MAURY USCG vessel records Sign in
← All vessels

CONGER

CONGER is a 2000 tank ship. The Coast Guard has recorded 11 inspections since 2001, most recently in January 2011, along with 3 deficiencies and 1 operational control.

Records from 2001 to 2011. Most recent: inspection, 5 January 2011.

Built
2000
Last inspected
5 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9198771 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-4259

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2001–2011)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44067 - Convention (Subpart B), Gross Ton
65998 - Dead Weight, Ton
15985 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

5 January 2011 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3921313
24 March 2010 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3698233
14 March 2008 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3162293
16 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2933332
28 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2896627
27 March 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2896044
25 March 2007 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2894052
29 June 2004 COC-CHEM Annual · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2115482
2 January 2003 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1723164
16 January 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 286035
16 January 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1467718

Deficiency record · 3

Deck/Cargo › Cargo Stowage › General
Issued 24 March 2010 Resolved
Cargo sample locker. Samples were not stored properly, there were no cell dividers between cargo samples. Vessel is to install cell dividers in sample locker NLT 31MAR2010 and provide picture of work completed to MSU Galveston.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 26 March 2010
Resolution: Cell dividers have been added.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 27 March 2007 Resolved
Vessel's IGS is suspected of discharging fuel oil in the sea during operations and was stopped (secured from operations). Vessel is to cease cargo operations and demonstrate proper function of IGS prior to conduction cargo operations. Rectify prior to next port, to the satisfaction of Class and the Coast Guard
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2007
Resolution: Received Class and Tech Report stating repairs have been made and IGS is working properly.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 27 March 2007 Resolved
Vessels IGS is not to discharge oil into the sea during operations. Rectify prior to next port to the satisfaction of Class and the Coast Guard.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2007
Resolution: Received Class and Tech Report stating repairs have been made and IGS is working properly.

Ownership record