Records from 1986 to 1987. Most recent: inspection, 25 August 1987.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation
Issued 24 June 1986
Resolved
PROVIDE OPERATIONAL TEST OF RADAR, PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 10 July 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 24 June 1986
Resolved
PROVIDE 11 ADULT AND 2 CHILD PFD'S WHERE MISSING. THE VESSEL IS NOW ALLOWEDTO CARRY NO MORE THAN 29 ADULTS AND 2 CHILDREN UNTIL THE PFD'S ARE REPLACED
Condition: Unknown
Due 10 July 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 24 June 1986
Resolved
REPAIR LEAK IN RUDDER POST (PACKING GLAND) LEAKING PROFUSELY.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Navigation
Issued 24 June 1986
Resolved
PROVIDE OPERATIONAL TEST OF RADAR, PRESENTLY OUT OF COMISSION.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Fire Fighting
Issued 24 June 1986
Resolved
RECHARGE AND HYDRO-TEST 1-15#CO2 PORTABLE FIRE EXTINGUISHER, PRESENT HYDRO DATE 1/73.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Fire Fighting
Issued 24 June 1986
Resolved
RECHARGE OR REPLACE 1-2 3/4#DC PORTABLE FIRE EXTINGUISHER, WHERE DISCHARGED
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Lifesaving
Issued 24 June 1986
Resolved
REPLACE 16 ADULT AND 4 CHILD PFD'S, WHERE TORN OR DETERIORATED.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Lifesaving
Issued 24 June 1986
Resolved
REPLACE ALL GRAB LINES ON BUOYANT APPARATUS WHERE DETERIORATED.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Construction/Loadline
Issued 24 June 1986
Resolved
PROVIDE DOGGING DEVICE AND CAPTVE CHAINS ON 2 WATERTIGHT HATCHES, ON MAIN DECK, WHERE MISSING.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Lifesaving
Issued 24 June 1986
Resolved
MARK SIZE AND AMOUNT OF ALL PFD'S ON STOWAGE COMPARTMENTS, WHERE MISSING.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Accommodation/Occupational Safety
Issued 24 June 1986
Resolved
PROVIDE HIGH AND LOW NATURAL VENT, IN CRASH COMPARTMENT, WHERE MISSING.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Electrical
Issued 24 June 1986
Resolved
REMOVE ALL WIRE NUTS FROM ELECTRICAL WIRING ON BRIDGE, AND MECHANICALLY SECURE SAME.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Navigation
Issued 24 June 1986
Resolved
PROVIDE MAGNETIC COMPASS, WHERE MISSING.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Electrical
Issued 24 June 1986
Resolved
PROVIDE OPERATIONAL TEST OF SIGNAL STRENGTH INDICATOR, WHERE MISSING.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Deck/Cargo
Issued 24 June 1986
Resolved
PROVIDE OPERATIONAL TEST OF ANCOR WINCH, PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986