Records from 1996 to 1998. Most recent: inspection, 9 June 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 9 June 1998
Resolved
CONDUCT AND LOG SATISFACTORY TEST OF TOTAL EMERGENCY RIG SHUT-DOWN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Lifesaving
Issued 9 June 1998
Resolved
PROVIDE LAUNCHING INSTRUCTIONS AND PERSONNEL CAPACITY AND LIFERAFT NUMBER AT LIFERAFT STATIONS.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Fire Fighting
Issued 9 June 1998
Resolved
CONDUCT ANNUAL CALIBRATION OF O2/LEL METERS.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Lifesaving
Issued 9 June 1998
Resolved
ENSURE BUNK IN HOSPITAL SPACE IS ACCESSIBLE FROM BOTH SIDES.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Fire Fighting
Issued 9 June 1998
Resolved
CONDUCT HYDROSTATIC TEST ON ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS THAT ARE OVERDUE.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Fire Fighting
Issued 9 June 1998
Resolved
ENSURE STAIRWELL AND GALLEY DOORS SELF-CLOSE AND LATCH.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Lifesaving
Issued 9 June 1998
Resolved
INSTALL CAGES AROUND ALL EXTERIOR VERTICAL LADDERS GREATER THAN 20 FT.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Lifesaving
Issued 9 June 1998
Resolved
SUBMIT TO [name withheld] A COPY OF AN EXEMPTION LETTER FROM FLAG ADMINISTRATION STATING THAT THE VESSEL IS EXEMPT FROM CARRYING LIFEBOATS.
Condition: Unknown
Due 27 June 1998
Resolved 2 July 1998
Lifesaving
Issued 16 June 1997
Resolved
PROVIDE STANDARD SOLAS OILY WASTE DISCHARGE CONNECTION.
Condition: Unknown
Due 16 July 1997
Resolved 21 July 1997
Fire Fighting
Issued 16 June 1997
Resolved
PROPERLY LABEL ALL ALARM LIGHTS AND ALARMS.
Condition: Unknown
Due 30 June 1997
Resolved 19 June 1997
Lifesaving
Issued 16 June 1997
Resolved
REPAIR/REPLACE WIRE CABLE AT PORT SIDE LIFE RAFT RELEASE HOOK.
Condition: Unknown
Due 16 July 1997
Resolved 21 July 1997
Deck/Cargo
Issued 16 June 1997
Resolved
PROVIDE CLASS SURVEY REPORT ON BULK TANKS, FOUNDATIONS, AND PIPING.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Electrical
Issued 16 June 1997
Resolved
REPAIR INOPERABLE EMERGENCY A/C SHUT OFF SWITCH FOR QUARTERS.
Condition: Unknown
Due 16 July 1997
Resolved 21 July 1997
Electrical
Issued 16 June 1997
Resolved
REPLACE BURNED OUT LIGHTS ON HELO DECK. BOLT DOWN LOOSE FIXTURES.
Condition: Unknown
Due 30 June 1997
Resolved 20 June 1997
Navigation
Issued 16 June 1997
Resolved
REPAIR/REPLACE INOPERABLE FOG HORN (UPPER SECTION).
Condition: Unknown
Due 16 July 1997
Resolved 21 July 1997
Lifesaving
Issued 16 June 1997
Resolved
REPAIR/REPLACE WORN/WASTED PERSONNEL HOIST BASKET.
Condition: Unknown
Due 16 July 1997
Resolved 19 June 1997
Lifesaving
Issued 16 June 1997
Resolved
PROVIDE FLOOR BOARDS, REPAIR KIT, TOWLINE (100'), 2 CG APPROVED FLASHLIGHTS. RENEW GRAB LINES.
Condition: Unknown
Due 30 June 1997
Resolved 21 July 1997
Fire Fighting
Issued 16 June 1997
Resolved
PROVIDE FULLY CHARGED CO2 BOTTLE IN ENGINEROOM FIXED CO2 SYSTEM.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Electrical
Issued 16 June 1997
Resolved
REPAIR/REPLACE SHAKER MOTOR SWITCH WITH PROPER EXPLOSION PROOF SWITCH WITH COVERS.
Condition: Unknown
Due 30 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 16 June 1997
Resolved
PROVIDE REPAIR PROPOSAL FOR WASTED SECTIONS OF SALT WATER PIPING. COMPLETEREPAIRS BY 24JUN97. CLASS SOCIETY TO SURVEY REPAIRS.
Condition: Unknown
Due 24 June 1997
Resolved 21 July 1997
Electrical
Issued 8 July 1996
Resolved
REPLACE ALL CRACKED CRANK CASE VENT LINES FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
PLACE FLOOD LIGHT FOR PORTSIDE LIFERAFT STATION ON EMERGENCY BUS CIRCUIT.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
INSTALL BATTERY POWERED EMERGENCY LIGHTS IN FOLLOWING AREAS: IN STAIRWAY GOING TO CONTROL ROOM, NEAR WATERTIGHT DOOR TO GALLEY, & AT BOTH LIFERAFT STATIONS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
REPLACE WASTED FOUNDATION FOR #1 FIRE/DRILL WATER PUMP.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
LABEL SWITCHES FOR ALL FIRE/DRILL WATER PUMPS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
REPLACE LEAKING PRIME VALVE TO #2 FIRE/DRILL WATER PUMP.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
REPLACE PRESSURE GAUGES FOR #2 & #3 FIRE/DRILL WATER PUMPS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
PROVE NEGATIVE PRESSURE OF MUDPIT VENTILATION SYSTEM.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
REPLACE WASTED CABLE TRAY & CLAMP LOOSE CABLES ON FORWARD BULKHEAD OF MNUDPIT ROOM.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Engineering
Issued 8 July 1996
Resolved
INSTALL 30 BY 30 INCH MESH FLAME SCREEN FOR MAINDECK DEISEL OIL GOOSENECK VENT BY STBD LEG.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Documentation
Issued 8 July 1996
Resolved
PROVIDE LETTER FROM FLAG STATE ON ALL EXEMPTIONS TO IMO MODU CODE.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996
Resolved
PROVIDE CORRECT DAVIT OPERATING & LAUNCHING INSTRUCTIONS FOR BOTH LIFERAFT STATIONS; REMOVE ALL OTHERS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Documentation
Issued 8 July 1996
Resolved
PROVIDE FINAL CERTIFICATES FOR FOLLOWING: IMO MODU CODE SAFTEY, IOPP, & LOADLINE.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
ENSURE ALL EMERGENCY LIGHTING FIXTURES ARE APPROPRIATELY STENCILED WITH "E".
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996
Resolved
PRIOR TO DRILLING, INSTALL GAS DETECTION SYSTEM IN SHAKER HOUSE.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Electrical
Issued 8 July 1996
Resolved
PROVIDE MISSING GLASS PANES FOR BOTH REMOTE CO2 PULLS & TOTAL RIG SHUTDOWN STATION ON DRILL FLOOR.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
RELOCATE FIREMAN'S OUTFIT LOCATED IN MOTOR ROOM.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
PROVIDE OPERATING INSTRUCTIONS & BLOCK DIAGRAM AT CO2 CYLINDERS FOR MOTOR ROOM & AUXILIARY PUMP ROOM.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
REVISE & SUBMIT FIRE CONTROL PLAN TO ABS FOR APPROVAL.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996
Resolved
LABEL ALL ALARMS IN MUDPUMP & MUDPIT ROOMS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996
Resolved
PROVIDE MISSING WATER BOTTLES FOR EYE WASH STATION IN MUDPIT ROOM.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Construction/Loadline
Issued 8 July 1996
Resolved
PRIOR TO DRILLING, MAKE ALL AUTOMATIC CLOSING DOORS TO MUDPIT ROOM GAS TIGHT.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
INSTALL FOAM EXTINGUISHING SYSTEM & ALTERNATE (2ND) HOSE STATION FOR HELODECK OR SUBMIT TO MSO PORT ARTHUR COPY OF FLAG STATE EXEMPTION LETTER FOR THE PRESENT ARRANGEMENT.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Fire Fighting
Issued 8 July 1996
Resolved
FOR PAINT LOCKER, PERMANENTLY CLOSE FORWARD VENT & PROVIDE LOCKING MECHANISM FOR AFT CLOSURE.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996