Records from 1984 to 1989. Most recent: inspection, 21 February 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
21 February 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1346917
4 March 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1028042
21 January 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024772
5 June 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021889
18 May 1987
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021887
22 May 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298044
25 April 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 987410
25 April 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301920
25 October 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992075
1 July 1985
Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978183
1 May 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1289473
17 May 1984
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 987409
Construction/Loadline
Issued 4 March 1988
Resolved
INSTALL A PIPE CAP ON THE UNUSED THROUGH HULL VALVE IN THE AFT COMPARTMENT PORT SIDE IN THE BOTTOM.
Condition: Unknown
Due 18 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 March 1988
Resolved
REMOVE ALL LOOSE UNUSED BOLTS IN WAY OF THE MISSING SPRAY RAIL IN THE BOW AND PLUG THE HOLES.
Condition: Unknown
Due 18 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 4 March 1988
Resolved
REPAIR THE LEAK IN THE SALT WATER SIDE OF THE TRANSMISSION OIL COOLER.
Condition: Unknown
Due 18 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 21 January 1988
Resolved
REPAIR THE ROTTEN AND BROKEN DECK PLANKING AND FRAMES IN THE MAIN DECK. INSURE ALL REPAIRS ARE AS ORIGINAL OR IN ACCORDANCE WITH RECOGNIZED STANDARDS.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988
Resolved
THE VESSEL BOTTOM PLANKING IS LEAKING IN THE AFT AREA UNDER AN OLD FUEL TANK. REPAIR THE LEAK AND PRESENT THE VESSEL FOR AN UNDERWAY INSPECTION.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Lifesaving
Issued 22 May 1986
Resolved
FOUR ADDITIONAL ADULT PFDS ARE REQUIRED PRIOR TO CARRYING OVER A TOTAL 0F 35 PERSONS, PASSENGERS AND CREW.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Electrical
Issued 22 May 1986
Resolved
THE 110 VAC GENERATOR IS OOC. REPAIR AND DEMONSTRATE ALL 110 VAC ELECTRIC ACCESSORIES.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Engineering
Issued 22 May 1986
Resolved
THE STERN TUBE STUFFING BOX PACKING NUT IS STRIPPED AND THE NUT CAN'T BE SECURED ON THE STUFFING BOX.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Construction/Loadline
Issued 22 May 1986
Resolved
THE VESSEL IS DESIGNATED AS A COCKPIT VESSEL AND AN ENCLOSED CABIN IS NECESSARY FOR THIS DESIGNATION. THE AFT DOORS HAVE BEEN REMOVED FROM THE DECKHOUSE. THEY MUST BE REINSTALLED PRIOR TO OPERATION CARRYING PASSENGERS.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Lifesaving
Issued 1 July 1985
Resolved
PROVIDE ON BOARD FIVE APPROVED PFD'S, UNTIL THIS REQUIREMENT IS MET A MAXI-MUM OF 34 TOTAL PERSON MAY BE CARRIED ON THE VESSEL.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Navigation
Issued 1 July 1985
Resolved
PROVIDE ON BOARD UP-TO-DATE CHARTS, NAVIGATION RULES, COAST PILOT AND TIDE TABLE IAW 46 CFR 185.20-35.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Construction/Loadline
Issued 1 May 1985
Resolved
MAKE REPAIRS TO FIRST DECK BEAM AFT OF HEAD BULKHEAD PORT SIDE AND SECOND DECK BEAM AFT OF HEAD BULKHEAD ON STARBOARD SIDE.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
PROVIDE PROPER BATTERY BOX FOR BATTERIES IN ER.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985