MAURY USCG vessel records Sign in
← All vessels

COVE NAVIGATOR *

COVE NAVIGATOR * is a 1951 tank ship. The Coast Guard has recorded 15 inspections since 1980, most recently in November 1985, along with 22 deficiencies.

Records from 1980 to 1985. Most recent: inspection, 6 November 1985.

Built
1951
Last inspected
6 November 1985
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5029271 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-42644

Inspections, by type

…with no type recorded14
Years with a record 6 calendar years (1980–1985)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 41 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)628.4 ft × 85.3 ft × 45.2 ft
Registered tonnagegross 19,498 / net 11,929
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · CAMDEN N.J. · built 1951
Hull materialSteel
PropulsionSteam Turbine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationInvalid
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11929 - Regulatory (Subpart C or D), Net Ton
30155 - Dead Weight, Ton
19498 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

6 November 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1296022
15 September 1985 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1297679
26 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1288024
25 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284394
18 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974522
17 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 298515
27 December 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1278861
23 December 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 970719
16 November 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 970718
11 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968580
5 October 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277012
12 May 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 968946
4 September 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1271403
31 August 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965970
21 August 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273493

Deficiency record · 22

Construction/Loadline
Issued 15 September 1985 Resolved
REPLACE ALL BROKEN PARTS THRUOUT VESSEL.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 September 1985 Resolved
CROP AND RENEW WASTED FORWARD DECK HOUSE BULKHEAD IN WAY OF CEMENT PATCH AT CREW'S LOUNGE. REPAIR OTHER IMPROPER PENETRATIONS.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 September 1985 Resolved
REPLACE BROKEN BRIDGE WINDOW.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 September 1985 Resolved
REPLACE OR REPAIR RUDDERS FOR #1 AND #4 LIFEBOATS.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 15 September 1985 Resolved
PRIOR TO LEAVING NEXT PORT OF CALL, ST. ROSE, LA, PROVIDE FOR REPLACEMENT OF 320 GALLONS OF 6% FOAM FOR FIXED FOAM TANK.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 15 September 1985 Resolved
DUE TO INSUFFICIENT PFD'S ABOARD, MANNING REDUCED TO 15 OTHERS IN CREW, 0 PERSONS IN ADDITION TO CREW, FOR A TOTAL OF 36 PERSONS ALLOWED.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 15 September 1985 Resolved
UNTILL DEMONSTRATION OF BOILER MANAGEMENT SYESTEM TO SATISFACTION OF A MARINE INSPECTOR, CREW IS INCREASED TO HAVE AN ADDITION OF 3 FIREMEN ON BOARD, 12 OTHERS IN CREW, FOR A TOTAL OF 36 PERSONS ALLOWED.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 September 1985 Resolved
REPLACE ROTTMEN GEAR HOOK MOUNTING BOLTS ON #3 LIFEBOAT AND WEIGHT TEST FORA MARINE INSPECTOR.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 September 1985 Resolved
CROP AND RENEW WASTED BULKHEAD BELOW PORT SIDE AFT DOOR OF FORWARD HOUSE ONMAIN DECK LEVEL.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 15 September 1985 Resolved
REPLACE PATCHED PVC DRAIN PIPING OVER MAIN SWITHBOARD WITH JOINTLESS METALLIC PIPING.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 September 1985 Resolved
CROP AND RENEW WASTED DECK IN SHAFT ALLEY OVERHEAD NEAR ESCAPE TRUNK SCUTTLE HATCH.
Condition: Unknown
Due 23 December 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 October 1984 Resolved
PROVIDE TWO ADDITIONAL FIREMANS OUTFITS TO MAKE A TOTAL OF FOUR ON BOARD.
Condition: Unknown
Due 18 October 1984
Resolved 18 October 1984
Fire Fighting
Issued 18 October 1984 Resolved
PROVIDE DUPLICATE SET OF FIRE CONTROL PLANS OR BOOKLET FOR DISPLAY AT THE GANGWAY OR OUTSIDE OF THE DECK HOUSE.
Condition: Unknown
Due 18 October 1984
Resolved 18 October 1984
Navigation
Issued 18 October 1984 Resolved
UPDATE SHIPS DEVIATION TABLE.
Condition: Unknown
Due 18 October 1984
Resolved 18 October 1984
Unknown
Issued 27 December 1983 Resolved
PROVIDE ON BOARD AN APPROVED OIL WATER INTERFACE DETECTOR AS REQUIRED BY MARPOL 73/78 REGULATION 15 (3)(B)
Condition: Unknown
Due 27 December 1983
Resolved 27 December 1983
Construction/Loadline
Issued 23 December 1983 Resolved
MAKE PERMANENT REPAIRS TO THE EXTERIOR DOOR TO THE CREWS LOUNGE IN THE AFT QUARTERS HOUSE.
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Lifesaving
Issued 23 December 1983 Resolved
PROVIDE A MOTOR LIFEBOAT FOR #2 LIFEBOAT SER.# 674. THE UNATHORIZED LIFEBOAT REPLACEMENT WAS NOT IN COMPLYANCE WITH 46 CFR 33.05-1(D)
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Construction/Loadline
Issued 23 December 1983 Resolved
REPAIR THE AFT PUMPROOM BILDGE PUMP AND TEST SAME IN PRESENTS OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 December 1983
Resolved 23 December 1983
Documentation
Issued 4 September 1981 Resolved
PROVIDE AN APPROVED PLAN AND INSTALLATION TO COMPLY WITH 33 CFR 164.39, "IMPROVED STEERING GEAR STANDARDS FOR TANK VESSELS"
Condition: Unknown
Due 1 February 1982
Resolved 4 September 1981
Deck/Cargo
Issued 4 September 1981 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 4 September 1981
Resolved 4 September 1981
Lifesaving
Issued 4 September 1981 Resolved
STENCIL ALL GENERAL ALARM BELLS AND CONTACT MAKERS IN ACCORDANCE WITH APPLICABLE REGULATIONS.
Condition: Unknown
Due 12 May 1982
Resolved 4 September 1981
Documentation
Issued 4 September 1981 Resolved
SUBMITT FOR APPROVAL A FIRE PLAN WHICH REFLECTS ALL SHIPBOARD FIRE FIGHTINGSYSTEMS AS INSTALLED.
Condition: Unknown
Due 12 May 1982
Resolved 4 September 1981

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.