Records from 1995 to 1996. Most recent: operational control imposed, 29 May 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 29 May 1996
Resolved
RENEW AS ORIGINAL AFTER VOID FRAMING AND SHELL PLATE. CORRECT AT NEXT DRYDOCK._x001C_
Condition: Unknown
Due 30 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE ONBOARD CURRENT EDITIONS OF U.S COAST PILOT #5, U.S. LIGHT LIST, TIDE & CURRENT TABLES AS REQUIRED. CORRECT PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 15 July 1996
Resolved 26 June 1996
Lifesaving
Issued 29 May 1996
Resolved
VESSEL IS REQUIRED TO HAVE 08 LIFE BOUYS. VESSEL HAD ONLY 03 ONBOARD REPLACE PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 15 July 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
VESSEL HAS WOODEN PLUG IN FLANGE SECTION VALVE ON STBD BALLAST TANK #4. INSTALL PROPER BLANK FLANGE. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
VESSEL'S MSD INOPERATIVE. CORRECT AS REQUIRED BY 33 C.F.R. 159 PRIOR TO NEXT US PORT.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 May 1996
Resolved
VESSEL'S #2 BALLAST TANK FILL VALVE NEEDS NEW GASKET.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Fire Fighting
Issued 29 May 1996
Resolved
VESSEL IS TO PROVIDE PROOF OF SERVICING FOR ALL PORTABLE FIRE EXTINGUISHERSPRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Electrical
Issued 29 May 1996
Resolved
VESSEL HAD NUMEROUS EXPOSED ELECTRICAL WIRING THROUGHOUT ENGINE ROOM. RESTOW PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Lifesaving
Issued 29 May 1996
Resolved
RENEW STBD RAMP BLOCK PADEYE. COMPLETE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 29 June 1996
Resolved 27 June 1996
Lifesaving
Issued 29 May 1996
Resolved
VESSEL'S EPIRB NOT IN A FLOAT FREE ARRANGEMENT AS REQUIRED. REPLACE/RESTOWPRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 15 July 1996
Resolved 27 June 1996
Fire Fighting
Issued 29 May 1996
Resolved
VESSEL WAS MISSING NOZZLE & SPANNER WRENCH FROM PORT SIDE FIRE STATION IN ENGINE ROOM. REPLACE PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
MAKE PERMANANT REPAIRS TO MAIN DECK PLATING WHERE FRACTURED OR WASTED. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Engineering
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE FUEL AND LUBE OIL CONTAIMENT AS REQUIRED BY 33 C.F.R. 155.320(b)(1), MUST CORRECT PRIOR TO NEXT US BUNKERING.
Condition: Unknown
Due 5 June 1996
Resolved 27 June 1996
Electrical
Issued 29 May 1996
Resolved
VESSEL HAD BARE LIGHT BULBS HUNG ACROSS ENGINE ROOM. REMOVE PRIOR TO DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
DOG MISSING ON AFT ENGINE ROOM WATER TIGHT DOOR. REPAIR/REPLACE PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
PERMANENTLY MARK LOADLINE ON VESSSEL'S SIDE SHELL AS PER LOADLINE CERTIFICATE. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 5 June 1996
Resolved 27 June 1996
Navigation
Issued 29 May 1996
Resolved
CHARTS # 25670 & 26540 WERE NOT CORRECTED TO DATE AS REQUIRED.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 May 1996
Resolved
COVER MISSING ON STEERING GEAR ELECTRICAL BOX. REPAIR PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Navigation
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE AN ENGLISH SPEAKING PERSON ONBOARD AS REQUIRED. CORRECT PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Navigation
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE CURRENT MAGNETIC DEVEIATION TABLE ONBOARD. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 May 1996
Resolved
VESSEL'S LIFERAFT WAS NOT ARRANGED IN A FLOAT FREE ARRANGEMENT AS REQUIRED.CORRECT PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Lifesaving
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE THE 12 REQUIRED TYPE OF FLARES ONBOARD. CORRECT PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 15 June 1996
Resolved 5 June 1996
Documentation
Issued 29 May 1996
Resolved
UNDER U.S. LAW VESSEL'S UNDER 300 GT. ARE REQUIRED TO HAVE 01 MASTER & 02 LIC. MATES AS REQUIRED BY 46 U.S.C. 8301. HAVE LICENCED CREW PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
REPAIR #3 FRAME AFT OF #4 BALLAST TANK SUCTION VALVE, PORT SIDE WHERE WASTED. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
AFT BULKHEAD OF ENGINE ROOM NOT WATER TIGHT AT PIPE PENETRATIONS. REPAIR PRIOR TO NEXT US PORT.
Condition: Unknown
Due 29 May 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
#3 FRAME AFT OF #4 BALLAST SUCTION VLAVE WAS CORRODED THROUGH AT WEB. REPAIR/REPLACE PRIOR TO SHIPS DEPARTURE.
Condition: Unknown
Due 29 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
MAKE PERMANANT REPAIRS TO AFT PORT CORNER OF ENGINE ROOM IN WAY OF SIDE PLATE, APPROXIMATELY 3' ABOVE DECK PLATES. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Engineering
Issued 29 May 1996
Resolved
VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES, MUST PROVIDE PRIOR TO NEXT US BUNKERING.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 May 1996
Resolved
PROVIDE PROTECTIVE COVERS FOR ALL LIGHTS THROUGHOUT THE VESSEL PRIOR TO NEXT US PORT.
Condition: Unknown
Due 5 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
WELD OVERHEAD PLATING AND FRAMES IN WAY OF INSERTS WHERE MAIN ENGINES WERE INSTALLED. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Fire Fighting
Issued 29 May 1996
Resolved
INSTALL FIRE DAMPERS FOR ENGINE ROOM VENT SYSTEM. CORRECT PRIOR TO NEXT USPORT.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 May 1996
Resolved
MAKE MAIN FIRE PUMP OPERATIONAL WHERE ELECRICAL MOTOR IS MISSING. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
PLUG HOLES IN THE ENGINE ROOM WATER TIGHT ENVELOPE WHERE PIPES AND WIRES HAVE BEEN REMOVED. ABOVE BOTH WATER TIGHT DOORS AT CENTERLINE AND BELOW THE FORWARD CENTERLINE DOOR. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
CLEAN FUEL FROM THE BILGE IN THE STARBOARD ENGINE ROOM ENTRANCEWAY. CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
REMOVE OR CAP ALL UNUSED PIPING SYSTEMS FROM ENGINE ROOM BILGE. (AT LEAST THREE DIFERENT SYSTEMS, 1 BILGE AT FWD BLKHD AND 2 UNKNOWN SYSTEMS NEAR CENTERLINE 1/3 OF THE WAY AFT OF FWD BLKHD) CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Fire Fighting
Issued 29 May 1996
Resolved
RENEW/REPAIR FIRE PLUG VALVE THAT WON'T CLOSE COMPLETELY AT MAIN DECK FORWARD BY AFT DOOR TO HOUSE. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 3 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
MAKE ENGINE ROOM BILGE ALARM OPERABLE. CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 5 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 30 January 1996
Resolved
Provide 1 Solas approved PFD for each Person on board._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 30 January 1996
Resolved
Make all hatches and doors water tight or weather tight as required.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 30 January 1996
Resolved
Make repairs to aft corner of P/S of E/R._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 30 January 1996
Resolved
Make repairs to leaks from main deck plating into E/R._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Make repairs to exhaust leaks to MDE's_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Provide cover for MDG._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Install guards on all machinery in E/R.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Repair leaks to lube oil pipping in E/R.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Provide proper covers for all electrical panels throught the vessel.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Repair fuel leaks on MDE's_x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 30 January 1996
Resolved
Have liferaft properly serviced and make float free._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 30 January 1996
Resolved
Remove and properly stow all flammable liguids and gas tanks throughout thevessel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 30 January 1996
Resolved
Remove propane tank from galley, reinstall outside with metalic pipping notrubber hose.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Provide protective covers for all lights throughout the vessel.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Remove all dead end wires throughout the vsl.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 30 January 1996
Resolved
Properly secure deck planking in passageway from E/R.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Repair lube oil sight glass in Port E/R.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Navigation
Issued 30 January 1996
Resolved
Provide harbor charts for San Juan, St Thomas and St. Croix.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Navigation
Issued 30 January 1996
Resolved
Provide current copies of Nav Rules, current tables, coast pilot and light list._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 30 January 1996
Resolved
Provide SOLAS Approved Flares 6 Smoke 6 Flare or 12 COMBO_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Provide electrical mat and wooden handle on main electrical switchboard._x001C_
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Electrical
Issued 30 January 1996
Resolved
Remove damaged leaking batteries from E/R.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 30 January 1996
Resolved
Make repairs to fuel/oil leaks on air compressor.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996