Records from 1984 to 2004. Most recent: inspection, 30 August 2004.
Documentation record
Registered dimensions (L × B × D)229.4 ft × 42.9 ft × 14.5 ft
Registered tonnagegross 1,278 / net 1,278
ITC dimensions (L × B × D)219.2 ft × 43.0 ft × 14.5 ft
ITC tonnagegross 1,303 / net 390
BuilderBETHLEHEM STEEL CO · MARINERS HARBOR NY, UNITED STATES · built 1951
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPALATKA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 24 January 2011 · expires 29 February 2012
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1278 - Regulatory (Subpart C or D), Net Ton
390 - Convention (Subpart B), Net Ton
1278 - Regulatory (Subpart C or D), Gross Ton
1303 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
30 August 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2180955
19 May 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 74111
11 November 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 134773
16 November 1992
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1133271
13 November 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215453
17 October 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 895441
3 October 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329058
19 December 1988
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1035079
14 October 1988
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 890548
11 February 1988
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1331270
2 October 1987
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1004575
6 February 1987
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1015996
25 October 1986
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1320513
9 October 1986
Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1016066
12 June 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1306008
27 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 537653
31 March 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305917
3 February 1986
COI Inspection · Credit Drydock
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292769
25 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982390
4 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1285873
1 November 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1284206
22 October 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 979001
Construction/Loadline
Issued 13 November 1990
Resolved
D5-STBD SIDE REPAIR #21 STANCHION COUNTING FROM FWD TO AFT.
Condition: Unknown
Due 12 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 November 1990
Resolved
D6-GAS FREE #2 PORT CARGO TANK FOR INTERNAL EXAMINATION OR HAVE MAIN DECK IN WAY OF #2CARGO TANK GAUGED IN THE PRESENT OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Deck/Cargo
Issued 13 November 1990
Resolved
D1-REPLACE MISSING BOLTS ON #1STBD AND #6PORT CARGO TANK PV VALVES.
Condition: Unknown
Due 12 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 13 November 1990
Resolved
D2-MAKE REPAIRS TO THE FOLLOWING CARGO DOME HATCH COVERS, #1PORT, #2STBD AND #3STBD.
Condition: Unknown
Due 12 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 November 1990
Resolved
D3-REPLACE MISSING GASKET FOR WATER TIGHT DOOR TO AFT DECK HOUSE.
Condition: Unknown
Due 12 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 November 1990
Resolved
D4-PORT SIDE REPAIR #3,11,AND 18 STANCHION COUNTING FROM FWD TO AFT.
Condition: Unknown
Due 12 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 3 October 1989
Resolved
FASTEN THE SHAFT GUARDS FOR THE BILGE PUMP AND PTO GENERATOR.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Deck/Cargo
Issued 3 October 1989
Resolved
PROVIDE LAGGING ON THE DRY EXHAUST FOR THE PORT CARGO PUMP ENGINE WHERE MISSING.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Electrical
Issued 12 June 1986
Resolved
PROVIDE (1) EXPLOSION-PROOF BLANK AND CAP WIRES ON LIGHTING FIXTURE IN STARBOARD ENGINE ROOM PRIOR TO DEPARTURE FROM SWANN OIL TERMINAL, CHESAPEAKE, VA.
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Construction/Loadline
Issued 3 February 1986
Resolved
RENEW MAIN DECK OVER CARGO TANKS 1 AND 2 P/S.
Condition: Unknown
Due 3 February 1986
Resolved 3 February 1986
Fire Fighting
Issued 3 February 1986
Resolved
PROVIDE TWO ADDITIONAL BII FIRE EXTINGUISHERS IN THE CARGO DECK AREA.
Condition: Unknown
Due 3 February 1986
Resolved 3 February 1986
Construction/Loadline
Issued 22 October 1984
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION BY THE ATTENDING CG MARINE INSPECTOR ALL CARGO TANKS PRIOR TO THE CARRIAGE OF CARGO.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984