MAURY USCG vessel records
← All vessels

WALTER KEANE

Built
1951
Last inspected
27 July 1994
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 27 July 1994
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (1987–1994)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2285 - Regulatory (Subpart C or D), Gross Ton 1554 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-42647
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 54

27 July 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863272
20 July 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174349
22 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852979
21 February 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852974
25 February 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838870
12 February 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134051
19 January 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132939
17 December 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829581
12 November 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962231
26 October 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955858
23 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256829
11 August 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258412
13 February 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955784
18 December 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960871
15 November 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958348
24 October 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253080
22 August 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934701
31 May 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245130
31 May 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251202
30 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935491
1 May 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942583
26 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211778
14 March 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905477
19 February 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247903
5 February 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908444
13 November 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932092
5 November 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242630
2 November 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910749
16 August 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916148
30 July 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926834
16 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216638
7 May 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1229646
26 February 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241186
7 February 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913209
9 November 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222091
4 October 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314224
15 August 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338905
16 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346184
15 May 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 970247
8 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193809
1 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886562
21 March 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351876
15 February 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1209744
9 February 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040628
10 November 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895728
25 August 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196299
15 August 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036478
20 June 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345939
2 June 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037961
25 February 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037597
3 February 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008427
31 December 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1002749
15 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313005
22 July 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021827

Deficiency record · 73

Construction/Loadline
Issued 20 July 1994 Resolved
REMOVE WOOD FROM RAILS ON NYE SIE OF VESSEL AND MAKE REPAIRS TO RAIL AS NECESSARY (C/R WASTED STEEL).
Condition: Unknown
Due 20 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 July 1994 Resolved
MAKE REPAIRS (C/R) TO BULWARK AND VERTICAL STANCHIONS AS NECESSARY - BOTH TO GOOD METAL TO PROVIDE.
Condition: Unknown
Due 20 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 July 1994 Resolved
PROVIDE PLAN TO NEW YORK MIO TO REPAIR INOLEUM FLOOR ON INTERNAL MAIN DECK.
Condition: Unknown
Due 20 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 12 November 1992 Resolved
TRACE SMOKE DETECTION ZONES 8, 9, 18, & 19 WHERE MALFUNCTIONS EXIST, AND REPAIR SAME.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Fire Fighting
Issued 12 November 1992 Resolved
PROVIDE DIAGRAM FOR SMOKE DETECTION AND SPRINKLER SYSTEM IDENTIFYING LOCATION OF EACH ZONE.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Fire Fighting
Issued 13 February 1992 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS/PRISONERS CONDUCT IN PRESENCE OF USCG MARINE INSPECTOR FIRE A EVACUATION DRILLS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Fire Fighting
Issued 13 February 1992 Resolved
PROVIDE FOR INSPECTION USCG APPROVED FIRE FIGHTING AND SAFETY PLAN. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Documentation
Issued 13 February 1992 Resolved
PROVIDE FOR INSPECTION USCG APPROVED VESSEL EMERGENCY EVACUATION PLAN TO BECOMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Documentation
Issued 13 February 1992 Resolved
PROVIDE CORRECTED VESSEL DOCUMENTATION CERTIFICATE SHOWING THE SELF PROPELLED BLOCK AS "NO". TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Electrical
Issued 22 August 1991 Resolved
COVER ALL EMERGENCY LIGHTS WITH PROPER GLOBES.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Electrical
Issued 22 August 1991 Resolved
PROPERLY MARK ELECTRICAL DISTRIBUTION PANELS L-14 AND L-241 NEAR PILOT HOUSE.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Accommodation/Occupational Safety
Issued 22 August 1991 Resolved
PROVE SATISFACTORY OPERATION OF HEADS TO ENSURE PROPER SANITATION.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Documentation
Issued 22 August 1991 Resolved
PROVIDE CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Lifesaving
Issued 22 August 1991 Resolved
PROVE PROPER OPERATION OF BOTH REQUIRED RING BUOY FLOAT LIGHTS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Fire Fighting
Issued 22 August 1991 Resolved
REPLACE FIRE HOSES WITH PROPER U/L APPROVED HOSES.
Condition: Unknown
Due 20 November 1991
Resolved 20 November 1991
Fire Fighting
Issued 22 August 1991 Resolved
PROVIDE PROPER PORTABLE/SEMI PORTABLE FIRE EXTINGUISHERS IN REQUIRED LOCATIONS ACCORDING TO COI. (CO2 BOTTLES MUST HAVE HYDRO DATES NO OLDER THAN 5 YRS, ALSO ALL EXTINGUISHERS MUST BE PROPERLY MOUNTED).
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Electrical
Issued 1 May 1991 Resolved
LABEL ALL CIRCUIT BREAKER IN EMERGENCY DIST. PANEL. (SOME MISSING)
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991 Resolved
DEAD END OR REMOVE ELECTRICAL CABLE NOT USED IN SEWAGE ELEC. PANEL. (2 EACH).
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Fire Fighting
Issued 1 May 1991 Resolved
PROVE ALL FIRE EXTINGUISHERS (PORTABLES) ARE CURRENTLY SERVICED BY APPROVEDFACILITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991 Resolved
REPLACE LIFELINE IN LIFEBOATS.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 14 March 1991 Resolved
REPLACE MISSING PLATES AND MAKE ELECTRICALLY SAFE HOLES IN POWER PANELS L7_x001C_AND L8.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 5 February 1991 Resolved
PROVE OPERATION OF 120 VAC AND 230 VAC GROUND DETECTION SYSTEMS.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
REPLACE MISSING PLATES AND MAKE ELECTRICALLY SAFE HOLES IN POWER PANELS L7 AND L8.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
INSTALL MISSING PLATE IN ELECTRICAL POWER PANEL FOR IC PANEL FOR GENERATOR IC CIRCUIT.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
INSTALL MISSING GLOBES AND GUARDS ON ALL ENGINE ROOM LIGHTS.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
REMOVE TEMPORARY WIRING USED FOR CHECKING EMERGENCY BATTERY VOLTAGE IN ENGINEROOM.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
REMOVE ELECTRICAL WIRING PREVIOUSLY USED TO POWER STEP DOWN TRANSFORMERS WHICH ARE NOW REMOVED OR PROVE OTHER END OF CABLE IS ELECTRICALLY DISCONNECTED AND SAFE.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
REPLCE ALL BURNED AND CRACKED ENGINE ROOM LIGHT SOCKETS.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
CLOSE HOLE WHERE VOLTAGE SELECTOR SWITCH PREVIOUSLY EXISTED.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 20 FEB 91.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991 Resolved
REMOVE DEAD END WIRE BESIDE EMERGENCY GENERATOR.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Fire Fighting
Issued 5 February 1991 Resolved
PROVE PROPER OPERATION ON BOTH FIRE PUMP RELIEF VALVES.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Fire Fighting
Issued 5 February 1991 Resolved
REPLACE GAGE ON ENGINE ROOM FIRE PUMP, AND PROVE OPERATION.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Fire Fighting
Issued 5 November 1990 Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM ON ZONE 14 & 15.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 30 July 1990 Resolved
ATTACH BASKET TO LIFE FLOAT.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Fire Fighting
Issued 30 July 1990 Resolved
PROVIDE MARINE BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Electrical
Issued 30 July 1990 Resolved
LOCATE AND CORRECT GROUND FAULT ON 120V CIRCUIT.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Lifesaving
Issued 30 July 1990 Resolved
PROVE PROPER OPERATION ON GENERAL ALARM BELLS ON BRIDGE DECK AND SALOON DECK.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Fire Fighting
Issued 30 July 1990 Resolved
PROVIDE A SCBA CYLINDER WITH A HYDROSTATIC TEST DATE OF LESS THAN 3 YRS FORCOMPOSITE AND 5 YRS FOR STEEL CONSTRUCTION.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Fire Fighting
Issued 30 July 1990 Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM IN ZONES 2, 3, 6, 8, 13, 15, 15 & 19.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Electrical
Issued 7 May 1990 Resolved
DEMONSTRATE EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Electrical
Issued 7 May 1990 Resolved
PROVE PROPER OPERATION OF CATAPILLAR 250 EMERGENCY GENERATOR LOCATED SHORE SIDE INCLUDING AUTOMATIC TRANSFER.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Electrical
Issued 7 May 1990 Resolved
LOCATE AND REPAIR GROUND FAULT ON 115V AND 230V ELECTRICAL CIRCUITS.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Electrical
Issued 7 May 1990 Resolved
PROVE PROPER OPERATION OF LISTER EMERGENCY GENERATOR INCLUDING GENERATOR INCLUDING AUTOMATIC TRANSFER.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Accommodation/Occupational Safety
Issued 7 February 1990 Resolved
MAKE RECEIVER AVAILABLE FOR INTERNAL INSPECTION NEXT REINSPECTION.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Fire Fighting
Issued 7 February 1990 Resolved
REPAIR OR REPLACE LEAKING VALVE AT FIRE STATION NUMBER 3.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Fire Fighting
Issued 7 February 1990 Resolved
MAKE PROPER REPAIRS TO LEAKING FIRE MAIN ISOLATION VALVE IN FAN ROOM, BRIDGE DECK, STATEN ISLAND END.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Lifesaving
Issued 15 May 1989 Resolved
MAKE OPERATIONAL WATERLIGHTS ON 2 RINGBOUYS.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Lifesaving
Issued 15 May 1989 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM STATION AT CONTROL DESK.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Lifesaving
Issued 15 May 1989 Resolved
REPLACE OR REPAIR LIFEFLOAT NETTING TO BOARD IS PARTED.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Fire Fighting
Issued 8 May 1989 Resolved
CONNECT ENGINE ROOM FIRE PUMP TO HIGH SUCTION SEACHEST.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Fire Fighting
Issued 8 May 1989 Resolved
CONNECT BOILER ROOM FIRE PUMP TO HIGH SUCTION SEACHEST.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Fire Fighting
Issued 1 May 1989 Resolved
PROVE THE PROPER OPERATION OF THE FIRE/SMOKE DETECTION SYSTEM FOR ZONE 1, 4 AND 5.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Fire Fighting
Issued 9 February 1989 Resolved
CONDUCT PROPER FIRE DRILL.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Lifesaving
Issued 9 February 1989 Resolved
RE-WRITE WATCH QUARTER AND STATION BILL TO ELIMINATE USE OF PRISONERS IN EMERGENCY SITUATIONS AND TO INCORPORATE CORRECTION OFFICERS.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Lifesaving
Issued 9 February 1989 Resolved
PROVIDE A MEANS OF TWO-WAY COMMUNICATION FOR THE MATES, ENGINEERS AND DECKHANDS.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Fire Fighting
Issued 9 February 1989 Resolved
RELOCATE THE FIREMAIN SECTION TO A HIGHER POINT ON THE VESSEL'S HULL.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Documentation
Issued 9 February 1989 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Electrical
Issued 9 February 1989 Resolved
PROVE PROVER OPERATION OF GENERAL ALARM SWITCH NEAR GANGWAY BEHIND FRONT DESK.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Electrical
Issued 9 February 1989 Resolved
PROVE PROPER OPERATION OF FORWARD FAN ROOM VENT SHUTDOWN.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Fire Fighting
Issued 9 February 1989 Resolved
CONDUCT HYDRO TEST OF ALL FIRE HOSES ONBOARD.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Accommodation/Occupational Safety
Issued 9 February 1989 Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ENTRANCE OR EXIT FROM BOTH OF THE TWO MAIN STAIRTOWERS.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Accommodation/Occupational Safety
Issued 9 February 1989 Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ENTRANCE OR EXIT FROM BOTH OF THE VESSELS TO SHORE RAMPS.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Lifesaving
Issued 9 February 1989 Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ACCESS TO FIREFIGHTING AND LIFESAVING EQUIPMENT.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Fire Fighting
Issued 10 November 1988 Resolved
PROVE THE PROPER OPERATION OF THE FIRE/SMOKE DETECTION SYSTEM FOR ZONES 1,4AND 5.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Fire Fighting
Issued 10 November 1988 Resolved
PERMANENTLY MARK THE VENTILATION REMOTE SHUTDOWN SWICHES ON THE BRIDGE TO INDICATE WHICH AREAS ARE SECURED BY THE SWITCHES AND THE PURPOSE OF THE SWITCHES.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Fire Fighting
Issued 10 November 1988 Resolved
MAKE OPERATIONAL THE 19 POWER INDICATOR LIGHTS ON THE WATER SPRINKLER CONTROL PANEL.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Fire Fighting
Issued 10 November 1988 Resolved
MAKE OPERATIONAL ALL THE FIRE HYDRANT VALVES.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Fire Fighting
Issued 10 November 1988 Resolved
REPLACE MISSING FIRE NOZZLE SPUDS AT FIRE STATIONS 8,10, AND 18.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Accommodation/Occupational Safety
Issued 2 June 1988 Resolved
PROVE PROPER OPERATION OF BELOW VENTILATION SHUTDOWNS (MAIN DECK)
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Fire Fighting
Issued 2 June 1988 Resolved
CONDUCT A FIRE DRILL.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Fire Fighting
Issued 25 February 1988 Resolved
PROPERLY DEMONSTRATE FIRE AND EVACUATION DRILL WITH PASSENGERS (RESIDENTS) ON BOARD.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Fire Fighting
Issued 3 February 1988 Resolved
PROPERLY DEMONSTRATE FIRE AND EVACUATION DRILL WITH PASSENGERS (RESIDENTS) ON BOARD.
Condition: Unknown
Due 3 February 1988
Resolved 3 February 1988

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.