MAURY USCG vessel records Sign in
← All vessels

FREEDOM I

FREEDOM I is a 1949 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1984, most recently in June 2019, along with 90 deficiencies and 2 casualty investigations between 2007 and 2018.

Records from 1984 to 2019. Most recent: inspection, 25 June 2019.

Built
1949
Last inspected
25 June 2019
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9110
Flag
UNITED STATES
366969880, 367675950 (licence lapsed)
Maury page id
psix-42592

Inspections, by type

…with no type recorded11
Years with a record 33 calendar years (1984–2019)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.3 ft × 19.8 ft × 4.8 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ERIE, PA, UNITED STATES · built 1949
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALEXANDRIA BAY, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 15 May 2020 · expires 30 June 2021
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI2224MMSI 367675950 · cancelled · compulsorily equipped · granted 3 June 2015, cancelled 11 March 2025
WDB9110MMSI 366969880 · expired · compulsorily equipped · granted 10 August 2004, cancelled 11 October 2014
WJ9619MMSI not assigned · cancelled · compulsorily equipped · granted 30 September 1997, cancelled 7 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

25 June 2019 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6725930
19 September 2018 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6544218
8 September 2018 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6543999
18 July 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6481952
18 July 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6483723
25 July 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6219954
9 August 2016 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5967547
23 June 2016 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916443
15 July 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5186149
12 May 2014 Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4857394
24 May 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4313395
1 September 2010 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3839856
7 August 2008 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3299296
29 June 2007 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2993477
8 May 2006 Simplified Stability Test
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2643827
23 August 2005 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2475569
29 June 2004 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2115367
9 April 2004 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040789
16 October 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1929795
7 July 2003 Annual Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1838847
25 August 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1766420
13 August 2002 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1660924
13 June 2001 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1448240
23 May 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1604471
16 May 2000 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1413725
23 June 1999 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1402899
3 May 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 806945
12 April 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1123252
12 April 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1123255
12 February 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 792703
26 January 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1123727
5 November 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453520
9 October 1998 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1386429
17 July 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1381470
29 May 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1115435
21 May 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1463395
1 December 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 775938
8 May 1997 Drydock Extension
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1101606
6 May 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1419769
21 May 1996 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1087370
24 May 1995 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 775935
24 May 1995 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1111051
24 May 1995 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184563
9 March 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875375
14 April 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858748
9 March 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169001
12 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136315
10 April 1992 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247630
10 May 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938063
24 April 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249749
12 March 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907358
21 November 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906317
23 April 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908511
17 April 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928773
15 March 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919694
9 January 1990 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218728
4 January 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242577
26 October 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222127
17 October 1989 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348317
26 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207863
22 April 1988 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016176
16 April 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000202
21 October 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010394
6 May 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305584
10 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984550
12 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976572
19 October 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1282483

Deficiency record · 90

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 July 2018 Resolved
Found approximately a 3" diameter hole approximately 3" up from the bottom of the bilge on the stbd side of the aft engine room watertight bulkhead. A previous repair to a pipe was done last week. It appears, the maintenance personnel replaced a piece of bilge piping that was going through the aft engine room watertight bulkhead/fwd tank room watertight bulkhead. The maintenance personnel replaced the pipe but did not replace the bulkhead they cut out. Vessel rep had a welder come look at the hole while the MI was there. Due to the location of the hole in the bulkhead to the bottom of the bilge, we decided to put a "lap patch" on until next dry-dock(May 2019) where the a proper insert can be installed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 August 2018
Resolution: An insert was wleded in place.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2018 Resolved
Found fire pump inoperable. Vessel crew unable to make pump operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2018
Resolution: Fire pump impeller was replaced. Fire pump tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2018 Resolved
Lifejacket donning placard missing from main deck aft and 2nd deck lifejacket storage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2018
Resolved 2 August 2018
Resolution: Vessel rep installed life jacket donning placards.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 July 2018 Resolved
Required fire drills have not been logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2018
Resolved 2 August 2018
Resolution: Discussed drills with Master.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 18 July 2018 Resolved
Required abandon ship drills have not been logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2018
Resolved 2 August 2018
Resolution: Discussed drills with Master.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 July 2018 Resolved
Required man overboard drills have not been logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2018
Resolved 2 August 2018
Resolution: Discussed drills with Master.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 July 2018 Resolved
Missing required Light List for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 2 August 2018
Resolution: Copy of light list was placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 July 2018 Resolved
Missing required Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 2 August 2018
Resolution: Copy of coast pilot was placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 July 2018 Resolved
Missing copy of NavRules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 2 August 2018
Resolution: Copy of NavRules was placed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2018 Resolved
Bilge suction strainer was found to be clogged with debris in the tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 2 August 2018
Resolution: Tank compartment strainer was unclogged and bilge pump tested for dewatering. Tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2018 Resolved
Operating station fire extinguisher requires proper bracket. current bracket will not properly secrure fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 25 June 2019
Resolution: Vessel owner decided to take the vessel out of service.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 July 2018 Resolved
Oil soaked sorbent pads found in the engine room bilge. Vessel is required to remove all oil soaked rags/sorbents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2018
Resolved 2 August 2018
Resolution: All oil soaked rags have been removed from the engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2018 Resolved
Required fashlights(2) were found inoperable. Vessel is required 2 working flashlights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2018
Resolved 2 August 2018
Resolution: 2 new operational flashlights have been placed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2018 Resolved
Main engine battery terminals were found loose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2018
Resolved 2 August 2018
Resolution: Battery terminals have been tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 18 July 2018 Resolved
A 3" diameter hole was found rusted through the 3rd to the top step of the stair leading to the second deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2018
Resolution: Welder repaired rusted out step using an insert.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 July 2018 Resolved
Emergency tiller access cover was found not to be watertight. Deficiency will be corrected at next dry-dock(May 2019).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 25 June 2019
Resolution: Vessel owner decided to take the vessel out of service vs repair.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 July 2017 Resolved
Vessel did not have an emergency broadcast placard posted or on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 21 August 2017
Resolution: Vessel had proper FCC emergency braodcast placard installed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 July 2015 Resolved
Forepeak Hatch cover O-ring is damaged and requires replacement to ensure watertight integrity. 46 CFR 171.124(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 28 June 2016
Resolution: A new gasket is installed in the hatch cover.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 July 2015 Resolved
Vessel missing three (03) life jackets. Obtain, mark in accordance with 46 CFR §185.604, and place three (03) life jackets in service; an adult life jacket must be provided for each person carried onboard. 46 CFR §180.71(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2015
Resolved 25 August 2015
Resolution: Discrepancy corrected during inspection. Three (03) new PFDs properly marked and stowed.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 15 July 2015 Resolved
Replace plastic crate and wooden plank base of generator exhaust components with a permanent non-combustible material 46 CFR §182.15-20.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 9 August 2016
Resolution: Muffler is attached to a metal base plate.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 July 2015 Resolved
Diesel tank exhaust vents are missing flame arresters; install 30 x 30 mesh flame arresters 46 CFR §182.20-35
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 9 August 2016
Resolution: Screen installed on fuel tank vents.
Engineering › Bilge Water Management System › Valve
Issued 15 July 2015 Resolved
Lazarette bilge suction check valve frozen, repair and/or renew check valve 46 CFR §182.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 28 June 2016
Resolution: Valve operating properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 July 2015 Resolved
Top deck lighting and electrical outlet use exposed wire nuts. Install weatherproof junction box for exterior wire splices. 46 CFR §183.05-50(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 28 June 2016
Resolution: Wire nuts removed and proper connections made.
Electrical › Electrical Distribution System (service) › Conductor
Issued 15 July 2015 Resolved
Exposed dead ended wiring in forward interior corner area of main deck, portside just below overhead. Remove unused wiring and/or install junction box to contain connection. 46 CFR §183.05-50(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 28 June 2016
Resolution: Dead end wire removed.
Communications › Public Address System › Announcing Station
Issued 15 July 2015 Resolved
Vessel Public Address System out of service and/or missing, install as required by 46 CFR 184.610
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 28 June 2016
Resolution: New PA system installed.
Electrical › Lighting (service) › Lighting Feeder
Issued 24 May 2012 Resolved
Repair wiring to mast light. Ensure wiring cover extends at least 1/4" into plug receptacle and all exposed wiring repaired or replaced.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 10 July 2012
Resolution: Received photographic evidence from operation manager attesting to the satisfactory completion of requirement.
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2012 Resolved
Replace rotted grab line on life ring to the satisfaction of the attending CG inspector.
Action required: 705 - Other - as specified
Due 24 May 2012
Resolved 10 July 2012
Resolution: Received photographic evidence from operation manager attesting to the satisfactory completion of requirement.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 May 2012 Resolved
Make penetrations of the #4 and #6 upper transverse bulkheads where they meet the deck plate watertight. Temp installation of fire stop approved with permanent correction prior to the 2013 op season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2013
Resolved 3 September 2013
Resolution: Witnessed air test on welds to inserts in bulkheads. Repairs completed satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 24 May 2012 Resolved
Provide gauging report for hull plating within lazarette ( 2 shots per plate) and keel (2 shots per void).
Action required: 705 - Other - as specified
Due 1 May 2013
Resolved 3 September 2013
Resolution: Gauging report reviewed and accepted by MSD Massena. A copy of the gauging report was filed in the electronic and paper vessel file.
Engineering › Fuel Oil Service System › Valve
Issued 1 September 2010 Resolved
Prove proper operation of emergency fuel shutoff prior to commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Resolution: Received notification from master that remote arm secured to valve with handle provided. Verified operation during visit on 9/8/10
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 September 2010 Resolved
Provide 5 adult life jackets with appropriate marking and retro-reflective tape. Until replaced vessel is limited to 126 passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Resolution: Received notification from master that 5 replacement life jackets have been replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 1 September 2010 Resolved
Mount fire extinguisher in way of serving area. (7 days)
Action required: 705 - Other - as specified
Due 8 September 2010
Resolved 2 September 2010
Resolution: Received notification from master that extinguisher bracket mounted.
Engineering › Bilge Water Management System › Not Operational
Issued 1 September 2010 Resolved
Prove proper operation of bilge high water alarm for the # 4 void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Resolution: Received notification from master that high level alarm replaced. Verified operation during visit 8th.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2010 Resolved
Remove extension cord in way of serving area & provide electrical box to service area.
Action required: 705 - Other - as specified
Due 29 September 2010
Resolved 29 June 2011
Resolution: Hard wire outlet provided at serving area.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 September 2010 Resolved
Remove AD battery bank atop fuel tank and replace box; clean tank top & provide gauge report. Provide report, appropriate corrective action plan prior to the 2011 operating season.
Action required: 705 - Other - as specified
Due 2 May 2011
Resolved 29 June 2011
Resolution: Battery bank removed from location and provided new installation to port of tank with appropriate structures and adequate protection.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 7 August 2008 Resolved
Identify/Repair/Clean sewage leak in tank space.
Due 22 August 2008
Resolved 20 May 2009
Resolution: Verified repairs made to sewage tank. All sat.
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 August 2008 Resolved
Properly mount P/W pump.
Due 22 August 2008
Resolved 20 May 2009
Resolution: P/W pump properly mounted. All sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 August 2008 Resolved
Secure port upper deck bench, broken support screws.
Due 7 August 2008
Resolved 7 August 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 August 2008 Resolved
Repair engine pulley guard , broken welds caused by PTO shift linkage.
Due 22 August 2008
Resolved 20 May 2009
Resolution: Pulley guard properly attached. All sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 August 2008 Resolved
Properly mount E/R fire extinguisher in bracket.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 22 May 2009
Resolution: F/E properly mounted.
Stability › Incline Test › General
Issued 23 August 2005 Resolved
Stability test performed in 1979 does not address max number of passengers on top deck.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 June 2006
Resolution: Owner performed stability test using the recommended 185 lbs per passenger.
Fire Fighting › Fire Hydrants › Location/Position
Issued 29 June 2004 Resolved
Install a fire hydrant on the upper deck so the pilot house can be reached with a single length of hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 26 August 2005
Resolution: Installed new hydrant.
Construction/Loadline › Hull
Issued 9 April 2004 Resolved
In transom gauge holed area and either plug weld or insert with minimum size of 18' x 18' .
Due 9 April 2004
Resolved 10 May 2004
Construction/Loadline › Structures
Issued 9 April 2004 Resolved
Crop and renew forward bulkhead port side as marked approximately 18' x 18'. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 9 April 2004
Resolved 10 May 2004
Construction/Loadline › Structures
Issued 9 April 2004 Resolved
Aft bulkhead portside of waste compartment is gouged vee and weld area in way of second long from center. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 9 April 2004
Resolved 10 May 2004
Engineering › Bilge Water Management System
Issued 9 April 2004 Resolved
Replace missing strainer on bilge suction line comparment #2. LEGACY COMPONENT DESC: Strainer
Due 9 April 2004
Resolved 10 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 July 2003 Resolved
Prove proper operation of MDE shutdown from the operation station. LEGACY COMPONENT DESC: Engine shutdown
Due 7 August 2003
Resolved 8 August 2003
Resolution: Tested sat.
Navigation › Piloting/Steering
Issued 7 July 2003 Resolved
Callibrate compass to reduce deviation. LEGACY COMPONENT DESC: Compass Deviation Table
Due 7 August 2003
Resolved 8 August 2003
Resolution: Sighted card
Electrical › Electrical Distribution System (service)
Issued 7 July 2003 Resolved
Remove multi plug adaptor on bridge. LEGACY COMPONENT DESC: Wiring
Due 7 August 2003
Resolved 8 August 2003
Resolution: O/O installed outlet on bridge
Accommodation/Occupational Safety › Occupational Safety
Issued 7 July 2003 Resolved
secure cash register and coffee pot at the snack bar. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Due 7 August 2003
Resolved 8 August 2003
Resolution: secured
Navigation › Collision/Grounding Avoidance
Issued 7 July 2003 Resolved
Prove proper operation of mast lights. LEGACY COMPONENT DESC: Navigation Lights
Due 7 August 2003
Resolved 8 August 2003
Resolution: Tested sat
Electrical › Electrical Distribution System (service)
Issued 7 July 2003 Resolved
Provide cover for elec outlet on main dk fwd bulkhead LEGACY COMPONENT DESC: Wiring
Due 7 August 2003
Resolved 8 August 2003
Resolution: sighted
Electrical › Electrical Distribution System (service)
Issued 7 July 2003 Resolved
Provide metal wire ties for bridge wires. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 7 August 2003
Resolved 8 August 2003
Resolution: installed
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 July 2003 Resolved
Provide 6 life jackets for the ones removed from service. LEGACY COMPONENT DESC: Quantity
Due 7 August 2003
Resolved 8 August 2003
Resolution: Provided
Engineering › Lubricating Oil Service System
Issued 7 July 2003 Resolved
Prove proper operation of SSDG oil pressure gauge. LEGACY COMPONENT DESC: Gauge
Due 7 August 2003
Resolved 8 August 2003
Resolution: Tested sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 July 2003 Resolved
Prove proper operation of MDE oil pressure gauge. LEGACY COMPONENT DESC: Oil pressure gauge
Due 7 August 2003
Resolved 8 August 2003
Resolution: Tested sat
Accommodation/Occupational Safety › Ventilation
Issued 7 July 2003 Resolved
Fix main deck windows so they are in the track. LEGACY COMPONENT DESC: Windows
Due 7 August 2003
Resolved 8 August 2003
Resolution: All windows are in the track
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 July 2003 Resolved
Prove proper operation of fuel oil shut downs. LEGACY COMPONENT DESC: Fuel oil shut downs
Due 7 August 2003
Resolved 8 August 2003
Resolution: Tested sat
Construction/Loadline › Structures
Issued 7 July 2003 Resolved
Repair holes in main deck IWO strb side head. LEGACY COMPONENT DESC: Deck Plating
Due 30 November 2003
Resolved 16 October 2003
Resolution: Examened approx. 24"X24" insert, sat
Accommodation/Occupational Safety › Occupational Safety
Issued 7 July 2003 Resolved
Repair fwd hand rail to the forepeak LEGACY COMPONENT DESC: Deck Rail
Due 30 November 2003
Resolved 16 October 2003
Resolution: Rail rewelded
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 July 2003 Resolved
Repair exhust leak on MDE LEGACY COMPONENT DESC: Piping (exhaust)
Due 30 November 2003
Resolved 16 October 2003
Resolution: Muffler replaced, sat
Documentation › Logs/Records
Issued 13 August 2002 Resolved
Make a passenger count available at the vessel's berth or with company representative ashore prior to each voyage. LEGACY COMPONENT DESC: Passenger Count
Due 27 August 2002
Resolved 20 August 2002
Engineering › Lubricating Oil Service System
Issued 13 August 2002 Resolved
Provide main engine lube oil pressure gauge at operating station LEGACY COMPONENT DESC: Gauge
Due 27 August 2002
Resolved 20 August 2002
Communications › Internal Communications System
Issued 13 August 2002 Resolved
Provide a means of communication between the wheelhouse and the engine room
Due 27 August 2002
Resolved 20 August 2002
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 13 August 2002 Resolved
Adjust stuffing box
Due 27 August 2002
Resolved 13 August 2002
Navigation
Issued 16 May 2000 Resolved
Provide compass light.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
Route restricted to warm water operation until primary lifesaving is provided, or rivers not more than 1 mile from shore. 2 of 3 BA's failed float test and O/O does not plan to replace them.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Provide MDE tach to the bridge.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
Remove extension cord from bridge to eng. room.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Engineering
Issued 16 May 2000 Resolved
Replace raw water hoses on MDE & SSG.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Construction/Loadline
Issued 23 June 1999 Resolved
PROVIDE DRAFT MARKS AS REQUIRED BY STABILITY LETTER.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Accommodation/Occupational Safety
Issued 23 June 1999 Resolved
PROVIDE PROPER RAIL COURSES IAW 46 CFR 177.900.
Condition: Unknown
Due 23 July 1999
Resolved 10 August 1999
Lifesaving
Issued 23 June 1999 Resolved
PROVE THAT THE BUOYANT APPRATUS (3) ARE STILL IN GOOD AND SERVICABLE CONDITION BY BUOYANT TESTING FOR THE RATED CAPACITY OR REPLACE.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Lifesaving
Issued 23 June 1999 Resolved
PROVIDE PROTECTION FROM ROTATING MACHINERY (MDE).
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Lifesaving
Issued 23 June 1999 Resolved
PROVIDE AN APPROVED FIRST AID KIT.
Condition: Unknown
Due 23 July 1999
Resolved 10 August 1999
Construction/Loadline
Issued 5 November 1998 Resolved
CROP AND RENEW WASTED DECK PLATING PORTSIDE, ADJACENT TO MENS HEAD. NO PASSENGERS FOR HIRE UNTIL CLEARED._x001C_
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998 Resolved
REPLACE CUTOUT SECTION OF DECH OVER COMPT. #5. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998 Resolved
CROP AND RENEW AREAS UNDER MENS AND WOMENS HEADS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998 Resolved
SHOW PROPER OPERATION OF BILGE SYSTEM. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 29 May 1998 Resolved
Install gasket around hatch cover to forepeak, such that forepeak will be watertight. Meet this requirement to the satisfaction of attending marine inspector, NLT 15 June 1998.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Construction/Loadline
Issued 21 May 1998 Resolved
REDRYDOCK VESSEL AND COMPLETE RENEWAL OF MARGINAL BOTTOM PLATING. VESSEL'SOPERATIONS RESTRICTED AS PER [name withheld] LTR DTD 4MAY98 UNTIL PLATE RENEWAL COMPLETED.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 6 May 1997 Resolved
PROVIDE PROPER DOCUMENTATION OF A FULLY COMPLIANT CHEMICAL TESTING PROGRAM
Condition: Unknown
Due 6 June 1997
Resolved 20 May 1997
Lifesaving
Issued 21 May 1996 Resolved
Repair lifefloats. Vessel is restricted to operating not more than 1 mile from shore until completed to the satisfcation of a CG marine inspector.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Lifesaving
Issued 10 April 1992 Resolved
PROVIDE SIX (6) ADULT LIFEJACKETS TYPE 1 CG APPROVED. VESSEL IS RESTRICTEDTO 144 TOTAL PERSONS UNTIL SATISFACTORY COMPLIANCE WITH THIS REOUIREMENT.
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Lifesaving
Issued 24 April 1991 Resolved
PROVIDE 27 ADULT TYPE I PFD'S. MUST BE INSPECTED AND STAMPED APPROVED BY CG INSPECTOR. THIS REQUIREMENT TO BE COMPLETED PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 24 May 1991
Resolved 18 July 1991
Electrical
Issued 24 April 1991 Resolved
PROVIDE A TRAY FOR BATTERIES IN ACCORDANCE WITH 46CFR183.05-20(D).
Condition: Unknown
Due 24 May 1991
Resolved 18 July 1991
Construction/Loadline
Issued 17 April 1990 Resolved
REPAIR LEAKING FITTING ON PROPELLOR SHAFT STUFFING BOX.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990 Resolved
PROVIDE TWO USCG-APPROVED TYPE I ADULT LIFE PRESERVERS
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Construction/Loadline
Issued 17 April 1990 Resolved
REPAIR FRACTURED TRANSVERSE FRAME AT JOINT TO KEELSON IN AFT STEERING COMPARTMENT
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Construction/Loadline
Issued 17 October 1989 Resolved
DECK PLATING OVER FOREPEAK PERFORATED AROUND MANHOLE AND HAWSEHOLE, CROP TOGOOD STEEL AND RENEW PLATING AS NECESSARY; INSURE ADEQUATE FOREPEAK COMPARTMENT VENTILATION.
Condition: Unknown
Due 17 October 1989
Resolved 17 October 1989

Casualty record · 2

29 June 2007Routine · role: Involved in a Marine Casualty · activity 2993477
8 September 2018Routine · role: Involved in a Marine Casualty · activity 6543999
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record