 13 August 1988
Electrical
Issued 13 August 1988
Resolved
REMOVE DEAD END CABLE FROM #1 FWD VOID PORT SIDE.
Condition: Unknown
Due 13 August 1988
Resolved 13 August 1988
Engineering
Issued 29 October 1987
Resolved
REPLAE PVC PIPING FOR ENGINE COOLING WITH A METALLIC ALLOY AS PER 46 CFR 56.60-25(B).
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
CONDUCT FIRE AND BOAT DRILL WITH SHIP'S CREW IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Electrical
Issued 29 October 1987
Resolved
REPLACE MANUAL START EMERGENCY GENERATOR WITH AN AUTO START AS PER 46 CFR 112.05-5 AND 46 CFR 112.15-5.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Electrical
Issued 15 April 1987
Resolved
REPAIR LEAK TO NUMBER 2 GENERATORS WATER PUMP.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Construction/Loadline
Issued 15 April 1987
Resolved
REPAIR SUCTION LINE TO EMERGENCY BILGE PUMP JUST FORWARD OF PUMP.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Navigation
Issued 6 January 1987
Resolved
ADJUST RUDDER ANGLE INDICATOR OVER WINDOW IN AFT PILOT HOUSE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Lifesaving
Issued 6 January 1987
Resolved
CONDUCT BOAT DRILL WITH ASSIGNED CREW.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Documentation
Issued 6 January 1987
Resolved
HAVE VESSEL REFLECT NEW HOME PORT INSTEAD OF NEW BEDFORD.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 6 January 1987
Resolved
HAVE ANCHOR WINDLASS OPERABLE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Accommodation/Occupational Safety
Issued 6 January 1987
Resolved
PLACE VENT COVERS ON TWO GOOSENECK VENTS AFT OF FORWARD PILOT HOUSE.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Electrical
Issued 6 January 1987
Resolved
REPAIR NUMBER TWO AIR COMPRESSOR MOTOR.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Construction/Loadline
Issued 25 September 1986
Resolved
INSTALL PASSENGER LOADING DOOR ON PORTSIDE.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Construction/Loadline
Issued 25 September 1986
Resolved
REPAIR WASTED BOTTOM AREAS OF THE AFT PILOT HOUSE.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Construction/Loadline
Issued 25 September 1986
Resolved
REPAIR BOTTOM WASTED AREAS OF VEHICLE DOORS AT BOW AND STERN.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Construction/Loadline
Issued 25 September 1986
Resolved
REPLACE STARBOARD SIDE FORWARD LINE HANDLER DOOR.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Construction/Loadline
Issued 25 September 1986
Resolved
REPLACE TWO CRACKED GLASS PORT LIGHTS ON PORT SIDE OF VEHICLE DECK.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Unknown
Issued 1 March 1985
Resolved
PROVIDE GUARDS ON THE FOLLOWING MACHINERY: A. FUEL OIL TRANSFER PUMP COUPLING B. BILGE PUMP COUPLING C. EMERGENCY GENERATOR FAN
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Unknown
Issued 1 March 1985
Resolved
CONDUCT FIRE AND BOAT DRILLS WITH SHIP'S COMPANY IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Engineering
Issued 1 March 1985
Resolved
PROVIDE PROPER NAME PLATE DATA FOR FOUR (4) S/S AIR RECEIVERS AND AFFIX TO TANKS.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Electrical
Issued 1 March 1985
Resolved
MAKE REPAIRS TO ALARM SYSTEM FOR #2 GENERATOR AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Engineering
Issued 1 March 1985
Resolved
PROVIDE PRESSURE GUAGES MOUNTED ON FOUR (4) S/S AIR RECEIVERS.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Engineering
Issued 15 October 1984
Resolved
REPAIR LEAKING PIPE NIPPLE AT D.O. CENTRIFUGE DISCHARGE PIPING.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Unknown
Issued 15 October 1984
Resolved
OVERHAUL BALL CHECK VENTS OR PROVIDE COVERS FOR F.O. VENTS, UPPER DECK.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Unknown
Issued 15 October 1984
Resolved
REMOVE AND CLEAN EXCESSIVE OIL RESIDUE FROM ENGINEROOM BILGES.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Navigation
Issued 15 October 1984
Resolved
TIGHTEN RUDDER PACKING, FWD END. PUMP OUT EXCESS WATER FOR EXAM OF RUDDER TRUNK.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Fire Fighting
Issued 15 October 1984
Resolved
OVERHAUL AND PROVE SATISFACTORY OPERATIONS OF #1 AND #2 FIRE PUMP RELIEF VALVES.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Fire Fighting
Issued 15 October 1984
Resolved
ADJUST FIRE SCREEN DOORS AT SNACK BAR AREA TO UPPER DECK TO PROPERLY CLOSE AND LATCH.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Electrical
Issued 15 October 1984
Resolved
PROVIDE RECEPTICLE COVERS FOR ELECTRICAL OUTLETS AT SNACK BAR.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Lifesaving
Issued 15 October 1984
Resolved
REPAIR OR REPLACE 2 EA RING BOUY LIGHTS WITH BROKEN COVER SECURING LATCHES.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Construction/Loadline
Issued 15 October 1984
Resolved
ADJUST 2 WATERTIGHT DOORS IN BULKHEAD OF CREW QUARTERS AND GALLEY AREA TO PROPERLY SEAT AGAINST KNIFE EDGES.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Construction/Loadline
Issued 15 October 1984
Resolved
CLEAN AND OVERHAUL ALL MAIN VEHICLE DECK WATERTIGHT HATCHES.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Electrical
Issued 15 October 1984
Resolved
OVERHAUL MISC. LIGHT FIXTURES IN CREW QUARTERS IE: OVERHEAD LIGHT SHADES AND BUNK LIGHTS.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984