Inspection history · 21
31 August 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8005263
9 July 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7954363
27 July 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7799615
28 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7726534
13 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667862
7 December 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7604903
10 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7594147
7 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7591657
21 April 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7431720
21 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7262289
21 December 2020
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7114929
14 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7000521
9 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834181
18 July 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6753676
12 December 2018
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596451
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538971
19 July 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6484220
14 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6124531
2 January 2017
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064712
24 October 2016
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6028447
20 June 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5913132
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024
Resolved
Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. MI found 01 battery on the port side that was covered in salt and not secured properly. Remove all salt and secure in accordance with current regulations.
46 CFR 183.354
50c- Rectify deficiencies w/in 30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2024
Resolution: observed portside batteries cleaned of salt and properly secured
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found S/W strainer in the E/R aft port side was not properly secured. Secure in accordance with current regulations.
46 CFR 176.830
50c-Rectify deficiencies w/in 30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2024
Resolution: observed aft portside sea strainer secured
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found starboard MDE machine guard was removed. Reinstall in accordance with current regulations.
46 CFR 177.960
50c-Rectify deficiencies w/in 30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2024
Resolution: observed STBD machinery guard, in place
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found hydraulic hose was rubbing on MDE that was missing machinery guard causing the hose to chaff. Replace hose in accordance with current regulations.
46 CFR 176.830
17c-Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2024
Resolution: Machinery guard in-place to prevent chaffing of hydraulic hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI found a leaky fuel hose on the # 2 MDE. Fix leak in accordance with current regulations.
46 CFR 176.804
17c- Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2024
Resolution: repairs made on leaky fuel return on #2MDE
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. MI found that 1 of the switchboard in the E/R aft port side had missing breakers covered in electrical tape. Remove and place correct breaker blanks in panel in accordance with current regulations.
46 CFR 183.330
50c-Rectify deficiencies w/in 30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2024
Resolution: Plastic plank was installed to non-existing breaker
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 July 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The fixed fire extinguishing installation shutdown for the genset failed testing. Repair the shutdown mechanism for the genset.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: Witnessed a satisfactory test of the shutdown. The vessel POC explained that following maintenance of the solenoids to the system, a wire had gotten loose causing the shutdown to fail. Re-tightening the wire corrected the issue.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020
Resolved
Provide generator and shore power breakers with interlock device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2020
Resolution: Vessel rep installed a functional interlock device.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020
Resolved
Label all breakers in the engine room electrical panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2020
Resolution: Vessel rep labeled all panel breakers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 July 2020
Resolved
Securely mount generator sea strainer and provide double hose clamps on both sides of pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Sea strainer was securely fastened metal banding and double hose clamps were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020
Resolved
Securely mount bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Bilge pump was properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020
Resolved
Provide hose clamp for port gear box cooler hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Hose clamp was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020
Resolved
Securely mount starboard main engine sea strainer and connected coolers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Sea strainer was securely mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020
Resolved
Securely mount spare bait pump and motor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Spare bait pump was securely mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 July 2020
Resolved
Securely mount toilet water pump and motor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Toilet water pump was securely mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 July 2020
Resolved
Remove epoxy and repair leaking freeze plugs on starboard main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 24 August 2020
Resolution: Epoxy was removed and freeze plugs were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 9 January 2020
Resolved 24 August 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Electrical › Lighting (service) › Lighting Fixture
Issued 25 April 2017
Resolved
Replace light covers in E/R.
Condition: Placed in Improper Service
Due 25 May 2017
Resolved 25 May 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 25 April 2017
Resolved
Secure Sea stariner for generator
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 April 2017
Resolved
Provide voltmeter, ammeter and hertz meter for generator
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 25 April 2017
Resolved
Repair leak on portside sea stariner
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 May 2017
Electrical › Electric Generation Source (service) › Generator Cable
Issued 25 April 2017
Resolved
Remove wire nuts on cable above port engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 25 May 2017