← All vessels
WALTER KEANE
WALTER KEANE is a 1951 passenger barge (inspected). The Coast Guard has recorded 54 inspections since 1987, most recently in July 1994, along with 73 deficiencies.
Records from 1987 to 1994. Most recent: inspection, 27 July 1994.
- Built
- 1951
- Last inspected
- 27 July 1994
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 73 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
261463
42647
Flag
UNITED STATES
367319830
Maury page id
psix-42647
Inspections, by type
…with no type recorded4
Years with a record
8 calendar years (1987–1994)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it1554 - Regulatory (Subpart C or D), Net Ton
2285 - Regulatory (Subpart C or D), Gross Ton
2285 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WD8425MMSI 367319830 · active · compulsorily equipped · granted 12 September 2017, expires 25 November 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 54
27 July 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863272
20 July 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174349
22 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852979
21 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852974
25 February 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838870
12 February 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134051
19 January 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132939
17 December 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829581
12 November 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962231
26 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955858
23 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256829
11 August 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258412
13 February 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955784
18 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960871
15 November 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958348
24 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253080
22 August 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934701
31 May 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245130
31 May 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251202
30 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935491
1 May 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942583
26 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211778
14 March 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905477
19 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247903
5 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908444
13 November 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932092
5 November 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242630
2 November 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910749
16 August 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916148
30 July 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926834
16 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216638
7 May 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1229646
26 February 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241186
7 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913209
9 November 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222091
4 October 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314224
15 August 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338905
16 June 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346184
15 May 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 970247
8 May 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193809
1 May 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886562
21 March 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351876
15 February 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1209744
9 February 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040628
10 November 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895728
25 August 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196299
15 August 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036478
20 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345939
2 June 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037961
25 February 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037597
3 February 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008427
31 December 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1002749
15 September 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313005
22 July 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021827
Deficiency record · 73
Construction/Loadline
Issued 20 July 1994
Resolved
REMOVE WOOD FROM RAILS ON NYE SIE OF VESSEL AND MAKE REPAIRS TO RAIL AS NECESSARY (C/R WASTED STEEL).
Construction/Loadline
Issued 20 July 1994
Resolved
MAKE REPAIRS (C/R) TO BULWARK AND VERTICAL STANCHIONS AS NECESSARY - BOTH TO GOOD METAL TO PROVIDE.
Construction/Loadline
Issued 20 July 1994
Resolved
PROVIDE PLAN TO NEW YORK MIO TO REPAIR INOLEUM FLOOR ON INTERNAL MAIN DECK.
Fire Fighting
Issued 12 November 1992
Resolved
TRACE SMOKE DETECTION ZONES 8, 9, 18, & 19 WHERE MALFUNCTIONS EXIST, AND REPAIR SAME.
Fire Fighting
Issued 12 November 1992
Resolved
PROVIDE DIAGRAM FOR SMOKE DETECTION AND SPRINKLER SYSTEM IDENTIFYING LOCATION OF EACH ZONE.
Fire Fighting
Issued 13 February 1992
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS/PRISONERS CONDUCT IN PRESENCE OF USCG MARINE INSPECTOR FIRE A EVACUATION DRILLS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 13 February 1992
Resolved
PROVIDE FOR INSPECTION USCG APPROVED FIRE FIGHTING AND SAFETY PLAN. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Documentation
Issued 13 February 1992
Resolved
PROVIDE FOR INSPECTION USCG APPROVED VESSEL EMERGENCY EVACUATION PLAN TO BECOMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Documentation
Issued 13 February 1992
Resolved
PROVIDE CORRECTED VESSEL DOCUMENTATION CERTIFICATE SHOWING THE SELF PROPELLED BLOCK AS "NO". TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Electrical
Issued 22 August 1991
Resolved
COVER ALL EMERGENCY LIGHTS WITH PROPER GLOBES.
Electrical
Issued 22 August 1991
Resolved
PROPERLY MARK ELECTRICAL DISTRIBUTION PANELS L-14 AND L-241 NEAR PILOT HOUSE.
Accommodation/Occupational Safety
Issued 22 August 1991
Resolved
PROVE SATISFACTORY OPERATION OF HEADS TO ENSURE PROPER SANITATION.
Documentation
Issued 22 August 1991
Resolved
PROVIDE CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Lifesaving
Issued 22 August 1991
Resolved
PROVE PROPER OPERATION OF BOTH REQUIRED RING BUOY FLOAT LIGHTS.
Fire Fighting
Issued 22 August 1991
Resolved
REPLACE FIRE HOSES WITH PROPER U/L APPROVED HOSES.
Fire Fighting
Issued 22 August 1991
Resolved
PROVIDE PROPER PORTABLE/SEMI PORTABLE FIRE EXTINGUISHERS IN REQUIRED LOCATIONS ACCORDING TO COI. (CO2 BOTTLES MUST HAVE HYDRO DATES NO OLDER THAN 5 YRS, ALSO ALL EXTINGUISHERS MUST BE PROPERLY MOUNTED).
Electrical
Issued 1 May 1991
Resolved
LABEL ALL CIRCUIT BREAKER IN EMERGENCY DIST. PANEL. (SOME MISSING)
Electrical
Issued 1 May 1991
Resolved
DEAD END OR REMOVE ELECTRICAL CABLE NOT USED IN SEWAGE ELEC. PANEL. (2 EACH).
Fire Fighting
Issued 1 May 1991
Resolved
PROVE ALL FIRE EXTINGUISHERS (PORTABLES) ARE CURRENTLY SERVICED BY APPROVEDFACILITY._x001C_ _x001C_ _x001C_
Lifesaving
Issued 1 May 1991
Resolved
REPLACE LIFELINE IN LIFEBOATS.
Electrical
Issued 14 March 1991
Resolved
REPLACE MISSING PLATES AND MAKE ELECTRICALLY SAFE HOLES IN POWER PANELS L7_x001C_AND L8.
Electrical
Issued 5 February 1991
Resolved
PROVE OPERATION OF 120 VAC AND 230 VAC GROUND DETECTION SYSTEMS.
Electrical
Issued 5 February 1991
Resolved
REPLACE MISSING PLATES AND MAKE ELECTRICALLY SAFE HOLES IN POWER PANELS L7 AND L8.
Electrical
Issued 5 February 1991
Resolved
INSTALL MISSING PLATE IN ELECTRICAL POWER PANEL FOR IC PANEL FOR GENERATOR IC CIRCUIT.
Electrical
Issued 5 February 1991
Resolved
INSTALL MISSING GLOBES AND GUARDS ON ALL ENGINE ROOM LIGHTS.
Electrical
Issued 5 February 1991
Resolved
REMOVE TEMPORARY WIRING USED FOR CHECKING EMERGENCY BATTERY VOLTAGE IN ENGINEROOM.
Electrical
Issued 5 February 1991
Resolved
REMOVE ELECTRICAL WIRING PREVIOUSLY USED TO POWER STEP DOWN TRANSFORMERS WHICH ARE NOW REMOVED OR PROVE OTHER END OF CABLE IS ELECTRICALLY DISCONNECTED AND SAFE.
Electrical
Issued 5 February 1991
Resolved
REPLCE ALL BURNED AND CRACKED ENGINE ROOM LIGHT SOCKETS.
Electrical
Issued 5 February 1991
Resolved
CLOSE HOLE WHERE VOLTAGE SELECTOR SWITCH PREVIOUSLY EXISTED.
Electrical
Issued 5 February 1991
Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 20 FEB 91.
Electrical
Issued 5 February 1991
Resolved
REMOVE DEAD END WIRE BESIDE EMERGENCY GENERATOR.
Fire Fighting
Issued 5 February 1991
Resolved
PROVE PROPER OPERATION ON BOTH FIRE PUMP RELIEF VALVES.
Fire Fighting
Issued 5 February 1991
Resolved
REPLACE GAGE ON ENGINE ROOM FIRE PUMP, AND PROVE OPERATION.
Fire Fighting
Issued 5 November 1990
Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM ON ZONE 14 & 15.
Lifesaving
Issued 30 July 1990
Resolved
ATTACH BASKET TO LIFE FLOAT.
Fire Fighting
Issued 30 July 1990
Resolved
PROVIDE MARINE BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Electrical
Issued 30 July 1990
Resolved
LOCATE AND CORRECT GROUND FAULT ON 120V CIRCUIT.
Lifesaving
Issued 30 July 1990
Resolved
PROVE PROPER OPERATION ON GENERAL ALARM BELLS ON BRIDGE DECK AND SALOON DECK.
Fire Fighting
Issued 30 July 1990
Resolved
PROVIDE A SCBA CYLINDER WITH A HYDROSTATIC TEST DATE OF LESS THAN 3 YRS FORCOMPOSITE AND 5 YRS FOR STEEL CONSTRUCTION.
Fire Fighting
Issued 30 July 1990
Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM IN ZONES 2, 3, 6, 8, 13, 15, 15 & 19.
Electrical
Issued 7 May 1990
Resolved
DEMONSTRATE EMERGENCY LIGHTING SYSTEM.
Electrical
Issued 7 May 1990
Resolved
PROVE PROPER OPERATION OF CATAPILLAR 250 EMERGENCY GENERATOR LOCATED SHORE SIDE INCLUDING AUTOMATIC TRANSFER.
Electrical
Issued 7 May 1990
Resolved
LOCATE AND REPAIR GROUND FAULT ON 115V AND 230V ELECTRICAL CIRCUITS.
Electrical
Issued 7 May 1990
Resolved
PROVE PROPER OPERATION OF LISTER EMERGENCY GENERATOR INCLUDING GENERATOR INCLUDING AUTOMATIC TRANSFER.
Accommodation/Occupational Safety
Issued 7 February 1990
Resolved
MAKE RECEIVER AVAILABLE FOR INTERNAL INSPECTION NEXT REINSPECTION.
Fire Fighting
Issued 7 February 1990
Resolved
REPAIR OR REPLACE LEAKING VALVE AT FIRE STATION NUMBER 3.
Fire Fighting
Issued 7 February 1990
Resolved
MAKE PROPER REPAIRS TO LEAKING FIRE MAIN ISOLATION VALVE IN FAN ROOM, BRIDGE DECK, STATEN ISLAND END.
Lifesaving
Issued 15 May 1989
Resolved
MAKE OPERATIONAL WATERLIGHTS ON 2 RINGBOUYS.
Lifesaving
Issued 15 May 1989
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM STATION AT CONTROL DESK.
Lifesaving
Issued 15 May 1989
Resolved
REPLACE OR REPAIR LIFEFLOAT NETTING TO BOARD IS PARTED.
Fire Fighting
Issued 8 May 1989
Resolved
CONNECT ENGINE ROOM FIRE PUMP TO HIGH SUCTION SEACHEST.
Fire Fighting
Issued 8 May 1989
Resolved
CONNECT BOILER ROOM FIRE PUMP TO HIGH SUCTION SEACHEST.
Fire Fighting
Issued 1 May 1989
Resolved
PROVE THE PROPER OPERATION OF THE FIRE/SMOKE DETECTION SYSTEM FOR ZONE 1, 4 AND 5.
Fire Fighting
Issued 9 February 1989
Resolved
CONDUCT PROPER FIRE DRILL.
Lifesaving
Issued 9 February 1989
Resolved
RE-WRITE WATCH QUARTER AND STATION BILL TO ELIMINATE USE OF PRISONERS IN EMERGENCY SITUATIONS AND TO INCORPORATE CORRECTION OFFICERS.
Lifesaving
Issued 9 February 1989
Resolved
PROVIDE A MEANS OF TWO-WAY COMMUNICATION FOR THE MATES, ENGINEERS AND DECKHANDS.
Fire Fighting
Issued 9 February 1989
Resolved
RELOCATE THE FIREMAIN SECTION TO A HIGHER POINT ON THE VESSEL'S HULL.
Documentation
Issued 9 February 1989
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Electrical
Issued 9 February 1989
Resolved
PROVE PROVER OPERATION OF GENERAL ALARM SWITCH NEAR GANGWAY BEHIND FRONT DESK.
Electrical
Issued 9 February 1989
Resolved
PROVE PROPER OPERATION OF FORWARD FAN ROOM VENT SHUTDOWN.
Fire Fighting
Issued 9 February 1989
Resolved
CONDUCT HYDRO TEST OF ALL FIRE HOSES ONBOARD.
Accommodation/Occupational Safety
Issued 9 February 1989
Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ENTRANCE OR EXIT FROM BOTH OF THE TWO MAIN STAIRTOWERS.
Accommodation/Occupational Safety
Issued 9 February 1989
Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ENTRANCE OR EXIT FROM BOTH OF THE VESSELS TO SHORE RAMPS.
Lifesaving
Issued 9 February 1989
Resolved
PERMANENTLY REMOVE LOCKS PREVENTING ACCESS TO FIREFIGHTING AND LIFESAVING EQUIPMENT.
Fire Fighting
Issued 10 November 1988
Resolved
PROVE THE PROPER OPERATION OF THE FIRE/SMOKE DETECTION SYSTEM FOR ZONES 1,4AND 5.
Fire Fighting
Issued 10 November 1988
Resolved
PERMANENTLY MARK THE VENTILATION REMOTE SHUTDOWN SWICHES ON THE BRIDGE TO INDICATE WHICH AREAS ARE SECURED BY THE SWITCHES AND THE PURPOSE OF THE SWITCHES.
Fire Fighting
Issued 10 November 1988
Resolved
MAKE OPERATIONAL THE 19 POWER INDICATOR LIGHTS ON THE WATER SPRINKLER CONTROL PANEL.
Fire Fighting
Issued 10 November 1988
Resolved
MAKE OPERATIONAL ALL THE FIRE HYDRANT VALVES.
Fire Fighting
Issued 10 November 1988
Resolved
REPLACE MISSING FIRE NOZZLE SPUDS AT FIRE STATIONS 8,10, AND 18.
Accommodation/Occupational Safety
Issued 2 June 1988
Resolved
PROVE PROPER OPERATION OF BELOW VENTILATION SHUTDOWNS (MAIN DECK)
Fire Fighting
Issued 2 June 1988
Resolved
CONDUCT A FIRE DRILL.
Fire Fighting
Issued 25 February 1988
Resolved
PROPERLY DEMONSTRATE FIRE AND EVACUATION DRILL WITH PASSENGERS (RESIDENTS) ON BOARD.
Fire Fighting
Issued 3 February 1988
Resolved
PROPERLY DEMONSTRATE FIRE AND EVACUATION DRILL WITH PASSENGERS (RESIDENTS) ON BOARD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.